| 1 | L1₹1.2 CrAdmitted-Finance NAGPADA MUMBAI 10TH LANE KAMATHIPURA S P ROAD TELANG BLDG NO 23 ROOM NO 5 10TH LANE MUMBAI 400008 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹20.6 L (16.5%)Admitted-Finance | ₹1.5 Cr+₹20.6 L (16.5%) | L2 | Admitted-Finance |
| 3 | L3₹1.5 Cr+₹22.9 L (18.4%)Admitted-Finance | ₹1.5 Cr+₹22.9 L (18.4%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Techno-comercially Rejected |
| 5 | Rejected-Technical | - | - | Rejected-Technical Techno-comercially Rejected |
| Sl No | Description | Qty | Unit | RCK Electrical Enterprises L2 | ultravolt electricals L3 | SHREE SHIV ELECTRICAL L1 |
|---|---|---|---|---|---|---|
| 1.00Services-HT/LT Panel,Transformer, Busduct | ||||||
| 1.01 | Dielectric test of oil sample | 80 | Nos | 20,000 ₹23,600 Lowest | 40,000 ₹47,200 | 1,00,400 ₹1,18,472 |
| 1.02 | Filtration of oil | 1,00,000 | Liter | 15,00,000 ₹17,70,000 Lowest | 16,00,000 ₹18,88,000 | 15,00,000 ₹17,70,000 Lowest |
| 1.03 | Earth resistance test of Earthing Pits | 200 | Nos | 1,00,000 ₹1,18,000 | 50,000 ₹59,000 Lowest | 96,800 ₹1,14,224 |
| 1.04 | Annual Preventive maintenance of HT/LT Circuit Breakers (with switchgear like relay, meters etc.) | 542 | Nos | 56,91,000 ₹67,15,380 | 37,94,000 ₹44,76,920 | 27,64,200 ₹32,61,756 Lowest |
| 1.05 | Annual Preventive Maintenance of HT transformers. | 54 | Nos. | 6,37,200 ₹7,51,896 | 6,48,000 ₹7,64,640 | 4,32,000 ₹5,09,760 Lowest |
| 1.06 | Cleaning, tightening and visual inspection of LT Busduct. | 20 | Nos. | 30,000 ₹35,400 Lowest | 1,10,000 ₹1,29,800 | 80,000 ₹94,400 |
| 1.07 | Rate for attending breakdowns(excluding spares) | 30 | Nos. | 1,35,000 ₹1,59,300 | 75,000 ₹88,500 Lowest | 1,35,000 ₹1,59,300 |
| 1.08 | Supply and Installation of heat shrinkable HT termination Boot. | 10 | Set | 24,000 ₹28,320 Lowest | 35,000 ₹41,300 | 25,000 ₹29,500 |
| 1.09 | HV test of VCB | 150 | Nos. | 75,000 ₹88,500 Lowest | 3,00,000 ₹3,54,000 | 1,95,000 ₹2,30,100 |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
15 Apr 2024, 12:00 pmClosed
Mr. Ramesh Mourya,DGM
6th Floor, Outsourcing Department, Service Block, Mazagon Dock Shipbuilders Limited, Mumbai-400010
Biennial Rate Contract for Preventive and Breakdown Maintenance of HT LT Panels and Transformers in MDL Yards for 2024 and 2026
2024_MDL_94617_1
6000001604
Open Tender
Miscellaneous Services
Fixed-rate
MDL, Mumbai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3 L
Yes
4 Jul 2024
22 Mar 2024
15 Apr 2024
22 Mar 2024
15 Apr 2024
22 Mar 2024
Services-HT/LT Panel,Transformer, Busduct
Dielectric test of oil sample
Filtration of oil
Earth resistance test of Earthing Pits
Annual Preventive maintenance of HT/LT Circuit Breakers (with switchgear like relay, meters etc.)
Annual Preventive Maintenance of HT transformers.
Cleaning, tightening and visual inspection of LT Busduct.
Rate for attending breakdowns(excluding spares)
Supply and Installation of heat shrinkable HT termination Boot.
HV test of VCB
Attend. minor oil leakage from Xmer, PT
Annual PM of Servo Stabilizer
Attend. major oil leakage from Xmer, PT
rewinding of PT
Inspection of HT installation by Electrical Inspector
Bus support insulators (11kv/440v)
Spring charging motor 220V DC/AC reputed make
110V,DC shunt trip coil reputed make
48V,DC shunt trip coil reputed make
Spring charging motor(230V,AC) reputed make
H.T Heat Shrink Tape Reputed Make
Indication lamps for panels
Half Yearly PM Transformers
Half Yearly PM of HT CB
Break down maint. Of 800/1600A/2000A/3200A LT ACB
Break down maint. of 11KV HT VCB
Transformer break maintenance from 500kva to 2500 kva
Internal Painting Of HT Switchboard
OFF delay timer 0-60sec for APFC Panel
Capacitor duty contactor for 25kVAR with side add on block ( 1NO+ 1 NOC) similar to M/s Schneider make
Capacitor duty contactor for 60kVAR with side add on block ( 1NO+ 1 NOC) similar to M/s Schneider make
Multi functional meter similar to EM6400NG with Class accuracy Class 1.0, RS485 port of M/s Schneider make
48V,DC/110V,DC/230V,AC LED indication lamp(green/red/Yellow/amber)
48V,DC/110V,DC/230V, AC LED indication
Digital Volt meter AC(48 X96/96X96)
Digital Volt meter DC (48 X96/96X96)
Digital Ammeter AC(48 X96/96X96)
Digital Ammeter DC(48 X96/96X96)
CAG14 current relay with tuned circuits adjustable setting 10-40% with %A CTs
Ring Type CT for APFC panel
11KV PT Fuse
Supply Of APFC controllar 8/12/14/16 stage Make: L&T/Schnieder/seimens
Neoprene Rubber Gasket for HT/LT panels
High Voltage Epoxy / antitracking spray
Overhauling of transformer in factory upto 500kVA
Overhauling of transformer in factory 500kVA to 1000kVA
Overhauling of transformer in factory 1000kVA to 1600 kVA
Overhauling of transformer in factory 1600kVA to 25000 kVA
Testing and Recalibration of over current, earth fault, under voltage and other protective relays of English Electric make -type-CDG-31/CDG-61/CDG-36/CDAG-31/CDAG-53,/ numeric relay of M/s Ashida make/DPX/Micom P127 rlays installed in HT panels/LT panels.
Supply of Transformer OIL
Supply of Transformer Oil
DGA test of transformer oil at any NABL accredited lab including sample collection from site and submission of test report
Physical properties test of transformer oil at any NABL accredited lab including sample collection from site and submission test report
Space heater (100/200W) plate type reputed make
Thermostats of Reputed make
Supply of Spares for P&O SUBSTATION - OLD Biecco Lawrie Panel PDB
Resin Cast Current Transformer 200/5-5 A, Core 1: 20VA; 5P10, Core 2: 20 VA; 0.5, S.T.C. :13.1 KA for 2 sec. Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer 100/5-5, Core 1: 20VA; 5P10, Core 2: 20 VA; 0.5 S.T.C. : 13.1 KA for 1 s Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer 300/5-5, Core 1: 20VA; 5P10,Core 2: 20 VA; 0.5 S.T.C. :13.1 KA for 3 s Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer 400/5-5, Core 1: 20VA; 5P10, Core 2: 20 VA; 0.5 S.T.C. :13.1 KA for 2 s Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Potential Transformer, 11 KV/110 V, 3 ph 100 VA / phase Make : Biecco Laurie
Epoxy Spout Insulators (male) with CC Parts Retrofitted trolley; C.B. Rating : 800A, SC rating 25 KA. Make : Areva
Porcelain Spout insulators (female) with CC parts(fitted on panel), CB rating 800A, 25 KA. Make : Biecco Laurie
PT Bushings (male)
PT Bushings (female)
Epoxy Spout Insulators (male) without CC Parts Retrofitted trolley; C.B. Rating : 800A, SC rating 25 KA. Make : Areva
Spares for P&O SS (new BL panel) mod-AXC
Resin Cast Current Transformer; Bar Type 500/5 Amps 15 VA Class 0.5 (core 1 for metering) 15 VA 5P10 (core II for protection) S.C. Level 25 KA Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer; Wound Type CTR 100/5-5 A 15 VA Class 0.5 (Core 1 for metering) 15 VA 5P10 (Core 2 for protection). S.C. Level 25 KA Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer; Wound Type 300-150 /5-5 Amps 15 VA Class 0.5 (core 1 for metering) 15 VA 5P10 (core 2 for protection) S.C. Level 25 KA Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer Wound Type 120-60/5-5 A15 VA Class 1.0 (Core 1 for metering)15 VA 5P10 (Core 2 for protection)S.C. Level 25 KA Make :Biecco Laurie/Pragati/Jyoti
Cast Resin type P.T 11KV/110V; 100 VA/phase; class 1.0 Make : Biecco Laurie
Epoxy Spout Insulators (male) with CC Parts (fitted on trolley) CB rating 800A, 25 KA Make : Biecco Laurie
Epoxy Spout insulators (female) with CC parts (fitted on panel) CB rating 800A, 25 KA Make : Biecco Laurie
PT Bushings (female)
PT Bushings (male)
Safety shutters mechanism set
Epoxy Spout Insulators (female) without CC Parts, CB Rating, 800 A SC rating 25 KA. Make : Areva
Spares for KSS ( Areva pnl) VMX
Resin Cast Current Transformer; Wound Type Core 1: 15 VA CL-1.0 100/5 A metering Core 2: 15 VA Cl- 5P10; 100/5A (Protect)S.C. Level 25 KA Make : Alstom/Pragati/Jyoti
Resin Cast Current Transformer Wound TypeCore 1: 15 VA CL-1.0400/5 A metering Core 2: 15 VA Cl- 5P10; 400/5A (Protect)S.C. Level 25 KA Make: Alstom/Pragati/Jyoti
Resin Cast Potential Transformer 11KV/110 V/110 V100 VA/Ph, CL-0.5 (M), 50 VA/Ph, CL 3P Make :Kappa
Epoxy Spout Insulators (male) with CC Parts (fitted on trolley) CB rating 800A, 25 KA Make: AREVA
Epoxy Spout insulators (female) with CC parts (fitted on panel) CB rating 800A, 25 KA Make: Areva
PT Bushings (male)
PT Bushings (female)
Safety shutters mechanism set
Epoxy Spout Insulators (male) without CC parts, fitted on trolley, CB rating 800 A, 25 kA. Make Areva
Epoxy Spout Insulators (female) without CC parts, fitted on Panel, CB rating 800 A, 25 kA. Make Areva
Spares for SS1 & SS2, SY BL-AXCA
Resin Cast Current Transformer; Wound Type, Core 1: 2.5 VA CL-0.5; 100-50/5 A metering Core 2: 15 VA Cl- 5P10; 100-50/5-5A (Protect) S.T.C. 20 KA for 1 sec Make: Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer, Wound Type, Core 1: 2.5 VA CL-.5; 200/5-5 A metering Core 2: 15 VA Cl- 5P10; 200/5-5A (Protect) S.T.C. 20 KA for 1 sec Make: Biecco Laurie/Pragati/Jyoti
Resin Cast Current Transformer, Wound Type, Core 1: 2.5 VA CL-.5; 300/5-5 A metering Core 2: 15 VA Cl- 5P10; 300/5-5A (Protect) S.T.C. 20 KA for 1 sec Make : Biecco Laurie/Pragati/Jyoti
Resin Cast Potential Transformer 100 VA/Ph, CL-0.5 11KV/110 V/110 V Make : Biecco Laurie
Epoxy Spout Insulators (male) with CC Parts (fitted on trolley) CB rating 800 A, 20KA Make : Biecco Laurie
Epoxy Spout insulators (female) with CC parts (fitted on panel) CB rating 800 A, 20KA Make : Biecco Laurie
PT Bushings (male)
PT Bushings (female)
Safety shutters mechanism set
Epoxy Spout Insulators (male) without CC parts (fitted on trolley) CB rating 800 A, 20 kA.
Epoxy Spout Insulators (female) without CC parts (fitted on panel) CB rating 800 A, 20 kA.
Power Pack Unit
Spares for SS3, SY (CG) 12V26/1250
Resin Cast Current Transformer, Wound Type, Core 1: 20 VA CL-1; 100/1 + 1 A metering Core 2: 20 VA Cl- 5P10;100/1+1 (Protect)S.T.C. 25 KA for 1 sec, MAKE : Crompton Greaves/Pragati/Jyoti
11 KV/ 110 V Resin Cast Potential Transformer100 VA/Ph, CL-1/3 P MAKE: Crompton Greaves
Epoxy Spout Insulators (male) with CC Parts (fitted on trolley) C.B. rating 800 A, 26.3 KA MAKE : Crompton Greaves
Epoxy Spout insulators (female) with CC parts (fitted on panel) C.B. rating 800 A, 26.3 KA MAKE : Crompton Greaves
PT Bushings (male)
PT Bushings (female)
Epoxy Spout Insulators (male) without CC Parts (fitted on trolley) C.B. rating 800 A, 26.3 KA MAKE : Crompton Greaves
Epoxy Spout insulators (female) without CC parts (fitted on panel) C.B. rating 800 A, 26.3 KA MAKE : Crompton Greaves
Spares for Al. yard SS/SSA
Resin Cast Current Transformer 150/5-5 A, Core 1: 10 VA; Class 1.0, Core 2: 10 VA, 5P20, S.C. level 25 kA. Make: Schnieder Electric, Pragati, Jyoti
Resin Cast Potential Transformer, 11 KV/110 V/110V, 3 ph 50 VA, CL: 0.5, Dual Core/Disc 0- type, Make : ECS
Epoxy Spout Insulators (male) with CC parts, Breaker Rating: 800A, 25kA, make: Schnieder.
Epoxy Spout Insulators (female) with CC parts, Breaker Rating: 800A, 25kA, make: Schnieder.
Epoxy Spout Insulators (male) without CC parts, Breaker Rating: 800A, 25kA, make: Schnieder.
Epoxy Spout Insulators (female) without CC parts, Breaker Rating: 800A, 25kA, make: Schnieder.
PT Bushing male
PT Bushing female
HT Panel mounted Fixed type PT set
Spares for Anik Yard & Nhava Yard CG HT Panel
Epoxy Casted Current Transformer, CTR-120/1+1A,STR-25KA/1SEC CORE1- (1A)-15VA/0.5 ,CORE2-(1A)15VA/5P10,CT SEC- ON P1 SIDE MAKE : CGL/SILKANS/SGELECTRICALS
11kv Epoxy Casted Current Transformer,CTR-60-30/1+1A STR-25KA/1SEC,CORE1- (1A)-15VA/1.0,CORE2-(1A)15VA/5P10 CT SEC- ON P2 SIDE,MAKE : CGL/SILKANS/SGELECTRICALS
Epoxy Spout Insulators (male) with CC Parts fitted on trolley.C.B. rating 630 A, 25 KA,MAKE : Crompton Greaves
Epoxy Spout Insulators (female) with CC Parts fitted on panels.C.B. rating 630 A, 25 KA,MAKE : Crompton Greaves
PT Bushings (male)
PT Bushings (female)
Voltage Transformer,Ratio: 11000/110/110VAC , 3PH 3L DRAWOUT TYPE VT,WDG 1:50VA/CL0.5,50VA/3P,CONNECTION-STAR-STAR EPOXY RESIN CAST , FEEDER CONNECTED MAKE: CGL/SILKAAN /KAPPA/ECS VOLTAGE FACTOR-1.2CONT 1.5 FOR 30SEC
Epoxy Spout Insulators (male) without CC Parts fitted on trolley.C.B. rating 630A, 25KA,MAKE : Crompton Greaves
Epoxy Spout Insulators (female) without CC Parts fitted on panels.C.B. rating 630A, 25KA,MAKE : Crompton Greaves
Spares for EY SS HT Panel
Resin Cast Current Transformer CTR 800-400/5A, VA rating 15 VA Class 1.0; 5P10; Make: Biecco Lawrie, Pragati, Jyoti
Resin Cast Current Transformer CTR 200-100/5A, VA rating 15 VA Class 1.0; 5P10; Biecco Lawrie, Make : Biecco Lawrie, Pragati, Jyoti
Resin Cast Current Transformer CTR 400-200/5A, VA rating 15 VA Class 1.0; 5P10; Biecco Lawrie, Make : Biecco Lawrie, Pragati, Jyoti
Epoxy Spout Insulators (male) with CC parts fitted on trolley. CB Rating 1250 A, 25 kA, Make Biecco Lawrie.
Epoxy Spout Insulators (female) with CC parts fitted on Panel. CB Rating 1250 A, 25 kA, Make Biecco Lawrie.
PT Bushings (male)
PT Bushings (female)
Resin Cast PT 11kV/110 V, 100 VA/ph., Class 1.0, Make: Biecco Lawrie
Epoxy Spout Insulators (male) without CC parts fitted on trolley. CB Rating 1250 A, 25 kA, Make Biecco Lawrie.
Epoxy Spout Insulators (female) without CC parts fitted on Panel. CB Rating 1250 A, 25 kA, Make Biecco Lawrie.
Services for Installation. Testing and Energization of Spare transformer (if required)
Install. Test. Energizati. of Spare XMER
Spares for MMP Area SS A, B, C
Epoxy Cast Resin (Wound) current Transformer, CTR 300/5-5 A Core 1: 300/5A, Burden = 15VA Class1 core 2: 300/5 A, Burden=15 VA class 5p10 Make: Kappa/Pragati/Jyoti
Epoxy Cast Resin PT (Drawout) type, Single phase with bult in Primary Fuses of 3.15 A Two Core PT, PTR-11KV/110V Core 1: 11 KV/110 V, 100VA, Class0.5 Core 2: 11KV/110, 50 VA Class3P (open delta)
Epoxy Spout Insulators (male), fitted on trolley, with CC Parts, CB rating 1500 A, make : Siemens
Epoxy Spout Insulators (female), fitted on panel, with CC Parts, CB rating 1500 A, make: Siemens
PT bushings (male)
PT bushings (female)
Epoxy Spout Insulators (male), fitted on trolley, without CC Parts, CB rating 1500 A, make : Siemens
Epoxy Spout Insulators (female), fitted on panel, without CC Parts, CB rating 1500 A, make: Siemens
Epoxy Cast Resin (Wound) current Transformer, CTR 100/5-5 A Core 1: 100/5A, Burden = 15VA Class1 core 2: 100/5 A, Burden=15 VA class 5p10 Make: Kappa/Pragati/Jyoti
Spares for HT Transformer
Supply of Breather for Transformer
Buccholze Relay
Transformer Bushing HT
Transformer Bushing LT
WTI similar to model no.:PC414 with thermal imaging device of Perfect control make or any Reputed make
OTI similar to model no.:PC414 of Perfect control make or any Reputed make
RCK Electrical Enterprises
ultravolt electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .