Tender Value
₹2.7 Cr
EMD Value
₹3.1 L
Closing Date
2 Aug 2021, 11:00 amClosed
EE
Jal Shakti Division Dehra
Under Jal Jeevan Mission
2021_HPIPH_49977_1
DHR-KNG02-728
Open Tender
Civil Works
Item Rate
730 days
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,500
EE Dehra
₹3.1 L
17 Nov 2021
17 Jul 2021
2 Aug 2021
17 Jul 2021
2 Aug 2021
17 Jul 2021
Amount
RCC Dyke/ Key :-Designing , Surveying and Construction ,testing and commissioning of RCC Key/ Dyke specified in the basic design data near to Existing Check Dam at Headworks of LWSS Khundian and Tip Thalakan including Providing and laying RCC Design mix Concrete M -20 & 25 in Bed / Walls and Apron back side as per soil bearing capacity with the approval of structural drawing from competent authority prior to execution complete within all leads and lifts. complete in all respects to the entire satisfaction of the Engineer-in-charge. The contractor shall provide 6 sets of approved drawing and design with one soft copy to the department. ( Data Sheet No.1 Vol-II)
Designing and Construction ,testing and commissioning of waterTreatment plant .310 MLD SSF :- the scope of work includes the construction of 0.310 WTP capacity water treatment plant capable to treat the raw water of the quality specified in the basic design data to produce clear water as per the requirements of CPHEEO manual on water supply and treatment and as specified in basic design data. The water treatment plant shall include the construction of raw water tank, Sedimentation tank, alum solution/mixing tanks and dosing arrangement,slow sand filters bed complete with scouring arrangement,clear water tank, complete disinfection arrangement with bleaching powder based Chlorination ,(toilet ), requirement,piping,valves mechanical, interconnecting paths, site development upto a minimum of 3m from edge of battery limit of plant, retaining and breast walls and fencing.The firm shall submit the detailed hydraulic and structural design and drawings( 6copies) for each component oftreatmentplant which shall be approved by the department before the work is started. The design/drawingsof the mechnical/ electrical equipment etc. along with manufacturersspecificattion/design also be submitted for approval by the department.Onthe completion of allcivil, mechnical and electrical works the contractor shall test run the plant for one week beforehanding over the same to the department at the cost of the contractor.However,electrical chareges shall be borne by the department. .During this period the daily testing of raw water and treated water samples shall be done. Complete record of the test results and the flow measurements shall be kept during this period. If the performance of various units of thetreatment plant is as specified in CPHEEO manual, the dfplant shall be formally taken over by the department,otherwise the contractor shall make necessary change / repairs to improve theefficiency of the unit/plant.The contractor/ firm shall run and maintain the plant for one month afterhandingover the plant to the department. During this period the firm shall depute at least onetrainedperison to train the departmental persons in operating, maintaining the plant and regulartesting of the raw water and treated. ( Data Sheet No.2 Vol.II)
Pump House:- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) Construction of RCC framed pump house 5 mtrs height , including Gantry system of Pump Houses at following Locations including all allied Civil Works, internal & external Electrical work wiring, Sanitay work, excavation in foundation in all kinds of soils, c/o Toilets, c/o Septic Tanks of capacity for required users, including cost of site development required as per site condition,internal and, external landscaping, dewatering including P/F3/5 Tonne chain pulley / Gantry alongwith MS rail along longitudinal wall of approved ISI make electrically operated alongwith all allied accessories and painting with asian apex ultima with priming coat and wall putty and fire fighting system complete as directed by engineer in charge. (Ref data sheet No. 2 & 3 for further details.). The contractor shall provide 6 sets of approved drawing with design and one soft copy to the department. ( Data Sheet No.3 Vol.II)
Pump house at Main Stage near headworks 55.50Sqm.
Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) RCC Circular under ground/partial under ground storage reservoirs as per capacity given below at various stages/sites including excavation in foundation in all kinds of soil. including PCC (1:3:6) in foundation and M:30 design mix in bottom slab/raft ,walls and beams. And RCC (1:1.5:3) in roof slab/dome with provision of inspection path around the dome with all alied Civil Works such as c/o chamber for valves, refilling and disposing of surplus excavated earth with in all leads and lifts. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole covers with frames of heavy duty with proper locking arrangement, water level indicator. The tanks shall be hydraulically tested for water tightness, All works shall be conforming to relevant IS code. The cost of valves, be included in the rates of tanks .complete in all respects to the entire satisfaction of the Engineer-in-charge .The contractor shall provide 6 sets of approved drawing and design to the department including cost of site development required as per site conditions. ( Data Sheet No.4 Vol.II)
C/O Main Tank at Tip of 55000 Litres Capacity
Sector Reserviors:- Designing, Constructing, Testing & Commissioning (to be approved by the competent authority) RCC Circular under ground/partial under ground storage reservoirs as per capacity given below at various stages/sites including excavation in foundation in all kinds of soil. including PCC (1:3:6) in foundation and M:30 design mix in bottom slab/raft ,walls and beams. And RCC (1:1.5:3) in roof slab/dome with provision of inspection path around the dome with all alied Civil Works such as c/o chamber for valves, refilling and disposing of surplus excavated earth with in all leads and lifts. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipe with bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as MS ladders inside and outside, CI cowl type ventilator, SFRC manhole covers with frames of heavy duty with proper locking arrangement, water level indicator. The tanks shall be hydraulically tested for water tightness, All works shall be conforming to relevant IS code. The cost of valves,bulk meter/ flow meter shall be included in the rates of tanks .complete in all respects to the entire satisfaction of the Engineer-in-charge .The contractor shall provide 6 sets of approved drawing and design to the department including cost of site development required as per site conditions. ( Data Sheet No. 5 Vol-II)
Sector Storage Tank of 30000Ltr Capacity at Dolla Jhalot
Sector Storage Tank of 25,000 Ltr CapacityTihri Near School
PUMPING MACHINERY CENTRIFUGAL:- Supply ,Installation ,Testing & Commissioning of star rated enrgy efficient horizontal spindle, horizontal/ radial split casing/end suctions (back pull out arrangement)single/double/multistage centrifugal pump suitable for operation, in parallel of recommended make such as Mather and platt/KSB/Kirloskar/Jyoti /Beaconweir BS&BE confirming to BIS-1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting clear water for under mentioned characteristics with bronze/Bronze with 2.5% Nickel impellers, dia of 405mm priming funnels, casing ring and shaft sleeves of bronze/ steel, shaft of SS:410/AIS 1431 Chrom in plated with cast iron casing coupled directly through a flexible coupling on a Common MS base plate to squirrel cage screen protected drip proof induction motor/TEFC/CACA of standard make such as Kirloskar/BHEL/ Crompton/NGEF/GEC/Siemens/ Jyoti/Area Brown Boven/ABB/CGL and suitable for operation on 11 KV HT, 50 cycles/second 3 phase AC electric supply. The power of electric motor/motors should be at least (+) 10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-) 15% of the duty point head. The motor/motors should be as per IS: 325-1978 with upto date amendments read with IS:900-1972. The starting current of the motor shall be limited to not more than 4.5 to 5 times of full load current.
It should include cost of bearing nuts, bolts and painting etc and should meet the following requirement (as per data sheet No. 13) including Pump sets (working + standby), All electrical equipments such as Starter, ICTP switches, MCB, Bush bar chamber, MCB, Panel board indicating lamps, Ammeter, Voltmeter, Hour run meter should be of electronic type , incoming and outgoing water proof cable for panel board, Double loop earthing, copper cable pressure gauge, capacitor, common header, sluice valve, NRV including erection and testing complete necessary piping for suction and common header and control valves alongwith electrical works including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores/ site, stacking, etc. including specials and wastage etc.; complete as per Tender Specifications and instruction of Engineer in charge. The HP are indicative.Since the re-survey and re-design of proposal/scheme is to be carried out by the lowest bidder, the design/drawings so approved by the competent authority after finalisation of design and drawings,any variation in HP and other accessories etc.The rate shall be worked out on prorata basis after approval of the competent authority and payment will be made accordingly. ( Data Sheet No. 7 Vol-II)
Stage 1st - 4.93 LPS with Head of 477.46 mtr ( 2 Nos. Set i/e 1 No. Working & 1 No Stand Bye )
Rising Mains (Data Sheet No. 6 Vol-II) Excavation in foundation, trenches (for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts Excluding restoration metalled surfaces to its original condition( Will be paid Separately) & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge.
Providing , laying, jointing & testing of bevelled ended MSERW pipe with circumfrential butt welded joints 90% & 10% Flanged wherever required by electrical arc welding ( welding thickness shall be equal to pipe wall thickness) and testing of GMSERW pipe of following dia meters conforming to IS 3183-2012(Part-II), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and fabrication of reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe shall also include welding of flanged joints of duly welded every sixth pipe in three layers (one inner two outer) and all operations such as cutting, welding, jointing, fabrication of bends, tees, making bevelled pipe ends suitable for butt welding , lowering & laying in excavated trenches to ensure required level complete in all respects to the best satisfaction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately) . .The fabricated bends should have three or four cuts having of redius not less then 5 times of dia metrs of pipe. The welding electrodes shall be as per IS 814 of Advani, Oerlikon/L&T of ISI make. The damaged portion of pipe if damaged during laying/jointing,operation of pipe all other special made for the parent tube shall be provided with anticrossibe treatnent or applying the coat of anticrossibe bitumen paint over coat as per AWWA specification C-203-1978. The rate also include entire carriage of material, flushing cleaning & testing pipe D.P.Test of but welded joint complete in all respect & best satisfaction & direction of Engineer in charge.
Main Stage: Pump house - to Tip Tank MSERW Pipe L210 or A 4.80mm WT. dia = 80mm
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) with plain end MSERW pipe in three layers (one inner and two outer) with pipes at both ends to make the joint leak proof (The cost of providing and laying of GMSERW pipes and butt welded joint to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satisfaction of Engineer in Charge with in all leads and lifts.
Table - 17 80mm dia.
Table - 28 80mm dia.
Table - 34 80mm dia.
GRAVITY MAIN& DISTRIBUTION SYSTEM:- Excavation in foundations and trenches (for pipes and pits) upto all depths etc. in all kinds of soil such as pick work, jumper work and saturated soil including bailing or pumping out of water, chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning he usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts Excluding restoration of unmetaled/ mattelled surfaces to its original condition ( will be paid separately) and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of Engineer-in-charge. ( Data Sheet No.8 Vol-II)
Laying,jointing & testing of screwed and socketted Galvanised Mild steel tube of approved make or of approved rate contract of DGS & D/HP Government conforming to BIS 1239-2004 ( with upto date ammendements ) of following diameter and class including all specials and fittings as required complete as per actual site condition with in all leads and lifts as per the direction and to the entire satisfaction of Engineer-in Charge. Negative tolerance in thickness and mass/weight will not be accepted.The pipe shall be factory galvanized as per IS: 4736-1986 (with up to date ammendements) with zink coating not less than 400 gms/sqm. ( Earth work in trenches to be measured and paid separately )After getting the design approved from competent authority, If there will be any change in the class and thickness of pipe, the cost of the same will be paid on pro-rata basis.
50 mm dia L.C. S/S
32 mm dia L.C. S/S
40 mm dia L.C. S/S
Laying, jointing and testing in trenches of GMS pipe butt welded 90% joints butt welded & 10% Flanged joints pipes including cost of flanged bends of all degrees conforming to IS 1239- 2004 (Medium Class) with upto date ammendements ) as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube.The butt welded joints as per table below duly welded in three layers (one inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes confirming to BIS 1364 (with upto date ammendments).The laying of pipe shall include all operation such as cutting, welding, jointing, providing & fixing of fabrication of bends, tees, etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. Negative tolerance in thickness and mass/weight will not be accepted.The pipe shall be factory galvanized as per IS: 4736-1986 (with up to date ammendements) with zink coating not less than 400 gms/sqm. (earth work in trenches to be measured and paid separately )
80mm dia M.C P/E
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments) with plain end GSERW pipe in three layers (one inner and two outer) with pipes at both ends to make the joint leak proof (The cost of providing and laying of GMSERW pipes and butt welded joint to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satisfaction of Engineer in Charge with in all leads and lifts.
MS Flange 80mm Dia. Table 17
SS RANA CONSTRUCTION PRIVATE LIMITED
SEWA SINGH
KAILASH DEWAN
Ravinder Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .