Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC SCO 26 SEC 30 KURUKSHETRA 136118 | KURUKSHETRA | HARYANA | 136118 | L1 | Accepted-AOC LOA | |
| 2 | L2₹31.8 L+₹3.9 L (14.1%)Rejected-Finance PLOT NO 729 INDUSTRIAL AREA PHASE 2 | L2 | Rejected-Finance Highest | |
| 3 | L3₹33.9 L+₹6.1 L (21.9%)Rejected-Finance | L3 | Rejected-Finance Highest | |
| 4 | L4₹34.9 L+₹7.0 L (25.2%)Rejected-Finance | L4 | Rejected-Finance Highest |
Tender Value
₹35.4 L
EMD Value
₹70,720
Closing Date
29 Feb 2024, 5:00 pmClosed
ED - Ambala
ED - Ambala
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations under RCS Scheme in Ambala District (Pdg. VRV/VRF Air Conditioning System) (Recall)
2024_HRY_342997_2
20245A0EE1A5 E45C 41DF 9EFC 086210F37E95663BAR
Open Tender
Electrical Works
Works
530 days
Ambala Cantt
Establishment of Civil Enclave at Ambala for Commencement of Flight Operations under RCS Scheme in Ambala District (Pdg. VRV/VRF Air Conditioning System) (Recall)
2 documents required · 2 mandatory
₹5,000
₹70,720
Yes
16 Jul 2024
15 Feb 2024
1 Mar 2024
16 Feb 2024
29 Feb 2024
16 Feb 2024
Amount
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP
[23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.11]EARTHING AND LIGHTENING ARRESTOR 11. Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
EQUIPMENT (High side) Inverter based VRF System Supply, installation testing and commissioning of Air Cooled VRV/VRF units with Rotary /scroll Compressor capable of modulating capacity ,i,e it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating and cooling both.The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. Each ODU should have variable compressors. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping.Note:- Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be )3.2 as per ARI Conditions complete in all respect upto entire satisfaction Engineer in charge of work. The Machine Works on Single Phase Power Supply. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU. Outdoor units, 6HP. Makes: Mitsubishi Electric, Daikin, Samsung,Carrier Midea, LG, O General.
4 WAY CASSETTE INDOOR, Supply, installation testing and commissioning of 2.6 TR indoor units with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, LG, O General.
4 WAY CASSETTE INDOOR, Supply, installation testing and commissioning of 2.0 TR, indoor units with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, LG, O General.
4 WAY CASSETTE INDOOR, Supply, installation testing and commissioning of 1.6 TR, indoor units with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, LG, O General.
ONE WAY CASSETTE INDOOR, Supply, installation testing and commissioning of 1.0 TR, indoor units with evaporator coil, fan and fan motor drain pump drain pan and Grille pannel. The units shall be of following capacities :Makes: Mitsubishi Electric, Daikin, Toshiba, Samsung, LG, O General.
Supply, installation testing and commissioning of Remotes (Cordless), complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work
Supply, installation testing and commissioning of REFNETS complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work
19.05 mm OD (19mm insulation), Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
15.88 mm OD (19mm insulation), Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
12.7 mm OD (13mm insulation) Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
9.52 mm OD (13mm insulation) Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
6.35 mm OD (13mm insulation), Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger complete in all respect upto entire satisfaction Engineer in charge of work. Make: Mandev, Maxflow, Totaline.
Supply, installation testing and commissioning of 32 mm dia Rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation complete in all respect upto entire satisfaction Engineer in charge of work. Make: Supreme, Prince, Kissan.,
Supply, installation testing and commissioning of Control cabling 2 Core 1.0 Sqmm, complete in all respect upto entire satisfaction Engineer in charge of work. Make: Polycab, Havells, RR
SITC of 6sqmm 2 core Copper Armd. Power Cable, loose/ in existing pipe complete in all respect with petty material and necessary connections upto the entire satisfaction of engineer in charge of work. Make Polycab, Havells, RR
Supply and Erection of 120 Sq. mm 3.5 Core Cable Armoured under ground cable ,loose in existing pipe or trenches, complete with necessary connections including all required material to complete the job in all respect up to the entire satisfaction of the Engineer in charge of the work. Make Polycab, Havells, RR
PRINCE AIRCON
SMD SOLUTIONS
modern cooling solution
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .