| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed SURESH T on 26.03.2022 | |
| 2 | L2₹5.8 L+₹49,546 (9.31%)Rejected-AOC KODUNGALLOOR TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | L2 | Rejected-AOC Agreement executed SURESH T on 26.03.2022, hence 2nd lowest EMD may be released | |
| 3 | Rejected-Technical | - | Rejected-Technical L4 | |
| 4 | Rejected-Technical T C NO 26 1461 1 SL ELECTRICAL WORKS S L TOWER UR 43 UPPALAM ROAD STATUE UPPALAM ROAD THIRUVANANTHAPURAM KERALA 695001 | THIRUVANANTHAPURAM | KERALA | 695001 | - | Rejected-Technical L5 | |
| 5 | Rejected-Technical BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | - | Rejected-Technical L3 |
Tender Value
₹6.4 L
EMD Value
₹16,000
Closing Date
9 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Thiruvananthapuram Corporation 695033
Providing re-electrification in UPS at Kudappanakunnu under City Corporation Thiruvananthapuram.
2022_LSGD_479071_2
EE(C)/TENDER/2021-22 (26)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,300
Yes
₹16,000
Yes
12 Apr 2022
2 Mar 2022
11 Mar 2022
2 Mar 2022
9 Mar 2022
2 Mar 2022
60 days
Amount
90.2.1.1. Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
Single Control light point with 6A, 3 plate ceiling rose -
90.2.1.2. Twin control light point with 3 plate ceiling rose
90.2.1.3. Single control light point with out ceiling rose
90.2.1.4. Single controll seleing fan point with 6 A, 3 plate ceiling rose and with socket typped electronic regulator.
90.2.1.5 Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point
90.2.1.6. Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.8. Independent Plug
90.3.18.1 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.
25 mm dia with HG company fabricated clamps
90.4.8. Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.5.1.4. Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required. Musical bell with bird sound
90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
1200 mm sweep (category B) 5 strar rated.
90.4.3 Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required.
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
90.6.4.12 1.50 sqmm 2 run
90.6.4.13 1.50 sqmm 3 run
90.6.4.14 1.50 sqmm 4 run
90.6.4. 16 1.50 sqmm 6 run
90.6.4. 22 2.50 sqmm 2 run
90.6.4.32 4.00 sqmm 4 run
90.6.4.44 6.00 sqmm 4 run
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
1.27.5. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module (125 x 125 mm)
1.24.4. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp Switch.
1.24.1. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp Switch
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2.8.6. 2.8.6 Supplying and fixing following pre wired TP &N MCB distribution board of seet sheet for 415 Volts on surface /recess complete with loose wire box, terminal connectorers for all incoming and outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper bus bar neutral link earth bar detachable gland plates interconnections powder painted including earthing etc. as required (but without MCB/RCCB/Isolator) 6 way (4+8) Double door
(2.4.4) Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB distribution board 415 volts,on surface/recess, complete with tinned copper bus bar, common neutral link, earth bar, din barfor interconnections, powder painted including earthing etc. as required. (but without MCB/RCCB/Isolator) 4 way (4+12 ) double door
2.3.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 16 way, Double door
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2. Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.2 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
(MR1183) 20W 2000 lumen LED, IP65 street light fittings with Aluminium housing stove enameled CRCA sheet, Steel reflector cover, acrylic cover complete with THD <10%, power factor>0.98, ROH complaint duly wired up for use on 230 V ac supply
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised alumi8nium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheather 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
Supply and fixing brass batten /angle holder including connection with 10 W LED bulb as required
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required.
2.00 mm copper conductor (6 SWG)
3.15 mm copper conductor (14 SWG)
Supply , conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 305 mm sweep 1400rpm Heavy Duty exaust fan working on 230V AC
5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and providing the following size of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
300 X 300 X 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos. of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
2x25x3 mm GI Strip
Supply and providing earth lead from the test joint to the earth electrode using following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 GI strip
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excating trench of suitable size and refilling etc. as required.(In ordinary soil)
3.15 mm copper conductor (10 SWG)
Dahua/epplus/Panasonic 16 Channel Digital video recorder full hd 1080 x 1920 16 channel HD Camera inputs 1 SATA. 2 USB IR 145 (Gigabyte) HDMI/VGA simultaneous vedeo output support Multi brand camera CMS softwae support and moble.
Dahua/epplus/Panasonic IR built camera 2 MP PRO HD + SERIES 2 MP Pro HD + image sensor Low light performance Day/light AWB, AGC BLC ONVIF Version 2.4 complaint ir range of 30 m 2D/3D +DNR, IP 66
4 TB Seagate/Toshiba/WD Video survellance hard disc
SMPS power adapters for 8 camera units
6 U Rack with PDU hardware kit and cooling fan
UPS 600 VA for surveillance system
Laying charges for Fenolex/Chetan3 +1 CCTV cable with ISI granted PVC pipe accessories and conduit, cable etc.
32 " LED TV Samsung/LG (Normal) (formain view)
Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubbrised form sleeve 10mm thick, brazing leak testing etc,(for extending length of pipe beyond standard length supplied with the unit)
16mm (5/8) dia 22 gauge soft drawn copper pipe insulated using 10 mm thick rubberised form sleeve
od 73361/2020-21 Supply and coveyance installation testing and connussioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating o 230V single phase AC supply, RA 10A/R32 non CFC refigerant capable of performing functions like Cooling Dehumidifying air circulating filtering etc of following capacity, microprocessor control with cordless remote control etc. 2.0 TR 5 Strar single phase invertor type split type AC unit with company fabricated frame and comperhensive maintanance comtract upto the end of 36 months from date of commissioning including periodical services, gas topping etc. Complete (make- Blue star/Carrier/Mitsushi/Hittachi/LG/Daikin/Thoshiba)
Supplyin and fixing of 20 mm outer dia 10 Kgf/cm2 PVC conduit and its accessories as drain water pipe for AC
Supply of 3.45 KVA voltage Stebilizer suitable for 2.0 TE single phase split type AC unit with voltage range of 170-270V having built in thermal overload protection; Low & High Voltage cut-off and Low & High Voltage cut off Protection -- Protest connected equipment from potentially dangerous voltages (V guard VG 500 or equilant)
Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubbrised form sleeve 10mm thick, brazing leak testing etc, 3/8 inch (9.252mm) and 5/8 inch (15.875 mm) 22 gauage.
Supply and providing brackets
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings 63A
Supply and fixing the following accessories in the existing meter board and giving connections etc.
63A, 415 V, DIN type fuse base.
63A 415 V Bakelite fuse fitting
100 A, 415V, 2 way neutral link mounted on DMC/SMC base.
Amount to be remitted in KSEB for shifting meter board and additional cash deposit if any required (The actual amount remitted will be reimbursed based on actuals)
S RADHAKUMAR
STEPHEN MOSES
Ajayakumar.D
SL ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_687890.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .