| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 121004 | ₹7.5 L Quoted ₹7.6 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹7.8 L+₹21,157.50 (2.77%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | ₹7.8 L+₹21,157.50 (2.77%) | L2 | Rejected-AOC being L2 |
| 3 | L3₹9.6 L+₹1.9 L (25.3%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹9.6 L+₹1.9 L (25.3%) | L3 | Rejected-AOC being L3 |
| 4 | L4₹11.1 L+₹3.4 L (44.8%)Rejected-AOC | ₹11.1 L+₹3.4 L (44.8%) | L4 | Rejected-AOC being L4 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
28 Jan 2022, 6:00 pmClosed
AGE (I) Cannanore
AGE (I) Cannanore HQ Hospital Kannur PO Kannur
Repairs and maintenance to LT Panels, APFC panel, replacing of MCCBs and connected misc work at Kannur under AGE (I) CANNANORE.
2022_MES_498731_1
8163
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
Class E category b (I)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Cannanore
₹18,000
Yes
25 Feb 2022
1 Jan 2022
1 Feb 2022
2 Jan 2022
28 Jan 2022
15 Jan 2022
2 Jan 2022 - 8 Jan 2022
Amount
Taking down/removing of unserviceable items from the existing Automatic power factor correction (APFC) panel of three phase 415 Volt, 50Hz system of capacity 5 KVAR and Supply and fixing Cylindrical capacitors 440 V, 50 Hz, 3 phase, 5 KVAR of model torrent of Havells or equivalent of L&T and electrically connecting up complete all as directed.
All as per item No 1 here in before but Cylindrical capacitors 440 V, 50 Hz, 3 phase, 10 KVAR of model torrent of Havells or equivalent of L&T and electrically connecting up complete all as directed.
All as per item No 1 here in before but Cylindrical capacitors 440 V, 50 Hz, 3 phase, 20 to 30 KVAR of model torrent of Havells or equivalent of L&T and electrically connecting up complete all as directed.
Taking down/removing of unserviceable items from the existing Automatic power factor correction (APFC) panel of three phase 415 Volt, 50Hz system of capacity 30/40/50 KVAR and Supply and fixing capacitor duty contactor type MO C 12.5, 440 V, 50 Hz, 3 phase, of Havells or equivalent of L&T and electrically connecting up complete all as directed.
Taking down old unserviceable LT distribution panel, Supply, installing, testing and commissioning of CPRI approved LT distribution panel outdoor type of size minimum 180cmx45cmx150cm (lengthxwidthxheight) or larger suitable size weather/vermin proof, made out of 3.15mm thick CRCA sheet duly powder coated, mounted on 65x65x6mm (ISA6565) iron angles frame of height 45 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level with inclusive of following items complete all as specified and directed. a) MCCB 4 pole ,36 KA, 415 V with thermal magnatic release 400 Amps -01 Nos ( for Incoming) L&T Cat No - CM98403OOROOG, Type - DN3B-400D b) MCCB 4 pole ,36 KA, 415 V 320 Amps-1 Nos ( for In out going) L& T Cat No -CM98404OOQO c)MCCB 4 pole ,36 KA, 415 V 125 Amps-3 Nos ( for In out going) L& T Cat No - CM98065OOMO g) Bus bar set of aluminium 600 Amps for R Y B and 300 Amps for neutral with epoxy insulated coating with colour code and insulated support - 01 Set h) Internal wiring of panel board with suitable size FRLSH grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job j) Indicating lamps for R Y B - 01 Set k) Volt meter 0-500 Volt Range - 01 No l) Ammeter 0-500 Amps Capacity - 01 No m) Earth falt module with Built in CBCT 100 Amps to 200 Amps Range - 01 No L&T Cat No - ST27745OOOO Note:- Rate quoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
Taking down old unserviceable LT distribution panel and Supply, installing, testing and commissioning of CPRI approved LT distribution panel outdoor type of size minimum 180cmx45cmx150cm (lengthxwidthxhight) or larger suitable size weather/vermin proof, made out of 3.15mm thick CRCA sheet duly powder coated, mounted on 65x65x6mm (ISA6565) iron angles frame of hight 45 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level with inclusive of following items complete all as specified and directed. a) MCCB 4 pole ,36 KA, 415 V with thermal magnatic release 320 Amps-1 Nos ( for In out going) L& T Cat No - CM98403OOROOG b) MCCB 4 pole ,25 KA, 415 V 125 Amps-2 Nos ( for out going) L& T Cat No -CM98065OOMO c) MCCB 4 pole ,25 KA, 415 V 100 Amps-1 Nos (for out going) L& T Cat No - CM90677OOLO d) MCCB 4 pole ,18 KA, 415 V 63 Amps-2 Nos (out going) L& T Cat No - CM90518OOJO e) MCB SPN/DP 32 Amps, 415 Volts - 1 Nos L& T Cat No - BB20320C f) Changeover switch ON Load type 125 Amps, 4 pople, 440 V - 01 No L&T Cat No - CO21250OOOO g) Bus bar set of aluminium 500 Amps for R Y B and 200 Amps for neutral with epoxy insulated coating with colour code and insulated support - 01 Set h) Internal wiring of panel board with suitable size FRLSH grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job j) Indicating lamps for R Y B - 01 Set k) Volt meter 0-500 Volt Range - 01 No l) Ammeter 0-500 Amps Capacity - 01 No m) Earth falt module with Built in CBCT 100 Amps to 200 Amps Range - 01 No L&T Cat No - ST27745OOOO Note:- Rate quoted shall include Electrical connection of cable at both ends through cable glands/ aluminium lugs.
Preparation of old treated surfaces by scraping down of LT panel of size 0.9 m x 1.3 m x 0.4m (new record office) complete and applying spray painting by using spray gun, compressor and stand by DG set of suitable capacity, two coats of synthetic enamel paint (externally and internally) of smoke grey colour over one coat of red oxide primer, including writing incoming/out going locations in white colour of suitable font all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 1.40 m x 1.50 mx 0.5m ( OTM pump house and OTM A Block) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 1.1 m x 1.25 M x 0.4 m (OTM PH and Offrs mess) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 0.9 m x 1.2 M x 0.30 m Offrs mess,) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 0.9 m x 1.0 M x 0.40 m (Main office WL-1 and OTM PH,) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 1.9 m x 1.8 M x 0.40 m (OTM,) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 1.1 m x 1.3 m x 0.4m (new record office) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 1.6 m x 1.85 m x 0.4 m ( INP transformer yard) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size1.65 m x 1.35 m x 0.4m ( Take over point) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size1.8 m x 1.45 m x 0.4 m ( MH transformer yard) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 2.2 m x 2.5 m x 0.4m (old record office, ) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 0.90 m x 0.70 m x 0.4m (Take over point Trans former Yard) all as directed by Engineer in Charge.
All as per item No 7 here in before but panel of size 0.70 m x 1.00 m x 0.4m (INP Trans former Yard) all as directed by Engineer in Charge.
Repairing to existing LT panel at site by welding the hinges, replacing of front and back cover sheet as required at site, preparation of old treated surfaces of panel of aprox size 0.5 mx 0.6mx 0.35m and applying spray painting by using spray gun, compressor and stand by DG set of suitable capacity, two coats of synthetic enamel paint (externally and internally) of smoke grey colour over one coat of red oxide primer. Replacing of all internal panel board wiring with PVC insulated copper wire of 4/6 sqmm complete all as directed by Engr-in-Charge. (Location- Take over point and INP transformer yard).
M & L for grubbing out vegitation, grass, scrubs and bushes growing around the panel board and yard by mannually / mechanically, remove outside MD land and keep the yard area neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean upto the completion of contract.
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm spreading and levelling at sub station yard all as directed and specified.
Supply and fixing MCCB , 4 pole, 400 Amps, adjustable type, rupturing capacity 36 KA, 415 Volts with Thermal - Magnetic Release of Make L&T Cat No : CM98403OOROOG, Type - DN3B-400D or equivallent in Schneider/ABB/Havells elctrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 250 Amps, adjustable type, rupturing capacity 36 KA, 415 Volts with Thermal - Magnetic of Release make L&T Cat No : CM92109OOP1OG, Type - DN2-250D or equivallent in Schneider/ABB/Havells electrically connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 160 Amps, adjustable type, rupturing capacity 25 KA, 415 Volts with Thermal - Magnetic Release make L&T Cat No : CM90642OOMO, Type - DN1-250C or equivallent in Schneider/ABB/Havells connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 125 Amps, adjustable type, rupturing capacity 25 KA, 415 Volts with Thermal - Magnetic Release make L&T Cat No : CM90642OOMO, Type - DN1-250C or equivallent in Schneider/ABB/Havells connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCCB , 4 pole, 100 Amps, adjustable type, rupturing capacity 25 KA, 415 Volts with Thermal - Magnetic Release make L&T Cat No : CM90642OOLO, Type - DN0-100C or equivallent in Schneider/ABB connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCB, TPN, 415 volt, 63 amps, C curve, including taking down/removing of U/s MCB from existing LT panel after disconnecting electric connetion complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit vertically to a depth of not less than 2.25 m below ground level) with top edge of plate at a depth of not less than 1.5 m below normal ground level, connected to galvanized iron strip of 25 x 3 mm as earth lead and all as directed. by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, continuous earth lead protected by using GI pipe light grade 40mm bore, 20 mm dia GI pipe medium grade for watering funnel including necessary excavation, earth work in any type of strata, PCC pit and RCC chamber cover complete all as specified and as shown in electrical plate No 3 of SSR Part-I including dismantling old unserviceable earthing all as directed. Note :- Rate quoted shall deem to include for GI earth wire and GI pipe lead upto 7.5m length.
JEETH CONSTRUCTION
Sreekrupa Enterprises
BHARATH TECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .