| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.5 L
EMD Value
₹21,100
Closing Date
10 Jun 2023, 6:00 pmClosed
AGM (E/M), FCI, Regional Office, West Bengal
FCI Regional Office, 6 Royd Street, Kolkata-700016
Repair and Maintenance of Electrical Installation and street lighting systems and improvement of illumination including replacement of damaged fittings by LED fittings at FSD Behrampore
2023_FCI_755784_1
EE/WB/04/2023
Open Tender
Electrical Works
Item Rate
30 days
FCI FSD Behrampore
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹21,100
26 Jun 2023
1 Jun 2023
12 Jun 2023
1 Jun 2023
10 Jun 2023
1 Jun 2023
Amount
Cat (A) -Items to be supply, installation, testing and commissioning
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 40 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3 x 1.5 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Supplying and fixing 5/6 amps switch ISI mark piano type switch on the existing switch box/ cover including connections etc. as required.
Supplying, installation, testing and commissioning of LED flood light fitting 120 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 Protection complete with all accessories etc. (As per NABL Certified ISO/IEC Specifications)
Supply, installation,testing commissioning of 80W Integrated LED Well glass luminaries comprises of die cast canopy,control gear with M.S. CLAMPS and G.I. nut & bolts with washers as required. (As per NABL Certified ISO/IEC Specifications)
Supply, installation,testing commissioning of 40W LED tube light fitting including all accessories i.e., installation of Led tube on wall/truss with round block, screw etc as required. (As per NABL Certified ISO/IEC Specifications)
Supply of LED street light fitting of 45 watts, of Pressure die cast Al. housing complete with all accessories etc. (As per NABL Certified ISO/IEC Specifications)
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
I/T/C of prewired street light fittings complete with all accessories on the existing G.I. pipe bracket on pole /wall including wiring & connections as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 6 way double door
Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single pole
Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required b) Double pole
Cat (B) - Buy Back Items
Less credit for dismantaled old damaged TPN 6 to 40 Amp
Less credit for dismantaled old damaged 5/6Amp piano/round type switch
Less credit for dismantaled old damaged 25 to 45 W LED Fitting
Less credit for dismantaled old damaged 100 to 200 W LED Fitting
Less credit for dismantaled old damaged 20W LED batten Fitting
MS SUJATA ENTERPRISE
M/s. G.M. ENTERPRISE.
Electro Control
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .