Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹27.9 L+₹86,232 (3.18%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹33.6 L+₹6.5 L (23.9%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹33.8 L+₹6.7 L (24.7%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹34.0 L+₹6.9 L (25.4%)Rejected-Finance FLAT NO S 4 DOOR NO 10 4 107 17 SRINIVASA TOWERS SRI RAMNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹47.1 L
EMD Value
₹94,300
Closing Date
24 Apr 2024, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIRS/REPLACEMENT OF UNSV SPARES OF 11KV VCBs AND ALLIED WORKS AT NEW DOCKYARD AND DRY DOCK MARINE SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2024_MES_647958_1
8020/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹94,300
Yes
3 Jul 2024
27 Mar 2024
26 Apr 2024
27 Mar 2024
24 Apr 2024
10 Apr 2024
Amount
Attending day to day complaints and call on repair of HT Switchgear Vacuum Circuit breaker of capacity 630A to 1250A Schneider make with one Engineer , one electrician and one helper for all days including Holidays & Sundays for opening of covers, checking for any uncertainty and refixing the same to original position, re-connection of all existing cables, extended bus bars, after rectification & testing , closing the complaint by re-energising the feeder complete all as specified and as directed. Note: Replacement of defective parts shall be measured and paid separately
Maintenance, servicing, cleaning of vacuum circuit breaker unit of 11 KV VCB panel of capacity 630 Amps to 1250 Amps, taking out from panel, cleaning of all parts with CTC and clean cloth, removal of carbon deposited inside the moving contacts, greasing of all moving parts of the VCB, checking of complete operating mechanism for proper functioning, reporting for any defective parts, complete all as specified and as directed. Note: Replacement of defective parts of the VCB shall be measured and paid separatel.
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIJ00098-01
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- MVIJ00056-01
Supply and fix single (Read-Blue) phase busbar spout suitable for 630 Amps to 1250 Amps VCB complete all as specified and as directed. Make :- Schneider only Model No MEP-39-32185
Supply and fix single (Y) phase busbar spout for 630 Amps to 1250 Amps VCB complete all as specified and as directed. Make :- Schneider only Model No MEP-39-32186
Supply and fix CT Spout suitable for VCB 630 Amps to 1250 Amps complete all as specified and as directed. Make :- Schneider onl Model No MEP-39-32187
Supply & fix closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and as directed.. Make- Schneider, Part No- ECO39SN134900FN
Supply and fix tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete including dismantling taking down unserviceable one complete all as specified and as directed.. Make- :-Schneider, Part No- ECO39SN134100FN
Supply and fix including dismantling taking out unserviceable Service /Test Position Limit Switch 1NO+1NC For 630 Amps to 1250 Amps 11 KV VCB complete all as specified and directed. Make :-Schneider only, Part No- ESW-B-AAA00-001
Supply and fix including dismantling taking out unserviceable Breaker Wheel - CAST IRON, For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make :- Schneider only, Part No-MVIA00025-01 complete all as specified and as directed.
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No-MVIJOO157-02
Supply and fix incl dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 630 Amps to 1250 Amps all as specified and directed. Make-Schneider VSLVG3002-01 or DRCVG2002-01 as per existing
Supply and fix including dismantling taking out unserviceable busbar supporting insulator For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only , Part No- MEP-39-A0147901
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor for 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- ERC-A-A00DC-001
Supply and fix Drive Beam suitable for 11 KV VCB 630 Amps to 1250 Amps complete all as specified and directed. Make :- Schneider only Model No MSM3950118600FN
Supply and fix including dismantling taking out unserviceable Isolating Contact For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider only, Part No- MVIK00190-01
Supply and fix Epoxy Body suitable for 11 KV VCB 630 Amps to 1250 Amps complete all as specified and as directed. Make :- Schneider only Model No MEP3953022000FN-22
Supply and fix Shutter assembly for busbar / circuit spout suitable for 11 KV VCB 630 Amps to 1250 Amps complete all as specified and as directed. Make :- Schneider only Model No SPP0009-04
Supply and fix space heater, 230V, 100 watt inside cable chamber including necessary connection, testing complete all as specified and as directed. Make- Schneider, Part No-EHT-A-AA 000-001
Supply and fix including dismantling taking out unserviceable thermostat for space heater For 630 Amps to 1250 Amps Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- ETH-E-B000-001
Supply and fix including dismantling taking out unserviceable resin cast CT dual core of ratio 100-50/5A-5A/15VA core 1 metering, core 2 protection of breaking capacity 31.5KA with dimension 220x110x230 mm and hole to hole 110 mm for 800 to 1250 A Schneider make 11 KV VCB complete all as specified and as directed. Make : Kappa/Esun/ Pragati/AE/ SCHENIDER/ Plastofab Note : Contractor should visit the site for brackets size to mounting the CTs in 11 KV VCBs.
All as per item No 22.00 above, but 400-200/5A-5A/15VA 5P10
All as per item No 22.00 above but 600-300/5A-5A/15VA 5P10
M&L for THERMOGRAPHIC TESTING of 11kV switch Boards with IMAGE INFRARED CAMERA to detect Hot spots, to avoid electrical failures and increase safety for all current-carrying devices. Visual and Mechanical Inspection to be done when load is applied to the system. Use & follow appropriate caution, safety devices, and personal protective equipment. Provide a report which includes the following: 1. Description of equipment tested. 2. Discrepancies if any.(HOT Spots). 3. Identify load conditions at time of inspection. 4. Provide photographs and/or thermo grams.
M&L for painting of outer surface of multiple section of complete VCB panel 11 KV size upto 2m x 1.8 x 0.8 in one substation using one coat of synthetic zinc paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears all as specified and directed.
Decarburizing/Buffering of copper Busbar complete from 11kV HT Bus bar chamber of each VCB panel including connecting Busbar from CT to main Busbar & spout. Servicing of support insulator by clean cloth and hot air blower/ vacuum cleaner, applying Backtol Red solution to the bus bar insulator , checking for any loose contact, refixing of all nuts & bolts by Stainless steel , refixing all covers ,replacement of defective parts, busbar sleeve and ensure proper decarburizing up to proper megger value , checking all the connections all as specified and directed.
Supply and fixing of Complete PT set, including dismantling taking out complete unserviceable drawout type PT trolly set , PT of 100 VA, dual core of ratio 11KV/root3/110V/root3/100VA , Insulation class F, core 1 metering, core 2 protection complete all as specified and as directed. Make : Kappa/Esun/ Pragati/AE/SCHENIDER/ Plastofab Note : Contractor should visit the site for brackets size to mounting the PTs in 11 KV VCBs.
Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider/AudioVision/ANNAND/UNITY/ BUSSMANN
M&L for maintenence/servicing of PT unit 11Kv / 110V by disconneting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of busbar connections, resin cast PTs using hot blower, CTC solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Supply and fix PT Spout suitable for VCB Panel 800 to 2500 Amps , along with connected busbars/cables complete all as specified and as directed. Make : Kappa/Esun/ Pragati/AE/SCHENIDER/ Plastofab
MVV Prasad
MSN ENGINEERING WORKS
SD TECH
M.V.K.ENTERPRISES
M/s SS Engineering Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .