Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 1 1E KHODAGONGE ROAD KOLKATA 700 010 | KOLKATA | KOLKATA | WEST BENGAL | 700010 | ₹3.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.8 LRejected-Finance 159 KAILASH GHOSH ROAD KOLKATA 700008 | KOLKATA | WEST BENGAL | 700008 | ₹3.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹3.8 LRejected-Finance | ₹3.8 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | COSMOS CONSTRUCTION L1 | POWER INDIA L2 | UTTAM AUTO ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00HT Panel repairing (PART I) | ||||||
| 1.01 | Servicing and overhauling of 400 Amps/500 Amps/630 Amps/1250 Amps, 11 KV/6.6KV/3.3kV VCB/VCU dismantling the rack from the housing , opening the components, necessary cleaning of the components, carbonised portion, changing of rubber gaskets, defective parts, cleaning of all mechanism part and lubricating the mechanism, opening of CT & PTS busbar spoutr adssembly cleaning the same and insulated properly by supply of CTC etc. and refitting all the parts to its origibnal position by making all relevant elcetrical connection, panel wiring etc. for satisfactory & operation. | 4 | Job | 14,340 ₹57,360 | 15,000 ₹60,000 | 14,250 ₹57,000 |
| 1.02 | Modification testing and tit bit wiring of feeder.(2 nos capacitor feeder and 2 nos motor feeder) | 4 | job | 25,160 ₹1.0 L | 25,000 ₹1 L | 27,000 ₹1.1 L |
| 1.03 | Supply and replacement at site of VCB spout for busbar. | 2 | nos | 12,705 ₹25,410 | 13,100 ₹26,200 | 12,650 ₹25,300 |
| 1.04 | Supply and replacement of VCB housing (6-11 KV). | 2 | no | 9,500 ₹19,000 | 10,020 ₹20,040 | 9,455 ₹18,910 |
| 1.05 | Supply and replacement of drive insulator for VCB. | 3 | no | 7,455 ₹22,365 | 7,985 ₹23,955 | 8,000 ₹24,000 |
| 1.06 | Supply and replacement of nut bolt washer, 1.5 mm cable and socket | 1 | job | 5,520 ₹5,520 | 4,500 ₹4,500 | 6,000 ₹6,000 |
| 1.07 | High voltage testing of individual VCB one by one and then HT bus. | 1 | Job | 21,850 ₹21,850 | 23,854 ₹23,854 | 22,000 ₹22,000 |
| 1.08 | Relay setting of feeder and installation and commissioning of feeder with the HT board . | 1 | job | 18,410 ₹18,410 | 18,000 ₹18,000 | 19,600 ₹19,600 |
| 2.00EOT repairing (PART II) | ||||||
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
12 Dec 2025, 2:00 pmClosed
Executive Engineer, MD-III, EM, KMDA
OFFICE OF THE EXECUTIVE ENGINEER MECHANICAL DIVISION-III, E-M SECTOR, KMDA 1, RN TAGORE ROAD, KOLKATA-700076
Overhauling and repairing of 04 nos. VCB feeder fitted at HT board having voltage level 6 KV, 400 A, along with repairing of EOT crane and two nos. dewatering pump located at 30 MGD WTP/Clear water pump house under Dumdum, North Dumdum, South Dumdum
2025_KMDA_947961_1
KMDA/EM/EE/MD-III /NIT-25 of 2025-26 Dated- 12.11.2025
Open Tender
Miscellaneous Works
10 days
Dumdum, North Dumdum, South Dumdum
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹7,500
OFFICE OF THE EXECUTIVE ENGINEER, MD-III
8 Jan 2026
26 Nov 2025
16 Dec 2025
26 Nov 2025
12 Dec 2025
26 Nov 2025
3 Dec 2025
Amount
HT Panel repairing (PART I)
Servicing and overhauling of 400 Amps/500 Amps/630 Amps/1250 Amps, 11 KV/6.6KV/3.3kV VCB/VCU dismantling the rack from the housing , opening the components, necessary cleaning of the components, carbonised portion, changing of rubber gaskets, defective parts, cleaning of all mechanism part and lubricating the mechanism, opening of CT & PTS busbar spoutr adssembly cleaning the same and insulated properly by supply of CTC etc. and refitting all the parts to its origibnal position by making all relevant elcetrical connection, panel wiring etc. for satisfactory & operation.
Modification testing and tit bit wiring of feeder.(2 nos capacitor feeder and 2 nos motor feeder)
Supply and replacement at site of VCB spout for busbar.
Supply and replacement of VCB housing (6-11 KV).
Supply and replacement of drive insulator for VCB.
Supply and replacement of nut bolt washer, 1.5 mm cable and socket
High voltage testing of individual VCB one by one and then HT bus.
Relay setting of feeder and installation and commissioning of feeder with the HT board .
EOT repairing (PART II)
Tit bit servicing and repairing work of 10 TON EOT crane after supply fitting fixing of mechanical interlock,auxiliary contactor, fuse , timer etc. including thorough graesing of all rotating part complete in all respect as per the direction of EIC.
Dewatering pump repairing (PART- III)
Supply and fixing of impeller , shaft bushes , key for 10.5 HP dehydration pump for pump no 1 including repairing and servicing of all mechanical part of the pump as directed by EIC.
Supply and fixing of impeller , shaft bushes , key for 10.5 HP dehydration pump for pump no 2 including repairing of damaged impeller by welding and other allied work of the pump and motor as directed by EIC.
Hiring of two nos dewatering pump on temporary basis to be used for emergency purpose to clear the static water inside the pump house.
POWER INDIA (BID ID -7622334)
UTTAM AUTO ENTERPRISE (BID ID -7604713)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid