Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹713.1 CrAdmitted-Finance A 760 SUSHANT LOK PHASE 1 GURGAON 122002 HARYANA INDIA | ₹713.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹721.9 CrAdmitted-Finance C 4 DISTRICT CENTRE SAKET NEW DELHI 110017 | SOUTH | DELHI | 110017 | ₹721.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹754.1 CrAdmitted-Finance 401 THE GRAND MALL OPP STATE BANK ZONAL OFFICE S M ROAD AMBAWADI AHMEDABAD 380015 | AHMADABAD | GUJARAT | 380015 | ₹754.1 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not meeting qualifying criteria |
| Sl No | Description | Qty | Unit | Dineshchandra R Agrawal Infracon Pvt. Ltd. L3 | COMT CONSTRUCTIONS PRIVATE LIMITED L1 | Ircon International Limited L2 |
|---|---|---|---|---|---|---|
| 1.00Total Amount of BoQ 2 | ||||||
| 2.00 | Amount after unconditional Rebate | 1 | Sqm | 0 ₹251.4 Cr | 0 ₹237.7 Cr | 0 ₹240.6 Cr |
Tender Value
₹254.3 Cr
EMD Value
₹1 Cr
Closing Date
19 Mar 2025, 5:00 pmClosed
GGM/Airports)
GGM (Airports), 4th Floor, RITES Office Complex, Shikhar, Plot No. - 1, Sector - 29, Gurgaon - 122 001 (Haryana)
Construction of Integrated Check Post at Dodhara Chandani in Nepal
2025_RITES_222653_1
RITES/AP/ICP/ DODHARA/Tender/2025/01
Open Tender
Civil Works
30 days
Dodhara Chandani, Nepal (Opposite Banbasa India)
As per tender document
7 documents required · 7 mandatory
₹15,000
RITES Limited
₹1 Cr
15 May 2025
4 Jan 2025
21 Mar 2025
4 Jan 2025
19 Mar 2025
29 Jan 2025
4 Jan 2025 - 22 Jan 2025
Amount
Total Amount of BoQ 2
Amount after unconditional Rebate
Description of Work / Item(s)
Amount
Total of (BoQ 3, BoQ 4, BoQ 5, BoQ 6,BoQ 7,BoQ 8 )
Total Amount of BoQ3 (Civil Schedule Items Percentage Rate)
Total Amount of BoQ4 ( Civil Market Item Rate)
Total Amount of BoQ5 (Electrical Schedule Items Percentage Rate)
Total Amount of BoQ6 (Electrical Market Item Rate)
Total Amount of BoQ7 (Signage & Furniture Market Item Rate)
Total Amount of BoQ8 (Prime Cost Market Item Rates)
Bidder Name
Amount
Dineshchandra R Agrawal Infracon Pvt. Ltd. (GSTN-24AABCD9523D1Z0) BID ID -831282
COMT CONSTRUCTIONS PRIVATE LIMITED (GSTN-07AAACC4019L2ZO) BID ID -831363
Ircon International Limited (GSTN-NA) BID ID -830778
Description of Work / Item(s)
Amount
Schedule-II
CIVIL WORKS NON SCHEDULE
BUILDINGS & SHED
Earthwork in excavation by mechanical means(hydraulic excavation)/manual means over areas including getting out and disposal of excavated earth for all lead and lift as directed by Engineer-in-charge. (all kind of soil/RBM )
Filling available excavated earth/RBM (excluding rock ) in trenches, plinthes, sides of foundations etc, in layers not exceeding 20 cm in depth, consolidating each depositing layer by ramming and watering for all lead and lift.
Excavating, supplying and filling of local earth (including royalty)/RBM(River bed material) by mechanical transport for all lead and lift also including ramming and watering of filling materials in layers not exceeding 20 cm depth in trenches, plinth,sides of foundation etc. (Maximum size of material 4.75mm)
Granite work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the granite shade (To be secured to the backing by means of cramps & rates are inclsuve in this items).
Granite work gang saw cut (flame finish) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the granite shade (To be secured to the backing by means of cramps & rates are inclsuve in this items).
Providing and laying burnt clay face brick tiles (as per approved pattern 17-20 mm nominal thickness of 230x75 mm size & of approved make ) over 12 mm thick rough plastered in 1:3 (1 cement : 3 coarse sand) walls jointed with cement mortar 1:3 (1 cement : 3 coarse sand) jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade and complete. (Rates are inclusive of water proofing material, plaster and preparation of surface etc.)
Providing and laying vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622 of approved brand and manufacturer, in all colours and shades in dado up to any height, skirting, riser of steps laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6mm thickness, including grouting of joints
Providing and laying pressed clay tile (Mangalore tile) (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Rates are inclusive of water proofing material, plaster nd preparation of surface etc.)
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, roviding suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and unctional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and rotection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance haracteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be included under this items . However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories ccreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable eparately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and Importance of the work.Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025
1.Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr.
2.Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing method for a range up to 2000 ml.
3.Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”
4.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing method for a range upto 50 mm”
5.Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site.
6.Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing and fixing precoated galvanised iron profile sheets including Ridges (500-600mm),Gutters ,Flashings/Aprons up to 600mm) (size, shape and pitch of corrugation as approved by Engineer-in Charge) - The sheets shall have total coated thickness (TCT) of 0.50 mm with Zinc Aluminium Alloy of AZ- 150 (as per AS 1397-1993) yield strength of 550MPA. The sheets shall have a hot dip metallic Zinc- Aluminium Alloy coating of Zn- 45% and Al- 55% with total mass coating of 150 gsm/sqm on both sides. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, including the cost of purlins, rafters and trusses and including cutting to size and shape, sealant,sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) Flashings/ Aprons.( Upto 600 mm) North light curves Barge board (Upto 300 mm) Crimp curve Gutter (600 mm over all girth)
VDF Floor with concrete hardener topping under layer 100 mm thick using machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinfoced cement concrete work incluidng pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability M25 grade reinforced cement concrete by using 330 kg of cement per cum of concrete laid in alternate panels, channel formwork, including levelling, consolidation , withdrawal of excess water and finishing with compactor / power trowel sprinkling of extra cement, cutting grooves of size 4 x 15mm deep (groove spacing shopuld not exceed 5m in either direction) using diamond point concrete saw, filling the grooves with approved joint filler polysulphide sealant etc., complete (Reinforcement measured and paid seperately)
Supplying, providing, and fixing in position horizontal/ vertical or curved surfaces at all heights, Sky Light sheet- 10 mm thick multi-walled Polycarbonate sheet including all required accessories like Aluminium strip with rubber seal, screw, sealant etc for supporting of sheets to give leak proof area with all T & P, scaffolding etc
Providing and laying 100% solution dyed PP multilevel loop carpet of size 50mm X 50mm /25mm x100m. The gauge of the carpet should be minimum 1/12 inch with minimum stiches per inch is 9.5-10. The pile height should vary between 2.5mm – 5.5 mm and the minimum pile weight should be 600 g/m2 with a backing of E-bac. The carpet should pass Flammability as per ASTM E648 and smoke density as per ASTM E662, completed as per specification and approval of Engineer-in-Charge.
Design ,Fabrication ,Supply , installation, Testing & Commissioning of Bi-Parting Automatic Sliding Door Operator complete two fixed side screens with all aaceesories/harwares including the civil works . The door is activated by radar units mounted either side of the threshold. Side screen safety is provided by presence sensors mounted above the door run back area. All operating and safety accessories shall be supplied by Electro Automation as part of this contract. The screen and doors shall be manufactured from proprietary Aluminium sections. The overall screen size shall be as per the drawings and existing color, Measurements must be verified on site and shall be the contractor’s responsibility. (a) Sliding glass door- Bi- parting 10 mm thick glass without frame Automation system push button.Total opening (w)5.44mt x (h)2.7mt height (b_ Door opening consider (w)2mt x (h)2.4mt height, Fix panel – vertical 2nos Size (w)1.72mt x (h)2.4mt (c) Top horizontal fix panel – (w)5.44mt x (h)300mm height – 1nos,Toughened 10mm thick glass Top automatic operator including radar both side
Design, fabrication, supply and installation including welding, assembling and fixing in position, erecting at site at all heights tubular space structure system to support roof and consisting of electric resistance or induction butt welded tubes/pipes confirming to IS: 1161/1239/3589/4923 ERW Steel pipe of approved equivalent and forged/machined mild steel cones/ props/ tube end connectors, solid forged spherical node connectors, High tensile bolts, support system, stubs and mild steel base plate, columns and other structural members conforming to IS: 2062 as per approved space structure system and including transportation, cutting, threading, machining, leads and lifts up to all heights, tools and plants and necessary scaffolding etc. required for all operations involved. The complete structure to be painted with one coat of epoxy primer and one coat of polyurethane paint as per Engineer-in charge.
Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 60x60x 75 cm of mix 1:2:4(1 cement:2 fine sand : 4 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 60x60x75 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (Rates are inclusive of all like- posts, welded steel wire fabric, painting, earth work in excavation and concrete etc. as per direction of Engineer-in-charge ).
Providing and fixing weep holes in Brick masonary/Plain/Reinforced in Abutments, wing walls and retaining walls etc with 110 mm dia UPVC pipes Type A ISI marked extending through the full width of the structure with slope with slope 1V:20H as per specifications and as directed Engineer-in Charge.
PEB WORKS
Design,manufacture,supply & erection of Pre-engineered Building as per building description (Animal Shed) - As per Drawing Ref:-RITES/AP/DC/Arch/Animal Shed/01 Building Type : Clear Span Width : 9.0 Mtrs. O/O Of Steel Line. Length : 16.920 Mtrs. O/O Of Steel Line. End Wall Col. Spacing : Not Applicable Roof Slope : 1:10 Clear Height : as per drawing Diagonal Bracing (type/location): Diagonal Rod Bracing Is considered in Roof Only.
Diagonal Bracing (FEW/BEW ) : Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls. Roofing : . Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : . Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Daylight panels (nos. and %) : NA Eave Gutter /Flashing /Downpipe : Matching to roof & wall
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Fully Open Condition (Permeability More Than 20%). 3. Eave Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from FFL (0.0m Level). 5. Downtakes are considered upto FFL Level. 6. 600mm Projection Is Considered All Around The Building. 7. MS Grills Are Not In PEB Scope Of Supply. 8. Full Length Jack Beam Is Considered At Both Sidewalls Of Building To Support TheIntermedaite Frame. 9. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity.
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are .’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). . will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers L) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer.
Design,manufacture,supply& erection of pre-Engineered Building as per description : Fumigation shed As per drawing Ref: RITES/AP/DC/ARCH/ FUMIGATION SHED/01 Building Type :Clear Span Width : 11.50 Mtrs. O/O Of Steel Line. Length : 16.0 Mtrs. O/O Of Steel Line. Line. Roof Slope : 1:10 Clear Height : 6.0M Clear Height Under The Knee/as per drawing Brick wall height : As per drawings Diagonal Bracing (type/location) : Diagonal Rod/Pipe Bracing Is considered in Roof Only.
Diagonal Bracing (FEW/BEW ) : Rigid End Frame Frame (Half Bay Loaded) Frame is considered at B EndWalls. Roofing : . Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : . Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel.Daylight panels (nos.and %): NA Eave Gutter /Flashing /Downpipe: Matching to roof & wall
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Partially Enclosed Condition (Permeability : 5 To 20%). 3. Eave Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from FFL (0.0m Level). 5. Downtakes are considered upto FFL Level. 6. 1000mm Projection Is Considered All Around The Building. 7. No Arrangement Is Considered For 1.0M Wide Pathway In PEB Scope Of Supply. 8. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity.
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are .’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). . will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave & Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers L) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer.
Design,manufacture,supply & erection of Pre-engineered Building as per building description Building Descriptions: : Porters Rest Area-A as per drawing Ref: RITES/AP/DC/ARCH/PORTER REST AREA/01 Building Type : . Clear Span Width : 20.0 Mtrs. O/O Of Steel Line. Steel Column Length : 20.0 Mtrs. O/O Of Steel Line. Steel Column Roof Slope : 1:10
Clear Height : 4.50M Clear Height Under The Knee/as per drawing Full height Brickwall @ 3m & wall cladding above it with polycarbonate sheet for the Kitchen, Store & Handwashed area as specified in Drawings reffered above. Diagonal Bracing (type/location) : Diagonal Rod Bracing Is considered in Roof & Sidewalls. Diagonal Bracing (FEW/BEW ) : Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls. Roofing : . Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel.
Wall : . Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Daylight panels (nos. and %) : NA Eave Gutter /Flashing /Downpipe : Matching to roof & wall
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability More Than 20% (Large Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from FFL (0.0m Level). 5. Downtakes are considered upto FFL Level. 6. 1000mm Projection Is Considered All Around The Building. 7. Water Will Be Drained Inside Building At Each Column Location From Valley Gutter. 8. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity.
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are .’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). . will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Wall Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer.
Design,manufacture,supply & erection of Pre-engineered Building as per building description & the drawings (RITES/AP/DC/ARCH/PORTER REST AREA/01) Porters Rest Area-B (1 No.) Building Type : Clear Span Width : 20.0 Mtrs. O/O Of Steel Line. Column Length : 20.0 Mtrs. O/O Of Steel Line. Column Roof Slope : 1:10 Clear Height : 4.50M Clear Height Under The Knee/as per drawing
Brick wall height : Full height Brickwall @ 3m & wall cladding above it with polycarbonate sheet for the Kitchen, Store & Handwashed area as specified in Drawings reffered above. Diagonal Bracing (type/location) : Diagonal Rod Bracing Is considered in Roof & Sidewalls. Diagonal Bracing (FEW/BEW ) : Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls. Roofing : Supertech Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : Supertech Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Daylight panels (nos.and %): NA Eave Gutter /Flashing/Downpipe: Matching to roof & wall
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability More Than 20% (Large Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from FFL (0.0m Level). 5. Downtakes are considered upto FFL Level. 6. 1000mm Projection Is Considered All Around The Building. 7. Water Will Be Drained Inside Building At Each Column Location From Valley Gutter. 8. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity.
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are Supertech’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). Supertech will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer.
Design,manufacture,supply & erection of Pre-engineered Building as per building descriptions & drawing Ref: RITES/AP/DC/ARCH/WCO/01&02 Building Descriptions: Warehouse Building Type : Clear Span Width : 20.0 Mtrs. O/O Of Steel Line. Width Module : 1 @ 20.0 Mtrs. O/O Of Steel Line. Length : 75.0 Mtrs. O/O Of Steel Line. No. Of Bay Spacing : As per drawing End Wall Col. Spacing : As per drawing. Roof Slope : 1:10 Clear Height : 7.75M Clear Height Under The Knee as per drawing Brick wall height : 3.0Mtrs. Brickwall & wall Cladding over the 3.0 m height brick work or office areas all around the building as specified in drawings. Diagonal Bracing (type/location) : Diagonal Rod Bracing Is considered in Roof & Both Sidewalls. Diagonal Bracing (FEW/BEW ) : Rigid End Frame Frame (Half Bay Loaded) Fra Roofing : . Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : . Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel.
Daylight panels (nos. and %) : Polycarbonate Sheet, 2.0mm Thick, 10 Nos. Of Size 2400mm x 600mm Eave Gutter /Flashing /Downpipe : Matching to roof & wall S Type Louvers : 1.0M High S-Type Louvers Is Considered At Both Sidewall Of Building Turbovents : 600mm Throat Dia., 2 Nos. In Each Bay (Total 10 Nos. In Roof) Canopy (height / width / location) Additional Load : • Additional Load Of 10 Kg/Sqm. On Roof For Services Etc. • Additional Load Of 150 Kg/Rmt On All Around The Periphery Of Sidewall Columns For Cable Tray & Pipe Rack. • Only Brackets & Loading Is Considered For Same In PEB Scope.
Mezzanine : Dead Load = 250 Kg/Sqm. for Deck sheeting area 169.40 sqm as per drawing & the RCC area for offices @ 400.0sqm as per drawing Live Load = 300 Kg/Sqm. Mezzanine Area = 20M X 7.50M Mezzanine Height = as per drawing 0.80mm Thick GI Deck Sheet Is Considered For Mezzanine Area. All steel ladder/ Staircase Is Considered For Mezzanine Access of Deck sheeting/RCC area.
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability Between 5-20% (Medium Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from 1.0M Above FFL. 5. Downtakes are considered upto FFL Level. 6. Framed Opening, Window Opening Which Are Coming In Brickwall Is Not In SIPL ScopeOf Supply, No Arrangement Is Considered For Same. 7. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity (The total rate includes mezzanine work)
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are .’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). . will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Mezzanine & Decking 0.8mm GI with steel ladder/staircase m) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer. ( Rates are inclusive of all operations including design of civil structures, retaining wall etc.)
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners.
Design,manufacture,supply & erection of Pre-engineered Building as per building description & drawing Ref: RITES/AP/DC/ARCH/LIS/01&02 Litigation Shed Building Type : Clear Span Width : 20.0 Mtrs. O/O Of Steel Line. Width Module : 1 @ 20.0 Mtrs. O/O Of Steel Line. Length : 75.0 Mtrs. O/O Of Steel Line. No. Of Bay Spacing : As per drawing End Wall Col. Spacing : As per drawing Roof Slope : 1:10 Clear Height : 7.75M Clear Height Under The Knees per drawing Brick wall height : 3.0Mtrs. Brickwall & wall Cladding over the 3.0 m height brick work or office areas all around the building as specified in drawings. Diagonal Bracing (type/location): Diagonal Rod Bracing Is considered in Roof & Both Sidewalls. Diagonal Bracing (FEW/BEW ): Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls.
Roofing : Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : Supertech Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Daylight panels (nos. and %) : Polycarbonate Sheet, 2.0mm Thick, 10 Nos. Of Size 2400mm x 600mm Eave Gutter /Flashing/Downpipe: Matching to roof & wall S Type Louvers : 1.0M High S-Type Louvers Is Considered At Both Sidewall Of Building Turbovents : 600mm Throat Dia., 2 Nos. In Each Bay (Total 10 Nos. In Roof) Canopy (height / width / location)
Additional Load : • Additional Load Of 10 Kg/Sqm. On Roof For Services Etc. • Additional Load Of 150 Kg/Rmt On All Around The Periphery Of Sidewall Columns For Cable Tray & Pipe Rack. • Only Brackets & Loading Is Considered For Same In PEB Scope. Mezzanine : Dead Load = 250 Kg/Sqm. For 100mm Thick RCC Slab Live Load = 300 Kg/Sqm. Mezzanine Area = 20M X 7.50M Mezzanine Height = 4.0M Top Of Mezzanine Floor 0.80mm Thick GI Deck Sheet Is Considered For Mezzanine Area. 1 Nos. Of Staircase Is Considered For Mezzanine Access.
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability Between 5-20% (Medium Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from 1.0M Above FFL. 5. Downtakes are considered upto FFL Level. 6. Framed Opening, Window Opening Which Are Coming In Brickwall Is Not In SIPL ScopeOf Supply, No Arrangement Is Considered For Same. 7. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity. (The total rate includes mezzanine work)
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are Supertech’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). Supertech will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Mezzanine & Decking 0.8mm GI including steel ladder/staircase m) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer.( Rates are inclusive of all operations including design of civil structures, retaining wall etc.)
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners
Design,manufacture,supply & erection of Pre-engineered Building as per building description drawing Ref: RITES/AP/DC/ARCH/ISCO/01&02 Inspection Shed Building Type : Clear Span Width : 20.0 Mtrs. O/O Of Steel Line. Length : 75.0 Mtrs. O/O Of Steel Line. No. Of Bay Spacing : As per drawing End Wall Col. Spacing : As per drawing Roof Slope : 1:10 Clear Height : 7.75M Clear Height Under The Knee as per drawing Brick wall height : 3.0Mtrs. Brickwall& Above Cladding All Around The Building. Diagonal Bracing (type/location): Diagonal Rod Bracing Is considered in Roof & Both Sidewalls. Diagonal Bracing (FEW/BEW ): Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls.
Roofing : Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : Supertech Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Daylight panels (nos. and %) : Polycarbonate Sheet, 2.0mm Thick, 12 Nos. Of Size 2400mm x 600mm Eave Gutter /Flashing/Downpipe: Matching to roof & wall S Type Louvers : 1.0M High S-Type Louvers Is Considered At Both Sidewall Of Building Turbovents : 600mm Throat Dia., 2 Nos. In Each Bay (Total 12 Nos. In Roof) Canopy (height / width / location)
Additional Load : • Additional Load Of 10 Kg/Sqm. On Roof For Services Etc. • Additional Load Of 150 Kg/Rmt On All Around The Periphery Of Sidewall Columns For Cable Tray & Pipe Rack. • Only Brackets & Loading Is Considered For Same In PEB Scope. Mezzanine : Dead Load = 250 Kg/Sqm. Live Load = 300 Kg/Sqm. Mezzanine Area = 79.84 sqm for deck sheeting & 40 sqm for RCC as per drawing Mezzanine Height = As per drawing 0.80mm Thick GI Deck Sheet Is Considered For Mezzanine Area. 1 Nos. Of Staircase Is Considered For Mezzanine Access.
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability Between 5-20% (Medium Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from 1.0M Above FFL. 5. Downtakes are considered upto FFL Level. 6. Framed Opening, Window Opening Which Are Coming In Brickwall Is Not In SIPL ScopeOf Supply, No Arrangement Is Considered For Same. 7. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity. (The total rate includes mezzanine work)
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are Supertech’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). Supertech will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Mezzanine & Decking 0.8mm GI m) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer. ( Rates are inclusive of all operations including design of civil structures, etc.)
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners
Design,manufacture,supply & erection of Pre-engineered Building as per building description & drwaing refr RITES/AP/DC/ARCH/BT/01&02 Bus Terminal shed -2 No. Building Type : Clear Span Width : 12.5.0 Mtrs. O/O Of Steel Line. Length : 50.0 Mtrs. O/O Of Steel Line. No. Of Bay Spacing : As per drawing End Wall Col. Spacing : As per drawing Roof Slope : 1:10 Clear Height : 6.0M Clear Height Under The Knee as per drawing Brick wall height : 3.0Mtrs. Brickwall & Above Cladding All Around The Building. Diagonal Bracing( This details is tentaive likely to be changed) (type/location): Diagonal Rod Bracing Is considered in Roof & Both Sidewalls. Diagonal Bracing (FEW/BEW ): Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls.
Roofing : Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel. Wall : Supertech Single Skin 0.50mm TCT Hi-Rib colour coated Galvalume Profiled panel. Additional Load : • Additional Load Of 10 Kg/Sqm. On Roof For Services Etc. • Additional Load Of 150 Kg/Rmt On All Around The Periphery Of Sidewall Columns For Cable Tray & Pipe Rack. • Only Brackets & Loading Is Considered For Same In PEB Scope.
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability Between 5-20% (Medium Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from 1.0M Above FFL. 5. Downtakes are considered upto FFL Level. 6. Framed Opening, Window Opening Which Are Coming In Brickwall Is Not In SIPL ScopeOf Supply, No Arrangement Is Considered For Same. 7. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity.
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are Supertech’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). Supertech will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners
Design,manufacture,supply & erection of Pre-engineered Building as per building description & Drwing No.RITES/AP/DC/Arch/RS/01 Rummaging shed -1 No. Building Type : Clear Span outer to outer of Roof area as per drawing Width : 7.8 Mtrs. O/O Of Roof Line. Length : 17.0 Mtrs. O/O Of Roof Line. No. Of Bay Spacing : As per drawings Roof Slope : 1:10 Clear Height : 5.5M Clear Height Under The Knee as per drawing (type/location): Diagonal Rod Bracing Is considered in Roof & Both Sidewalls. Diagonal Bracing (FEW/BEW ): Rigid End Frame Frame (Half Bay Loaded) Frame is considered at Both EndWalls.
Roofing : Single Skin 0.47mm TCT Hi-Rib Colour Coated Galvalume profiled Panel.Additional Load : • Additional Load Of 10 Kg/Sqm. On Roof For Services Etc. • Additional Load Of 150 Kg/Rmt On All Around The Periphery Of Sidewall Columns For Cable Tray & Pipe Rack. • Only Brackets & Loading Is Considered For Same In PEB Scope.
NOTE:- 1. Minimum Cold form Thickness Is 1.60MM & Built-Up Is 4.0 MM. 2. Building is Designed for Permeability Between 5-20% (Medium Permeability). 3. Valley Gutter & Metal Downtake Pipe is Designed for Rainfall Intensity of 100mm/Hr. 4. All PEB Steel Column will start from 1.0M Above FFL. 5. Downtakes are considered upto FFL Level. 6. Framed Opening, Window Opening Which Are Coming In Brickwall Is Not In SIPL ScopeOf Supply, No Arrangement Is Considered For Same. 7. All Connections Including Anchor Bolt & Main Connections Are Designed For 1.20 Times Of Actual Forces Instead Of 1.20 Times For Plastic Moment Capacity. (Rates are inclusive of all applications specified above )
DESIGN LOADS Live Load For Roof : 0.75kN/SQM Dead Load For Roof : 0.15kN/sqm Wind speed/pressure : 47 Meter/Second Seismic Zone/Factor : V (0.36) Deflection in Rafter (Vertical) : Span/180 Deflection to Column (Horizontal) : Height/150 Deflection to Purlin : Span/150
Applicable Codes: Primary Member Design - IS:800-2007 (Limit State Design) Without Chapter-12 Secondary Member Design - IS:801-1975 Loads & Load Combination - IS:875-1987 Earthquake Load- IS:1893-2002 (Part-1)-Only Static Analysis Wind Load As Per IS:875-2015 (Part-3) With Terrain Category-2 Slender Sections Are Considered For Web & Semi-Compact Sections Are Considered For Flanges.
List of Inclusions a) Main frame rafters & columns b) Purlin & Girts - Galvanised c) Steel Connectors d) Structural hardware including Anchor bolts & templates. (Templates are Supertech’s property and to be returned back after use) e) Setting of Anchor Bolt – (Physical setting or fixing). Supertech will check dimensional accuracy of anchor bolt set out before casting. f) Roofing Panels (as per description) g) Cladding Panels/Canopy (as per description) h) Eave&Valley Gutter Downtake&DowntakePipe(PVC-150MM-dia) for Building. i) Matching flashing, Ridge Cap j) Sheeting / fixing fasteners, Sealant k) Turbo vents & S-Type Louvers l) Steel finish: Factory applied 1 coat of red oxide zinc chromate primer. (Rates are inclusive of all applications specified above )
Structural Steel Specification a) Primary Steel All primary steel members shall be solid web buildup section in manufactured out of 345 Mpa steel plates. All portals shall be supplied in fully finished and ready to use condition for field assembly. b) Cold formed section These shall be Z/C shaped cold formed section out 275 GSM Galvanised steel stripes conforming to ASTM 570. c) Rod bracing, flange bracing, misc. steel components such as clips etc. shall be out of 240/250 Mpa steel conforming to IS 2062. d) Structural Hardware All primary steel connections shall be established using high tensile Gr. 8.8 fasteners. Steel secondary connections bolt shall be done by Galvanised Gr. 4.6 fasteners
INTERNAL PLUMBING
SANITARY INSTALLATIONS
Providing & Fixing white glazed vitreous china wash basin with, 32mm C.P. brass waste of standard pattern complete including cutting and making good the wall and sealing the sleeves as required including fixing on brackets.
Counter top wash basin
Providing and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providivg and Fixing of 15mm dia. Self closing type C.P. brass pillar tap for wash basin, including cutting and making good the walls wherever required.
Providivg and Fixing of 15mm dia. Self closing type C.P. brass bib cocks with wall flanges for washing area, including cutting and making good the walls wherever required.
Providing, fixing & testing and commissioning of white viterous china large half stall urinal including providing & fixing CI / MS bracket (duly painted with 2 coats of paints over a coat of primer), including 32mm dia CP brass waste with dome type grating complete including cutting and making good the wall and sealing the sleeves as required including fixing on brackets.
Providing, fixing & testing and commissioning of glazed vitreous china flat back urinals partition complete with fixing on wall with dash fasteners complete in all respects with cuttiing of wall and making good the same as directed.
Prividing and Fixing 15mm C.P. brass self closing urinal valve complete with CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange including cutting and making good the walls wherever required.
Providing & fixing adjustable type wash basin for handicap toilet with, 32mm C.P. brass waste of standard pattern complete including cutting and making good the wall and sealing the sleeves as required including fixing on brackets.
Providing & fixing raised toilet seat for handicap toilet of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing CP brass Health faucet with 8mm dia 1 mtr. Long PVC tube and wall hook fixed to wall with rawl plugs and CP brass screws complete.
Providing and fixing (bonut size 24mm, ceramic disc size 19mm and min. body thickness 2mm, nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) 2-way Bib Cock.
Providing and fixing CP brass soap dish 113 mm dia and 43mm deep with fixing handles and concealed fitting arrangement fixed in position by rawl plugs and CP brass screws weighing not less than 300gms.
Providing & fixing CP brass liquid soap dispenser with stainles steel lid and brackets fixed to wooden cleats with C.P. brass screws.
Prividing and Fixing 1.5 feet long connecting hose with CP brass nuts at both ends complete.
Providing and fixing CP brass towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality. 600 mm long towel rail with total length of 620 mm, 66 mm wide and effective height of 88 mm, weighing not less than 900gms.
Providing and fixing CP brass towel ring half circular shape 206 mm long, 132 mm wide with minimum distances of 57 mm from wall face with concealed fittings arrangement of approved quality, weighing not less than 500 gms.
Supplying automatic 'NO-Touch' ABS electric hand-driers complete with all accessories & fittings.
Providing & Fixing 300mm long SS grab bars fixed to wall with rawl plugs and CP brass screws complete.
Providing and fixing Chiller cum Water Dispenser with an inbuilt RO water purifier, fan cooled condenser for fast cooling, double purification by RO + UF with TDS controller suitable to remove even dissolved impurities while retaining essential minerals. Dispenser shall be floor standing design, suitable for water from all sources such as bore-wells, tanks or tap-water. Dispenser shall have water storage capacity of 20 litres and should have corporates Filmtec RO membrane, filter change alarm, Auto-start and Auto-off, Inbuilt Auto-Flushing System, Built-in SMPS that supports wide range of input voltage (200-240V AC) also Corrosion free stainless steel body and Food grade, non-breakable, ABS plastic construction complete with following specifications.
Type: Water Purifier
Purification Capacity: 25 litres/ hour
Max. Duty Cycle: 150 Liters / Day
Input Voltage: 200-240 v AC
Operating Voltage: 24V DC
Providing and fixing stainless steel Antiscratch kitchen sink with double bowl with drain board complet with 32mm dia CP waste, CI or RS brackets compete in all respects. (Size 1210x510 mm bowl depth 200 mm)
Providing and fixing 15mm dia C.P. brass single lever sink mixer (Wall Mounted) with regular swinging spout.
SOIL, WASTE, VENT & RAIN WATER PIPES
Providing & fixing cast brass floor clean out plug with suitable insert keys for opening, male threaded joint with connection of soil/waste pipe with GI., sockets lubricated with grease.
Providing and fixing GI inlet fitting approximately 450 mm long with one or more 32/40/50mm dia.. GI Sockets welded and dipped in hot bitumen complete.
Providing and fixing 100mm dia. GI pipe approximately 450 mm long with one reducer elbow 100x50 mm and dipped in hot bitumen complete.
Providing and fixing 100% stainless steel grating of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works.
FIRE FIGHTING
PIPING & VALVES
Providing and fixing C.I. foot valves including nuts, bolts,1.5mm thick compressed asbestos gasket complete and companion flange as per table " E "in all respects
150 mm dia.
Providing and fixing brass ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified.
25 mm dia.
50 mm dia.
Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station.
Dial diameter 100 mm calibration 0-15 kg/ sq.cm.
Providing and fixing blank flanges as per table 'E' with asbestos gasket, nut, bolts, washers complete
150 mm dia.
Providing and fixing one coat of 4 mm thick PYPKOTE/ COATAK anti-rust pipe protection including primer and lap of 25mm on external buried pipe including surface preparation, complete in all respects.
80mm dia
100mm dia
Excavating trenches by mechinical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil/RBM
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
FIRE HYDRANT ACCESSORIES
Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with " fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 2100x 900 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)
Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. Sheet with single or double glazed front door and locking arrangement, painted "Fire Red" with powder coated paint "Fire Hose" written on front including suitable supports to place 900 mm above ground level, approximately size 750x600x250 mm deep (to house two lengths of canvas hose with couplings, branch pipe and nozzle for external hydrants)
Supplying and fixing of Fire Man's Axe with heavy insulated rubber tested upto 20 KV and confirming to IS :926.
Constructing Solid blocks masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with FRP cover with frame 600x600mm internal dimensions (20 ton load bearing) i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Solid blocks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
SPRINKLERS & ACCESSORIES
Providing & fixing 25mm dia. UL listed gunmetal inspector test and drain valve with integral sight glass connected to drain line complete in all respects.
FIRE PUMPS & ACCESSORIES
Air Vessel for Fire Pump:
Providing and fixing of air vessel of the following specifications fabricated with MS sheets.
a. Diameter : 400 mm
b. Shell Thickness: 8 mm
c. Dish Ends : 10 mm
d. Height : 1500 mm
e. Finishing: Two coats of red enamal
paint over primer out side and two
coats of epoxy coating inside.
f. Material of construction: M.S
g. Test Pressure: 22 Kg/Sq.Cm.
h. Height of supporting legs: 400 mm
i. Quantity
Note: Contractor should submit general arrangement drawings before fabrication of vessel and ultrosonic test report to be submitted on supply of vessel and test to be conducted at the presence of Plumbing-In-Charge.
Providing and fixing liquid level controller for fire pump to stop fire pump in case of low level of water in tank , cost of conduit, cable and panel including making connection to pump panel and commissioning complete.
Float type Sensor with panel
Installation
Providing and fixing liquid level controller for tubewell pump to start both the tubewell pumps in case of low level of fire water in tank, stop manually (when fire extinguished) also provision of over riding domestic water pumps inter-locking in case of fire, cost of conduit, probes or float switches cable and panel including making connection to pump panel and commissioning complete.
Float type Sensor with panel
Installation
Supplying & laying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cable as per specification in cable trays, clamped includes anchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. (For Jockey Pump)
3 core 4 sqmm
Supplying & laying of following 1100 volt grade PVC insulated sheathed XLPE aluminium conductor armoured cables as per specification in cable trays, ducts, clamped includes anchor fastners to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning.(For Main Pump 2 Runs)
3 core 35 sqmm
Cable end termination of the following PVC insulated sheathed PVC/XLPE aluminium conductor armoured cables of 1100 volt grade including supplying and fixing of crimping aluminium lugs, double compression glands with earthing facility at both ends of cables etc. complete as required
3 core 35 sqmm Alumnium conductor cable
3 core 4 sqmm Copper conductor cable
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels ,slotted angle, etc.) including cutting to size, drilling ,welding or insert plates including cost of (Hilti) fasteners, clamp in RCC structural members as directed, including two or more coats of synthetic enamel paint over one coat of primer after surface preparation including cutting and making good walls.
Providing and fixing resilient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table "E" complete suitable for working pressure of 15 Kg/sqcm. And temperature of 50°c.
80 mm dia.
100 mm dia.
150 mm dia.
FIRE EXTINGUISHERS & MISC. ITEMS
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
Providing and fixing mechanical foam type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked finished externally with red enamel paint and fixed to wall with brackets complete with internal charger.
9 liters capacity. (IS. 15683)
Providing and fixing water Co2 (ISI marked) extinguishers including all accessories as per IS specification, finished externally with red enamel paint and fixed to wall with brackets complete with internal charger.
Capacity 9 liters.(IS:15683)
Providing and fixing ABC powder type fire extinguishers consisting of welded M.S. cylindrical body automatic modular ABC powder type extinguisher actuated through a sprinkler head mounted on The extinguisher body finished externally with red enamel paint and fixed to ceiling with brackets complete with internal charge. (For Transformer/DG/LT panel room)
Capacity 10 Kg.(IS:15683)
Providing and fixing ABC powder type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked finished externally with red enamel paint and fixed to wall with brackets complete with internal charger.
Capacity 6 Kg (IS. 15683)
Providing and fixing wet chemical type (ISI marked) fire extinguishers consisting of welded Stainless steel body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked and fixed to wall with brackets complete with internal charger. (For Kitchen Area)
Capacity 4 Kg. (IS:15683)
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, trolly mounted, confirming to IS : 15683 finished externally with red enamel paint complete with internal charge. Capacity 22.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
Providing and fixing mechanical foam type (ISI marked) fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle, trolly mounted ISI marked finished externally with red enamel paint complete with internal charger.
50 liters capacity. (IS. 15683)
EXTERNAL PLUMBING
PUMPS
Providing, fixing and testing of skid mounted pumping system comprising of :-
Horizontal centrifugal pumping set with CI body and bronze impeller with stainless steel SS 304 shafts connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply.
GI Suction and delivery header with Ball valves Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement.
Complete set system to be mounted on a common base frame and shall follow following duty.
Domestic Water Transfer Pump
No. of Pumps: 2 (1 Working + 1 Stand by )
Capacity : app.200 lpm
Head : 50m
Filter/Softener Feed Pump
No. of Pumps: 2 (1 Working + 1 Stand by )
Capacity : app.200 lpm
Head : 25m
Pressure Filter (Domestic Water)
Providing and fixing vertical pressure filter with dual media filter (comprising of minimum 1050mm bed depth of graded sand gravel and Anthracite) fabricated from high performance M.S plate of minimum 6mm thick for shell & 8mm thick for dished ends with top and bottom flanged openings including top and bottom hub and lateral distribution and collection system complete with initial charge of filter media, face piping, valves, accessories, painting, testing and commissioning complete.(Tested to 6 Kg/m2)
Discharge : 12000 lph
Filtration Rate : 15000 lit./m2/h
Suggested dia app. : 1.000 m
Activated carbon Filter (Domestic Water)
Providing and fixing vertical activated carbon filter comprising of activated carbon filter media fabricated from high performance M.S plate of minimum 6mm thick for shell & 8mm thick for dished ends with top and bottom flanged openings including top and bottom hub and lateral distribution and collection system complete with initial charge of filter media, face piping, valves, accessories, painting, testing and commissioning complete.(Tested to 6 Kg/m2)
Discharge : 12000 lph
Filtration Rate : 15000 lit./m2/h
Suggested dia app. : 1.000 m
Water Softener
Providing and fixing ‘Cation’ ION exchange water softener fabricated from minimum 8mm thick M.S. plate on shell and 10mm thick M.S. plate on dished ends complete with initial charge of filter media and ION exchange resins, face piping accessories, piping testing and commissioning complete with resins of approved quality and make and brine tank of required capacity. (Bidder must indicate type and quantity of resin used and quantity of salt required per regeneration).
Minimum expected rate of flow: 12000 lph
Total soft water to be produced between two regeneration: app. 85 Cu.m
Expected raw water hardness : app. 250-300 ppm(Hardness values are assumed. Please get it tested before execution)
Expected treated water hardness: less than 100 ppm
Max. working pressure : 4 Kg/cm2
Total soft water to be produced between two regeneration: app. 85 Cu.m
Providing and fixing M.S salt saturator, internally rubber lined as per requirement and externally painted with suitable anti-corrosive paint, with all required accessories for holding and supplying salt for softener complete in all respects, with electrically operated stirrer and of capacity 500 litres.
Panel shall be supplied with P&I based online MIMIC display with LED's at all specific drive /operation to enable Visual Display of Complete pumps activity on Panel front.
For domestic water transfer pumps, filter feed pumps, auto chemical doser and sump pumps etc. in plant room.
One incoming main isolation 125A TPN MCCB.
150 A TPN Fully taped copper bus bar in a separate bus bar chamber.
2 Nos. 20 A TPN MCB outgoing for domestic water transfer pumps with 2 Nos. DOL starter.
Motor controller with float swich and controll wiring for switch on and swich off the pumps. Relay for cyclic operation of domestic water transfer pumps. Pump working sequence should change after every operation.Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter also consist of Single phase preventors complete with auto manual swiches, Voltmeter/Ameter, Indication lights.
2 Nos. 16 A TPN MCB outgoing for filter feed pumps with 2 Nos. DOL starter.
Motor controller with float swich and controll wiring for switch on and swich off the pumps. Relay for cyclic operation of filter feed pumps. Pump working sequence should change after every operation. Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter also consist of Single phase preventors complete with auto manual swiches, Voltmeter/Ameter, Indication lights.
1 No. 32 A TP MCB for sump pumps
Neon phases indicating lights on the incoming mains.
All internal wiring colour coded from incoming mains to various switchgear, starter, meter, indicating lamp and bus bar. All the cable entry to the panel shall be from the top.
(All for above from item (a) to (k) complete set). (The shop drawing to be prepared and approved before fabrication)
Providing and fixing motor pump controller cum water level indicating panel in powder coated sheet metal box in 16 gauges M.S including the following:
Electronic water level controller working on magnetic type sensing probes with necessary length of armored cable up to control panel.
Electronic minimum 4-level indicator with magnetic type sensing probes and necessary length of armored cable upto control panel.
Arrangement of alternate switching mechanism for operational and standby pumps.
For Water level indicators with following details:
Underground water tanks
Minimum 4 level Multi level indicators with magnetic type sensor probes complete.
Centralized overhead water tank
Minimum 4 level Multi level indicators with magnetic type sensor probes complete.
For water level controllers with electronic sensing probe complete in all respect for following functions.
i) Tubewell Water Pumps
To cut on at low level in raw water U.G tanks. And cut off at high level in U.G raw water tank.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete (The cost of flanges will be paid separately).
65mm dia
80mm dia
Providing and fixing C.I double flanges suction strainer bucket type/ “Y” type including, nuts, bolts and 3mm thick rubber insertion complete.
65mm dia
Providing and fixing butterfly valves, wafer end type class PN 1.0 as per I.S:13095 - 1991 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box)
65mm dia nominal bore.
Providing and fixing M.S. slotted cable tray supported from ceiling at intervals of 60cms on both ends including cable clips with nuts and bolts welding of support rods with ceiling inserts or through dash fasteners cutting and making good complete.
300mm wide
150mm wide
Providing and fixing M.S. structural work fabricated from standard section e.g. M.S rounds, angles, channels, plates including cutting to size, drilling, welding fixing and welding to insert plates in RCC structural members or through dash fasteners as per site conditions as directed by Engineer-in-charge including cutting and making good the walls, ceilings and floors (for pipe supports, clamps etc.)
Submersible pumps
Providing, fixing and testing of submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to oil filled submersible motor suitable for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables. Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Main incomer MCB, Outgoing MCBs, Single phase preventors complete with auto manual swiches, Voltmeter/Ameter, Indication lights, Controller for dry run protection. All pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect.
(one working+One Standby)
(Solid handiling capacity 25mm)
Capacity : 225 lpm (Each)
Head : 12 m
HP (Approx) - 1.0 HP
UV Treatment:
Providing and fixing automatic UV Treatment system consisting of electronic system, suitable to doze UV to a flow of water of maximum 12000 lph. against a pressure of 40-50psi complete with all standard accessories.
SEWAGE TREATMENT PLANT
Anticipated effluent parameters before treatment:
BOD5 days 350 mg/lt
SS 450 mg/lt.
COD 700 mg/lt.
T-N upto 35 mg/lit.
P upto 10 mg/lit.
Desired Sewage discharge standard after outlet of ACF are as below:
TSS : < 20 mg/lit
BOD5 days : < 10 mg/lit
COD : <50 mg/lit
TN : < 10 mg/lit.
Phosphorus : Less than 1 mg/lit.
Sewage treatment plant shall include the following Civil Units :
Sump Pit Cum Bar Screen chamber
Foundation for Electromechnical
Supply, installation, testing & commissioning of 2 Nos SS 304 (10 mm) Perforated Coarse Type Screen Size 600mm x 600mm with suitable garbage lifting arrangement.
Supply, installation, testing & commissioning of level switch for automatic operation of system.
Supply, installation, testing & commissioning of Submersible, non clogging/cutter type pumps capable of handling solids minimum 20 mm having CI casing & impeller with SS Shaft complete with mechanical seal & all accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation cock. Pumps shall have following duty. Make: Wilo/Leo/Lubi
Submersible Sewage Transfer Pumps (1W+1S) (EQT)
Flow Rate (each pump) = 4 m3 / hr
Head = 8-10 Mtr
Submersible Sump Pumps (1W+1S)
Flow Rate (each pump) = 6 m3 / hr
Head = 10-12 Mtr
Cost shall be inclusive of PVC Flexible Pipe 25 mm dia , rope for lifting pump from sump to outside.
Providing and fixing horizonal,centrifugal sludge recirculation pump . The pumps shall have CI casing, CI Impeller with mechanical rotary shaft seal. Motor to be suitable for including all necessary piping valves and other accessories complete as required. Solid Handling capacity 10-15mm
Sludge Recirculation Pump (1W+1S)-MBBR To Anoxic
Capacity (each pump) : 16 Cum/hr.
Head :8-10 mtrs.
Sludge Transfer Pumps (1W+1S)
Capacity : 5 Cum/hr. (each pump)
Head :8-10 mtrs.
Make : Kirloskar/M&P/Leo or equivalent
Air diffusion system shall include the following:
Supply, installation, testing & commissioning of twin lobe, rotary Air blower capable of delivering 75 cum/hr of free air at required pressure driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Blower Everest/Beta/Akash/Rootech
Air Blowers (1W+1S)
Flow Rate (each) = 75 m3 / hr @ 5000mmwg
Air Grid in UPVC complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, paint,supports & clamps, puddle flanges etc cutting chases & making good the wall wherever required. Contactor to submit detailed P & I indicating their proposal.
Non-clog type air dispersion system capable of handling required air with oxygen transfer efficiency. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily. (Coarse and Fine bubble membrane diffusers, Air dispersion system as per requirement capable of handling 3-5 cfm air with oxygen transfer efficiency of 3-4% per/meter or as per requirements)
Air dispersion system shall be provided for MBBR Tanks & Equalization Tank.
Providing and fixing all interconnecting piping (as described below) and isolation control valves for making the system complete. The piping material shall be MS 'B' class.
MS Epoxy : Non submerged air piping & pumped effluent riser ( non-submerged)
uPVC/PVC: Submerged air line.
uPVC/PVC Piping : Interconnecting pipe line after delivery header of pump / filter
Supply, installation, testing and commissioning of MBBR media of polypropylene with a specific density of more than 0.97 gm/cc and with bio surface area not less than 400 sq.m/cu.m and life expectation of minimum 10 years. (MBBR media System to be in two reactors).
Supply, installation, testing and commissioning of PVC tube deck settling media to be installed in Tube Settler Tank alongwith retainer plates and suitable sludge removal arrangement either by pumps or any other suitable arrangement (Vendor will be quote with arrangment detail). Capacities, length, width,depth, of the media shall be enough for proper functioning of STP.
Supplying, installing, testing & commissioning of centrifugal pumps, CI body, CI impeller. motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer at suction. The pump shall be suitable for 415±10% volts 3 phase AC supply.
Filter feed pumps: (1W+1S)
Capacity : 4 Cum/hr.
Head : 25-30 Mtrs
Irrigation Water Transfer pumps: (1W+1S)
Capacity : 9 Cum/hr.
Head : 40-50 Mtrs
Supplying, installing, testing and commissioning of MSEP vessel filter with all necessary accessories. Filter shall be suitable for minimum working pressure of 5 kg / cm2 and shall include media, standard fittings like pressure gauges, sampling cock, rinse drain, vacuum breaker etc.
Multigrade pressure sand filter
Flow rate : 4 Cum/hr
Filtration rate: 15 m3/hr/m2
HOS : 1500 mm
filtering sand, anthracite, pebbles and gravel media
MOC: MSEP
Activated Carbon Filter
Flow rate : 4 Cum/hr
Filtration rate: 15 m3/hr/m2
HOS : 1500 mm
Activated carbon, filtering sand, anthracite, pebbles and gravel media
MOC: MSEP
Supplying, installing, testing and commissioning of Chlorine dosing system (1W+1S)2 Nos. consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing pump having variable flowrate of 0-12 lph. The motor shall be suitable for operation at 240 V/single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke control.
Dosing Pump: Toro/Prominent/Grundfos
Supply, installation, testing and commissioning of Filter Press with 12 nos plates of plate size 450x450mm with interconnecting piping, poly dosing system (1W+1S)2 Nos. and screw pump (1W+1S) 2 Nos. of 0.5 cum/hr capacity and 40m head.
List of Pre Fabricated Tanks in MSFRP (MS Thickness side 5mm, Bottom 5mm)
Equlization Tank including O&G Trap - 1 Set - 30KL + Free Board
Anoxic Tank 1 No. - 7 KL + Free Board
MBBR Tanks 2 Nos. - 11 KL + Free Board
Tube Settler Tank 1 No. - 8 KL + Free Board
Chlorine Contact Tank 1 No. - 10 KL + Free Board
Sludge Holding Tank 1 No. - 8 KL + Free Board
Treated Water Tank - 50 KL + Free Board
Insrtumentation
Supply and fixing of following instrument
Providing and fixing full bore type Electro-magnetic flow meter of 25 mm dia designed at maximum speed of 3-4 m/sec at the sewage inlet.
Providing and fixing Turbine type flow meter designed at maximum speed of 3-4 m/sec at the sewage outlet
Providing, installing, testing and commissioning of Online digital type pH meter.
Providing and fixing of suitable size pressure gauge boudron type glycerin filled.
Supply, installation, testing & commissioning of Mixer for anoxic tank complete in all respect.
Contractor shall include all electrical & mechanical items as required to operate the system and also include in his rates level controller, electrical wiring, cables, able trays, earthing main control panel and connection to be various equipments and other accessories complete as required. Only main power supply upto the STP main control panel shall be provided by the owner through other agencies. The specifications for Electrical Panel given below.
STP Contractor should follow the norms as applicable.
Bypass arrangement shall be provided as shown in the drawings such that equalization tank pump can be used to pumpout sewage up to 6 m away from the plant in case of maintenance of STP. Wherever more than two pumps or blower is proposed, arrangement should be made in such a way that each equipment can take care of any of the stream.
Electrical Panel- Motor Control Centre
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 16 gauge CRCA sheet steel. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coate of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels.
Motor Control Centre
Incoming
Required Capacity TPN MCB with the following accessories:
c) Phase indicating lamps shall be protected by 2 amp SP MCB 3 sets.
Bus Bar
Required Capacity TPN (15 KA) Al bus bar with heat shrinkable insulation sleeves.
Outgoing
b) All MCCB's / MCB's shall be of 15 KA breaking capacity and suitable for motor duty application.
c) All motor starters shall be provided with Auotmatic level controller.
d) DOL starters shall be used for moters below 7.5 HP and Star-Delta Starters for other motors.
e) Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/ pumps as described in sub head-A with provision for all future pump air blower etc.
Supplying, installing, testing & commissioning of Cables , Conector, Cable Trays, to make Electrical Installation Complete.
Cable
CableTray:
SEWERAGE SYSTEM
Providing and laying non-pressure NP3 class (Medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
150 mm diameter
200 mm diameter
250 mm diameter
Constructing Solid blocks/brick masonry circular type manhole 0.91 m internal dia at bottom and 0.60m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with FRP. cover and frame (Load bearing 20 Ton) 600 mm internal diameter conforming to EN 124 fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
Solid blocks/bricks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
Solid blocks/bricks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Constructing Solid blocks/brick masonry circular manhole 1.22 m internal dia at bottom and 0.60 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
1.68 m deep with FRP. cover and frame (Load bearing 20 Ton) 600 mm internal diameter conforming to EN 124 fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
Solid blocks/bricks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :
Solid blocks/bricks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Constructing Solid blocks/brick masonry circular manhole 1.52 m internal dia at bottom and 0.60 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
2.30 m deep with FRP. cover and frame (Load bearing 20 Ton) 600 mm internal diameter conforming to EN 124 fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
Solid blocks/brick of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m.
Solid blocks/brick of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Procuring and installing LDPE septic tank with provision of sludge chamber and clear water chamber complete in all respects with following user provisions :
25 Users
Excavating trenches by mechinical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil/RBM, and then returning the soil/RBM as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil/RBM as directed, within a lead of 50 m :
All kinds of soil/RBM
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
EXTERNAL WATER SUPPLY
Constructing Solid blocks masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with FRP cover with frame 600x600mm internal dimensions (20 ton load bearing) i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Solid blocks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Constructing Solid blocks masonary chamber 90 cm X 90 cm X 100 cm inside brick work in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) for sluice valve with 600x600mm internal dimension(20 Ton load bearing) FRP cover with frame and RCC top slab 1:2:4 mix(1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3(1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.
Solid blocks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Constructing Solid blocks masonary chamber 30 cm X 30 cm X 50 cm inside with brick work in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) for sluice valve with 300x300mm internal dimension(2.5 Ton load bearing) FRP cover with frame and RCC top slab 1:2:4 mix(1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3(1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.
Solid blocks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete.
150 mm dia
Providing and making connection of garden hydrant with MDPE pipe including saddle of pipe diax25mm dia and fixing on pipe complete in all respects.
Providing and fixing Blue Coloured MDPE pipes of PE 80 Grade stabilized including all MDPE electrofusion fittings i/c support at 1.0mm c/c & testing of joints complete as per direction of Engineer in Charge
PN - 16 Pipe, 20 mm OD PE80 ISO : 4427
PN - 12.5 Pipe, 25 mm OD PE80 ISO : 4427
PN - 12.5 Pipe, 32 mm OD PE80 ISO : 4427
PN - 12.5 Pipe, 40 mm OD PE80 ISO : 4427
PN - 10 Pipe, 50 mm OD PE80 ISO : 4427
PN - 6 Pipe, 63 mm OD PE80 ISO : 4427
PN - 6 Pipe, 90 mm OD PE80 ISO : 4427
PN - 6 Pipe, 110 mm OD PE80 ISO : 4427
PN - 6 Pipe, 160 mm OD PE80 ISO : 4427
Excavating trenches by mechinical/manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil/RBM
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
TUBE WELL
Supplying & installation of submersible pump set directly coupled with 7.5 HP motor nominal speed 2900 RPM suitable for operation on 3-phase, 50 cycles, 400 + 5% volts A.C. power supply to give yield of 30000/24000 LPH at a head of 50/70 mtrs.
Total head = 50/70 Mt
Flow rate = 36000/30000 LPH
H P = Minimum 7.5 HP
(Or as per site condition)
Supply, installation and commissioning of panel board duly wired made of 16/18 SWG sheet including fixing of the same in wall/floor on angle iron frame as per site conditions, and fitted with the following:
1 No. DOL starter.
1 No suitable range voltmeter size 96 mm.
1 No suitable range ammeter size 96 mm.
1 No. single phase preventer.
3 Nos MCB for lamps, ammeter and voltmeter.
3 Nos. indicating lamps
1 No MCB of suitable range
Push button ON/ OFF switch - 1 No.
Supply & installation of 80 mm dia column pipe made out of 80 mm dia GI including the cost of fittings complete in all respect 'B' class pipe.
Providing & fixing heavy duty PVC sheathed copper conductor 1100 volts grade cables with clamps complete in all respect.
Control cable for low water level guard 2 core 2.5 Sq.mm.
Power cable 3 core 4 Sq.mm.
OVER HEAD WATER TANK
Constructing Solid blocks masonary chamber 90 cm X 90 cm X 100 cm inside with brick work in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) for sluice valve with 600x600mm internal dimension(20 Ton load bearing) FRP cover with frame and RCC top slab 1:2:4 mix(1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3(1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.Solid blocks of approved quality and class designation 5 having compressive strength of 4-6 N/sq.mm.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete.150 mm dia
Minimum 4 level Multi level indicators with magnetic type sensor probes complete.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete (The cost of flanges will be paid separately). 80mm dia
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
FLAG POST
Supply ,Installation,Testing and commissioning of 30.5 Mtr hot dip GI and PU coated Flage Mast at Integrated Check Post ,Banbasa.
GABION
Providing & making of Gabion structure of size (2x1x1)m with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012, MoRT&H's 5 th revision clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ±2%), Zinc+10% Al alloy+Polymer coated, Mesh wire diameter 2.7/3.7mm (ID/OD), mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge.
ROAD WORKS
Construction of embankment with approved material (RBM) obtained from approved quarry/river with all lifts and leads, transporting to site, spreading, grading to required slope as per Relavent MoRTH Specification & direction of Engineer -in- charge (maximum size of material 90mm).
Construction of subgrade with approved material obtained from approved quarry/river/borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2 (MoRTH Specification) and as per direction of Engineer -in- charge (maximum size of material 4.75mm)
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. (Grading-IV MoRTH Specification)
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. (Grading-V MoRTH Specification)
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver (Table 400-13 MoRTH Specification)
Providing and laying 100mm thick factory made cement concrete interlocking paver block of M-45 grade by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer - in - charge.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport for all lead & lift, also including ramming and watering of the earth in layers not exceding 20 cm thickness, in other areas, embankment, etc. complete as per direction of Engineer - in - charge
PLAY COURT
Supplying and laying polythene sheet (150g/sq.m) over damp proof course or below flooring or roof terracing or in foundation / foundation trenches. Ocean HDPE Liner 180 Micron, 150
Providing and installation of Basketball Post – Made Of 8” Round Pipe Finished With High Quality PU Paint ,3.2 Mtr. Extension With 25 MM A Grade Malaysian Board With Dunking Ring With Net .
Providing and installation of Volleyball Post – Made Of 4”Round Pipe With High Quality Paint And Height Adjustable With Net with pole
Conducting plate load test of single pile upto specified capacity in accordance with IS:2911-Part-IV including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test. Etc with all labour, material, tool & plants ,equipment, machinery etc complete as per drawing and specification as directed by Engineer.
Providing and fixing G.I fabricated hot dipped galvanized coating in factory after fabrication puddle flange comprising of 700 mm (or as per tank wall thickness) long G.I class 'C' pipe (screwed end up to 50 mm & flange end for more than 50 mm dia) with 6 mm thick G.I plates of required size as given in detailed drawing including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter.
25mm dia
40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Horticulture
Boundary Plantation
Boundary plantation wlth Shisham (Rosewood) species (suitable for the ground condition), Perimeter= 2 km, Diagonal plantation to be done with plant to plant spacing of 3.5 mtr, total no. of plant = 572
Pit preparation for 572 pits (size of pits : 45cm * 30cm * 30cm)
Transportation & Plantation of Shisham Plants
Purchase and Transportation of seedling & vemicompost
Shisham Plants Purchase, grown in polytube (3"*7")& height is 2-3 feet. (10% extra plants for mortality & replacement)
630 Plants with polytube (3"*7") transportation by pickup van (loading and unloading) from nursery to plantation site about 7 km (750 seedling/van )
Vermicompost purchase (Per plant 1 kg)
Organic Nutrients (Per plant 1 kg)
Transportation of vermicompost & organic nutrients within site & mixing into pit.
Supply of Drip Irrigation pipes with 2 holes of 8 LPH per pit includes all the necessary accessories as per the site requirement
Supply of Valves, connectors & Pipe along with jointers and all required items at 20 points from the 250 mm irrigation line. Average distance from the mainline to be taken as 10 mtr
Installation of Drip irrigation pipes with applicable connectors from the main line
Installation of Drip irrigation pipes along with supply of necessary accessories as per site requirement
Gardening with show plants
SHOW PLANTS PURCHASE, TRANSPORTATION & PLANTATION
Flowering plants (Perennial - Bougainvillea), 2-3 feet height
Medium size evergreen & other tree species (Perennial), 2-3 feet height - Raphis Palm
Vermicompost purchase (Per plant 1 kg)
Organic Nutrients (Per plant 1 kg)
Transportation of vermicompost & organic nutrients within site & mixing into pit.
Transportation & Plantation of Perennial Plants & Evergreen Plants
Pit preparation for 763 pits (size of pits : 45cm * 30cm * 30cm)
Supply of 2 line of Drip Irrigation pipes with inbuilt holes of 8 LPH per pit ensuring water availability to the plants. Includes all the necessary accessories as well as per site requirement
Supply of Valves, connectors & Pipe along with jointers and all required items at 10 points from the 250 mm irrigation line. Average distance from the mainline to be taken as 10 mtr
Installation of Drip irrigation pipes with applicable connectors from the main line
Installation of Drip irrigation pipes along with supply of necessary accessories as per site requirement
Natural live hedge perennial plant (Golden Duranta, Anarmi, Mini-exora, Mini-taggar) plantation (Perimeter is 13320 feet, plant to plant spacing = 6 inch, plant size 1.5-2 feet)
Natural live hedge plant purchase
Vermicompost purchase (Per plant 0.25kg)
Organic Nutrients (Per plant 0.25kg)
Transportation of vermicompost & organic nutrients within site & mixing into pit.
Transportation & Plantation of natural live hedge plants
Pit preparation for 26640 pits (size of pits : 30cm * 15cm * 15cm)
Supply of 2 line of Drip Irrigation pipes with inbuilt holes of 8 LPH per pit ensuring water availability to the plants. Includes all the necessary accessories as well as per site requirement
Supply of Valves, connectors & Pipe along with jointers and all required items at 60 points from the 250 mm irrigation line. Average distance from the mainline to be taken as 10 mtr
Installation of Drip irrigation pipes with applicable connectors from the main line
Installation of Drip irrigation pipes along with supply of necessary accessories as per site requirement
Monitoring (Technical assistance), Care and maintenance of whole plantation & gardening work for 12 months
Supervisor 1 person for 12 months salary
Caretaker (4 person for 12 months, salary)
Supervisor & Caretaker dress (5 person)
Bicycle purchase ( 1 Bicycle/ caretaker) for caretaker & supervisor
Compost & other nutrients for plants 70% of what was applied at the time of plantation
Irrigation to the planted grass and plants as per need
Necessary instruments, equipments etc. purchase
Water tanker trip as per site requirement
Bidder Name
Amount
Dineshchandra R Agrawal Infracon Pvt. Ltd. (GSTN-24AABCD9523D1Z0) BID ID -831282
COMT CONSTRUCTIONS PRIVATE LIMITED (GSTN-07AAACC4019L2ZO) BID ID -831363
Ircon International Limited (GSTN-NA) BID ID -830778
Description of Work / Item(s)
Amount
SCHEDULE-IV
ELECTRICAL ITEMS NON DSR ITEM
SUBHEAD - 1 - (SUPPLY & INSTALLATION OF FITTINGS AND FANS)
Supply, Installation, Testing & commissioning of recessed 2' X2' LED luminaire, Housing CRCA, Efficacy >=100lm/w having a minimum system level lumen package of 3600 lumens ,IP 20 protection,isolated driver etc. complete in all respect as required.
Supply, Installation, Testing & commissioning of surface 2' X2' LED luminaire, Housing CRCA, Efficacy >=100lm/w, having a system level lumen package of 3600 lumens with IP 20 protection,isolaed driver etc. complete in all respect as required .
Supply, Installation, Testing & commissioning of Pressure Diecast LED Bulkhead 10W (>=700lumens) with Efficiency 70lm/w Bulk head luminaire for interior & exterior use, complete in all respect as required.
Supply, Installation, Testing & commissioning of Pressure diecast Aluminium housing Surface Mounted Light suitable for 18W(>=1567 Lumen Output) LED Downlight complete in all respect as required.
Supply, Installation, Testing & commissioning of pressure diecast aluminium12W (>=1200 lumen output) recessed downlighter LED luminaire complete in all respect as required.
Supply, Installation, Testing & commissioning of Surface / suspended Mounted linear Light suitable for 20 Watts (>=2000 lumens) LED Extruded Aluminium housing, complete in all respect as required.
Supply, Installation, Testing & commissioning of 40 W surface / suspended linear 4ft LED luminaire, Housing Extruded Aluminium, Efficacy >=100lm/w, having a system level lumen package of 4000 lumens and IP 40 protection,driver etc. complete in all respect as required .
Supply, Installation, Testing & commissioning of Surface / suspended Mounted Light suitable for 80W with 10400Lm LED highbay complete in all respect as required.
Supply, Installation, Testing & commissioning of Pressure diecast Aluminium housing Surface Mounted Light suitable for 12W(>=1000 Lumen Output) LED Downlight complete in all respect as required.
Supply, Installation, Testing & commissioning of Bollard light made of extruded to redefine landscapes with better light quality, 11W and enhance architectural design rated IP 65 complete in all respect as required.
Supplying, installation, testing and commissioning of wall bracket fan 400 mm sweep fitted with inbuilt regulator complete with wire guard and fixing arrangement on wall complete in all respect as required.
Supply,Installation, Testing and commissioning of 600 mm dia heavy duty Air Circulator Fan to be mounted on coulumn complete in all respect.
Supplying of following size of single phase 240 V A.C Exhaust fan heavy duty complete with motor, blade frames with louvers as required.
250 mm Plastic Type
300 mm Plastic Type
380 mm Metallic Type
450 mm Metallic Type
SUBHEAD - 2- (BOARDS, DISTRIBUTION BOARDS AND CABLES)
Supplying and fixing following rating 415 Volt DP MCB in sheet steel enclosure with phase indication lamps complete with connections, testing and commissioning etc. as required.
40 Amp 415 V, DP MCB
63 Amp 415 V, DP MCB
Supplying and fixing following rating 415 Volt MCCB/MCB in sheet steel enclosure with phase indication lamps complete with connections, testing and commissioning etc. as required.
63 Amp 415 V, TPN MCCB
40Amp 415 V, TPN MCB
63 Amp 415 V, TPN MCB
MAIN BOARD For PTB BUILDING (GROUND FLOOR) (NORMAL CUM ESSENTIAL)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 630A 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
2 No. 150A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 100A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
6 Nos. 63A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
3 Nos. 63A DP MCB 10 kA
SUB BOARD For PTB BUILDING (FIRST FLOOR) (NORMAL CUM ESSENTIAL)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 250A 4 strip Al. Busbar complete interconnection, bottom with MS chennel,. Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
4 No. 80A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 63A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
3 Nos. 63A DP MCB 10 kA
HVAC Panel For PTB BUILDING
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 800A 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
11 No. 80A 4P MCCB 16 kA with adjustable thermal magnetic O/L & S/C release & handle.
11 Nos. 25A 4P MCCB 16kA with adjustable thermal magnetic O/L & S/C release & handle.
3 Nos. 63A DP MCB 10 kA
MAIN BOARD FOR CUSTOM OFFICE GROUND FLOOR) (NORMAL CUM ESSENTIAL)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 630A 4 strip Al. Busbar complete interconnection, bottom with MS chennel,. Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
2 No. 150A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 100A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 63A 4P MCCB. 25 kA with thermal magnetic O/L & S/C release & handle.
2 Nos. 63A DP MCB 10 kA
SUB BOARD FOR CUSTOM OFFICE (FIRST FLOOR) (NORMAL CUM ESSENTIAL)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 250 A 4 strip Al. Busbar complete interconnection, bottom with MS chennel,. Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
4 No. 100A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 63A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
2 Nos. 63A DP MCB 10 kA
HVAC Panel For Custom BUILDING
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 800A 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
11 No. 80A 4P MCCB 16 kA with adjustable thermal magnetic O/L & S/C release & handle.
11 Nos. 25A 4P MCCB 16kA with adjustable thermal magnetic O/L & S/C release & handle.
3 Nos. 63A DP MCB 10 kA
Main Panel for Jawan Barrack and Watch Tower
Design, manufacture, supply, installation, testing and commissioning of compartmentalised wall mounted / floor mounted Cubical Panel fabricated out of 2 mm CRCA sheet dust & vermin proof duly phosphatized & powder coated. The sheet steel shall undergo minimum seven tank treatment the board includes 415 V electrolitic Aluminium Bus Bar 300 Amp TPN, complete with Termaination Box for incomer,interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required.
Incomer
Outgoing
2 No.s 160 A 4P MCCB 25 KA with adjustable thermal magnetic O/L & S/C release & handle.
6 No.s 100 A 4P MCCB 25 KA with adjustable thermal magnetic O/L & S/C release & handle.
3 No.s 63A 4p MCCB 25kAwith adjustable thermal magnetic O/L & S/C release & handle.
2 Nos. 63A DP MCB 10 kA
MAIN panel FOR OFFICER'S BARRACK & Gate Post
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 200 A, 4 strip Al. Busbar complete interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
6 No. 125A 4P MCCB 16 kA with adjustable thermal magnetic O/L & S/C release & handle.
2 No. 63A 4P MCCB 16 kA with adjustable thermal magnetic O/L & S/C release & handle.
2 No. 63A DP MCB 10 kA
Main Feeder Pillar-2,Mahilla Barrack, Residential Quarters, Basket Ball Court, Dining Hall, Parade Ground,Volly ball Court, Gate Post, Street Light , Weigh Bridge
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 150 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
2 No. 80A 4P MCCB 25 kA with adjustable thermal magnetic O/L & S/C release & handle.
6 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
Main Feeder Pillar-3, HM(1 to 5), Entrance Gate-1, Security Post(4)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 150 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
10 No. 63 A 4P MCCB 16 kA with adjustable thermal magnetic O/L & S/C release & handle.
6 No. 63A DP MCB 10 kA
Main Panel for Feeder Pillar-1(SFP-1,SFP-2,High Mast(6 to 9),Animal Quarantine+Animal Shed,staff entry
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 400 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
4No. 125 A 4P MCCB 25 kA with adjustable thermal magnetic O/L & S/C release & handle.
8 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
Sub Feeder Pillar-1 and 2
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 400 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
10 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
5 No. 63A DP MCB 10 kA
5 No. 40A DP MCB 10 kA
Main Feeder Pillar-4(Toilet, W Tower(2 nos.), Porter rest Area,, Inspection shed,Litigationshed, ware House, High Mast(10 to 14)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 300 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
4 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
9 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
Main Building Panel for Inspection shed/Litigationshed/ ware House
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 150 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
6 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
Main Feeder Pillar-5( SFP-5/1,SFP5/2, Fumigation Shed, Porter Rest Area, Toilet, High Mast15 to 20)Toilet, W Tower(2 nos.), Porter rest Area,, Inspection shed,Litigationshed, ware House, High Mast(10 to 14)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 400 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
2 No. 125A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
2 No. 80A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
11 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
Main Feeder Pillar-5( SFP-5/1,SFP5/2)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 400 A, 4 strip Al. Busbar complete with interconnection, bottom with MS chennel, Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
6 No. 63A 4P MCCB 25 kAwith adjustable thermal magnetic O/L & S/C release & handle.
4 No. 63A DP MCB 10 kA
5 No. 40A DP MCB 10 kA
MAIN BOARD FOR PUMP HOUSE (NORMAL CUM ESSENTIAL)
Supplying, installing, testing & commissioning of compartmentalised wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly phosphatized & powder coated inclusive of 400A 4 strip Al. Busbar complete with interconnection pdg. Lugs, inter-earthing, painting, providing and fixing following switchgears including connection, interconnection as required:
INCOMING :
OUTGOING :
2 Nos. 200A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
5 Nos. 63A 4P MCCB 25 kA with thermal magnetic O/L & S/C release & handle.
75HP Fully automatic Star/delta starter - 2Nos.
15HP Fully automatic Star/delta starter - 2Nos.
8 Nos. 40 A 4P MCB
3 Nos. upto 7.5 HP fully automatic DOL starter
3 Nos. upto 10 HP fully automatic Star/DELTA starter
5 Nos.25 A 4P MCB
4 Nos. upto 3 HP fully automatic DOL starter
Supply of hot dip galvanised Raceways of following sizes and fixing the same with accessories complete as per specification and as per the direction of Engineer-in-charge
SUB HEAD - 3 (EXTERNAL LIGHTING)
Supply, Installation, testing & commissioning of single arm10 M high Hot Dip Galvanized Octagonal Poles with a galvanizing thickness of minimum 65 microns (Internally & Externally), 200 mm dia at the bottom & 100 mm dia at top, 3 mm sheet thickness with base plates of 350 mmx350 mmx20 mm thikness, anchor bolts, foundation & 1.5 mtr long arms, the poles should have internal pole box with cover complete as per secifications as required.
Supply and erection of 90W LED street light with IP-66 degree of protection, complete in all respect.
Supply of 350W LED flood light suitable for Highmast Flood with intgreal control gear with potted drivers with IP 66 degree of protection,complete in all respect as required.
Supply Installation, Testing and Commissining of 30M high mast shaft in three sections suitable for 47 m/sec wind speed, with raising lowering system comprising, head frame, luminaries carriage with fixing of 12 nos. of 350 Watt LED flood light fixture, in symmetrical arrangement, double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial including foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.. Wiring material,power cables between panel and mast, upto light fixtures suitable rating MCB with high mast control panel including astronomical timer with contactors, CG mounting clamps and bolts, etc. including relay timer for auoamtic switching ON and OFF of luminaires at dusk and dawn. (luminary mounting bolts are not included) including Fabrication and supplying of winch driving power tool with motor , remote switch, manual handle for operating winch with torque limiter etc. complete as required.
Supply, Installation, Testing and Commissioning of twin dome aviation obstruction lights with two nos no. 100 W GLS lamps.
Supplying of following 1.1 KV grade aluminium conductor extruded XLPE insulated PVC innersheath,GI wire/tape armoured specified and outer PVC sheathed cable of following specifications and sizes as per IS 7098 (Part I) as required.
2X6 Sqmm
2x10 Sqmm
4x16 Sqmm
4x25 Sqmm
3.5 x35 sqmm
3.5 x50 sqmm
3.5 x70 sqmm
3.5 x95 sqmm
3.5 x120 sqmm
3.5 x185 sqmm
3.5 x240 sqmm
3.5 x300 sqmm
SUBHEAD - 4 ( HT / LT INDOOR SUBSTATION, LT PANELS AND CABLES )
Supplying, installation, testing & commissioning of two pole structure for receiving 11KV supply SEB meter with 11 KV, 3 pole, Gang operated switch along with drop out fuse and L A etc . Complete as required
11 KV H.T. PANEL : (VCB PANEL BOARD)
Design, Supply, Installation, testing and commissioning of a TTA type Three panel indoor duty totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked vertical isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having double isolation features complete with circuits as detailed below. The switchboard would be complete with necessary PVC insulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA.
All Incoming and outgoing feeders shall have fault trip auxiliary contacts for wiring to annunciation fault trip indication panel. 8 window Annunciation panel with necessary relays, audio and visual indicators and push buttons to be considered as per requirement.
11 KV HT Switchboard -Indoor duty-(IP-52)
1 no. Incomming and 2 nos. outgoing panel equipment with following items.
Incomer
1- Air insulated metal clad housing
1- set of 3 phase PVC insulated copper busbars 630 amps
6- Single pole cluster type isolating contacts; i.e. plug and switches
1- Triple pole EDO drawout truck mounted 11 kV 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices.
1- Trip free 230 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator.
6 NO/NC contacts for remote ON/OFF/TRIP status
1 - 24 volts DC shunt trip coil
3 - Dual Core Cast resin Current transformers of ratio 200/5Amp. Class 5P10 and Class 1.0, 15 VA burden for protection & metering
1- Strip heater with thermostat to prevent absorption of moisture
1- 3 Phase cast resin horizontal draw out line potential transformer ratio 11000/√3 :110/√3 volts, connected star/star with H.V. and L.V. connections, H.V. and L.V. fuses, isolating plugs for H.V. and L.V. connection.
1 no. energy analyser to measure voltage, current, power factor, frequency, kW/kVA, kWh, kVArh, kVAh, Real time,date with communication module.
1- Triple pole numerical I.D.M.T. over current, short circuit and earth fault relay, with two outer elements connected for over current and the middle element for earth fault protection, over current setting 50% - 200%, Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on over current and 200-800% on earth fault (51, 50, 51N & 50N)
1 - Electro mechanical Master trip relay (86)
1 - Electro mechanical Anti pumping relay (94)
1 - Trip Circuit supervision relay.
1- set Electro mechanical auxiliary relay for transformer fault ALARM for winding temperature conditions (63x)
1 - no. circuit breaker control switch for electrical (T/N/C)
1 - push button on front door for emergency trip
1- set of Red/Green indicating lamps for close and open position
1- Amber indicating lamp for auto trip
1- clear indicating lamp for trip circuit healthy
1- set of white indicating lamps one per phase
1 - blue indicating lamp for spring charged
1- cable termination suitable to receive 11 KV XLPE cable 3 core upto 300 sqmm.
The switchboard shall be complete with all interconnections, label wiring, etc as required and as per direction of Engineer Incharge.
Outgoing:- Each Outgoing feeder consist with the following
1- Air insulated metal clad housing
1- set of 3 phase PVC insulated copper busbars 630 amps
6- Single pole cluster type isolating contacts; i.e. plug and switches.
1- Triple pole EDO drawout truck mounted 11 kV 350 MVA, 630 amps Vacuum circuit breaker fitted with arc control devices.
1- Trip free 230 V AC, motor charged spring release closing mechanism complete with necessary auxiliary switches emergency hand trip device and mechanical 'OFF' and 'ON' indicator.
6 NO/NC contacts for remote ON/OFF/TRIP status
1 - 24 volts DC shunt trip coil
3 - Dual Core Cast resin Current transformers of ratio 100/5 Class 5P10 and Class 1.0, 15 VA burden for protection & metering
1- Strip heater with thermostat to prevent absorption of moisture.
The instrument and relay panel fitted with
1 no. energy analyser to measure voltage, current, power factor, frequency, kW/kVA, kWh, kVArh, kVAh, Real time, date with communication module.
1- Triple pole numerical I.D.M.T. over current and earth fault relay, with two outer elements connected for over current and the middle element for earth fault protection, over current setting 50% - 200%, Earth fault setting 20% -80% and with instantaneous element on all 3 pole settings 500-2000% on over current and 200-800% on earth fault (51, 50, 51N & 50N).
1 - Electro mechanical Master trip relay (86)
1 - Electro mechanical Anti pumping relay (94)
1 - Trip Circuit supervision relay.
1 - set of electro mechanical auxiliary relay for Transformer
1- set Electro mechanical auxiliary relay for transformer fault ALARM for winding temperature conditions (63x)
1 - no. circuit breaker control switch for electrical (T/N/C)
1- Amber indicating lamp for auto trip
1- clear indicating lamp for trip circuit healthy
1- set of white indicating lamps one per phase
1 - blue indicating lamp for spring charged
1- cable termination suitable receive 11 KV XLPE cable 3 core upto 300 sqmm. The cable entry must be from top and bottom as per site condition.
The switchboard shall be complete with all interconnections, label wiring, etc as required and as per direction of Engineer Incharge.
Supplying, Installation, testing and commissioning of the following for metering and protection.
Lead acid 24V storage battery of suitable ampere hour capacity suitable for 11 KV panels in HT panel room.
Float trick charger suitable for above items for 30 volts DC
DC distribution board suitable for above application including tripping, closing and indication etc.,
Control cabling between DC distribution panel to HT panel with cable size 4 core 2.5 sq. mm copper cable
control cabling between transformer and panel using armoured PVC insulated copper conductor of appropriate cores for indication and alarm etc.,as required.
Suitable Earthi switch for incomer and outgoing breaker
TRANSFORMER (Indoor Type)
Supplying, installation, testing and commissioning of Cast Rasin Dry type 1600 KVA, 11/0.433 KV,3 Phase, 50 Hz Dyn 11 vector group , copper wound, class F insulation associated with winding temperature indicator , controller actuated by means of resistance tempertature detector embedded in LV winding , Indoor type transformer with 5 % impedence tapping for off load operation on HV side , +5% to - 10 % having steps of 2.5 %, having cable end boxes on HV side suitable for 3 x 300 sqmm XLPE cable of 11 KV grade and 2500 amp bus trunking arrangement on LV side with neutral brought out separetly including supplying and laying of copper conductor multicore control cable from transformer to HT breaker for safety , tripping , suitably mounted on M.S canneli/c supplying and groutning of suitable M.S cannel with all accessories and confirming to IS 2026 / 11171 : 1985 with latest amendement and as per specification complete in all respects as required.
Supplying, installation, testing and commissioning of 1600kVA 9-12/11 KV HT, Oil Immersed, Naturally Cooled, On-Load, Stepless, Rolling Contact, Brentford Type Automatic Voltage Regulator as per technical specification complete in all respects
Supply of 3x300 sqmm, aluminium coductor, 11 KV (E) armoured cables in Aluminium conductor as per IS 7098 (part-2) 1985 latest, and complete as per specifications.
(DIESEL GENERATOR SET)
DG Set
Supply, Installing, Testing and Commissioning of ‘Silent Type’ 500 kVA Diesel Generating set complying to CPCB -4 Norm alongwith having Prime Power Rating of following sizes, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system complete with the followings:
(a) Integrated DG Set controller for auto start, auto sync. And auto load sharing, PLC panel. (b) Adopter box with extended alluminium bus bar
Diesel Engine:
Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories
Engine mounted Instrument Panel fitted with and having digital display for following:
Start- Stop switch with key
Water temperature indication
Lubrication oil pressure indication
Lubrication oil temperature indication
Battery charging indication
RPM indication
Over speed indication
Low lub. Oil trip indication
Engine Hours indication
Alternator :
Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation.
Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Fuel Tank:
Inbuilt fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
Exhaust System:
Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor
Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp. Hour capacity lead acid type) and Battery Charger as required as per specifications.
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications
Main LT (Normal cum Essential) Panel
Supply, Installation, testing & Commissioning of MAIN L.T. Panel/ switchboard as descibe below with Type-1 & Type-2 Surge protection device (SPD) as per NBC-2016 guidelines, panel shall be made as per the latest relevent Indian/ IEC Standrad. The manufacturer should possess valid type test certificate from CPRI for the current rating of Busbar equal to or more than the specified current rating.
compartmentalized, dust and vermin proof, IP 52 ingress protection, suitable for use at 433 volts, 3 phase 4 wire 50 Hz system & symmetrical fault level of 50kA at 433 volts, fabricated from CRCA sheets not less than 2 mm thickness for load bearing section and 1.6 mm thickness for non load bearing section with hinged doors, colour coded, heat shrinkable PVC insulated busbar, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3mm thick gland plates on top and bottom and including lifting hooks, including full length earth strip of required size with 2 nos earthing terminals, powder coated paint finish of RAL7035 shade over metal surface cleaned and treated with seven tank process complete with interconnections etc. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, feeder description/inscription plate earthing, numbering, danger plate etc. Complete in all respect with all lead and Lifts for making system functional as per the latest relevent Indian/IEC standard, technical specification and as per the directions of engineer incharge of work.
(I) Incoming :
2 nos INCOMER From TRANSFORMER
1 No. 2500A 4 pole microprocessor based EDO, horizontal draw out type air circuit breaker of fault breaking capacity 50KA(Ics=Icu )upto 433V ACB with, door interlocking, automatic safety shutter, mechanical ON/OFF and serive/test/isolated [oisition indicators and frame earthing contact and with integral protection, anti pumping protection microprocessor based O/C, S/C & E/F protection etc
1 set of 3nos. 2500/5A, 15 VA, class-1 CTs for APFC relay.
1 set of R,Y,B indicating lamps each with 3 nos. 2A SP MCBs.
One (1) No. multifunction meter (MFM) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH,KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).
One (1) set 3 Nos. CT's of ratio 2500/5A,15VA, Class 1.0 as required.
1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps with TNC control switch.
240 V AC Motor wound spring closing mechanism & manual spring closing mechanism
1 - 24 volts DC shunt trip coil & releases.
6 nos NO/NC contacts for remote opening & closing
Terminals to receive XLPE insulated Aluminium cables
Surge protection device Type-(1+2)
One (1) No. 6 Window Audi/visual annunciator system complete with hooter, Ack, test & reset PBs for annunciation of Alarm and Trip for following :-
Winding Temparature Indicator (WTI) Alarm, WTI Trip, LT Breaker Trip, HT Breaker Trip
Emergency push button and breaker control switch
1 No. Incomer from Synchronization Panel:
1 No. 2500A 4 pole microprocessor based EDO, horizontal draw out type air circuit breaker of fault breaking capacity 50KA(Ics=Icu )upto 433V ACB with, door interlocking, automatic safety shutter, mechanical ON/OFF and serive/test/isolated [oisition indicators and frame earthing contact and with integral protection, anti pumping protection microprocessor based O/C, S/C & E/F protection etc
1 set of R,Y,B indicating lamps each with 3 nos. 2A SP MCBs.
One (1) No. multifunction meter (MFM-2) with Rs-485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).
One (1) set 3 Nos. CT's of ratio 2500/5A,15VA, Class 1.0 as required.
Volt & Ammeter of battery/Battery charger system.
Load on DG Set and battery charger indication.
1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps with TNC control switch.
6 nos NO/NC contacts for remote opening & closing
Terminals to receive XLPE insulated Aluminium cables
Surge protection device Type-(1+2)
1 No. reverse power relay in each feeder
1 No. Incomer from Solar System
1 No. 400A 4 pole microprocessor based MCCB of fault breaking capacity 50KA(Ics=Icu )upto 433V with, door interlocking, microprocessor based release for O/C, S/C & E/F protection etc
1 set of R,Y,B indicating lamps each with 3 nos. 2A SP MCBs.
One (1) No. multifunction meter (MFM-2) with Rs-485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics.
One (1) set 3 Nos. CT's of ratio 400/5A,15VA, Class 1.0 as required.
Terminals to receive suitable for appropriate rating Busduct entry should be provided.
Surge protection device Type-(1+2)
1 No. reverse power relay in each feeder
BUS BARS- 1&2
Electrolytic high conductivity Aluminium three phase and neutral (100% neutral) busbars with earthing rated at 3000 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 KA at 415 volts.
BUS COUPLER: - 2 nos .
1 No. 2500A FP EDO ACB (without release) with all required accessories.
1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as required.
1. Outgoing : (i) 630A 4P 50KA MCCB - 4 Nos. (ii) 500A 4P 50KA MCCB -2 Nos. (iii) 400A 4P 50KA MCCB -5 Nos. (iv) 315A 4P 50KA MCCB -3 Nos (v) 250A 4P 50KA MCCB -2 Nos (v) 200A 4P 50KA MCCB -3 Nos. (vi) 160A 4P 50KA MCCB -5 Nos.
(V) Arc Fire Suppression System: (i) Arc Monitor (1 no.) (ii) Extension Unit (1 no.) (iii) HMI Kit (1 no.) (iv) Detector cable
Notes :-
Each ACB, MCCB outgoing feeder shall be provided with R,Y,B & on, off, trip indication lamps, and Multi function Meter with RS-485 port, with one set of suitable ratio & VA class 1.0 CTs, etc.
Necessary interlocking with PLC auto controls such that 2 Nos. T/F incomer, 1 No Bus coupler, 1 Nos incomer from Synch. Panel and 1 No. Incomer from Solar Power system
The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required.
Incomers for Transformer, D.G. sets, Solar system & Bus couplers shall be electrically & mechanically interlocked. Automatic and manual synchronization to be done, extra PLC to be consider for Synchronizing as required.
Sufficient No. of contacts terminals shall be provided in the panel as required for necessary remote operation and indications etc.
Operation interlocks with sufficient nos. of potential free contacts for interlocking/ indication annunciation/ control etc shall be provided by the bidder as required.
433/110V suitable rating control transformer and shall be provided for aux. control supply.
Wiring with space heater, thermostat, LED lights and control MCB's shall be provided for all vertical sections of main LT panel.
All incoming & outgoing as well as outgoing feeders shall have pad locking facility.
Suitable danger board shall be provided.
Synchronizing panel
Design , Manufacture , Supply , Installation, Testing and Commissioning of cubical type Synchronization PLC based Panel, suitable for 3x500 kVA kVA DG Set, fabricated from 14 SWG , CRCA sheet , floor mounting, dust & wermin proof, front operated construction, enclosure class - IP 54, powder coated after proper treatment with 7 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections wiring by minimum. 4 sq. mm. FRLS copper wires, ckt labels etc. 2500A TPN Al busbar (heat shrinkable sleaves) and schematic diagram as required. as per load demand the DG sets must be switch ON .
INCOMING: 500kVA DG SET: 03 Nos. 1000 Amp four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA ( Ics= Icu upto 415V Electrical operated , fitted with interlocked door , automatic safety shutters, mechanical ON/ OFF and service /test/isolated position indicators and frame earthing contact , conforming to IS 1397-2 :1993 as amended up-to-date complete with following accessories for each ACB incomer.
(A) Auto & manual spring closing mechanism -1 No.
(B) microprocessor release ( EMI & EMC certified ) for over current , earth fault & short circuit protection - 1 set
(E) 3Nos. phase indication LED lamps with 2Amp back up MCB, breaker `On` indicating light with 2A MCB , test terminal block set, circuits as per standard practice , auxilliary contacts for positive interlocking of the breakers as required .
(F) Shunt trip coil 24V DC.
(G) 1000/5A CT class PS 15VA
(H) 1000/5A CT class 5P10 15VA
(H) Multifunction metert with RS 485 class 1
Outgoing
1No. 2500 A 4Pole MDO ACB 50KA
Multi function meter with RS 485 for measuring of Voltage, Current, Power factor, etc.
One no. 12 window Audio/visual annunciator system complete with hooter, Ack, test & Reset PBs for annunciation of low lube oil pressure, Engine over speed, Electrical prot trip, Engine fail to start, low fuel level complete with power supply arrangements.
Each ACB, MCCB outgoing feeder shall be provided with R,Y,B & on, off, trip indication lamps, and Multi function Meter with RS-485 port, with one set of suitable ratio & VA class 1.0 CTs, etc.
Necessary interlocking with PLC auto controls such that 2 Nos. T/F incomer, 1 No Bus coupler, 1 Nos incomer from Synch. Panel DG Load management and load sharing shall be successfully operational in all possible combinations.
The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required.
Incomers for Transformer, D.G. sets, Solar system & Bus couplers shall be electrically & mechanically interlocked. Automatic and manual synchronization to be done, extra PLC to be consider for Synchronizing as required.
Sufficient No. of contacts terminals shall be provided in the panel as required for necessary remote operation and indications etc.
Operation interlocks with sufficient nos. of potential free contacts for interlocking/ indication annunciation/ control etc shall be provided by the bidder as required.
433/110V suitable rating control transformer and shall be provided for aux. control supply.
Wiring with space heater, thermostat, LED lights and control MCB's shall be provided for all vertical sections of main LT panel.
All Incomer & Buscoupler breakers shall be interlocked through Mini PLC with Auto load management and AMF operation control.
All incoming & outgoing as well as outgoing feeders shall have pad locking facility.
Suitable danger board shall be provided.
APFC Panel
Design, manufacture, supply, storing, inspection, handling, assembling, installation in correct alignment, position, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 400 KVAR APFC Panel APP/Mdxl type consisting of, 2 nos. 100 KVAR,2 nos. 50 KVAR, 3 nos. 25 KVAR,1 nos. 10 KVAR, 3 nos. 5 KVAR, complete with 1 no 12 step APFC relay etc., in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & virmin proof, front operated construction, enclosure class - IP 52, Painting by one coat of red oxide primer with two coats of approved synthetic enamel paint complete with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all capacitor duty contineous to be used for switching etc., as required. inter connections small wiring by min.2CX 2.5 sq. mm. copper cable, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 440 Volts, 3 phase 50 Hz, suitable.
SUBHEAD - 5(SAFETY EQUIPMENTS)
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg. capacity.
Supply and fixing of foam fire extinguishers, Portable type 9 litre capacity hanged on wall with bracket complete as required.
Supply and fixing safety instruction chart in word duly framed with 5 mm thick glass as required. (approx. front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on M.S. angle iron frame with bracket of appropriate size and capacity including filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 2217-1963.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required (approximate front area 1.20 sq.mt.)
Providing of rubber mat 1 mtr. wide and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969.
Providing of rubber mat 1 mtr. wide and 6 mm thick to withstand 3.3 KV dielectric strength as per IS 5424-1969.
Supplying 11KV grade rubber gloves as per IS.
SUBHEAD - 6 (ELV System)
SECTION I - STRUCTURED CABLING SYSTEM PASSIVE
Supply, installation, testing & commissioning of armoured 6 core Singlemode OS2 (9/125 Micro), Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as stregth member for switch connectivity. Cable should be ROHS compliant and as per IEC60749-1 with product warranty of 30 years.
Supply, installation, testing & commissioning of 6F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1-2003 Optical Fiber Connector Part 1: Type LC and should have 30 years of product warranty.
Supply, installation, testing & commissioning of 24F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1-2003 Optical Fiber Connector Part 1: Type LC and should have 30 years of product warranty.
Supply, installation, testing & commissioning of LC-LC singlemode OS2 (9/125) duplex, LSZH fiber patch cord for LIU to switch connectivity. Patch Cord should have aramid yarn as strenght member with 1000 time mating cycle.
Supply, installation, testing & commissioning of CAT 6A UTP LSZH Cable, 23 AWG solid copper conductors in accordance to TIA/EIA 568 C.2 (Category 6a) & ISO/IEC 11801 2nd ed(Class Ea), UL Approved, tested @500 Mhz, with HDPE insulation of individual conductor and over all Dia of 7.2 mm for Connectivity of Hub room to End Point.
Supply, installation, testing & commissioning of CAT 6A UTP Universal (both tool & toolless) information outlet (I/O) in accordance with ANSI TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901-2014, ROHS Compliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle and UL approved,for Data, Voice, & Wi-Fi at user end.
Supply, installation, testing & commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, Black with cable support bar, clear label marks and earthing plug for CAT6A cable termination at rack end.
Supply, installation, testing & commissioning of CAT 6A UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to jack panel connectivity.
Supply, installation, testing & commissioning of CAT 6A UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for rack side switch to end user connectivity.
Supply, installation, testing & commissioning of 1, 2 and 4 port face plate, British Style with Shutter, 2 Plate system clear finish with transparent labelling, ABS-UL94-V2, ROHS Compliant, in accorandce with standards like ANSI/TIA-568-C.2, ISO/IEC 11801:2002 AMMD.2:2010, YD/T 926.3-2009 & ISO/IEC 60603-7 white for I/O fixing at user side.
Supply, installation, testing & commissioning of 42 U floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.
Supply, installation, testing & commissioning of 15U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.
Supply, installation, testing & commissioning of 6U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.
Supply, Installation, Testing & Commissioning of Weather Proof Outdoor Enclosure suitable for LIU ,PDU & Switches.
Supply, Installation, Testing & Commissioning of 4 or 6 Meter G.I Pole with foundation complete as required.
SECTION - II- IP-PBX SYSTEM
Supply, installation, testing & commissioning of Pure IP at core server Based voice solution with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,253 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode.
Supply, installation, testing & commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE .
Supply, installation, testing & commissioning of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh.
SECTION - III- LOCAL AREA NETWORK ( LAN )
Supply, installation, testing & commissioning of Core Switch with switching capacity of 3.2Tbps, forwarding performance of 2Bpps with 48 x 1/10G/25G SFP28 ports plus 4x 40/100G QSFP28 ports from day 1, dual hot swappable internal power Supply, installation, testing & commissioning , 100k IPv4, 100K IPv6 routes and 48K IPv6 multicast routes, should support minimum 200k MAC addresses. Should support advance layer 3 (OSPF, BGP and MPLS), with 1 year support. Stack Module/40 Gig Optics and all other Cables should be included in Day 1.
Supply, Installation, Testing & Commissioning of of Access Switch 24 Port POE+ Access Switches with switching capacity of 128 Gbps, forwarding performance 95 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W and 4 x 10G SFP+ uplink ports, should have support for 9 switch Stacking with bandwidth of minimum 120 Gbps. Should support min 2GB internal DRAM, 2GB internal Flash memory, 32K MAC address, 4k Multicast Routes, Should have static Routing from day 1 and upgradable to support OSPF and VRRP with 1 year support.
Supply, installation, testing & commissioning of fiber Modules 1000BASE
Supply, installation, testing & commissioning of fiber Modules 10G BASE
Supply, installation, testing & commissioning of Appliance based customised ITAM for asset inventory management with ability to map physical locations and exact rack elevations for audit and support control. Appliance shall be Intel x86 based device with secure intranet server with Linux Based operating system and relational databases for long term storage. Appliance includes license for 100 units under control.
Supply, installation, testing & commissioning of Wireless Indoor Access Point Combined data rate support Dual 5GHz : 4.8Gbps , 802.11ax , 2.4 GHz / 5GHz: 4x4 : 4SS WiFi 6, data rate upto 2400 Mpbs, Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array + Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WxLAN policies . The solution should be artifical intelligence based self healing soltion. Bluetooth® LE and IoTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware. Omni-directional Bluetooth Antenna , superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support. Operating temp. 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports.
Supply, installation, testing & commissioning of UTM Firewall with 4 X 10G SFP+ Ports, 8 x 1G ports. The device should have 9Gbps of Firewall throughput and 1.5 Gbps of NGFW throughput. 4 Gbps IPS througput, 3 Gbps of IPSec VPN with 1500 VPN tunnels support. Should have min 16GB internal DRAM. Should have redundant power Supply, installation, testing & commissioning .
Section -IV- IP CCTV SYSTEM
Supply, installation, testing & commissioning of CAT 6 UTP cable 23 AWG LSZH as per ANSI/TIA 568 C.2 and ISO/ IEC 11801–2nd Edition, ROHS Compliant, solid copper conductors, tested @250 Mhz, with HDPE insulation of individual conductor and over all Dia of 5.8mm for Connectivity of Hub room to End Point.
Supply, installation, testing & commissioning of CAT 6 UTP Universal (both tool & toolless) information outlet (I/O) in accordance with ANSI TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901-2014, ROHS Compliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle and UL approved,for Camera at user end.
Supply, installation, testing & commissioning of loaded 24 port CAT 6 UTP, Transparent shutter jack panel, 1U height, UL-94V-0, Black with cable support bar, clear label marks and earthing plug for CAT6 cable termination at rack end.
Supply, installation, testing & commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to jack panel connectivity.
Supply, installation, testing & commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for rack side switch to end user connectivity.
Supply, installation, testing & commissioning of 1, 2 and 4 port face plate, British Style with Shutter, 2 Plate system clear finish with transparent labelling, ABS-UL94-V2, ROHS Compliant, in accorandce with standards like ANSI/TIA-568-C.2, ISO/IEC 11801:2002 AMMD.2:2010, YD/T 926.3-2009 & ISO/IEC 60603-7 white for I/O fixing at user side.
Supply, installation, testing & commissioning of 5 MP Dome camera , ONVIF profile S , G& T ,UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS ,2.7 mm to 13.5 mm motorized varifocal lens , Quad stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP ,Edge analytics : Customer Flow staistics, Cross COunt, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 45 meters , IP 66 ,IK10,POE.Audio -1 input/1 output.
Supply, installation, testing & commissioning of 5 MP Bullet camera , ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS ,2.7 mm to 13.5 mm motorized varifocal lens , Quad stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+/MJPEG .SD card support up to 256Gb, Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staisticsCross Count, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , IR Distance upto 45 meters , IP 66 , POE. Audio -1 input/1 output.
Supply, installation, testing and commissioning of 5 MP PTZ Camera , UL,CE,FCC Certified , ONVIF profile S,G & Q , Quad stream,4.3-141.9mm focal length , 33 X Optical Zoom , 12 X digital Zoom ,Frame rate : 20 fps ,Shutter Speed : 1/5 ~ 1/100,000s , Inbuilt IR , IR distance upto 200 mtr , 2D / 3D noise reduction ,120 dB WDR , 360 deg endess pan , tilt -10 to 90 deg , auto flip support ,255 presets ,Auto pan ,Edge analytics : Pedestrian Intrusion Detection, Line cross Detection, Heat Map,Cross Count,Stationaary Object Detection, Vehicle Detection, face Detection, , SD Card supportup to 128GB , white balance-Auto/manual/indoor ,Fixed Iris, Alarm : 1 IN , 1 Out , Audio - 1 IN/1 Out,RS485,ROI,1xBNC IP 66 weather proof , Power : 24V AC/ POE+ /DC12V.
Supply, installation of 80mm dia 8 mtr.high GI pole complete with foundation and civil works for installation of outdoor cameras.
Supply, installation, testing & commissioning of 128 channel NVR upgradable upto 256 channel, Live and recording resolution up to 12MP, Recording bandwidth Incoming 1024 Mbps and outgoing 800 Mbps, RAM 32 Gb*2, Support RAID 0/1/5/6/10, Support Face detection and Recognition with Face Capture/Register quantity 1000000/ 10000, 512 User list, display out 3 HDMI and 1 VGA port, HDD: 16 SATA HDD Slots, Each SATA support up to 18TB, NVR support Power Supply, installation, testing & commissioning redundancy, Operating temperature -10°C~+50°C.
Supply, installation, testing and commissioning of Joystick with 5' LCD Display.
Supply, installation, testing & commissioning of 8TB Surviellance Hard Disk.
Supply, installation, testing & commissioning of Full HD 55" LED Professional Display Panel.
Supply, installation, testing & commissioning of L2+ managed industrial PoE switch with 24*10/100/1000M RJ45 ports and 4*1/10G SFP+ fiber slot ports, Port 1-24 can support IEEE 802.3af/at PoE standard, switching capaticy of 598 Gbps, forwarding performance 95.23 Mpps, maximum PoE output power is 400W(at-600W), with 32K MAC address. Should have Static Routing , system logging, Telnet, SSH2.0, SNMP V1/V2C/V3, Network Time Protocol (NTP), FTP, TFTP, Xmodem.
Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE switch with 10*10/100/1000M RJ45 ports and 4*100/1000M uplink SFP slot ports, Port 1-8 can support IEEE802.3af/at PoE. Support DC dual power supply input and DIN rail mounting. Switching capaticy of 256 Gbps, forwarding performance 20.83 Mpps, having 8 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 120W(at-240W). , with 2*10/100/1000Base-T uplink RJ45 ports 4*100/1000Base-X uplink SFP slot ports., 8K MAC address. Should have Static Routing , system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), and IPv6 features from day 1.
Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE switch with 4*10/100/1000M RJ45 ports and 2*100/1000M SFP slot ports, Port 1-4 can support IEEE802.3af/at PoE. Switching capaticy of 128Gbps, forwarding Rate 8.93 Mpps, having 4 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 60W (at-120W) , with 2*100/1000Base-X uplink SFP slot ports., 8K MAC address. Should have Static Routing , system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), and IPv6 features from day 1.
Supply, installation, testing & commissioning of 24 port Fabric (SFP) switch with 20 Nos. of 20 100M/1G SFP Port , 4 Nos. of GbE RJ45/SFP Combo Port , 4 Nos. of 1G/10G SFP+ Port ,1 X Console , Switching bandwidth 128 Gbps , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server.
Supply, installation, testing & commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.
Section -V- FIRE DETECTION SYSTEM
Supply, installation, testing & commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device UL & FM Approved.
Supply, installation, testing & commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved.
Supply, installation, testing & commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supply, installation, testing & commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL & FM Approved.
Supply, installation, testing & commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power Supply, installation, testing & commissioning , automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition & FM approved.
Supply, installation, testing & commissioning of Network Repeater Panel with minimum 10" Color Touch Screen display with QWERTY Keypad, mapping minimum 2,00,000 points on network. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation UL & FM Approved.
Supply, installation, testing & commissioning of Addressable Fire Fighter's Telephone Jack with suitable supervised module for two way communication between Remote Fire Fighter & Fire Command Center. UL Listed.
Supply, installation, testing & commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center.
Supply, installation, testing & commissioning of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable.
Section-VI- PA SYSTEM
SPEAKERS
Supply, installation, testing & commissioning of 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W.
Ceiling Mounted Speakers
Supply, installation, testing & commissioning of 6W Wall mount with max SPL1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 6W/3W.
Wall Mounted Speakers
PA CONTROLLER
Supply, installation, testing & commissioning of 8 zone IP based, digital Voice Alarm controller expandable upto 128 zones. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The Voice alarm controller should also have the following functions: . 255 Priorities . Time schedule broadcasts . Its own PTT microphone . Capable of amplifier redundancy . 8 trigger inputs/outputs
DIGITAL AMPLIFIERS
Supply, installation, testing & commissioning of 1X500W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection.
500 Watts
PAGING STATION
Supply, installation, testing & commissioning ing and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable.
Section -VII- SECURITY SYSTEM
Supply, installation, testing & commissioning of automatic electromechanical boom barrier suitable road width 3-3 mtrs for intensive applications torque-450 mm, high speed with 3 second opening/closing time with MS Powder coated housing & aluminium boom with fork rest, IP 67 Protection etc. (for Gate -Entry/Exit).
Supply, installation, testing & commissioning of a set of Entry/Exit push buttons for manual open and closing of barriers etc. complete as required.(for Gate Entry/Exit).
Supply, installation, testing & commissioning of Photocell based safety device to avoid closing of the barrier when a Vehicle is crossing the barrier. ( Anti Fall Protection ).
Supply, installation, testing & commissioning of Loop detector for closing of the barrier when a Vehicle crosses the barrier.
Supply installation, testing and commissioning of automatic number Plate Reading System (ANPRS) tuned to the license plates i,e it should be able to automatically read and record a wide range of vehicle registration number plates alpha-numeric character, written in English. Also the frontal image view of the vehicle to be provided in the GUI to facilitate manual viewing of the license plate image.Lane Coverage Each camera system covers at least 1 lane having width of 3.5 meter or more. Detection Zone 3m to 10 m for ANPR data, IP66 rated,1-1/2.8” progressive scan RGB CMOS or better50 H with IR cut filter Colour: 0.15 Lux @ 30 IRE F1.3 ,1/66000 s to 2 s or better,H.264 in High and Base profile, MPEG4, MJPEG,Minimum 4 Streams in H.264, 2MP, 25 fps,Resolution Minimum 1920 x 1080,Certification for box camera UL, CE certified\. Lens : should be minimum 3M , IR corrected 1/ 2.8,internal memory of 64 MB SDRAM and 128 MB FLASHES.consumption should be less than 5W.System should provide vehicle count, class of vehicles (minimum 8 class when installed over the lane and 4 lasses when installed on the side for multilane.
Supply of X-Ray Baggage Inspection System. Increases throughput at security checkpoints Easy to operate· The system must provide automated explosives detection capabilities by determining both atomic number and density. Optional TIM upgrade for liquids detection · Integrates with iLane checkpoint designs .Tunnel Dimensions –620 mm (W) x 420 mm (H) (min) or more and have an Operational Weight of not more than 850kg.
Supply of HAND HELD METAL DETECTOR Pulse induction technology, transmitter / receiver with automatic instant retune and should be compliant to NIJ-0602.02 . Indoor and outdoor use, very long battery life, no battery replacement necessary, fully programmable through USB interface, fully programmable optical alarm signaling (continuous or proportional), fully programmable acoustical alarm signaling (continuous or proportional), alarm vibration.
Supply of DFMD ,The Metal Detector shall panel version, complete withdual-beam photocells transit counter, four multi zones display bars programmable as pacing lights and 60 localization zones with left and right indication, Met-Identity technology, Random Alarm capability, low voltage DC power, Chip-Card programming, One-Touch automatic self installation, Bluetooth and RS-232 communication, anti-tamper on/off switch with Test Kit (OTP Test Kit) .
Supply, installation, testing & commissioning ing and Laying of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable.
Supply, installation, testing & commissioning of CAT 6 UTP cable 23 AWG LSZH as per ANSI/TIA 568 C.2 and ISO/ IEC 11801–2nd Edition, ROHS Compliant, solid copper conductors, tested @250 Mhz, with HDPE insulation of individual conductor and over all Dia of 5.8mm for Connectivity of Hub room to End Point. as complete as required
Section -VIII-AUDIO VIDEO SYSTEM
Audio System
Supply, installation and testing & Commissioning of Chairman unit with Wired Table Top unit with built in speaker and Rj45 Loop in and out, Internal high-fidelity loudspeaker, 48K audio sampling rate and 20Hz~20KHz frequency response, Support AGC/AFC/ANC,Signal to Noise Ratio:70 dB, Frequency response:20 ~ 20000Hz,Cardioid, Sensitivity--46dBV/Pa,Length-485mm OLED Display, MIC ON/OFF,priority button and consent button Chairman unit has priority to close all other units or mute them temporarily and consent the request for speaking from delegate, Should have 3.5mm Stereo Headphone Jack.
Supply, installation and testing & Commissioning of Wired Table Top Delegate unit with built in speaker and Rj45 Loop in and out, Internal high-fidelity loudspeaker,48K audio sampling rate and 20Hz~20KHz frequency response,Support AGC/AFC/ANC, OLED Display, MIC ON/OFF,Volume up and down,Input impedance:2 kΩ, Signal to Noise Ratio:70 dB,Frequency response:20 ~ 20000Hz, Cardioid,Sensitivity--46dBV/Pa,Length-485mm,Should have 3.5mm Stereo Headphone Jack.
Supply, installation and testing & Commissioning of Conference control unique digital ring network technology achieve full-digital signal transmission and processing,48K audio sampling rate,Output 16 segment equalized EQ to achieve sound field adjustment, AGC automatic volume gain control,AFC automatic feedback suppression and auto-mix technology,advanced noise cancellation technology,Echo cancellation,USB audio recording, Audio Input:2 channel audio input, XLR or RCA type, for local audio input or remote video-conferencing input.Front panel USB recording interface, 3.5mm headphone for monitoring Audio Output:Maximum 8-channel audio output, XLR, RCA and Phoenix type, Control Port:RS232 central control, realize microphone switch, priority, volume and other control,Camera Control:RS232 or RS485 to send the PELCO/VISCA protocol to realize camera auto-tracking function. Control & Indicators:LCD display to show all the operations and results 4-Way button for menu operate,One-button press to start recording light indicator,Master volume control knob etc.
Supply, installation and testing & Commissioning of 2-way, Ceiling-mount loudspeaker with 2 ways, Passive, low impedance power 30W@8 Ohms, Power 100V 3.8W/7.5W/15W/30W, Power 70V 1.9W/3.8W/7.5W/15W/30W, LF transducer 6.5" woofer, HF transducer 0.5" tweeter, Freq Range 90Hz - 20KHz, Coverage 155° x 155° @ 1KHz; 75° x 75° @ 4KHz,Sensitivity 88dB, Max SPL 102dB, Mounting Diameter 200mm, Fixation rotary anchors, Material Enclosure: Metal; Grille: ABS plastic.
Supply, installation and testing & Commissioning of Column Array Loudspeaker with Passive transducers 8x Woofers 2.75" Diameter, Rated Impedance 8 ohms, minimum impedance 8.6 Ohms @ 595Hz, Power 100Wrms, Sensitivity 93dB SPL, Max SPL 119dB SPL, Freq range 150Hz to 23Khz (-10dB), 170Hz to 20kHz (-6dB), Recommended HPF filter Butterworth 24dB/Oct, 100Hz, Coverage 140° x 20°, IP protection IP65.
Supply, installation and testing & Commissioning of 2 channel Class D Amplifier with 300W @ 8 Ohm 2-channel, Freq Range 20 Hz - 20 KHz, THD+N <0.15 %, S/N Rate >100 dB, Damping Factor >500, Gain 36 dB, Input Sensitvity 0.775 V / 1 V / 32 dB, Protections Soft start, VHF, DC, Overload, Clip, Limiting, Short-circuit, Over-temperature, Progressive volume.
Supply, Installation, Testing & Commissioning of 12 x 8 Networked Digital Signal Processor ,DSP with 12 inputs and 8 outputs, 12 Control Inputs and 6 Logic Outputs for GPIO Integration, 48V phantom power on all analog inputs, THD: <0.01% 20Hz to 20KHz, +10dBu output, should have AEC input for Microphone. Crosstalk: <-75dB, Open architecture software configurable, Separate logic processing power, 2 digital audio bus RJ 45 Port ,1 Ethernet port for Monitoring and configuration ,Capable to handle +5V unloaded logic output voltage , at-least 6,Should have speech sense engine ,Should have USB port inbuilt/External for soft VC integration.Capable to control 3rd party devices with TCP IP and RS 232 ,Should have 1nos of RS 232 port for integration with control System,Should have Bi-Directional Locate Functionality, Should have 48 or more digital audio Channel Bus, Should have monitoring LED for COM, STAT, ERR and PWR.
Video System
Supply, Installation, Testing & comissioning of 86"Professional Display with UHD Resolution (3840 x 2160), Panel :VA/IPS,Brightness:Better: 330 Nits,Response Time:5ms,Display Colors:1.07 Billion,Audio: Built in Speaker,INPUT Type:HDMI 2.0 X 2,USB 2.0 x 2 , RS232 x 1, RJ45 x1, OUTPUT Type:Audio Out, RS232,Speacial features:Temperature Sensor,Pivot Display, Wireless Mirrioring, 8GB internal memory,EXTERNAL CONTROL:RS232C(in) thru stereo jack, RJ45, IR,Power Consumpstion:200W.
Supply installation Testing & comissioning of Wall mount for 86" Display.
Supply, Installation, Testing & comissioning of 55"Professional Display withUHD Resolution (3840 x 2160), Panel :VA/IPS,Brightness:Better: 400 Nits,Response Time:5msto 8 ms,Display Colors:1.07 Billion,Audio: Built in Speaker,INPUT Type:HDMI 2.0 X 2,USB 2.0 x 2 , RS232 x 1, RJ45 x1, OUTPUT Type:Audio Out, RS232, Speacial features:Temperature Sensor,Pivot Display, Wireless Mirrioring, 8GB internal memory,EXTERNAL CONTROL:RS232C(in) thru stereo jack, RJ45, IR,Power Consumpstion: Less than 150W.
Supply installation Testing & comissioning of Wall mount for 65" Display.
Supply installation Testing & comissioning of 14" or better table monitor for chairman.
Supply, Installation, Testing & Commissioning of Video Conference System with support H.323 & SIP standards for communications, Support interoperability and bandwidth saving using video compression H.264 AVC, H.264 High Profile, H.265,Support 1080p30 fps,720p 30 fps, support both wired content sharing using standard based H.239 .It should also support audio from PC used for content sharing. support G.711, G.728, G.729A, G.722, G.722.1, G.719 or betterAutomatic Gain Control and Automatic Noise SuppressionAspect ratio: 16 x 9 or better, Video Conference with covers a wide field of view of 70˚ or better, with the mechanical pan, tilt, and12x zoom or better that can be controlled using a simple handheld remote or touchpanel.HD 1080p video at 30 frame per second.
Supply, Installation, Testing & Commissioning of Cable Cubby with 2 X powwr socket and 4 or more passthrough holes for HDMi and LAN connectivity.
SITC of Transmitter-HDBaseT Connectivity – extends an HDMI connection over a long distance via one Cat 5e/6/6a cable;POH (Power over HDBaseT) – supplies power from Transmitter to Receiver over a long distance via one Cat 5e/6/6a cable;Bi-directional RS-232 channel – allows you to connect to serial terminals or serial devices, such as touch screens and barcode scanners;Bi-directional IR channel – IR transmission is processed one direction at a time;Up to 4K@35m (Cat 5e/6) / 40m (Cat 6a),1080p@60m (Cat 5e/6) / 70m (Cat 6a);4096 x 2160 / 3840 x 2160 @ 60Hz (4:2:0);4096 x 2160 / 3840 x 2160 @ 30Hz (4:4:4);Max. Data Rate:10.2Gbps (3.4Gbps per lane);Max. Pixel Clock:340 MHz;HDMI (3D, Deep Color, 4K),HDCP2.2 Compatible,Supports CEC.
Supply, installation and testing & Commissioning of Wireless Presentation For Meeting Space Collaboration, Should support one-click Skype for Business and Zoom meeting launch, Share content wirelessly from a mobile device or PC using Airplay or Google Cast, View documents from the web, cloud storage, network drive, or a USB thumb drive. Built-in document viewers allow for side-by-side view of two documents, and 4K support for dual monitors provides an optimal collaboration experience, CONNECTORS : 4x USB 3.0 , 2x USB 2.0 , 2x HDMI , Ethernet 2x RJ-45 connector for gigabit Ethernet, Analog Stereo Input 1/8” mini-stereo jack and Analog Stereo Output 1/8” mini-stereo jack, HDMI Resolution Up to 4K30, WIRELESS :WiFi 802.11 a/b/g/n/ac, SUPPORTED CALENDAR SYSTEMS :Supported Calendar Systems Microsoft Exchange 2013 SP1 or higher, Microsoft Exchange 2016 and Exchange Online (Office 365), Included Applications: Viewers for Microsoft PowerPoint, Word, Excel and Adobe PDF documents, Viewers for images and videos and Microsoft Edge web browser Collaboration System.
Control System
Supply, installation and testing & Commissioning of Control Processor with Two RS-232/422/485 COM ports, Four RS-232 COM ports or better, Four IR/serial, 4 relay, and Four Versiport I/O ports, LAN Connectivity. Programmable event scheduling, Enterprise-class control system Support SD and SDHC Card upto32 GB & 8 GB Flash memory, SNMP remote management support. iPhone, iPad, and Android control app support. Power Input: 100 – 240 VAC, 50 – 60 Hz Output: 2.5 A @ 24 VDC.
Supply , Installation, testing & comissioning of 10 inch touch panel with Stand & provision for Charging.
Supply, Installation, Testing & Commissioning of 24 port Gigabit POE ( POE + at least one port ) Network Switch with Multicast support with IGMP V1/V2, QoS support, IPV4/IPV6 Support, Advance Security Management, Switching Capacity in Gigabits per Second, 1 Gbps Non-blocking ports with standard accessories.
Supply, installation and testing & Commissioning of dual band Wireless Gigabit Router.
Cable & Connectors
Supply, Installation, Testing & Commissioning of 2 core Speaker Cable.
Supply, Installation, Testing & Commissioning of 22-24 AWG two core sheilded Microphone / Control Cable.
Supply, Installation, Testing & Commissioning of sheilded cat6 cable.
Supply, Installation, Testing & Commissioning of 1.8m HDMI cable.
Supply, Installation, Testing & Commissioning of 10m HDMI cable.
Supply, Installation, Testing & Commissioning of 15m HDMI cable.
Supply installation & comissioning of 24U Equipment Rack with PDU & two tray & floor wheels .
Supply installation & comissioning of cable & connectors.
SUB HEAD- 7 (EQUIPEMENTS)
WEIGH BRIDGE
Supply, installation, testing & commissioning of Weigh bridge 120 T capacity including control panel, cabling & Remote display complete in all respect (Pitless Type) complete in all respect as per technical specification..
SUB HEAD- 8 (VRV SYSTEMS)
Outdoor Unit
Supply, Installation, testing & commissioning of Variable refrigerant flow modular type air-conditioning system suitable to operate from 415+10% volt, 50 Hz,3 phase AC power supply for Cooling & Heating by using inverter driven capacity control compressors complete with individual controller and fittings with necessary wiring, connection & termination, painted MS frame for outdoor unit etc. as per quantity given below including full charging of R-410A refrigerant gas complete as per specifications.
The outdoor unit shall be factory assembled, weather proof casing (Material of construction of casing shall be vendor’s standard design), constructed from heavy gauge GI sheets steel panels and coated with enamel finish. The outdoor unit shall be completely factory wired, tested with all necessary controls & filled with first charge of refrigerant before delivering at site.
The inverter technology based D.C Twin Rotary / Scroll compressor modular type VRF equipment should of designed, so that refrigerant piping between outdoor units and furthest indoor unit shall be extendable up to 220m. Allowable level difference between outdoor & indoor unit shall be 40m. Allowable level difference between two indoor units connected to same outdoor unit shall be upto 15m. All the outdoor units comprising of multiple modules should have 100% inverter type compressor in each module.
The units should comply with minimum COP of 3.7 at 100% load and minimum 6.7 at 50% load in cooling mode at following conditions: Outdoor Condition 35 Deg C DBT and Indoor condition: 27 deg C DBT and 19 Deg C WBT, and each module should have all inverter compressor/unit. IEER not less than 6.3
The outdoor units shall be suitable to operate within an ambient temperature range of -5 Deg C to 53 Deg C in cooling mode and -25 Deg C to 24 Deg C in heating mode. Anti Ice Circuit/ Auto defrost kit if required to operate at this temperature in winter to be provided in ODU.
It should also be provided with duty cycling for D.C inverter Twin Rotary/ Scroll compressors capable of changing the rotating speed of compressor by inverter controller to follow variation in cooling & heating loads & switching starting sequence for better stability and prolonging equipment life or similar features if available in D.C Twin Rotary / Scroll will also be accepted.
The unit shall be provided with its own microprocessor control panel with provision for integration with the building management system for Air-conditioning system.
The machine must have a sub cool feature to use coil surface more effectively through proper circuit/ bridge so that it prevents the flushing of refrigerant from long piping due to this effect thereby achieving energy savings.
The outdoor unit should be fitted with low noise level and should not be more than 69 db (A) at normal operation when measured at a point 1 mtr. In front of the unit at a height of 1.5 mtrs.The outdoor unit should be fitted with low noise aero spiral design fan with aero fitting grill for spiral discharge airflow to reduce pressure loss and should be fixed with DC/AC fan motor for better efficiency.
The outdoor unit shall have refrigerant cool PCB chamber for better operation at high ambient temperature.
The outdoor unit shall have feature to change the evaporative temperature with respect to load for better comfort and energy efficiency.
The compressor is inverter based D.C Twin Rotary / Scroll compressor system shall be highly efficient. The system should response efficiently in accordance to the variation in cooling or heating load requirement. All outdoor units shall have multiple steps of capacity control to meet load fluctuation and indoor unit individual control. All parts of compressor shall be sufficiently lubricated stock. Forced lubrication may also be employed. Oil heaters shall be provided in the compressor casing.
Unit shall be equipped with an oil recovery system to ensure stable operation with long refrigeration piping lengths. The system shall have oil recovery cycle of 8 or more hours. The system must be provided with oil balancing circuit to avoid poor lubrication.
40 HP Heat Pump type Outdoor Units
Note: COP of the ODU units should not be less than 4.1 in cooling mode at ARI Conditions.
CEILING SUSPENDED DX BASED AIR HANDLING UNITS
Supply, Installation, Testing and commissioning of factory built CEILING SUSPENDED DX based double skin horizontal type air handling units made of 25mm thick panels consisting of prepainted G.I. casing of thickness 0.8mm outside layer and 0.8mm inside layer with polyurethane foam (PUF) insulationof density 38 kg/m3 factory injected between them by injection moulding machine, complete with DIDW backward curve SA blower section with blower suitable for external static pressure of 40 mmWG required, DX multirows deep interwind cooling coil section with aluminium finned copper tubes , filter section with 50 mm thick metal viscous/ washable synthetic type air pre filters, belt drive package with TEFC drive motor (IE-3) totally enclosed fan-cooled class F, with IP-55 protection suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply compatible for VFD operation, drain connections, stainless steel (18G) drain pan with PUF insulation, necessary vibration isolation arrangement, complete as required and as per specifications, drawings and of following capacities.
DX coils shall have 9.5 to 12.5mm dia (O.D) tubes minimum 0.4mm thick with sine wave aluminums fins firmly bonded to copper tubes assembled in zinc coated steel frame. Face and surface areas shall be such as to ensure rated capacity from each unit and such that the air velocity across the coil shall not exceed 500FPM. The coil shall be pitched in the unit casing for proper drainage. Single Condensate Drain Pan shall be large enough to accommodate all the split coils along with headers & valve assembly. Tube shall be mechanically expanded for minimum thermal contact resistance with fins. Fin spacing shall be 4 - 5 fins per cm.
12000 CFM/30 TR
Required AHU communication Kits complete including DX-Type electronic expansion valve and all arrangement including valves, control wiring, thermostat, temp. sensor including discharge air temp sensor etc. accessories to be provided.
AHU KIT & Controller
CENTRALIZED CONTROLLER
Supplying, fixing, testing and commissioning of Intelligent central control PC based monitoring consisiting of PC, controller, software for automation (ON/OFF, scheduling, lock/unlock, temperature setting, error detection) of entire system, all indoor units add monitoring of corresponding outdoor units from one central location. Controller should be BMS (like Bacnet, Lan works, Modbus) compatible. It must show the status of all indoor units along with outdoor unit. . All required accessories (hardware and software) to be provided for BMS connection. Controller should capable to provide all detail like Fail safe logic. ON/OFF sequencing.
Complete PC based Controller with all accessories without PC
Refrigerant Piping for VRF system
Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick ( pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) with XPLE Class-O tubular/ closed cell electrometric nitrile rubber tubular insulation sleeves sections of specified thickness between each set of indoor & outdoor units with outer mechanical protection of aluminum cladding for all exposed pipes as per specification. All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in M.S. painted cable tray etc. as reqd.
Piping vaccumiazation and Nitrogen testing to be done by contractor and price for the same to be included
Thickness of pipes should be as per VRF manufacturer's recommendation.
28.6 mm dia with 19mm thick insulation
25.4 mm dia with 19mm thick insulation
22.2 mm dia with 19mm thick insulation
19.1 mm dia with 13mm thick insulation
15.9 mm dia with 13mm thick insulation
12.7 mm dia with 13mm thick insulation
9.5 mm dia with 13mm thick insulation
Supply, Installation, testing and commissioning of necessary fittings, Y-joints and headers etc.
Supply, Installation, testing and commissioning Corded remote controllers for AHUs
Drain Piping for DX Based AHU
Providing & fixing of heavy duty uPVC Pipe complete with fittings, supports as per specifications and duly insulated with 6 mm thickness of XPLE Class-O tubular/ closed cell tubular nitrile rubber as required & as per specifications.
65 mm dia with 13 mm thick insulation
50 mm dia with 13 mm thick insulation
Providing and fixing of control cable of 2 Core x 1.5 sqmm. shielded cable in Heavy duty PVC conduit (20mm dia.) complete in all respect & as required.
Supply & Installation of suitable size of GI Ladder Tray for Copper Pipe & Condenser Power Cables ,
GI Sheet Metal Duct :
Supply, Fabricating, installing and testing of Site fabricated (Manual) sheet metal
24 gauge galvanised sheet
22 gauge galvanised sheet
Supply , Installation & testing of GI volume control damper (Box type) within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per approved shop drawings.
Supply, installation, testing and balancing of aluminium powder coated supply/return air grills of various sizes. Each grill shall be with fixed horizontal front bar at Zero/15 Deg deflection through the collar and register. Supply air grills shall be provided with removable key-operated aluminium volume control dampers.
Grills with VCD.
Grill without VCD.
Supply, installation, testing and balancing of aluminium powder coated supply/return air Diffuser of various sizes. As approved by the Architect. Supply air Diffuser shall be provided with removable key-operated volume control dampers.
Diffuser with VCD.
Canvass Connection
Supply, Installation,testing of fire retardant flexible canvass connection.
Thermal Insulation:
Supply, Installation and testing of external thermal insulation of Elastomeric Nitrile Rubber Class 'O' fire rated Insulation on ducts surface complete as per specifications.
9 mm thick insulation Supply Duct
Acoustic Lining of Ducts
Supplying, installing & testing of acoustic lining withfibre glasswool covered with tissue paper and 26 G Al. perforated sheet.
INLINE FAN
Supply, Installation, testing & commissioning of Inline fans suitable for installing in any position in horizontal or vertical ducts. The casing shall be constructed of galvanised steel. The motor shall be suitable for 220 +- 10% volt single phase 50 cycle AC supply.
500 CFM, static pressure 15 mm
100 - 150 CFM, static pressure 15 mm
Charging of Extra refrigerant at site
Loading & Unloading of equipment at site
Smart comprehensive Air Purification Solution
CAC (Central Air Cleaner)
Air purification for ceiling suspended Ductable indoor units and AHU The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. based on below principle technology viz;Impingement, Polarisation and Agglomeration as a passive air It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units, to centrally capture. It should be equivalent to Merv-14 or Higher efficiency for AHU and Ductable* Units with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. The Basic Media of Electric Filter shall Carry Class 2 Fire Rating Listing by UL.The CAC filter/Electrostatic percipitator (ESP), which have Metal based collection plate shall not be accepted. The Supplier shall carry UL2998 certification or at least Acknowledgement letter from UL2998 for testing against Zero Ozone Emission. The system shall be integrated with the existing pre-section filter area of AHU. The test report for pressure drop need to be submitted for passive air purification and the same shall be demonstrated at site.
Electronic filters should consist of an Internet of Things (IoT) based Smart Filtration option employing a 3-Tier Architecture. This architecture would serve to identify pressure drops across the filter, indicating when a replacement is necessary due to clogged filters. Furthermore, it should gauge levels of filter blockage, enabling scheduled preventive maintenance to ensure sustainability. To facilitate user interaction, a well-designed UI/UX experience in the form of a dashboard is essential, complete with appropriate color-coding. Additionally, the system should generate alerts and notifications via text messages or emails to signal instances of filter clogging or the need for filter replacement. To enhance compatibility, the system must support various communication protocols, including options such as WiFi.
*Subject to Available Static as per OEM Technical Data Sheet.
12000 CFM/30 TR
Air Purification System (Plasma Ionization)
The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU's, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.
Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory
The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application.
Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac.
Following Certifications are mandatory to produce
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 and UL 1995 certified.
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE.
The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices.
Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB.
Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas & Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab
12000 CFM/30 TR
SUB HEAD- 9 (Gas Suppression system)
2kg capacity FK-5-1-12 with UL approved non ferrous Seamless Cylinder, DLP Assembly with automatic valve, push in connector for tube, UL approved 2 Kilogram FK-5-1-12 Gas ref NFPA 2001 FK-5-1-12 , mounting bracket, End of Line adopter & Pressure guage ,UL approved low pressure switch for monitoring system activation.
4kg capacity FK-5-1-12 with UL approved non ferrous Seamless Cylinder, DLP Assembly with automatic valve, push in connector for tube, UL approved 4 Kilogram FK-5-1-12 Gas ref NFPA 2001 FK-5-1-12 , mounting bracket, End of Line adopter & Pressure guage ,UL approved low pressure switch for monitoring system activation.
Linear pneumatic heat Detection Tube :- UL Listed Heat detection Tube, 4mm ID, 6mm OD, detection temprature less than 175 Deg celcius, mutlilayer, Water Absorbtion ≤ 1.5% @ 20oC and 50% RH as tested per ISO62 with fittings and supports.
Master Control Unit for controlling each system, complete with pressure switches, buzzers and electronic hooters, including all necessary accessories + electrical wiring to make each entire system functional.
Installation & Commissioning
Supply, Installation, Testing and Commissioning of microprocessor based UPS system of 15 kVA rating at 0.9 pf true online UPS using PWM IGBT technology. 3-phase input 415V and input frequency 50 Hz, 3-phase out put fixed setting at 380, 415 and 430V with 30 min. battery backup as specified in technical specification, complete in all respects as required and as specified as per technical specification.
Description of Work / Item(s)
Amount
Interior and furnishing works
SECTION I - ROLLER BLIND
ROLLER BLINDS
Providing & fixing roller blinds, with head rail and fabric connector with min gap of 6/8 mm if required. Fabric 100% glass fibre with PVC coating on both side light transmission 5% with flame retardant.the control unit consists of clutch mechanism.The unit is made of high strength reinforced plastic.The clutch is of Wrap design. High carbon steel springs are provided to transmit motion from the driven mechanism. Clutch is operated directionally by use of endless beached chain to raise and lower the blinds smoothly to decide height.clutch never needs adujustment.Hand rail- to be provided of an aluminium-extruded rail on which the control unit and idler are mounted with help of bracket. Idler is high strength reinforced plastic consisting of an outside sleeve and center shaft. sleeve provide bearing surface for center shaft and rotate freely for longer wearing operation. Bracket are powder coated in white.operating chain is made of 4.5 mm plastic beads molded on 2.2 mm thick polyster cord. the pitch of the beads is 6mm fixing bracket are L-Bracket (2mm) and Clamp (0.5mm in zinc plated).
Roller tube is made up of high strength aluminium alloy extruded grooved tube which is powder coated or anodized.The fabric of the blind is attached to the tube. incase of light duty, the fabric is attached to plastic insert and incase of heavy duty, the fabric is attached using both side tape. Load bar is fixed to the bottom of the fabric and the purpose of it is to keep the fabric in tension and straight ,it is made up of extruded aluminium alloy with a groove for fixing the fabric using plastic. the ends are pluged using ABS ends caps.Complete in all respect.
BLACK OUT BLINDS
Providing & fixing roller blinds, with head rail and fabric connector with min gap of 6/8 mm if required. Fabric 100% glass fibre with PVC coating on both side light transmission 0% with flame retardant.the control unit consists of clutch mechanism.The unit is made of high strength reinforced plastic.The clutch is of Wrap design. High carbon steel springs are provided to transmit motion from the driven mechanism.Clutch is operated directionally by use of endless beached chain to raise and lower the blinds smoothly to decide height.clutch never needs adujustment.Hand rail- to be provided of an aluminium-extruded rail on which the control unit and idler are mounted with help of bracket. Idler is high strength reinforced plastic consisting of an outside sleeve and center shaft. sleeve provide bearing surface for center shaft and rotate freely for longer wearing operation. Bracket are powder coated in white.operating chain is made of 4.5 mm plastic beads molded on 2.2 mm thick polyster cord. the pitch of the beads is 6mm.fixing bracket are L-Bracket(2mm) and Clamp(0.5mm in zinc plated).
Roller tube is made up of high strength aluminium alloy extruded grooved tube which is powder coated or anodized.The fabric of the blind is attached to the tube. incase of light duty, the fabric is attached to plastic insert and incase of heavy duty, the fabric is attached using both side tape. Load bar is fixed to the bottom of the fabric and the purpose of it is to keep the fabric in tension and straight ,it is made up of extruded aluminium alloy with a groove for fixing the fabric using plastic. the ends are pluged using ABS ends caps.Complete in all respect.
FULL HEIGHT MODULAR PARTITIONS (Approx QTY)- Partition thickness is 60-75mm for added stability and with the inside gap between two tile is approximately 40-50mm for higher wire carrying capacity.The height of partition considered is 3000mm (approx.)The inside frame is made out of 1 to 1.2mm thick CRCA/Aluminium sheets .All the Frames are duly powder coated in black color to a thickness of 40-50 microns. The horizontals and verticals of the frames are fixed together at different heights so as to facilitate the wire management system running within the frame.All the frames are joined together by means of screws and nuts. They can be attached to form a 2-way, 3-way or a 4-way configuration. Possibility to join the frames at 90 degrees can also be provided within the system.All frames are covered with extruded aluminum trims. These trims are finished in an epoxy powder coating finish.The connectors at the top of the frames are made out of Die-cast Aluminum/CRCA/PVC. These caps also are finished in an epoxy powder coating finish in the same color. All the frames are fitted with leveling bolts. Wall Start- This is a joinery, which is used to fix partition with wall as per requirement, made of aluminium extrusion/CRCA steel. This should have necessary slots for fixing and can take wire from wall to partition.
Frames shall form the basic support structure for all components and shall be made CRCA/Aluminium sections . The main vertical member of the frame bearing the load of brackets and storages shall be made of 1mm thick CRCA steel/aluminium extrusion. The connecting vertical face shall be made up of 0.8mm thick CRCA Steel. The horizontal members shall be made of 0.8mm CRCA steel.
Raceways:-The raceways are made out of 0.6mm thick CRCA & powder coated. The raceway can be provided below worktop or above worktop. The skirting raceway is hollow and through out.
Tiles Laminate Tile: Constructed out of 6 to 8mm thick Medium Density Fiber Board (MDF)/PLPB. Glass Tile: 4mm glass fixed within an aluminium powder coated frame. Two such (double skin) tiles on either side of the frame complete the assembly.
Wire Management The partition has integrated raceway provided either at skirting level or the at the work surface level . The free space available within raceway accommodates power, data and communication cables. The cable can be taken into the Frame from the floor through the frame bottom. Once the cables enter the Frames , it can be taken from one end to the other end continuously as per Power / LAN layout plan. Approximately 60-70 (5mm Dia) cables can be accommodated in the raceway channels. The raceways are provided with CRCA Snap cover on both side of raceways where required or on one side depending upon where worktop is being used. . The cable running at skirting level can be terminated at tabletop level through disciplined wiring channels inside the frames . The raceway covers will be provided with appropriate electrical switch cutouts, as per the samples of switches provided , The number of cutouts in each workstation would depend upon the size of the switches.
Door panel :- 32-40mm Thickness with/without vision panel made out of Prelaminated Particle Board/MDF , along with all necessary hardware , complete as per manufacturers specifications and as per approval of Engineer-in-Charge.
Front Partition shall have Glass finish in all Modules.
Dividing Partition shall have Laminated Finish in all Modules.
DESIGNER FILM: Supplying and placing of approved make frosted film over the glazing as per the design having caliper face of 2.5 Mil, Min application temp 40 F , tensile at yield 4.0-8.0 lb/in, , eleongation 100 % Min, flammability - self extinguishing , service temp :- -50 degree to 180 degree Fahrenheit , resistance to most mild acids , alkalis , and salt solutions complete as per specification and approval of Engineer-in-Charge.
WALL PANELLING
Supply and Installation of Perforated Channelled wall panels of high density fiber board substrate with class 1 fire classification and with 0.5 min thick Laminate /Veneer finish and of size 2440X192X16 mm giving acoustic NRC of 0.7-0.9 and of class 1 fire rating . complete with all alumni channels accessories, border/corner profiles etc. (approved make G13/G21 wall panel of Armstrong or equivalent)
CARPET FLOORING
Providing and laying 100% solution dyed PP multilevel loop carpet of size 50mm X 50mm /25mm x100m. The gauge of the carpet should be minimum 1/12 inch with minimum stiches per inch is 9.5-10. The pile height should vary between 2.5mm – 5.5 mm and the minimum pile weight should be 600 g/m2 with a backing of E-bac. The carpet should pass Flammability as per ASTM E648 and smoke density as per ASTM E662, completed as per specification and approval of Engineer-in-Charge.
SECTION II PORTABLE CABINS, WASTE BINS & MISCELLANEOUS ITEMS
WASTE BINS (OUTDOOR)
Provision, Supply & Installation/fixing of wheeled waste bins moulded from special UV stabilized grades of polyethylene - each of 240 litres capacity of size TOP 570x740 BOTTOM :410x575 H: 1070 COLOUR: Military Green & Dark blue .The bins should be rust free, elegant, light weight, easy to handle and cleaning, hygienic, leak proof & durable etc. complete as per specification and approval of Engineer-in-Charge.
PORTABLE SECURITY CABIN
Provision, supply and installation/fixing of Pre-Fab security and process cabins of 3.0m clear height from FFL. The cabin base will be made from MS Mild steel structure 1.2mm thick of SHS of 38mmx 38mm having a yield strength YST 210. The MS frame is fabricated in 600mm x 600 mm C/C by proper welding and painted with red oxide primer. The framing shall have the provision of hole for electric conduiting and wiring. The cabin shall have the provision of opening of doors and windows with fitting and locks including electrical works, fittings, wiring etc. The cabin shall be provided with U channel, silicon sealants, flashings (if required), rivets, nuts, bolts etc.
Insulated Roof: - PUF insulated sandwich panels for Roof of total thickness 40-50 mm. The Panel will have Pre coated GI sheet of 0.4-0.5 mm thick on both side of Polyurethane foam with external face being Corrugated in shape for GI and PU foam between the GI sheets. The crest height of the roof panel will be 28- 30mm minimum with 195 to 250mm c/c pitch. The Pre coated sheet will be of minimum 210 mpa steel grade and will have Zinc coating of 80 gsm. The PU foam will be of density 40kg/cum (+- 2kg).
Walls: - The walls will be made of PUF Panels made of 50mm thick composite PUF sandwich between PPGI sheets. The panels shall be made of 0.4-0.5 mm Thick PPGI Sheet on both sides with 50mm thick layer of rigid Polyurethane foam of density 40 (+/- 2) kg/m3 as insulation. The Pre coated sheet will be of minimum 210 mpa steel grade and will have Zinc coating of 80 gsm. The wall panels will have tongue and groove arrangement for fixing with each other. Standard spacing to be done to accommodate electrical conduits to be fixed horizontally/vertically in the cabin.
Floor: - MS bottom frame shall be fabricated with MS pipe light weight 1.2mm SHS 38mm X 38mm in grid 600mm X 600mm CC. The Cabin shall also be provided with flooring marine plywood of 18mm thick and 1mm thick vinyl flooring . The floor shall be fixed with plinth by using steel anchoring fastener 100mm X 150mm long.
Doors: - Single leaf door of size 900x2100 x40mm made up of pre-coated GI sandwiched panels having 40 mm thick PUF insulation and density 40kg/cum (+- 2kg). For 2 Nos ATM cabins, the door shall be made of toughened glass with lockable arrangement. Windows: - The cabins will be fixed with sliding/fixed windows all around the cabins. Windows will be made up of aluminium powder coated windows with toughened glass. The size of the window along with its arrangement will be as per requirement of Engineer-in-Charge.
3.3mx3.3mx3.0m clear height from FFL
6.0mx3.3mx3.0m clear height from FFL
DOOR MAT
Supplying and placing of approved make, heavy duty door mat(plastic fiber/grass roll type) near entrance as per manufacturer's specifications. All wastage shall be to contractor's account and only the size as per actual shall be measured and paid for. with approval of Engineer-in-Charge
Dim: 1000mmX600mm
Dim: 1500mmX600mm
Dim: 1800mmX600mm
SS WASTE BIN WITH LID
Supply & Installation/fixing of staimless circular steel swing bin of grade SS304 recycle bin, Size: Diameter - 310mm and height-710mm , 22 gauge in glossy/matt. There will be one opening of 250mm dia with/without flip lid.
SMALL WASTE BINS WITH LID
Supply & Installation/fixing of stainless circular steel swing bin of grade SS304 recycle bin, Size: Diameter - 8 Inch and height-12 inch height , 22 gauge in glossy/matt having cpapcity of 10 ltrs. There will be one opening with flip lid.
SMALL WASTE BINS
Supply & Installation/fixing of staimless circular paper bin, round perforated bin of grade SS304 Size: Diameter - 8 Inch and height-12 inch height , 22 gauge in glossy/matt having capacity of 10 ltrs. There will be one opening without flip lid.
BED FOR REST ROOM
Supplying and Placing in position Single Bed of following specification. Size:- Overall size of bed shall be 2060mm (L) × 1750mm (W) × 900mm (H). Bedstead shall be 1520mm (W) x 2010mm (L) x 410mm (H)Bed structure consists of metal frame made of M.S. Channels in 1.0 mm thickness. Horizontal and bottom plinths are made of 25mm thick prelaminated particle board. Head board is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thcik PVC edge banding. Tail board is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thcik PVC edge banding. Side rail is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thcik PVC edge banding. Mattress panels of bed are made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 0.8mm thcik PVC edge banding. The bed comes in Knock-Down construction. Finish:18mm thick prelaminated particle board is in Walnut shade. metal frames are powder coated in shade met black to the thickness of 50 microns.
Bed shall also be provided with slding understorage of size 1500mm(W) x 1980mm (L) x 265mm (H). Body parts of understorage unit are made of 18mm thick prelaminated particle board, all the exposed edges are edge banded with 0.8mm thick PVC edge Banding. Door panels of understorage unit are made of 8mm thick prelaminated particle board, all the exposed edge are banded with 0.8mm PVC edge banding. Bracket for side roller in 1.2 mm thickness. The high quality hardware such as Rollers, casters, Minifix dowels. The understorage comes in Knock-Down construction. 18mm thick prelaminated particle board is in Walnut shade. Metal parts are powder coated in shade black to thickness of 50 microns. The bed shall be provided with 6 inch thick foam matteress of 40 density. Brands for Mattress: Dunlop, Godrej, Sleepwell .The bed shall also be provided with with 2 nos. microfibre pillow of size 16"X24" of gladden , Dreamswell, wakefit or equivalent make. The work shall be carried out as per the instructions received from engineer in charge.
BED FOR SECURITY BARRACK
Supplying and Placing in position Single Bed of following specification. Size:- Overall size of bed shall be 2060mm (L) × 1150mm (W) × 900mm (H). Bedstead shall be 920mm (W) x 2010mm (L) x 410mm (H)Bed structure consists of metal frame made of M.S. Channels in 1.0 mm thickness. Horizontal and bottom plinths are made of 25mm thick prelaminated particle board. Head board is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thcik PVC edge banding. . Tail board is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thcik PVC edge banding. Side rail is made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 2 mm thick PVC edge banding. Mattress panels of bed are made of 18mm thick prelaminated particle board with all the exposed edges are edge banded with 0.8mm thcik PVC edge banding. The bed comes in Knock-Down construction. Finish:18mm thick prelaminated particle board is in Walnut shade. metal frames are powder coated in shade met black to the thickness of 50 microns.
Bed shall also be provided with hinged door understorage openable from top from both sides. Body parts of understorage unit are made of 18mm thick prelaminated particle board, all the exposed edges are edge banded with 0.8mm thick PVC edge Banding. Door panels of understorage unit are made of 8mm thick prelaminated particle board, all the exposed edge are banded with 0.8mm PVC edge banding. , Minifix dowels ia make of Hettich / Ebco / Samsung. The understorage comes in Knock-Down construction. 18mm thick prelaminated particle board is in Walnut shade. Metal parts are powder coated in shade black to thickness of 50 microns. The bed shall be provided with 4 inch thick foam matteress of 40 density. The bed shall also be provided with with 1 no. microfibre pillow of size 16"X24" of gladden , Dreamswell, wakefit or equivalent make.The work shall be carried out as per the instructions received from engineer in charge.
BED FOR SECURITY BARRACK
Supplying and Placing in position Single Bed of following specification. Supplying and placing Single bed with an overall size 1950 (L) X 850-965 (W) X 750-835 (H). Head and tail panel shall be made of 50mm X 25mm X 1.2 THK Crossection and 50 mm X 25 mm X 1.2 THK M.S Structure . The Mattress understructure shall consist of square hollow section 20mm X 20mm X 1 THK M.S Structure. Head and Bottom shall be covered with 18mm thick Pre laminated particle board with 2mm thick PVC edge banding . The edge banding shall be pasted with hot melt glue at 200 degree Celsius.Mattress panel shall be made of 12 mm ply.All metal part shall be powder coating finish with DFT(Dry Film Thickness) - 35µ min. The PPCP shoes shall be insert into bottom of legs for avoid skretches on the floors.
The bed shall be provided with 4 inch thick foam matteress of 40 density. Brands for Mattress: Dunlop, Godrej, Sleepwell , Dreamswell , gladden , wakefit. The bed shall also be provided with with 1 no. microfibre pillow of size 16"X24" .The work shall be carried out as per the instructions received from engineer in charge.
WALL MIRROR
Providing and supplying wall mirror of size 1500mm (H) x 450mm (W). The mirror shall be provided with 3" teakwood frame all around for aesthetically appealing look
WOODEN WARDROBE
Supplying and placing wooden storage cabinet of the following specifications. The overall size of the storage shall be 1950mm (H) x 900mm (W) x 600mm (D). The storage shall have 2 doors. The Doors shall be made of 18mm thick PPB. One of the doors should be provided with mirror for aesthetically appealing.The work shall be carried our as per the instructions received from engineer in charge.
QUEUE MANAGEMENT SYSTEM Provision, Supply & Installation/fixing of stainless steel(SS 304 grade or higher) Q-Management system having retractable tape head mechanism comprising of, SS double belt posts of 2 ½” dia, 14” base & 950 mm tall, belt length 2.00m in color as per approval of the engineer in charge and with name printing as specified, complete with wall mounting clips at start points or wherever required.
SS SQUARE PLANTER
Provision, Supply and placing 4 Line Square Planters in Stainless Steel (SS 304 grade). Planters shall be corrosion proof having highly finished body of size 300mm X 300mmX300mm(approx. wt. 2.0 kg/Piece) complete as per specification and approval of Engineer-in-Charge.
SECTION III - MODULAR FURNITURE
FULL HEIGHT STORAGE
Supplying, Installation and placing of stackable/single unit 1950(H) x 900(W) x 450(D) mm storage , made of 0.8mm thick Prime Quality CRCA Steel, having Sliding/hinged Door with or with out top hanging arrangement to prevent derailment. Each door provided with 2 plastic roller having steel ball bearing for smooth movement of door & less noise. it has to be Snap on type aesthetically appealing die cast 5 Lever Cam Lock for safe Locking & Plastic flush & recessed / Muzzak handle. it has to be Screw type lever with hex plastic base (add in unit height min. 8 mm & additional 5mm max for adjustment), complete as per specification and approval of Engineer-in-Charge.
OVERHEAD STORAGES
Supplying and placing of overhead storage of size 900mm (W) X450mm (H) X 350mm (D) in required lengths, Top/Bottom Panel made of 0.8mm thk MS CRCA Sheet/18mm th. PLB, Side Panel made of 1.2mm thk MS CRCA Sheet /18mm th. PLB and Door Panel made of 0.6mm thk MS CRCA Sheet/18mm th.PLB. All powder Coated/PLB storages, having Removable key type 10 lever cam door lock with lock lever to lock and open the door, etc complete as per specification and approval of Engineer-in-Charge.
SIDE STORAGE & CABINET UNITS
Providing & supplying approved make, hinged door Free standing Back Side Storage & cabinet units of sizes as specified below resting on floor having door, top, sides, back, & shelves in CRCA powder coated steel. The body and Shelves of the cabinets shall be made of 0.8mm CRCA steel. The top of the cabinets shall be made of 2mm thick CRCA steel and the skirting plate shall be made of 1.2mm CRCA steel. The shelves shall be supported on Spring Steel clips and shall be adjustable at intervals of 12.5mm heights. The cabinet shall be provided with CAM Locks. The handles shall be PVC Moulded and shall be flush fitted. The cabinets shall be provided with 4 Nos. M10 levelers for height adjustment upto 25mm.The shutter shall have self-closing hinges. complete as per Specification and approval of Engineer-in-Charge.
Size 900mm(w) x715- 900mm(h) x425- 450mm(d) in 25 mm thick post formed PLB top to match the table top height.
Size 900mm(w) x 1200mm(h) x425- 450mm(d) in CRCA steel top.
SLOTTED ANGLE RACKS
Providing and fixing of 900x450x2100mm ht slotted angle rack made of MS powder coated angles/section in 16 gauge (Load carrying capacity - 75-80kg)
SECTION IV - TABLES & UNITS
TABLES FOR TOP EXECUTIVES OFFICERS
Supplying & Placing executive table with credenza unit and pedestal unit in completely knock down conditions with an overall size 1650mm X 1900mm X 750mm that is to be assembled at site. The construction of the main table shall be free standing structure constructed with the help of minifix dowels and pins. The worktop shall have the size 1650mm X 800mm made up of 50mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The table top profile shall be in rectangle shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. The top shall be enclosed with wire manager cap for electric provision. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 550mm X 300mm. The trey shall be operated on sliding channel. The table top shall be supported on particle board base gable end. The end wall of the table on the side shall be topped by gable end. It should be made up of 25mm thick Pre-laminated particle board and profile shall be in linear shape with appropriate PVC edge banding. The table shall be clad with 18mm thick modesty panel which provide structural support for the table. It should be 18mm thick pre-laminated particle board in linear shape with appropriate PVC edge banding connected with both end. There shall be buffers provided at the base to avoid scratches on the floor. The table shall have credenza unit for storage purpose with an overall size 1100mm X 450mm X 650mm. It should be made up of Pre-laminated particle board of grade II of IS 12823 with base 9mm thick and other parts 18mm thick like shutter, back, facia, side panel etc. It shall have 2 box drawer, 1 filing drawer and 1 shutter. It should be operated with the assistance of SS handle, concealed crank hinge and easily close & open with the assistance of roller channel and ball bearing channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key. It shall be mounted on injection moulded nylon castor.
A mobile pedestal shall be provided with an overall size 400mm X 450mm X 650mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, top, facia shall be 18mm thick and drawer base shall be 9mm thick. The pedestal shall have 3 nos. of drawer i.e. 2 box drawer and 1 filing drawer. The drawer shall be operated with SS handle and easily close & open with the assistance of roller channel and ball bearing channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be locked with one single key. The pedestal shall be mounted over injection moulded nylon castor. All the size shall have the tolerance of upper and lower deviation of ±10mm for board & ±0.2mm for metal. The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA membership and AIOTA certification. The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.
Supplying & placing Back storage unit with an overall size 1650mm X 450mm X 650mm. It should be made up of 18mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The entire storage i.e. side, back, shutter, shelf, skirting shall be 18mm thick and the edges shall be sealed with thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree celsius. The storage shall have shelves and 6 nos. of door shutter for ease of opening. The shutter shall be operated with concealed crank hinge with SS handle as well as MP lock mechanism. There shall be legs provided at the bottom to avoid scratches on the floor. The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA membership and AIOTA certification. The boards used should meet international standards of quality and safety, Indian standard IS 12823 grade II.
TABLE FOR MIDDLE LEVEL OFFICERS
Supplying and placing in position Executive Table, Side Unit & Credenza whose top and side panel made up of 25 mm thick plain particle board (PPB) clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate (BDL) Flat edge duly sealed with 2mm thick PVC Beading. The Modesty is 18 mm thick plain particle board (PPB) with 1 mm thick decorative laminate (DL) on both sides. Edge sealed with 2 mm thick PVC Beading. The back unit top made up of 25 mm thick plain particle board (PPB) clad with 0.6 mm thick post formed laminate and 1 mm thick Backing Laminate (BDL) Flat edge duly sealed with 2mm thick PVC Beading.The door partitions and shelves are made up of 18mm thick plain particle board (PPB) with 1mm thick decorative laminate (DL) on both sides. Eadge sealed with 2 mm thick PVC beading. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525mm X 280mm. It has Black Colour Metal Pedestal without Castors, as per approval of the Engineer-in-charge.
Executive Desk, size 1500X900X740mm
Side Unit (LHS/RHS), size 1050X450-520X680-705 mm
Credenza (Back Unit), size 1200-1280X450-520x680-705mm
OFFICE STAFF TABLES
Supplying and placing in position executive series office tables (wood/steel combi,2 lockable drawers units) complete as per specifications and as per approval of the Engineer-in-charge.
25 mm Thick Pre –laminated board with 2 mm thk. Matching lipping Stiffener provided under the top to give addition strength (1.6 mm thk. MS)
Understructure
The Pedestal is a combination of processed wood (PLB) and mild steel (MS)
2 Box drawers + 1 filing drawer combination for both pedestals
Pedestal Shell : 0.8 mm thk MS
Drawer Tray : 0.6 mm thk MS
Drawer Separator :0.6 mm MS
A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525mm X 280mm.
Pedestal Bottom cover : 0.6 mm MS
PLB Drawer fronts (18 mm PLB) to match top colour.
Drawers mounted on Double extension steel telescopic ball slides to gives full access to drawer.
‘Separators’ (0.6 mm thk.) provided in box drawers to compartmentalize space to suit individual requirements.
Sleek handles for easy grip.
Glide screws for leveling.
Independent locking arrangement (Cam lock) for each pedestal.
Modesty
MS panel (1.0 mm thk) recessed inside for more leg room
Panel is styled with cutouts (windows) to give it a trendy and up market look.
Size1650- 1665 (W) X 725-750 (D) X750 (H) mm
TABLE FOR INSPECTORS
Supplying and placing in position table of the following specifications. The overall size of the table shall be 1200mm (L) x 750mm(W) x 750mm(H). The work top shall be made of 18mm thick Prelaminated Particle Board. All work surface edges shall be duly sealed with 2mm thick PVC edgebanding. The understructure shall be 18mm thick PLB. The rectabgular component shall be 1.2mm thick CRCA with powder coating finish. The legs in the table shall be made of 38-45mm x 25-30mm x 1.2mm thick Mild Steel ERW tube with powder coating finish. The pedestal shall be made of 0.6mm thick CRCA with drawers with 10 lever cam lock. The handle in the drawers shall be made of injection moulded polypropylene. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525-550mm X 280mm.The above entire unit shall be manufactured as per specifications. The work shall be carried out as per the instructions received from engineer in charge.
1200mm (L) x 600mm(W) x 750mm(H)
CONFERENCE TABLE
Supplying and placing of Approved Make, Conference Table-20 seater , U shaped of configuration as per attached drawing and in Two Seater 1350-1360mm (W) X 600mm (D) -09 Nos., Quarter Round (One Seater) R-713 configuration-2 Nos., with Wire management facility, MDF top with Membrane foil coated with layer of polyurethane, Waterfall edge complete as per specification and approval of Engineer-in-Charge.
Table Top:-
Work Surface:Top thickness should be 25-36 mm Membrane finish, Edge profile Waterfall Edge 10mm radius on top eadge and 5mm at bottom.
Under Structure:-
Legs: Made from 36mm PPB (18+18) having a straight profile with half round eadges and clad with 0.6mm thick Post Forming laminate. Overall thickness of leg is 37.2mm.
Modesty Panel: Made from PLT (Prelaminated Twin) boards of 18mm thick.
Wire Manager:-
Wire Carrier: Made from 0.6mm thick CRCA painted.
Carrier Cover: Made from 12mm thick MDF painted overall.
Material:-
Substrate: MDF.
Skin: PVC Membrane foil (0.4mm thk) clad on the substrate MDF using PU glue for better adhesion. This foil is pre-coated with layer of polyurethane for better scratch resistance.
CONFERENCE TABLE
Supplying and placing of Approved Make, Conference Table-16 seater , U shaped of configuration as per attached drawing and in Two Seater 1350-1360mm (W) X 600mm (D) -07 Nos., Quarter Round (One Seater) R-713 configuration-2 Nos., with Wire management facility, MDF top with Membrane foil coated with layer of polyurethane, Waterfall edge complete as per specification and approval of Engineer-in-Charge.
Table Top:-
Work Surface:Top thickness should be 25-36 mm Membrane finish, Edge profile Waterfall Edge 10mm radius on top eadge and 5mm at bottom.
Under Structure:-
Legs: Made from 36mm PPB (18+18) having a straight profile with half round eadges and clad with 0.6mm thick Post Forming laminate. Overall thickness of leg is 37.2mm.
Modesty Panel: Made from PLT (Prelaminated Twin) boards of 18mm thick.
Wire Manager:-
Wire Carrier: Made from 0.6mm thick CRCA painted.
Carrier Cover: Made from 12mm thick MDF painted overall.
Material:-
Substrate: MDF.
Skin: PVC Membrane foil (0.4mm thk) clad on the substrate MDF using PU glue for better adhesion. This foil is pre-coated with layer of polyurethane for better scratch resistance.
CANTEEN TABLE:
Supplying and placing of approved make Canteen Tables, in 4 and 6 seater configurations with Chairs complete as per Specification and approval of Engineer-in-Charge.
Work-Surface: SS-304 grade top in 18 gauge sheet
Understructure: Bend/pole pipe understructure of MS. Powder coated. Pipe dia 38 mm for bend pipe and 75 mm for single post leg, 2mm thk. Understructure fitted with top by SS machine screws.Table bottom have metal insert for better holding of screw.
Legs: Glide Plastic Glide fixed at the understructure to prevent the damage of table top during stacking.
4 Seater 900 (W) X 900( D) X 750 (H ) mm including 4 chairs in approved colors/finish
6 Seater 1500 (W) X 900( D) X 750 (H ) mm including 6 chairs in approved colors/finish
M.S. understructure & PP seat Canteen Table ( 4 seater)
Providing and supplying four seater café table with PP shell seating system. The overall size of the table shall be 1200mm X 1660mm X 700mm. The table shall be supplied in completely knock down condition. The top of the table shall be made up of 22 gauge SS 202 grade sheet with 25mm thick particle board of grade II of IS 12823 inserted with an overall size 1200mm X 600mm. The profile of the table top shall be rectangle shape and the edges sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. The top shall be supported on 4mm thick hinges mounted on rounded bent pipe having Dia. 48mm with 1.6mm thick that shall be joint with rectangle beam having cross-section area 60mm X 40mm with 1.6mm thick. The seat shall be made up of one piece injection moulded polypropylene shell mounted on 50mm Dia. round pipe (welded together with rectangle beam) with 1.6mm thick with the assistance of 8mm thick solid HR steel plate. The seat shall be 260mm differ to each other. The complete understructure shall be made up of MS CRCA pipes with 50-60µ thick powder coated. The base shall be covered with plastic caps. The seat size shall be 440±10 mm(W) X 440±10 mm(D) and back size shall be 400±10 mm(W) X 290±10 mm(H), overall height shall be 680±10 mm.
CENTRE/COFFEE TABLE
Providing & placing in position center table of specified size(s) with top made in 10mm tempered glass fixed in rubber wood/teak wood frame and supported with an understructure of rubber wood / teak wood.The work shall be carried out as per the instructions received from engineer in charge.
Centre Table: 1000mm W X 600mm D X 450mm H.
Side Table: 600mm W X 600mm D X 450mm H.
STUDY TABLE WITH CHAIR-01 FOR GUEST ROOM CHAIR : High Back Dining Chair in solid rubber wood with polished finish. Material : Rubber Wood Finish : Clear lacquer finish Seat with foam cushion of density 45 and fabric. Dimension : Width 450 mm X Depth 500 mm X Height 900 mm TABLE: Study Table in finger jointed 20mm thick rubber wood with polished finish. Legs in 60X60mm solid wood. Table top size: 900 (W)X 600 (D)X750 (H) mm – 20mm thick. Finish : Clear Melamine coat
STUDY TABLE WITH CHAIR-02 FOR BARRACKS
Supplying and placing executive table in knock down condition with an overall size 900mm X 600mm X 750mm that is to be assembled at site. The worktop shall be made up of 18mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The table top profile shall be in rectangle shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. The top shall be supported on MS/CRCA rectangle pipe frame having cross-section area 25mm X 25mm with 1.2mm thick. The table Understructure shall be supplied with MS pipe having 25mm X 25mm with 1.2mm thick. 1 nos. footstep shall be provided between both side leg with the same size i.e. 25mm X 25mm with 1.2mm thick. Fixed pedestal unit shall be supplied with 1 nos. of drawer at one side. The drawer shall be central locking mechanism by one single key. The drawer shall be operated with recessed handle.
Supplying and placing visitor chair without arm ergonomically designed for user comfort and shall have asthethically appelaing design. The seat shall be made of 15 mm thick hot pressed curved plywood upholstered with high resilience polyurethane foam 25 mm thick having density 40kg/m3 with black fabric tapestry 0.6mm thick and 235 GSM and back shall be supported by MS CRCA metal pipe with breathable mesh Tapestry.The frame structure shall be supported by four legs made of MS CRCA pwder coated with 50-60 micron (DFT) round pipe of DIa 20 mm with 1.5mm thick . There shall be PPCP shoe provided at the base to avoid scratches on the floor . The seat size shall be 470mm (+- 10mm) width X 440mm (+-10mm) depth and back size shall be 400mm (+-10mm) height from seat and over all height 850mm (+- 10mm)
RECEPTION TABLE size (2400x600)
Supplying & Placing Reception table in completely knock down conditions with an overall size 2400mm X 600mm X 1000mm that is to be assembled at site. The construction of the main table shall be free standing structure constructed with the help of minifix dowels and pins. The table top shall have the combination of 18mm Particle board and 25mm MDF board. The top shall have the size 2400mm X 600mm made up of 43mm thick. The top shall be 18mm thick Pre-laminated particle board of grade II of IS 12823 with both side laminate and finish as per approved shade and top base shall be 25mm thick Medium density fibre-board with deco painted. The table shall have a upper top shelf with an overall size 1600mm X 300mm made up of 25mm thick Pre-laminated particle board. The upper top shall be supported on 25mm thick particle board base vertical panel. The top profile shall be in round shape with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edgebander machine at 200 0C. The top base MDF shall have groove.A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525-550mm X 280mm. The trey shall be operated on keyboard channel. The table shall be clad with 1mm thick modesty panel which provide structural support for the table.
The top and bottom modesty panel shall have the size 935mm X 180mm and 1050mm X 400mm respectively with 1mm thick CRCA powder coated in round shape with perforated sheet connected with both end. The main table top shall be supported on SS peg at front which mounted on the pedestal and leg made up of Pre-laminated particle board having length 620mm, with cross-section area 100mm X 100mm. A pedestal shall be provided with an overall size 400mm X 500mm X 610mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, facia shall be 18mm thick & drawer base shall be 9mm thick. The pedestal shall have 3 nos. of drawer having same size 359mm X 160mm. The drawer shall be operated with SS finish C-handle and easily close & open with the assistance of 400mm roller base bottom channel having load capacity 20Kg to enable smooth movement. The table shall be locked with central locking mechanism in which all the drawer shall be locked with one single lock. The manufacturershall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA certification .The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.
IMMIGRATION COUNTER
Providing and placing in position Immigration Counter of size 1200 x 1500 x 1200 mm as per approved drawing, 19 mm thick Boiling water proof plywood /18 mm thick (BWP) (Merino, century, Greenply,Kitply or equivalent) marine ply with 12 mm thick acrylic solid polymer of approved shade/colour (Corian/LG/ Denolex/ Staron/Hanex/Neonnex/Durlax) or any other approved equivalent colour combination and interior finish with 0.8 mm thick laminate in suede /gloss finish of approved color and pattern with all necessary frames works of block board /stainless steel screws/ SS hinges/telescopic channels for drawers/ handles /locks/bottom support /necessary cut outs /wire manager/ False Flooring with PVC Vinyl Flooring etc. includes construction of frame work , fixing of solid acrylic with necessary moulding of edges ,fixing of laminate , drawers, shutters and all necessary hardware. The work shall be caried out as per instructions received from engineer in charge.
CUSTOMS COUNTER
Providing and placing in position Immigration Counter of size 1200 x 1500 x 1200 mm as per approved drawing, 19 mm thick Boiling water proof plywood /18 mm thick (BWP) (Merino, century, Greenply,Kitply or equivalent) marine ply with 12 mm thick acrylic solid polymer of approved shade/colour (Corian/LG/ Denolex/ Staron/Hanex/Neonnex/Durlax) or any other approved equivalent colour combination and interior finish with 0.8 mm thick laminate in suede /gloss finish of approved color and pattern with all necessary frames works of block board /stainless steel screws/ SS hinges/telescopic channels for drawers/ handles /locks/bottom support /necessary cut outs /wire manager/ False Flooring with PVC Vinyl Flooring etc. includes construction of frame work , fixing of solid acrylic with necessary moulding of edges ,fixing of laminate , drawers, shutters and all necessary hardware. The work shall be caried out as per instructions received from engineer in charge.
OFFICE CUBICLES
Supplying & Placing workstation table in completely knock down conditions with an overall size 1500mm X 1500mm X 1200mm height that is to be assembled at site. The worktop shall have the size 1500mm/600mm X 1500mm/600mm made up of 25mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The top profile shall be in curvilinear shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. The top shall be supported on particle board base gable end. The end wall of the top shall be topped by gable end. It should be made up of 18mm thick Pre-laminated particle board and the profile shall be in linear shape with appropriate PVC edge banding. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525-550mm X 280mm. The trey shall be operated on keyboard channel. The workstation shall have panel based partition of 60 mm thick with overall height 1200mm. The partition shall be linear in profile and provided in front side of user. The top trim, top bar, mid bar, vertical bar, raceway, skirting shall be made up of aluminium extrusions (pre-treated) and duly powder coated with 40-50µ thick.
The trims shall have the size 60mm X 19mm with 1.5mm thick covered with Die cast end caps on joints 2 ways, 3 ways & 4 ways (L-cover for corner, T-cover for middle section wherever required). The aluminium raceway shall be situated below the worktop with an overall size 116mm(H) X 60mm(D) with 1.4 mm cover thickness and 2mm back thickness as per requirement of inlaying the electrical management and carrying the wire horizontally. The exposed vertical and horizontal faces of the frames shall be snap fitted with trims. There shall be soft-board (with fabric) provided at front of the user. Laminated bottom tile shall be situated below the work top. The Partition shall have concealed wire management capabilities and should be engaged for responsive and safe operations of power, telecommunications and data (LAN) and has separate components for electrical, data and telephone cables having adequate capability of both the vertical and horizontal wire movements.
Slots/cut-outs should be given on raceways to fix all electrical and data points. Zinc coated small top support brackets shall be fixed on the partition for table top support. To protect the wall from kicks, abrasion and serve as a decorative moulding, skirting shall be situated at bottom. Adjustable leveller shoe shall be provided at bottom of the partition to avoid scratches on the floor. Mobile pedestal shall be provided with an overall size 400mm X 450mm X 680mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, top, facia shall be 18mm thick and drawer base shall be 9mm thick. The pedestal shall have 3 nos. of drawer i.e. 2 box drawer and 1 filing drawer. The drawer shall be operated with SS handle and easily close & open with the assistance of roller channel and ball bearing channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key. The pedestal shall be mounted on injection moulded nylon castor. . The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA certification . The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.
LINEAR WORKSTATION
Supplying & Placing workstation table with 600mm return partition on both side in completely knock down conditions with an overall size 1500mm X 1200mm height that is to be assembled at site. The worktop shall have the size 1500mm X 600mm made up of 25mm thick Pre-laminated particle board of grade II of IS 12823 with approved laminate and finish as per approved shade. The top profile shall be in curvilinear shape and the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. The top shall be supported on particle board base gable end. The end wall of the top shall be topped by gable end. It should be made up of 18mm thick Pre-laminated particle board and the profile shall be in linear shape with appropriate PVC edge banding. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 525-550mm X 280mm. The trey shall be operated on keyboard channel. The workstation shall have panel based partition of 60 mm thick with overall height 1200mm. The partition shall be linear in profile and provided in front side of user. The top trim, top bar, mid bar, vertical bar, raceway, skirting shall be made up of aluminium extrusions (pre-treated) and duly powder coated with 40-50µ thick.
The trims shall have the size 60mm X 19mm with 1.5mm thick covered with Die cast end caps on joints 2 ways, 3 ways & 4 ways (L-cover for corner, T-cover for middle section wherever required). The aluminium raceway shall be situated below the worktop with an overall size 116mm(H) X 60mm(D) with 1.4 mm cover thickness and 2mm back thickness as per requirement of inlaying the electrical management and carrying the wire horizontally. The exposed vertical and horizontal faces of the frames shall be snap fitted with trims. There shall be soft-board (with fabric) provided at front of the user. Laminated bottom tile shall be situated below the work top. The Partition shall have concealed wire management capabilities and should be engaged for responsive and safe operations of power, telecommunications and data (LAN) and has separate components for electrical, data and telephone cables having adequate capability of both the vertical and horizontal wire movements.
Slots/cut-outs should be given on raceways to fix all electrical and data points. Zinc coated small top support brackets shall be fixed on the partition for table top support. To protect the wall from kicks, abrasion and serve as a decorative moulding, skirting shall be situated at bottom. Adjustable leveller shoe shall be provided at bottom of the partition to avoid scratches on the floor. Mobile pedestal shall be provided with an overall size 400mm X 450mm X 680mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, top, facia shall be 18mm thick and drawer base shall be 9mm thick. The pedestal shall have 3 nos. of drawer i.e. 2 box drawer and 1 filing drawer. The drawer shall be operated with SS handle and easily close & open with the assistance of roller channel and ball bearing channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key. The pedestal shall be mounted on injection moulded nylon castor. . The manufacturer shall have quality and safety assurance like ISO-9001:2015, ISO-14001:2015 and ISO-18001:2007, BIFMA certification . The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.
S.S. COUNTER
Supplying and placing of approved make L-shape S.S. Counters,SS-304 grade top in 18 gauge sheet with steel post as per Specification and approval of Engineer-in-Charge.
SECTION V - SEATING/RESTING SYSTEMS
Providing & Supplying of cushioned sofa sets in approved fabric with in 3,2 & 1 seat configurations to the satsfaction of Engineer -in -charge.
Supplying and placing a single seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam 80mm thick having density 40Kg/m³ in seat and 50mm thick having density 32Kg/m³ in back. There shall be cushion arm provided padded with high resilience polyurethane foam 19mm thick having density 40Kg/m³. The complete structure shall be upholstered with chocolate brown leatherite tapestry 1±0.2 mm thick and 571 GSM. The understructure shall be supported by pipe frame loop leg of SS shiny chrome finish having size 720mm X 535mm with cross-section area 40mm X 20mm / 30mm x 30mm. There shall be shoe provided at the bottom to avoid scratches on the floor.
Dimensions :
One Seater- The seat size shall be 510±10 mm(D) X 540±10 mm(W), seat height = 435±10 mm, overall width = 860±10 mm, overall depth = 770±10 mm & overall height = 780±10 mm.
Two Seater - The seat size shall be 510±10 mm(D) X 1040±10 mm(W), seat height = 435±10 mm, overall width = 1360±10 mm, overall depth = 770±10 mm & overall height = 780±10 mm.
Three Seater-The seat size shall be 510±10 mm(D) X 1540±10 mm(W), seat height = 435±10 mm, overall width = 1860±10 mm, overall depth = 770±10 mm & overall height = 780±10 mm.
Supply, Providing and Placing of following types of Chairs
TOP EXECUTIVE CHAIR
Providing and supplying a high back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of natural wood and combination of (18+6) mm thick double layered moulded commercial plywood padded with high resilience polyurethane foam (50+25)mm thick having density (40, 32)kg/m³ in seat and (40+25)mm thick having density (32, 23)kg/m³ in back. The same shall be upholstered with leatherite tapestry 0.8mm thick and 535 GSM. The backrest shall be made by keeping the natural curvature of the spine which helps to provide lumbar support as well as head support. The chair shall be supplied with PP arm with cushion top. For seating durability the chair shall have swivel tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 65mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standards. The Pedestal should have five legged injection moulded polypropylene having pitch circle dia. 700 mm fitted with 5 nos. twin wheel castors. The castors of the chair should be injection moulded in black 30% glass filled nylon, confirming to ANSI/BIFMA standards X5.1-2011 tested to perform 98,000 cycles with 250lbs load. The seat size shall be 520±10 mm(D) X 560±10 mm(W)and back size shall be 560±10 mm(W) X 660±10 mm(H) from seat. Overall height shall be = 1125±10 mm, overall depth = 700±10 mm & overall width = 660±10 mm. The work shall be caried out as per instructions received from engineer in charge.
TOP HEAD CONFERENCE CHAIR
Providing and placing in position high back chair of the following specifications. The seat shall be made of insert moulded polyurethane foam upholstered with foam laminated mesh fabric. The seat is made of plywood and upholstered with moulded polyurethane foam and foam laminated mesh fabric. Seat assembly size should be 480-510mm (W) x 480-525mm (D). The armrests should be adjustable in nature. chair should be provided with 360 degree revolving, single point control, tilt tension sdjustment, 4 position locking.. The twinwheel castors are having injection moulded in black nylon. The chair shall be provided with one headrest for confortable long hour seating. The work shall be caried out as per instructions received from engineer in charge.
CONFERENCE CHAIR
Providing and placing in position mid back chair of the following specifications. The seat shall be made of insert moulded polyurethane foam upholstered with foam laminated mesh fabric. The seat is made of plywood and upholstered with moulded polyurethane foam and foam laminated mesh fabric. Seat assembly size should be 480-510mm (W) x 480-525mm (D). The armrests should be adjustable in nature. chair should be provided with 360 degree revolving, single point control, tilt tension sdjustment, 4 position locking.. The twinwheel castors are having injection moulded in black nylon. The work shall be caried out as per instructions received from engineer in charge.
TOP EXEC. VISITOR
Providing and placing in position visitor chair of the following specifications. The seat shall be made of insert moulded polyurethane foam upholstered with foam laminated mesh fabric. The seat is made of plywood and upholstered with moulded polyurethane foam and foam laminated mesh fabric. Seat assembly size should be 480- 510mm (W) x 480-525mm (D). The armrests should be adjustable in nature. Chair is provided with leg frame assembly made of Mild Steel attached to base of the seat. The work shall be caried out as per instructions received from engineer in charge.
STAFF CHAIR
SEAT/BACK ASSY.:The seat is made up of 1.2 cm. thk. hot pressed plywood upholstered with fabric and moulded Polyurethane foam. The back is a fabricated tubular frame assembly powder coated / Nylon and upholstered with a High Tenacity Polyester mesh fabric.
LUMBAR SUPPORT ASSY.:The back assembly consists of a height adjustable cushioned Lumbar support pad which can be adjusted through 2 projecting knobs at the rear side of the back. The Lumbar Pad can be adjusted by 6.0cm in height.
POLYURETHANE FOAM:The polyurethane foam for seat is moulded with density = 45 +/-2 Kg./m3 and Hardness = 20 +/- 2 on Hampden machine at 25% compression.
ARMRESTS (ADJUSTABLE): The armrest having only Up-Down adjustment which is provided in armrest structure. Armrest Top is made up of PU with metal insert fitted on the armrest structure.
Syncrho MECHANISM: The mechanism is designed with the following features:
· 360° revolving type.
· Single point control.
· Front pivot for tilt with feet resting on ground ensuring more comfort.
· Tilt tension adjustment.
· 1-position locking with anti-shock feature.
· Seat back tilting ratio of 1:3(11° Seat Tilt /33° back tilt).
PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment of 10.0cm
PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors. The pedestal is 68.0 cm. pitch-centre dia. (78.0 cm with castors).
TWIN WHEEL CASTORS: The twin wheel castors are injection molded in Polypropylene black. The work shall be caried out as per instructions received from engineer in charge.
MULTI SEATER PUBLIC BENCH WITH BACK
Supplying and placing three seater bench that shall be constructed from metal frame. The seat and back shall be made of high quality cold rolled MS/CRCA sheet of 1.2m thick pressed and welded to form the shape with the assistance of MS pipe. The seat and back shall be electrostatically coated with 40-50µ thick epoxy powder and then cured under heat to allow it to form a skin. The seat and back shall have perforated sheet.The seat shall be supported on 2.5mm thick powder coated HR steel which is mounted over rectangular frame having cross section 40mm x 60mm with 1.6mm thick duly powder coated. The armrest shall be made up of MS/CRCA powder coated having cross-section area 33mm x 13mm with 1.6mm thick. The base or leg shall be made up of CRCA pipe 50 mm dia. 1.6mm thick. There shall be plastic shoe provided at the bottom to avoid scratches on the floor. The individual seat size shall be 410±10 mm(D) X 420±10 mm(W), seat height = 440±10 mm, overall width = 1700±10 mm, overall depth = 610±10 mm & overall height = 800±10 mm.
PUBLIC LOUNGE CHAIR
Suppling and placing of three seater chair without cushion :- The seat shell should be a welded assembly of seat,back and side frame. The seat and back should be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They should be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel.The welded assembly should be powder coated ( DFT 40-60 microns ). The seat has a front water fall edge to provide popliteal clearance for comfortable seating. It also has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flat surfaces of seat and back aids in easy maintenance. * SEAT SIZE : 47.8 cm (W) x 44.6 cm (D) * BACK SIZE : 41.6 cm (W) x 23.0 cm (H) Understructure assembly consshould be ts of connecting beam and leg assembly made of M.S. E.R.W. oblong tube of size 7.5±0.03cm x 2.5±0.03cm x 0.2±0.016cm thk.The welded structure assembly should be powder coated ( DFT 40-60 microns ).The leg assembly should be fitted with shoes and levellers in Nylon. The leg structure should be designed with minimal should be a of contact close to ground providing easy access for cleaning purposes. The shoes fitted to leg assembly help in aligning the structure for back to back arrangements. Levellers take should be of uneven flooring.Connecting beam should be fitted with snap locking end cap.lt also aids in side-by-side understructure alignment . Armrest assembly consshould be ts of armrest frame and armrest pad . The armrest frame should be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it should be powder coated ( DFT 40-60 microns ). Armrest pad should be injection molded in Nylon and should be fitted onto the armrest frame.Size in mm - 1690 ± 10(L) X 670 ± 10(D) X 790 ± 10(H)
PUBLIC LOUNGE CHAIR WITH CUSHION
Supplying & Placing three seater bench with cushion and leatherite tapestry :- The seat shell should be a welded assembly of seat,back and side frame. The seat and back should be made of 0.12±0.013cm thk CR steel sheet with oblong perforations.They should be welded to sideframe of size 3.2±0.05cm x 0.5 ± 0.05 cm thk HR steel.The welded assembly should be powder coated ( DFT 40-60 microns ). The seat has a front water fall edge to provide popliteal clearance for comfortable seating. It also has a buttock support curve that not only provides rear support but also prevents small children from falling through the gap between seat and back. Clean and flat surfaces of seat and back aids in easy maintenance. * SEAT SIZE : 47.8 cm (W) x 44.6 cm (D) * BACK SIZE : 41.6 cm (W) x 23.0 cm (H) Understructure assembly consshould be ts of connecting beam and leg assembly made of M.S. E.R.W. oblong tube of size 7.5±0.03cm x 2.5±0.03cm x 0.2±0.016cm thk.The welded structure assembly should be powder coated ( DFT 40-60 microns ).The leg assembly should be fitted with shoes and levellers in Nylon. The leg structure should be designed with minimal should be a of contact close to ground providing easy access for cleaning purposes. The shoes fitted to leg assembly help in aligning the structure for back to back arrangements. Levellers take should be of uneven flooring.Connecting beam should be fitted with snap locking end cap.lt also aids in side-by-side understructure alignment . Armrest assembly consshould be ts of armrest frame and armrest pad . The armrest frame should be made up of size 3.175±0.05cm x 0.47±0.027cm thk HR steel and it should be powder coated ( DFT 40-60 microns ). Armrest pad should be injection molded in Nylon and should be fitted onto the armrest frame.Size in mm - 1690 ± 10(L) X 670 ± 10(D) X 790 ± 10(H)
SECTION VI - DISPENSARY ITEMS
WHEEL CHAIR
Providing and supplying of Wheel Chair, Overall Size: (L) 1050 x (W) 700 x (H) 980mm.Fix frame structure should be made of section 25.41 dia 1.2mm CRCA finish. Cross bar should be made of CRCA steel with section 25.4 x 1. 2mm.Rear Wheel:24-inch Solid mag wheels with alloy in the rim. Integrated hand rim provides to drive the wheel chair of section 16x1.2mm of epoxy powder coated finish Front Wheel: 6-inch HUB made of PA polymer and outer with solid rubber. Leatherite strap for calf rest & leatherite cushion for seat. Adjustable aluminum die cast foot rest with up down & swivel type mechanism. Handles should be made of moulded rubber grip to push the wheelchair. Hand brakes should be provided to lock the wheelchair at desired location. Anti-rust epoxy powder coated finish,complete as per specification & approval of Engineer-in-Charge. .
LAB STOOL
Supplying and Placing of Stools with/ with out back rest, The seat is made up of 1.2 cm thick Commercial Grade plywood with moulded Polyurethane foam and are pholstered with replaceable fabric covers. Seat shall be of 40cm diameter and shall be 360 degrees revolving type. The polyurethane foam shall be moulded with density 45 +/-2 kg/m3 and Hardness 20 +/- 2. The pedestal shall be fabricated from 0.2cm. thick CR steel, powder coated and fitted with an injection moulded black Polypropylene Hub Cap and 5 nos. twin wheel castors. (Castor wheel diameter 5.0cm.) The pedestal shall be 55.0cm pitch-circle diameter (65.0 cm with castors and supported by foot ring of dia 52.00 cm).It shall consist of 650mm (W) X 650mm (D) X 450/565 mm (seat Height), as per the specification and approval of Engineer-in-Charge.
BED SIDE LOCKER
Supplying and placing of approved make bed side lockers having one cabinet and one drawer unit The drawer as well as cabinet is provide with cam lock. There is a gap between the drawer unit and cabinet, to keep the general items for frequent use. Castors are provided for easy handling. A stainless steel tray of SS having 0.8mm thk. is to be provided at top with raised borders on 3 sides. Corner tube of the frame shall be made up of ERW Round tube of 25.04mm dia & 1.2mm in thickness. Drawer should be of CRCA 0.8 mm thick. Drawer has ball slide for easyoperation and Lock for the safety. Telescopic ball slides of MS with zink palting has to be used for easy and smooth operation of the drawer. Cabinet of CRCA 0.8mm thk is to be provided with a lock. Plastic molded castor, 2 castor with lock of 50mm dia has to be provided. it has to be Termosetting epoxy polyester, RAL white powder Coating. complete as per specification & approval of Engineer-in-Charge.
Overall Sizes 420 mm (L) X 400 mm ( W) X 840mm (H)
SINGLE STEP STOOL
Providing and supplying Single step stool should have Overall Dimension - 450mm X 280mm X 230mm. The step stool should step made of 18g CRCA sheet. welded on M.S. tubular frame of 25.4mm x18g fitted with aluminium tread flats of size: 430 mm (L) x 30 mm (W) x 3 mm thick, fitted by aluminium pop rivet. All MS parts should be pre-treated in Seven Tank & Powder Coated. legs fitted with pvc. shoe with nylon reinforcement. The participating brand must have all the prevalent quality & safety related certifications. The participating brand must have all the prevalent quality & safety related certifications like ISO:9001, ISO:50001, ISO:14001, ISO 45001:2018, BIFMA, AIOTA for one or more product, Green Guard certificate for any one product atlest issued by UL of USA., complete as per specification & approval of Engineer-in-Charge.
PATIENT'S BED
This bed is a plain bed used in the recovery ward. Overall dimension: 2160 mm (L) X 910 mm ( W) X 610 mm (H) . The bed frame is of ERW Rect. tube of section 30mm X 60 mm & 1.6mm thick. The lying surface frame is of ERW Round Tube having 25.4mm dia and 1.6mm thickness. Head board/Leg board/Frame is of ERW Round Tube having 19mm dia/ 25.4mm dia & 31.75mm dia and 1.2mm thickness. Higher diameter tube provides a sturdy understructure. Leg Shoe NYLON For avoiding wear of legs. Sheet metal Lying surface of 1.2 mm thickness CRCA, is coated with anti-microbial and anti rust powder. Lying surface area consists of mattress retainer to define the position of the mattress. Anti rust and thermosetting epoxy polyester,formulated to fulfill the requirements for surface protection.Color: All powder coated parts in RAL white. Plastic parts in Pantone Cool Grey , complete as per specification & approval of Engineer-in-Charge.
PASSENGER BAGGAGE TROLLEY
Providing and supply of Baggage trolley of SS 304 grade having a Size-36"x15/20"x40" with wheel and load carrying capacity of 100-120 Kgs. The trolley is made of Made up of 25mm Round Pipe & 10mm bar and Having 4 nos wheel of 6"x1.5" and 5"x11/4".
SECTION VII - OUTDOOR SEATINGS
OUTDOOR CHAIR/BENCH
Supply, Providing and fixing of Outdoor Chair/Bench consisting of 2 Nos.L-shape base support in grey cement color (thickness:100 mm, Back height:1000 mm, front height:450 mm, Base width:620mm) and 5 Nos. reinforced concrete planks in red color of size 1500mm X 100mm X 50mm, and 1 No. of reinforced concrete plank of size 1500mm X 200mm X 50mm. Overall Dimensions: Seating length of the Bench:1500 mm; Seating height of the Bench:450 mm; Total height of the Bench:1000 mm. All components are reinforced suitably for long use and to prevent damage during handling, transportation, and erection. All parts are joined together with galvanized nuts & bolts of suitable size and all bolts are sealed after assembly. Bench top and back planks are treated with special anti-corrosive, water proof coating so as to make surfaces glossy and water proof. All components are manufactured by using M-30 grade of Concrete using vibro compaction process.
SQUARE TABLE WITH FOUR BENCHES
Supply, Providing and fixing of Square Table with Four Benches consisting of 4 Nos. base support in grey cement, 1 Nos. Table top of size 1000mm X 1000mm X 50mm thickness in terazzo or red colour finish, and 4 Nos. benches of size 1000mm length X 350mm width X 50mm thickness in red colour finish. Overall Dimensions: Height of table:780 mm; Height of benches:450 mm. All components are manufactured by using M-30 grade of Concrete using vibro-compaction process. Reinforced suitably to promote long use and to prevent damage during handling, transportation, & erection. All the components are joined together with galvanized nuts & bolts, so as to make one composite table & bench. Table and bench tops are treated with special anti-corrosive, water proof coating so as to make surfaces glossy and water proof.
TREE GUARD
Supply, Providing and fixing of Tree Guard consisting of four panels of size 1860mm (Height) X 600mm (Width) X 25/35mm (thickness); Size of opening: 100mm X 100mm. Manufactured with M-30 grade of concrete using vibro-compaction process using jointless FRP moulds so as to achieve shuttering finish. Suitably reinforced to promote long use and to prevent damage during handling, transportation & erection.
RAISE FLOOR
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of : a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level.
The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange).
The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
300 mm Finished Floor Height (FFH)
Curtain with rod & holders (2nos) with Stand for Doctors Room
Providing and supplying of Three Fold Screen, Overall Dimension - 1675mm (H) X 2450mm (L), MS Frame with Curtain.All steel components shall be 40-60µ thick (DFT) powder coated after 7 tank pre-treatment process flow.The participating brand must have all the prevalent quality & safety related certifications like ISO:9001, ISO:50001, ISO:14001, ISO 45001:2018 , BIFMA, AIOTA for one or more product, Green Guard certificate for any one product atlest issued by UL of USA, complete as per specification & approval of Engineer-in-Charge.
Curtain with rod & holders (2nos) for Barracks
Providing and supplying main curtains with curtain back fabric. The main curtain fabric will be minimum 250 GSM and the back curtain fabric will be minimum 150 GSM. The curtain to be provided with stainless steel or powder coated curtain rods , wall brackets , finials etc . complete as per direction of EIC.
Rod length in running meter
Curtain fabric area
SIGNAGE
Providing, Supplying & fixing of Sign Boards made of S-304 grade Stainless steel Pipes with braces of SS grade S-304 of square pipe flats rectangular section etc. including , cutting argon welding polishing, buffing complete with necessary holes nuts, bolts & caps, anchor plates of SS grade ASTM – 304 as per size , drawing and to the satisfaction of Engineer in charge. The Signage Substrate shall be of 4mm ACP sheet with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages with overlay sheeting / HIGH INTENSITY PRISMATIC GRADE Type IV / Cast Vinyl to be fixed with Very High Bond tape of 24mm wide and 2.3mm thick, to the back support frame of 19mm X 24mm X1.2mm thick SS Rectagular Pipe. Complete with desired foundations ( as per details ) including Excavation PCC1:4:8, RCC 1:2:4 , Center shuttering , Foundation bolts and curing . All stainless steel items shall be of S-304 Grade (EXTERNAL SIGNAGES) (Material should be in compliance with Code of practise for Road signs, Indian Road congress 2010, IRC-67-2010)
(Design Nos.1) Providing, Supplying & fixing Single sided Sign Board of size 1930 mm x 1320 mm (50 mm dia SS pipe of S-304 grade 1.6mm thick) with inner frame of 1830mm x 1220mm ( of 19 mm x 24mm rectangular, 1.20mm thick SS pipe of S-304 Grade) along with diagonal support also of 19mm x 24mm rectangular, 1.20mm thick SS pipe of S-304 Grade, with sign substrate of 1830mm x 1220mm of 4mm ACP sheet with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages and symbols accordingly, fixed to inner frame with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board shall have a leg support of 168mm dia 3mm thick SS pipe of S-304 grade of height 4420mm, with necessary holes, nuts bolts & caps. The boards shall be grouted in a foundation size of 1200mm x 900mm x 900m with CC 1: 2: 4 laid with the help of shuttering. All relevant specs to confirming to detail drawing enclosed.
(Design Nos. 2) Providing, Supplying & fixing Single sided Sign board of size 974mm x 1284mm ( 32mm dia SS pipe of S-304 grade 1.6mm thick ). with inner frame of 910mm x 1220mm (of 19mm x 24mm rectangle, 1.2mm Thick SS pipe of S-304 Grade ) along with diagonal support also of 19mm x 24mm sectangle, 1.2mm Thick SS pipe of S-304 Grade, with sign substrate of size . 910mm x 1220mm, of 4mm ACP sheet with face fully covered with RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols accordingly, fixed to inner frame of 910mm x 1220mm of ( 19mm x 24mm square, 1.2mm Thick SS pipe of S-304 Grade ) with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board shall have a one leg support of 60mm dia 2mm thick SS pipe of S-304 grade of height 4.084m with Hold fast The boards shall be grouted in a foundation size of 600mm x 600mm x 900mm with CC 1: 2: 4 laid with the help of shuttering Complete. All relevant specs confirming to detail drawing enclosed.
(Design Nos. 3) Providing Supplying & fixing Double Sided Sign board of size 1930mm x 1320m ( 50mm dia SS pipe of S-304 grade 1.6mm). with inner frame of 1830mm x 1220mm (of 19mm X 24mm X 1.2mm thick Rectangular SS pipe of S-304 Grade ) along with diagonal support also of 19mm X 24mm X 1.2mm thick Rectangular pipe of S-304 Grade, with sign substrate of size 1830mm x 1220mm, of 4mm ACP with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols accordingly, fixed to inner frame of 1830mm x 1220mm of (19mm X 24mm X 1.2mm Thick Rectangular pipe of S-304 Grade ) with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board shall have a two leg support of 73mm dia 2mm thick SS pipe of S-304 grade of height 4.04m and 3.4mmm respectively, with necessary holes, nuts bolts & caps. The boards shall be fixed on two nos. foundations of size 900mm x 900mm x 1200m with CC 1:2:4 laid with the help of shuttering. All relevant specs confirming to detail drawing enclosed.
(Design Nos. 4) Providing, Supplying & fixing Single sided Sign board of size 974mm x 673mm & 974mm x 368mm ( 32mm dia SS pipe of S-304 grade 1.6mm thick ). with inner frame of 910mm x 610mm & 910mm x 304mm (of 19mm x 24mm rectangular , 1.2mm Thick SS pipe of S-304 Grade ), with sign substrate of size 910mm x 610mm & 910mmx 304mm, of 4mm ACP with face fully covered with RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols accordingly, fixed to inner frame of 910mm x 610mm & 910mmx 304mm of ( 19mm x 24mm square, 1.2mm Thick SS pipe of S-304 Grade ) with the help of Very High Bond tape of 24mm wide and 2.3mm thick .The board shall have a one leg support of 60mm dia 2mm thick SS pipe of S-304 grade of height 2840mm with Hold fast The boards shall be grouted in a foundation size of 600mm x 600mm x 600mm with CC 1: 2: 4 laid with the help of shuttering Complete. All relevant specs confirming to detail drawing enclosed.
(Design Nos. 5) Providing, Supplying & fixing Single sided Sign board of size 1320mm x 2540mm ( 50mm dia SS pipe of S-304 grade 1.6mm thick ). with inner frame of 1220mm x 2440mm (of 19mm x 24mm rectangle, 1.2mm Thick SS pipe of S-304 Grade ) along with diagonal support also of 19mm x 24mm rectangle, 1.2mm Thick SS pipe of S-304 Grade, with sign substrate of size 1220mm x 2440mm, of 4mm ACP with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols accordingly, fixed to inner frame of 1220mm x 2440mm of ( 19mm x 24mm rectangle, 1.2mm Thick SS pipe of S-304 Grade ) with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board shall have a one leg support of 168mm dia 3 mm thick SS pipe of S-304 grade of height 4040mm with base plate of 10mm thick SS plate of size 600mm x 600mm with 4 Nos. stiffeners of 10mm SS plate of S-304 grade. The boards shall be fixed on a foundation size of 1500mm x 900mm x 900mm with CC 1: 2: 4 laid with the help of shuttering and 12 Nos. of foundation bolts of 20mm dia SS, S-304 grade of 600mm length Complete. All relevant specs confirming to detail drawing enclosed.
WALL/ PILLAR MOUNTED EXTERNAL SIGNAGE (Design Nos. 6) Providing, Supplying & fixing Single sided Sign Board of size 450 mm x 450 mm with suitable inner frame and proper support, with sign substrate of suitable size of 4mm ACP sheet with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages and symbols accordingly, fixed to inner frame with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board is to be fixed on RCC wall/pillar with dash fasteners of SS pipe of S-304 grade. All stainless steel items shall be of S-304 Grade ( EXTERNAL SIGNAGES) (Material should be in compliance with Code of practise for Road signs, Indian Road cingress 2010, IRC-67-2010)
WALL/ PILLAR MOUNTED EXTERNAL SIGNAGE (Design Nos. 7) Providing, Supplying & fixing Single sided Sign Board of size 600 mm x 450 mm with suitable inner frame and proper support, with sign substrate of suitable size of 4mm ACP sheet with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages and symbols accordingly, fixed to inner frame with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board is to be fixed on RCC wall/pillar with dash fasteners of SS pipe of S-304 grade. All stainless steel items shall be of S-304 Grade ( EXTERNAL SIGNAGES) (Material should be in compliance with Code of practise for Road signs, Indian Road cingress 2010, IRC-67-2010)
WALL/ PILLAR MOUNTED EXTERNAL SIGNAGE (Design Nos. 8) Providing, Supplying & fixing Single sided Sign Board of size 600 mm x 900 mm with suitable inner frame and proper support, with sign substrate of suitable size of 4mm ACP sheet with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages and symbols accordingly, fixed to inner frame with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board is to be fixed on RCC wall/pillar with dash fasteners of SS pipe of S-304 grade. All stainless steel items shall be of S-304 Grade ( EXTERNAL SIGNAGES) (Material should be in compliance with Code of practise for Road signs, Indian Road cingress 2010, IRC-67-2010)
Double Sided Overhead Retro Reflective Sign Boards
Providing, Supplying & fixing of Double Sided Overhead Retro Reflective Sign Boards made of 4mm thick ACP Sheet with face and rear fully covered with RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages with overlay sheeting, with support frame structure of 72 mm X 72 mm x 2 mm SS Pipe of S-304 grade side and inner frame of 7856 mm x 1530 mm (of 19 mm X 24 mm X 1.2 mm thick Rectangular pipe of S-304 Grade) along with vertical support of 19 mm X 24 mm X 1.2 mm thick Rectangular pipe of S-304 Grade, with signage fixed with Very High Bond tape of 24 mm wide and 2.3 mm thick and rivets. Size of the board 8000 mm X 1674 mm. All relevant specification confirming to detail drawing enclosed.
Over Head Gantry Structure
Fabrication Supplying & Erecting of Over Head Gantry structure made of steel work in built up tubular (round, suare or rectangular hollow tubes etc. trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete : Hot finished seamless type tubes. The whole gantry shall be painted with 2 Coat of Epoxy paint of desired colour.
The gantry shall be erected on two nos. foundation of size 3500 mm x 2000 mm x 2580 mm with pedestal size of 900 mm x 900 mm x 1830 mm and footing of size 3500 mm x 2000 mm x 600 mm of RCC of 1: 2: 4 and PCC of 1:4:8 in size 3550 mm x 2050 mm x 150 mm with reinforced steel of 1750 Kg, 12 mm dia and 10 mm dia TOR steel with 12 foundation bolts of 1220 mm length and 25 mm dia for one foundation complete with center shuttering. Complete as per approved drawing and to the satisfaction of engineer in charge. (Detail as per enclosed drawing)
Fascia Sign Board Providing, Supplying & fixing of Facia Sign Boards made of 4mm thick ACP Sheet with face covered with RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting and messages with overlay sheeting, with edge support frame structure of 72mm X 72mm X 2mm SS Pipe of S-304 grade and 19mm x 24mm x 1.5mm inner frame with diagonals and bracing. Messages and graphics shall be plotter cut with overlay sheeting or HIGH INTENSITY PRISMATIC GRADE Type IV fixed with Very High Bond tape of 24mm wide and 2.3mm thick and rivets, fixed on to a existing structure with the help of suitable expansion fastners. (Detail as per enclosed drawing) ( EXTERNAL SIGNAGES) Material should be in compliance with Code of practise for Road signs, Indian Road congress 2010, IRC-67-2010)
INTERNAL SIGANGES
Supplying & fixing of Emergency Escape signages made of 1mm SS sheet with face fully covered with Photo-luminescent sheet with message and letters Plotter / Electronically cut text of vinyl lamination. (EXTERNAL SIGNAGES) Material should be in compliance with Code of practise for Road signs, Indian Road cingress 2010, IRC-67-2010) (INTERNAL SIGNAGES) Material should be in compliance with Code of practise for Road signs, Indian Road cingress 2010, IRC-67-2010)
Fire Extingusher Boards size (250 mm x 250 mm)
Fire Exit (4 Nos.) (250 mm x 250 mm)
Ceiling Hung Sign Board-Single Sided
Manufacturing, Supplying & fixing of ceiling hung sign board of size 900 mm x 300 mm (Single Sided) as shown in the drawing with all necessary texts and symbols. Sign Board shall be made of 4 mm Thick ACP Fully covered with High Intensity Micro Prismatic Sheting (Type IV) with powder coated aluminium frame work of specified sections. Supported with frame of 19 mm x 24 mm x 1.2 mm thick SS rectangle pipe and 25 mm dia. pipe stainless steel pipe (S-304 grade). (INTERNAL SIGNAGES) Material should be in compliance with Code of practise for Road Airport signs, Indian Road congress 2010, IRC-67-2010) Conference Hall (1 Nos.)
Ceiling hung sign board of size (Double Sided)
Manufacturing, Supplying & fixing of ceiling hung sign board of size 900mm x 300mm (Double Sided) as shown in the drawing with all necessary texts and symbols. Sign Board shall be made of 4mm Thick ACP Fully covered with High Intensity Micro Prismatic Sheting (Type IV) with powder coated aluminium frame work of specified sections. Supported with frame of 19mm x 24mm x 1.2mm thick SS rectangle pipe and 25 mm dia. pipe stainless steel pipe (S-304 grade). (INTERNAL SIGNAGES) Material should be in compliance with Code of practise for Road Airport signs, Indian Road congress 2010, IRC-67-2010) Exit/Entry (2 Nos)
Manufacturing, Supplying & fixing of S.S.Plate of following sizes made of 2mm SS sheet with message and letters Plotter / Electronically cut text of vinyl lamination including all nuts, bolts and other accessories. (Material should be in compliance with Code of practise for Road and Airport signs, Indian Road congress 2010, IRC-67-2010) a) Ladies Toilet (15 Nos.) ( Size 150 mm x 150 mm) (Only figure Based) b) Gents Toilet (15 Nos.) ( Size 150 mm x 150 mm) (Only figure Based) c) Handicapped Toilet (15 Nos.) ( Size 150 mm x 150 mm) d) Child Care (3 Nos.) ( Size 150 mm x 150 mm) e) Wash Room ( Size 300 mm x 100 mm) (Figure + Text based) (40 Nos.)
f) Drinking water ( Size 300 mm x 100 mm) (35 Nos) g) Dining Hall (6 nos.) h) Immigration ( 6 ) i) Customs (6) j) Retail Shops (4) k) Exit (10) l) Conference Room ( Size 300 mm x 100 mm) 2 No. m) Waiting Hall ( Size 300 mm x 100 mm) 5 No. n) Tourist Information Centre ( Size 300 mm x 100 mm) 5 No. o) Restricted Area ( Size 300 mm x 150 mm) (3 Nos.) p) Stairs ( Size 300 mm x 100 mm) (Only figure Based) (12 Nos) q) Plates for office area ( Size 300 mm x 100 mm) (135 Nos) r) Conference Room ( Size 300 mm x 100 mm) 2 No. s) Guest Room (2 No.) t) Committee Room ( 1 No.) u) Command and Control Room ( Size 300 mm x 150 mm) 2 No.
GUIDE MAP
Providing and fixing of signage made of SS outer frame 1200mm x 900mm with one vertical and horizontal braces of SS 304 grade stainless steel 50x50x2mm square tube covered with ACP sheet 3mm thick on back side with written matter / logo of approved colour and language on coloured overlay and lamination, the front side be provided polycarbonate sheet 2mm thick and translite printing of Master Plan duly laminated , the complete board be fixed to stainless steel SS 304 grade 125mm dia pipe 7’ – 0” long legs on both side with 4 nos.SS attachment cleats / clips and the pipes be fixed above plates of SS 10mm thick 0.3m x 0.3m size and 0’ – 6’’ pipe below plate having triangular supports of SS plate 10mm (0.15m x 0.10) on all four sides at lower portion (hanging down below plate), both posts embedded in PCC 1:2:4 blocks of size 2’x2’x2’-6” in pit and fixed with 4 nos. stainless steel nut and bolts of size 2’ long 16mm dia and top of vertical pipe be closed with a semi spherical cap of stainless steel .All the sheets be fixed properly on the SS frames and joint be sealed to make the assembly water proof complete back lit with electrical LED light fitting (electrical point provided within 2 meter of spot of fixing).The whole signage post is to be fabricated as per drawing and directions of the Engineer in-Charge.
Description of Work / Item(s)
Amount
Prime Cost Items
Providing rented accomodation for Engineer's staff including electricity, water supply and maintenance (if any) as specified till end of the contract or when no longer required by the Engineer.
Provision of rented Motor Vehicles (4 wheeler SUV). The tendered rate shall include full compensation for supply, delivery, insurance, licensing, running costs such as fuel/driver salary/maintenance.
Ircon International Limited (BID ID -830778)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Ircon International Limited (BID ID -830778)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Ircon International Limited (BID ID -830778)
COMT CONSTRUCTIONS PRIVATE LIMITED (BID ID -831363)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Ircon International Limited (BID ID -830778)
Dineshchandra R Agrawal Infracon Pvt. Ltd. (BID ID -831282)
Ircon International Limited (BID ID -830778)
Ircon International Limited (BID ID -830778)
COMT CONSTRUCTIONS PRIVATE LIMITED (BID ID -831363)
COMT CONSTRUCTIONS PRIVATE LIMITED (BID ID -831363)
Ircon International Limited (BID ID -830778)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Part-1-Technical-Bid.pdf
Tender Documents • 4.77 MB
BOQ_248150.xls
BOQ • 2.17 MB
Pavement-PHE-Electrical-Tender-Drawings.pdf
Additional Documents • 7.86 MB
Structural-Tender-Drawings.pdf
Additional Documents • 25.99 MB
ARCH-Tender-Drawings.pdf
Additional Documents • 27.73 MB
Furniture-Tender-Drawings.pdf
Additional Documents • 3.83 MB
Tenderdocument.pdf
Tender Documents • 7.86 MB
BOQ.xls
BOQ • 2.19 MB
Tenderdocument_2.pdf
Tender Documents • 4.77 MB
Tenderdocument_3.pdf
Tender Documents • 27.73 MB
Tenderdocument_4.pdf
Tender Documents • 25.99 MB
Tenderdocument_5.pdf
Tender Documents • 3.83 MB
Download all tender documents and submit your bid