Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | ₹1.0 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹1.0 Cr+₹3.9 L (3.85%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹1.0 Cr+₹3.9 L (3.85%) | L2 | Rejected-Finance Not Being Lowest Tender |
| 3 | L3₹1.4 Cr+₹43.2 L (42.9%)Rejected-Finance | ₹1.4 Cr+₹43.2 L (42.9%) | L3 | Rejected-Finance Not Being Lowest Tender |
| 4 | L4₹1.4 Cr+₹43.2 L (42.9%)Rejected-Finance | ₹1.4 Cr+₹43.2 L (42.9%) | L4 | Rejected-Finance Not Being Lowest Tender |
| 5 | L5₹1.5 Cr+₹47.4 L (47.0%)Rejected-Finance | ₹1.5 Cr+₹47.4 L (47.0%) | L5 | Rejected-Finance Not Being Lowest Tender |
| Sl No | Description | Qty | Unit | SREE CONSTRUCTIONS L1 | srisampathassociates L6 | M/s.DSRK CONSTRUCTIONS L5 | Pavan Commercial Company L3 | S A R CONSTRUCTIONS L2 | Sri Surya Enterprises L3 | S R CONSTRUCTIONS L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE 'A' PART-I [B/R Works]:
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed. | 373 | SqM | 30 ₹11,190 | 21 ₹7,833 | 25 ₹9,325 | 20 ₹7,460 Lowest | 50 ₹18,650 | 20 ₹7,460 Lowest | 45 ₹16,785 |
| 2.00 | M & L for coloured Glazed ceramic tiles of size 300x600x7mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed. | 322 | SqM | 900 ₹2,89,800 Lowest | 1,300 ₹4,18,600 | 1,375 ₹4,42,750 | 1,350 ₹4,34,700 | 1,100 ₹3,54,200 | 1,350 ₹4,34,700 | 980 ₹3,15,560 |
| 3.00 | M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:6 icomplete all as specified and directed. | 82 | SqM | 900 ₹73,800 Lowest | 2,600 ₹2,13,200 | 2,600 ₹2,13,200 | 2,500 ₹2,05,000 | 1,200 ₹98,400 | 2,500 ₹2,05,000 | 1,650 ₹1,35,300 |
| 4.00 | M & L for double charged vitrified coloured ceramic tiles 8-9 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed. | 735 | SqM | 1,000 ₹7,35,000 Lowest | 2,600 ₹19,11,000 | 2,550 ₹18,74,250 | 2,500 ₹18,37,500 | 1,300 ₹9,55,500 | 2,500 ₹18,37,500 | 1,660 ₹12,20,100 |
| 5.00 | M & L for Vitrified coloured ceramic tiles 10 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over rendering in CM 1:4, 10 mm thick complete all as specified and as directed. | 51 | SqM | 1,100 ₹56,100 Lowest | 2,600 ₹1,32,600 | 2,550 ₹1,30,050 | 2,500 ₹1,27,500 | 1,400 ₹71,400 | 2,500 ₹1,27,500 | 1,450 ₹73,950 |
| 6.00 | M & L for Cement concrete chequered tiles 30cm x 30cm x 20mm thick, with grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry in floors, and cut
and polished laid over and including 15mm thick screed bed in CM 1:6 icomplete all as specified and directed. | 275 | SqM | 700 ₹1,92,500 | 1,150 ₹3,16,250 | 1,250 ₹3,43,750 | 1,200 ₹3,30,000 | 650 ₹1,78,750 Lowest | 1,200 ₹3,30,000 | 950 ₹2,61,250 |
| 7.00 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc including removing rubbish off the premises complete all as specified and directed. | 2.61 | 10 SqM | 250 ₹652.5 Lowest | 500 ₹1,305 | 550 ₹1,435.5 | 540 ₹1,409.4 | 500 ₹1,305 | 540 ₹1,409.4 | 400 ₹1,044 |
| 8.00 | M & L for 25mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in flooring complete all as specified and as directed. | 1,092 | SqM | 140 ₹1,52,880 | 400 ₹4,36,800 | 400 ₹4,36,800 | 350 ₹3,82,200 | 125 ₹1,36,500 Lowest | 350 ₹3,82,200 | 260 ₹2,83,920 |
| 9.00 | M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection laid to slope in panels including joints filled with mastic filling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. | 101 | SqM | 250 ₹25,250 | 450 ₹45,450 | 410 ₹41,410 | 400 ₹40,400 | 185 ₹18,685 Lowest | 400 ₹40,400 | 350 ₹35,350 |
| 10.00 | M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in sub base of floors, and finishing the surfaces complete all as specified and directed. | 551 | SqM | 250 ₹1,37,750 | 450 ₹2,47,950 | 410 ₹2,25,910 | 400 ₹2,20,400 | 185 ₹1,01,935 Lowest | 400 ₹2,20,400 | 350 ₹1,92,850 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
24 Sept 2025, 6:00 pmClosed
Col Shinde SS, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO BUILDING NO.P-2 G-SERIES VISAKHA AT ENC O MESS NAVAL BASE UNDER GE NB VISAKHAPATNAM
2025_MES_726906_1
82582/E8
Open Tender
Civil Works
Item Rate
120 days
Visakhapatnam
As per NIT
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2.0 L
Yes
13 Dec 2025
20 Aug 2025
26 Sept 2025
20 Aug 2025
24 Sept 2025
10 Sept 2025
20 Aug 2025 - 27 Aug 2025
Amount
SCHEDULE 'A' PART-I [B/R Works]: Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M & L for coloured Glazed ceramic tiles of size 300x600x7mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:6 icomplete all as specified and directed.
M & L for double charged vitrified coloured ceramic tiles 8-9 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed.
M & L for Vitrified coloured ceramic tiles 10 mm thick (square/rectangular), light shade area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over rendering in CM 1:4, 10 mm thick complete all as specified and as directed.
M & L for Cement concrete chequered tiles 30cm x 30cm x 20mm thick, with grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished laid over and including 15mm thick screed bed in CM 1:6 icomplete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc including removing rubbish off the premises complete all as specified and directed.
M & L for 25mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in flooring complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection laid to slope in panels including joints filled with mastic filling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in sub base of floors, and finishing the surfaces complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description from any position removing rubbish off the premises complete all as specified and directed.
M & L for complete removal of existing treatment on wall surfaces and applying two coats of 1st quality oil bound distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer over and including suitable thickness wall care putty for making good undulations to obtain smooth surface complete all as specified and directed.
M & L for complete removal of existing treatment on ceiling surfaces and applying two coats of 1st quality oil bound distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer over and including suitable thickness wall care putty for making good undulations to obtain smooth surface complete all as specified and directed.
M & L for complete removal of existing treatment on old decorated surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/10sqm including exterior wall care putty of suitable thickness complete all as specified and directed.
M & L for preparation of old painted Wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying Two coats of synthetic enamel paint incl wooden putty complete all as directed.
M & L for preparation of old painted Steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators, fixed partitions with one or more rebates including joining cleat for fixing etc. complete all as specified
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for window and ventilator shutters, side hung type without sash bars, aluminium sections of weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S & F anodised aluminium grill (anodised transperant or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing window frame with CP brass / stainless ateel screws @ 200mm c/c including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as directed by the Engineer-in-Charge.
M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including treated with tar or coal tar black paint complete all as specified
S & F mild steel work as in Bands, straps, hold fasts, stiffners for fencing posts, struts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S & F factory-made flush door shutters 35 mm thick (solid core, BWR grade, IS:2202 Part–I), faced on both sides with 4 mm thick decorative natural veneer (approved shade/grain), edges lipped with hardwood (6 mm thick), machine pressed with synthetic resin adhesive (IS:2046), surfaces prepared and finished with PU polish (matt / gloss as approved) to achieve smooth uniform finish, complete all as specified and directed by Engineer-in-Charge.
S & F 35mm thick, factory made Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I and fitted to Chowkats complete all as specified and as directed.
M & L for PU (Polyurethane) wood polish on new wooden surface, including preparation of new wood surface by sanding, filling of pores with approved wood filler, applying sealer coat, rubbing down, and finishing with two or more coats of PU clear polish (matt/glossy as directed) by spray/brush to obtain a durable mirror-like finish, complete all as specified and directed.
S & F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned stacks or stainless steel wire staples complete all as specified and directed.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned stacks or stainless steel wire staples complete all as specified and directed.
S & F Butt hinges, 125mm size extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
S & F Brass handles cast type of size 200 mm complete all as directed.
S & F Brass barrel Tower Bolt of size 200 mm size with cast or sheet barrel and rolled or cast bolts complete all as specified and as directed.
S & F300mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed.
S & F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as directed
S & F floor door stopper of brass body and tongue with hard drawn steel spring fixed in floor overall length of cover plate 150mm complete all as specified and as directed.
S & F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane fixed in aluminium door, windows and ventilators complete all as specified and directed.
S & F in repairs 4mm thick sheet glass, Pin head type and glazing with oil putty in squares exceeding 0.5 Sqm in each pane fixed in aluminium door, windows and ventilators complete all as specified and directed.
S & F 18 mm thick plywood (BWR grade, IS:303), commercial type, fixed in position with nails / screws / adhesive over framework or surface, complete all as specified and directed by Engineer-in-Charge.
S & F 75mm long medium weight Stainless steel Butt hinge double action self closing type complete all as specified and directed.
S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S & F 200mm long Stainless steel design handle complete all as specified and directed.
S & F 0.9mm thick decorative laminate type-1 of surface finish, colour and pattern as approved fixed with approved adhesive as per manufacturers instructions complete all as directed
M & L for Cutting / Chipping the spalled loose concrete of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guiniting/ Plastering, preparing surfaces and applying one coat of rust remover and 2 coats of Nitozinc primer on exposed steel surface, and applying a coat of Nito Bond AR of M/s Fosroc chemicals or equivalent as per manufacturer's instructions and providing pressure Guniting average 25mm thick at a pressure of not less than 6 KG / Sqcm in CM 1:3 duly mixing the mortar with and including suitable bonding agent of Fosroc chemicals or its equivalent @ 5% by weight of cement, finishing the surface rough conforming to proper geometrics to match with the existing surface including providing double scaffolding and safety measures as required and removal of the same on completion and disposal of demolished materials / debris outside MD land complete all as specified and as directed.
M & L for application of high build polymer modified cement mortar 1:2.5 mixed with 3 litres of Notoband SBR of M/s Fosroc chemicals or its equivalent per bag of cement in super structure work in two layers to form 10 to 20mm thick even surface over a coat of bonding agent by mixing Nitobond SBR of M/s Fosroc chemicals or its equivalent @ 1 Ltrs + 1 Litre water + 3 Kg of cement as per manufacturers instructions complete all as directed by the Engineer-in-Charge
M & L for Non-Shrink, Cementitious Micro Concrete using Rendroc RG manufactured by M/s Fosroc Chemicals or its equivalent modified with 12mm graded, clean, saturated surface dry crushed stone aggregate in the ratio as per manufacturers instructions, laid in average thickness of 80 to 100mm in columns, beams and similar structural members including use and waste of water tight form work to facilitate pouring of micro concrete complete all as per manufacturers instructions including providing double scaffolding and safety measures as required complete all as directed.
M & L for preparing surfaces and applyingh a coat of Zinc Rich Epoxy Primer (Nito Zinc primer of M/s Fosroc chemicals or its equivalent) as per manufacturers instructions to all steel surfaces as antirust agent including providing double scaffolding and safety measures as required complete all as directed.
M & L for RCC 1:2:4, type B-0, using 12.5mm graded stone aggregate as in cast in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed necessary form work and demolition of old concrete and removing debries complete all as specified and directed.
M & L for mild steel TMT Bars of 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces mixed with and including cement water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces, finished even and smooth with out using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/10sqm including exterior wall care putty of suitable thickness complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of 1st quality oil bound distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer over and including suitable thickness wall care putty for making good undulations to obtain smooth surface complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying two coats of 1st quality oil bound distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of primer over and including suitable thickness wall care putty for making good undulations to obtain smooth surface complete all as specified and directed.
S & F in repairs 0.71mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth) fixed complete all as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removing debris outside MD land as directed Engineer-in-Charge
M & L for PCC 1:5:10, type E-2 using 40mm graded stone aggregate as in foundation, sunken floor filling and mass concrete complete all as specified.
M & L for preparation of the sunken floor surfaces by mechanical abrading to remove all loose mortar and laitance, oil, greese, etc and washing with plenty of water making the surface sound and free from cracks by cutting 'V' grooves cut along the cracks and filling with SMARTCARE repair mortar, carryout initial pond test for 24 hours to identify any invisible cracks, injection grouting for cracks on negative side of the surface using shrink compensating grout adhesive SMARTCARE injection Grout Additive @ 250 gms/50 Kg bag of cement with neat cement slurry by drilling the hole of 12mm dia and fixing the nozzle using fast setting compound SMARTCARE instant Leak stop along the construction joints, cracks etc at a distance not more than 500mm angle fillet, providing a cement sand mortar based fillet of 50x50mm admixed with APL Smart care multi purpose polymer @ 0.25 Lit per bag of cement all around in the side at the floor and wall junction and curing by water as per standard practice, supply and applying two component elestomeric acrylic polymer modified cementetious water proofing coating, Smart Care Damp block 2K Suprema or equivalent as approved having 100% elongation as per ASTM D 412 resisting 5 bars positive hydrostatic pressure and 4 bars negative hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per ASTM C 1202 crack bridging upto 12mm as per ASTM 4548.5. The mixing ration of the coating shall be 2 parts of powder and 01 part of liquid without any water addition in the mixing complete all as per the manufacturer's instructions at a consumption factor of 1.5 Kg/Sqm in two coats complete all as directed by the Engineer-in-Charge
M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work of concrete surfaces mixed with and including admixture SMARTCARE Vitalia @ 100 ml per bag of cement finished the surface rough complete all as directed
M & L for treatment around the pipes passing through the walls (Core cut area) by wrapping around all the pipes with APL Smart Care adhere to the surfaces with APL Smart Care Acrylic Bonding Agent and placed appropriately to be grouted around the cut bores, Grouting the gaps between the pipe and the core cutting by a edual shrinkage compensated cementitious grou APL Smart Care General purpose grout that shall be poured into the gaps after fixing in place for effective leak-free shuttering complete all as per manufacturer's instructions complete all as specified and directed and by the Engineer-in-Charge.
S & F in repairs Stainless steel Towel Ring square with round flange complete all as directed. [Make shall be Jaquar of Cat No. ACN-1121N or its equivalent]
S & F in repairs Towel Rack 600mm long without lower hanger complete all as directed. [Make shall be Jaquar of Cat No. AKP-35781P or its equivalent]
S & F in repairs 15mm bore, Hand shower (Health faucet) (ABS Body) with 8mm dia, 1.2m long Spirochrome flex & wall Hook complete all as directed. [Make shall be Jaquar of Cat No. ALD-587 or its equivalent]
S & F in repairs 15mm bore fancy type Chromium plated two way bib taps, screwed down for iron pipe or for brass ferrule with flanges complete all as specified and directed. [Make shall be Jaquar of Cat Part No. FLR-5041PM or its equivalent]
S & F in repairs Paper holder with flap Recessed Type (Stainless steel) fixed to wall with brass screws complete all as specified and directed. [Make shall be Jaquar of Cat Part No. AHS-1553 or its equivalent]
S & F in repairs 15mm brass CP mixer for mixing Hot & Cold water screwed down for iron pipe and fixed complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ALI-CHR-85005B or its equivalent]
S & F in repairs 15mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. [Make shall be Jaquar of Cat Part No. KUP-35053PM or its equivalent]
S & F in repairs Chromium plated Towel rail, 60cm long between flanges complete all as directed. [Make shall be Jaquar of Cat No. ACN-CHR-1111SM or its equivalent]
S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard complete all as directed. [Make shall be Jaquar of Cat No. ACN-CHR-1173 or its equivalent]
S & F in repairs 15mm bore bib tap fancy type Chromium plated capstan head, screwed down, screwed for 15mm dia bore iron pipe complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ACN-CHR-5041N or its equivalent]
S & F in repairs Vitreous China Rimless Single Piece WC with UF soft close slim seat cover, hinges, fixing accessories, accessories set and cistern fittings of size 380x725x690mm, S Trap - 300mm and all fittings and fixtures including connection to outgoing drain including making good damaged / disturbed surfaces complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ONS-WHT-10853S300UFSM or its equivalent]
S & F in repairs Vitreous china wash hand basin, white, table top of size 495x365x150mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings complete all as directed. [Make shall be Jaquar of Cat Part No. JDS-WHT-25909 or its equivalent]
S & F in repair C.P. brass bottle trap, 32 mm bore, heavy duty, with adjustable telescopic arm and extension piece, complete with all necessary unions, nuts and washers, for counter top wash basin, fixed in position complete all as specified and directed.
S & F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as directed.
M&L for PVC (SWR) Floor/ Nahani trap of 75 mm dia outlet with 304 grade stainless steel square flat cut floor grating 125mm x 125mm with cockroach trap with or without hole as per requirement of site and as directed by Engineer-in- charge including jointing with solvent cement complete all as specified and as directed.
M&L for PVC (SWR)Multi floor trap of 75mm of 75 mm dia outlet with 304 grade stainless steel square flat cut floor grating 125mm x 125mm with cockroach trap with or without hole as per requirement of site and as directed by Engineer-in- charge including jointing with solvent cement complete all as specified and as directed.
S&F wall mounted ,700mmx500mm ,5 mm thick glass mirror with double coat for protection and longevity Grounded edges for safety and silver plating on the back for better reflection.complete all as specified and as directed. Make: Cat No : B3510114 of Cera or its equivalent as approved by GE
S & F in repairs Single Lever Wall Mixer 3 in 1 system with provision for both Hand shower and overhead shower complkete with 115mm Long bend pipe, connecting legs & wall flange complete all as specified and directed. [Make shall be Jaquar of Cat No. KUP-35125PM or its equivalent]
S & F Shower arm 20mm dia, 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Flange, Stainless Steele complete all as specified and directed. [Make shall be Jaquar of Catalogue No. SHA-CHR-479L300S or its equivalent]
S & F in repairs Shower rose single flow ABS body with CP plate & Rubbit cleaning system, 105 mm size complete all as per Jaquar Catalogue No. OHS-CHR-1709 or its equivalent complete all as specified and directed.
S & F Exposed part kit of Concealed stop cock & Flush cock of Jaquar make model ALI-CHR-85083 or its equivalent including regular body of concealed stop cock of Jaquar make model ALI-CHR-083FT or equivalent complete as per manufacturer's instructions and as required at site complete all as specified and directed.
S & F Double arm wall mounted reversible Plain/magnifying (X3) pivotal Mirror of Jaquar make cat No CAN-1193N complete as per manufacturers instructions.complete all as specified and directed.
S & F in repair stainless steel curtain rod, 25 mm dia, 1.0 mm thick, AISI 304 grade, polished finish complete with PVC curtain hooks (heavy duty, unbreakable type) of approved make, fixed in position including cutting, drilling and making good disturbed surfaces, complete all as specified and directed.
S & F in repairs Decorative type Stainless Steel Brackets with suitable for 25mm dia curtain rods complete all as specified and as directed.
S & F CPVC Pipes 16 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable existing pipes complete all as specified and as directed.
S & F CPVC Pipes 32 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable existing pipes complete all as specified and as directed.
S & F CPVC Pipes 50 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable existing pipes complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 Mpa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs gun metal, globe or gate valves, 32mm bore with iron wheel head, screwed both ends for iron pipe complete with two CPVC transition fittings 32 mm (CPVC × brass female adaptor/unions), solvent-welded to existing/new CPVC pipe complete all as specified and as directed.
S & F in repairs gun metal, globe or gate valves, 50mm bore with iron wheel head, screwed both ends for iron pipe complete with two CPVC transition fittings 50 mm (CPVC × brass female adaptor/unions), solvent-welded to existing/new CPVC pipe complete all as specified and as directed.
Taking down Eaves Gutters /SWR Pipes [any size or pattern], including all fittings, heads, shoes, bends, swan-necks, etc. from any height complete all as specified and as directed.
S & F 110mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, fixed to walls in any position with necessary brackets, clamps, bolts, nuts, etc., complete all as specified and as directed.
S & F 110mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, laid in trenches or in floors complete all as specified and as directed.
S & F 75mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, fixed to walls in any position with necessary brackets, clamps, bolts, nuts, etc., complete all as specified and as directed.
S & F 75mm bore UPVC [SWR] pipes single socketed, in any length with rubber ring/ solvent cement joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110 mm bore UPVC [SWR] bends, any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore UPVC [SWR] bends, any radius with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore UPVC [SWR] bends, any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore UPVC [SWR] bends, any radius with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore UPVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore UPVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore UPVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F 125/110mm bore PVC [SWR] Gully Trap with grating including jointing with solvent cement complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing Precast Cement Concrete 1:2:4, Type B-1 using 20mm graded stone aggregate as in solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:6 including demolition of old Brick / Stone Masonry built in cement mortar complete all as specified and directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work including demolition of old Brick / Stone Masonry built in cement mortar complete all as specified and directed.
S & F in repairs Seamless False Ceiling Frame Work using GI perimeter channels of 0.55 mm thick, having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, fixed to wall with nylon sleeves and screws at 450 mm intervals, GI intermediate channels of size 45 mm X 15 mm X 0.90 mm supported with GI ceiling angles of size 25 mm X 10 mm X 0.55 mm fixed to soffits with steel expansion fasteners / GI cleats at 900 mm intervals, ceiling section of 0.55 mm thick having knurled web of 50 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channel with connecting clips and in direction perpendicular to the intermediate channels at 457 mm centre to centre including fixing Gypsum board of 12.0 mm thick conforming to IS – 2095 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including applying Two Coats of Acrylic Washable Distemper over putty of suitable thick and a coat of Alkali Resistant Primer including dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
S & F designer cornices moulding suitable for seamless ceiling board not less than 75mm wide or as per the manufacture's instructions complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish off the premises complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Bed blocks and Bed plates,copings,roof padding and the like including weathering, slightly rounded or chamfered angles and throating, necessary form work etc complete all as specified and directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, applying bituminous oil emulsion @ 0.50 Kg/Sqm, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top and finished with Two coats of silver paint including taking down existing Roof Treatment of any description and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed. Note: The rate quoted shall be deemed to include cost of Water proofing compound and nothing shall be paid extra on this account.
M & L Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed
M & L Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed
S & F in Repairs 10 mm thick tempered glass shower cubical including hinged glass door and necessary stainless steel fittings and fixtures all as per manufacturers instructions complete all as specified and as directed [Make shall be Jaquar of Cat No. IARA;1840-L or its equivalent]
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
M & L for PCC 1:3:6, type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified.
M & L for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 including demolition of existing cement concrete and removing debris not exc 100m complete all as specified and as directed.
M & L for High Strength Corrosion Resistant Deformed TMT Bars of 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Removing excavated material /soil to a distance exc 1.5 Km but not exceeding 5.0 Km and depositing where directed complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. (Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.)
M & L for Reinforced concrete pipes, 200mm bore, class NP2, laid and jointed complete with collars including demolition and breaking up of old drain pipes complete all as directed
M & L for concrete bed to drain pipes of size 200 mm bore packing under and haunching against the sides of pipes after they are laid and tested in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 200 mm dia of pipe complete all as specified and as directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks including demolition of old brick work complete all as specified and directed.
M & L for PCC 1:2:4, type B-1 using 20mm graded stone aggregate as in surface channels complete all as specified.
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mired /stopped ends etc. complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M & L for providing two components acrylic polymer modified cementitious elastomeric water proof coating, minimum 1.5 mm thickness [DFT], with nominal coverage of 2.2 Kg/Sqm including thorough preparation of surfaces by mechanical means to obtain a plain and level surface including sprinkling of clean and washed sand on final coat when wet all as per manufacturuer's instructions, as specified and as directed. Notes: [a] The coating shall have minimum 1 N/mm2 tensile strength, elongation of a min 80% when tested as per ASTM D 412, resisting 5 bar hydrostatic pressure as per DIN 1048 and having crack bridging ability of upto 2 mm. [b] The coating shall cover all the wet areas of floor and the vertical walls for a height of minimum 4 feet above the floor. [b] The rate quoted shall be deemed to include for the following: [i] Filling of all cracks and crevices with approved epoxy based mortar and made good to receive waterproofing coating treatment. [ii] Providing additional coat reinforced with a fibre band sandwiched between 1st and 2nd coat along the periphery of the toilet floors, around protrusions and around pipes.
S & F factory-made FRP (Fibre Reinforced Plastic) chajja, minimum thickness 4.0 mm, manufactured by moulded / hand lay-up process using unsaturated polyester resin with E-glass fibre reinforcement (conforming to IS:14856), with in-built slope (minimum 1:30) for drainage, external surface finished with UV-resistant coloured gel-coat (minimum 400 micron thick), internal surface smooth resin-rich finish; chajja of required projection and width, edges rounded, supported on mild steel brackets (ISA 40×40×5 mm) duly primed with zinc-chromate primer and painted with two coats of synthetic enamel paint, fixed to RCC wall with anchor fasteners including grouting and making good disturbed surfaces in cement mortar (1:3), complete all as specified and directed.
M & L for panelling work all around door openings with 19 mm thick Block Board (BWR grade, IS:1659), finished on exposed surfaces with 4 mm thick decorative natural veneer (approved shade/pattern), edges lipped with matching veneer strips, machine pressed with synthetic resin adhesive (IS:2046), surfaces prepared and finished with PU polish (matt / glossy as approved) to achieve smooth uniform finish; panelling fixed to wall using concealed fasteners (Z-clips / aluminium cleats / approved system) ensuring flush surface without visible screws, including preparation of surfaces and making good disturbed wall finishes, complete all as specified and directed.
M & L for decorative fluted wall/ celing panels, factory-made, using high density MDF / WPC base board (minimum 12 mm thick, IS:12406 for MDF / IS:10176 for WPC), hot pressed with decorative laminate / PVC foil finish, water and termite resistant, fire-retardant grade, with uniform fluted profile (pitch 25–50 mm, depth 8–12 mm), edges finished with matching laminate strips, panels fixed to wall surface with concealed aluminium / PVC cleats and synthetic resin adhesive (IS:2046), including preparation of surfaces, making good disturbed areas, and finishing complete all as specified and directed by Engineer-in-Charge.
S & F cylindrical lock set (entrance type), heavy duty, having lock body of stainless steel / brass, latch bolt of minimum 12 mm throw, backset 60 mm (±5 mm), operation by key from outside and knob turn from inside, supplied complete with striker plate, fixing screws, and 3 Nos. brass keys in duplicate, corrosion-resistant satin / CP brass / SS finish as approved; fixed in position complete all as specified and directed by Engineer-in-Charge.
M & L for cupboard shutters / Panelling work 19 mm thick, factory made from Block Board (BWR grade, IS:1659), finished on both sides with 1.0 mm thick decorative laminate (ISI marked, shade/pattern as approved by Engineer-in-Charge), edges lipped with matching mica strips, machine pressed with synthetic resin adhesive (as per IS:2046) to obtain uniform finish, including preparation of surfaces, rounding/finishing edges complete all as specified and directed.
SCHEDULE 'A' PART-II [E/M Works]: M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point including taking down old point wiring with fixtures and fittings complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting through wall, chasing, pinning in making good to the disturbed surfaces whrever required]
All as per Serial Item No. 137 above but One light point controlled by Two way switch complete all as specified.
All as per Serial Item No. 137 above but One 3 Pin Socket Outlet 5 Amps on same Board complete all as specified.
All as per Serial Item No. 137 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 137 above but one 3 Pin Switch Socket Outlet 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 137 above but one 3 Pin Switch Socket Outlet 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 5 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps cum 3 pin 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Bell Push, Modular type, one module, Single Pole, 6 Amps, 230 Volts complete all as specified and as directed.
S & F TV outlet socket with metal box mini complete all as specified and as directed. Make:- Anchor cat No. 21157 or its equivalent.
S & F Telephonic jack deluxe with shutter single line with metal box complete all as specified and as directed. Make:- Anchor cat No. 20857 or its equivalent.
S & F RJ45 computer /LAN jack with shutter and metal box mini complete all as specified and as directed. Make:- Anchor cat No. 30555 or its equivalent.
S & F SRCD protected socket, steel enclosure with two pin and earth plug and socket with 20 amps MCB SP complete all as specified and as directed. Make :-Havells cat part No. DHDDCDP025202003 or its equivalent.
S & F SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring complete all as specified and as directed. (Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit)
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring complete all as specified and as directed. (Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit)
M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capacitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with one coat of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
M & L for Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Nuts & Bolts, washers, etc. including cleaning, greasing and spray painting with one coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient Sleek decorative LED Mirror Light Fitting of not less than 1000 Lumens, 2 feet long Surface & Wall mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Lamp Holder, PVC/Polycarbonate type with Back Plate, 230 Volts for Batten Fittings complete all as specified and as directed.
S & F in repairs LED Bulb of not less than 900 Lumens output, 3000 K, IP40 operating voltage 90-270 Volts, AC, 50 Hz, Natural white colour complete all as specified and as directed. Make :-Jaquar Cat No. JQM-WHT-LPRM4KV09B2C or its equivalent.
S & F in repairs Recess mounted downlight, round/square in shape, 15 Watt, as per existing cut out 160-180 mm and making flush smooth with gypsum board, CCT: WW/NW/CW, CRI>80 Ra IP 20 rated, die cast aluminium housing, white finish with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and as directed.
S & F in repairs Recess mounted downlight, round/square in shape, 18 Watt, as per existing cut out 160-180 mm and making flush smooth with gypsum board, CCT: WW/NW/CW, CRI>80 Ra IP 20 rated, die cast aluminium housing, white finish with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and as directed.
S & F in repairs Vertical DB double door for provision for four pole MCCB upto 125 A incommer 6 way 18 outgoing with IP 43 protection complete all as specified and as directed. Make:-Hager Cat Part No. VYV06DL-P double door or its equivalent.
S & F in repairs MCCB 415 V , 25 KA, 4 Pole, 100 Amps capacity complete all as specified and as directed. Make :-Hager Cat Part No. HNS101DR or its equivalent.
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F in repairs MCB, SPN, 40-63 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed. Make :-Havells Cat Part No. DHMGCSNF040 or its equivalent.
S & F in repairs MCB, SP, 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed. Make :-Havells Cat Part No. DHMGCSPF006-032 or its equivalent.
S & F Energy efficient & Long life Security Light Luminaire, 35 Watt with Pressure die-cast Aluminium housing, IP 65 Protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 40 mm bore GI Tube, light Grade of size not less than 1.5 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm inmcluding taking down old light fittings with brackets complete all as specified and as directed.Note: Light fitting shall be of PF>0.95
M & L for Overhauling of Geysers of 25 capacity of any make by dismantling the geyser by removing from its position by disconnecting electric connection, inlet & outlet water supply connections, detecting the leakage by removing the copper vessel and rectifying by soldering, testing, refixing in position including spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and replacement of Spares such as Heating Element, Thermostat, Plug Top, Indication Lamps, PVC Connection for Hot & Cold water and other minor components etc. complete all as specified and directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Light Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and rock Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, rock Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 15 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F Rigid non-metalic 20 mm dia PVC conduit exclusive of boxes(junction/terminal) but inclusive of all tees, bends, elbows, reducer, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hook etc. complete all as specified and as directed.
S & F in repairs Earth continuity conductor or main earthing lead made of 4 mm GI Wire [Earth Lead] , fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
Taking down and refixing Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
S & F in repairs GI strip of size 32x6mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Taking down existing Air termination, single pointed aluminium rod 12mm dia and 300mm long and refixing the same complete all as specified and directed.
S & F Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 Nos 25mm long hexagonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as directed
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected with GI earth strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including taking out old perished earth pits complete all as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4 type B-1 cover 40mm thick with 8mm dia steel reinforcement bars at 150mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the electrode complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 50 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls and connecting up with suitable glands, lugs, nuts and bolts and testing on completion including taking out old unserviceable cable complete all as specified and directed by the Engineer-in-Charge.
Supply and laying GI pipe 80mm bore, light for cable protection laid in trenches complete all as directed
M & L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
Supply and laying common burnt burnt building clay bricks of sub-class 'B' designation 75 complete all as directed
S & F CPVC Pipes 16 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes complete all as specified and as directed.
S & F UPVC cable trunking of size 50mmx50mm made with 2 mm thick sheet jointed with connectors including all tees, right angle bends, suspenders, bolts, nuts, washers etc and cable tray fixing iron bracket with suitable size and connecting accessories complete all as specified and as directed.
S A R CONSTRUCTIONS (BID ID -3434534)
Pavan Commercial Company (BID ID -3434544)
Sri Surya Enterprises (BID ID -3433904)
S R CONSTRUCTIONS (BID ID -3434812)
M/s.DSRK CONSTRUCTIONS (BID ID -3434046)
srisampathassociates (BID ID -3433913)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .