Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
6 Dec 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE, PWD(Roads), Assam, Chandmari, Ghy-3
CE, PWD(Roads), Assam, Chandmari, Ghy-3
MMNPPNA_2025_26_07 (1) Improvement of Vivekananda Road Lane No.27 with RCC Cover Drain both side, starting from Dinendra Purkayastha house to RCC Bridge.. (2) Improvement of New Mahadev Lane starting from Chirukandi Road (Near Bishfuti Bridge) at Tap
2025_PWD_48969_2
CE/DEV/TB/120/2025-26/29 Dtd- 27.11.2025
Open Tender
Civil Works – Roads
Item Rate
270 days
Silchar
Please refer Tender Documents
5 documents required · 5 mandatory
₹5,220
₹5.2 L
Yes
CE, PWD(Roads), Assam, Chandmari, Ghy-3
1 Dec 2025
1 Dec 2025
6 Dec 2025
1 Dec 2025
6 Dec 2025
1 Dec 2025
1 Dec 2025 - 3 Dec 2025
3 Dec 2025
(i)Improvement of Vivekananda Road Lane No.27 with RCC Cover Drain both side, starting from Dinendra Purkayastha house to RCC Bridge Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (B)(b) In area of thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(I) Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401,II) For Grading II Material
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing as per drawing Clause 1701 and Annexure 1700.1
Utility shifting
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I. In Ordinary soil (i) Upto 3 m depth
Providing Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A With crushed Stone ( II). PCC Grade M15 Nominal mix 1:2.5:5.
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/ Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing plain/reinforced concrete in Sub Structure complete as per drawings and technical specifications Clause 802, 804,805,806,807, 1202 & 1204. A. With crushed Stone IV R.C.C Grade M20 Nominal mix (1:2:4)
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
(ii) Improvement of New Mahadev Lane starting from Chirukandi Road (Near Bishfuti Bridge) at Tapabannagar Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (A)In area of non thorny jungel.
Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5 m transporting to site spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5.(i) Private Land.
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads transporting to site spreading grading to required slope and compacted to meet requirement of Table 300.2 with upto 1000 m as per Technical Specification Clause 303.1 (i) Private Land
Construction of granular sub-base by providing well graded material spreading in uniforms layers by tractor with grading attachment on prepared surface mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per Technical Specification Clause 401.
Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing rolling with three wheel 80-100 kN static roller in stages to proper grade and camber applying and brooming stone screening/binding materials to fill up the interstices of coarse aggregate watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 . 3) WBM Grading -iii Using stone screening Type-B 11.2 mm for Gr.III (A) By Manual Means
Providing & laying of Interlocking Concrete Block Pavement(M40) having thickness 80mm as per drawing and technical specification clause 1504.Complete including carriage (including Edge block/ Edge restraints)
Construction of H.P culvert NP3 (single barrel)1000.00mm Earthwork in Excavation for foundation of structures up to 3.00 m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backs filling with approved materials
Bedding for Pipe (ii) Type B (First class) bedding.laying (first class) bedding on well compacted sand,moorum or approved granular material as clause 1105(ii) (ii) Granular Materials
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix in levelling course below open foundation of head wall as per drawings and technical specification clause 1109 A. With crushed stone
Providing and laying Reinforced Concrete pipe NP-3 on 1st Class Bedding of granular material in single row as per drawing and technical specification Clause 1106 (B) 1000 mm dia.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203,P.C.C Grade M15,Nominal mix 1:2.5:5 (Hand mixing)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806,807, 1202 ans 1204,P.C.C grade M 15
Construction of RCC Piling Retaining wall Earth work in excavation for structureas as per drawing and technical specification Cl;305.1 , including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials.Ordinary soil(i)Up to 3.00m depth.
Bored cast-in-situ M25 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications nd removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-400 mm)(Manual means)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing concrete for plain/reinforcement concrete in open foundations complete as per drawings and technical specifications clause 802, 803, 1202 & 1203.(B)With Natural Gravel (I) P.C.C. grade M 10 Nominal mix 1:3:6
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification.(B)With Natural Gravel (III) R.C.C. grade M 20 (i) for height upto 5m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Back filling behind abutment, wing wall & return wall complete as per drawings and technical specifications. Clause 1204.3.8 (i) Granular Material
Construction of RCC Toe wall Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil Upto 3.00m depth.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.(B) With natural Gravel (I) P.C.C Grade M 10 Nominal mix 1:3:6
Plain / reinforced cement concrete in substructure complete as per drawings and Technical Specification Clauses 802 ,804 ,805 ,806 ,807 ,1202 ,and 1204 (B) With Natural gravel (III).RCC grade M 20 (1:2:4) (Nominal mix) (i) For height upto 5m.
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT r
einforcement bar(SAI/BISCON/THERMAX or equivalent)) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Construction of Gabion Wall Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801.
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Utility Shifting
Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5 m transporting to site spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5.(i) Private Land.
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads transporting to site spreading grading to required slope and compacted to meet requirement of Table 300.2 with upto 1000 m as per Technical Specification Clause 303.1 (i) Private Land
Construction of granular sub-base by providing well graded material spreading in uniforms layers by tractor with grading attachment on prepared surface mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per Technical Specification Clause 401.
Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing rolling with three wheel 80-100 kN static roller in stages to proper grade and camber applying and brooming stone screening/binding materials to fill up the interstices of coarse aggregate watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 . 3) WBM Grading -iii Using stone screening Type-B 11.2 mm for Gr.III (A) By Manual Means
Providing & laying of Interlocking Concrete Block Pavement(M40) having thickness 80mm as per drawing and technical specification clause 1504.Complete including carriage (including Edge block/ Edge restraints)
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801.
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
(iii)Improvement of Baidik Township, Chincoorie Road Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (A)In area of non thorny jungel.
(iv) Improvement / Construction of RCC Divider with iron Grill from Public School Road to Rangirkhari point Construction of RCC Divider from Public School Road to Rangirkhari point as directed by the Engineer in charge
Providing ,fitting & fixing in position of Ornamental Iron Grill at Road Divider as directed by engineer in charge.
Bored cast-in-situ M25 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications nd removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-400 mm)(Manual means)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing concrete for plain/reinforcement concrete in open foundations complete as per drawings and technical specifications clause 802, 803, 1202 & 1203.(B)With Natural Gravel (I) P.C.C. grade M 10 Nominal mix 1:3:6
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification.(B)With Natural Gravel (III) R.C.C. grade M 20 (i) for height upto 5m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Back filling behind abutment, wing wall & return wall complete as per drawings and technical specifications. Clause 1204.3.8 (i) Granular Material
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
(v)Maa Kali Lane, Ashram Road Construction of RCC Piling Retaining wall Earth work in excavation for structureas as per drawing and technical specification Cl;305.1 , including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials.Ordinary soil(i)Up to 3.00m depth.
Padmini Lane, Ashram Road Bamboo Piling below Box cell under PCC for marshy soil
Construction of Double Cell 2 x 5m x 5 m Box cell Culvert at Padmini Lane Earthwork in excavation for structures as per drawing and technical specifications Clause305.1 including setting out, construction of shoring and bracing, removal of stumpsand other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203 With crushed Stone P.C.C grade M 10 Nominal mix 1:3.6 (Hand mixing)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4) (Hand Mixed)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 RCC Grade M 20 i) For height upto 5 m
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 i For nominal mix 1:2:4 b) Height from 5m to 10M
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11 With Crushed stone
Supplying, fittingandplacingTMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar . (From Primary Producer:TATA/SAIL/EsserSteel/Jindalsteel/Shyamsteel/RINL)in Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/ Shyam steel/ RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Earth Filling (marshy Soil)
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5 m transporting to site spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5.(i) Private Land.
einforcement bar(SAI/BISCON/THERMAX or equivalent)) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Construction of Gabion Wall Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301.
Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801.
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.41 MB
Tendernotice_2.pdf
PDF • 8.33 MB
Tendernotice_3.pdf
PDF • 0.60 MB
BOQ_77713.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .