Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4 LAccepted-AOC PLOT NO 18 19 20 PART AMBIT PARK ROAD SIDCO INDUSTRIAL ESTATE SOUTH PHASE AMBATTUR CHENNAI TAMIL NADU 600058 | CHENNAI | TAMIL NADU | 600058 | L1 | Accepted-AOC As per PC Decision | |
| 2 | Rejected-Technical 15 111 KADEKUZHI NELIKKAL THEERADESHA ROAD KUNDANNOOR MARADU P O ERNAKULAM KERALA 682304 | ERNAKULAM | KERALA | 682304 | - | Rejected-Technical Technically not qualified |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
7 Feb 2022, 3:00 pmClosed
Registrar KFRI
Kerala Forest Research Institute , Peechi P.O., Thrissur District , Kerala State Pin 680653
Supply of Refrigerated Centrifuge to KFRI
2022_KCSTE_466550_1
KFRI/1629/2021-ASST (P2)-01
Open Tender
Equipments
Item Rate
15 days
KFRI Peechi
Please refer Tender documents.
5 documents required · 5 mandatory
₹800
Yes
₹4,000
Yes
28 May 2024
10 Jan 2022
8 Feb 2022
10 Jan 2022
7 Feb 2022
10 Jan 2022
Amount
Refrigerated centrifuge:
Technical Specifications 1. Maximum speed: 30,000 x g RCF / 17,500 RPM, with a brushless motor 2. Speed setting should be possible in both RPM and RCF 3. Temperature range : -11°C to 40°C and should be able to maintain 4°C at maximum speed 4. System should be capable of using both fixed angle and swing bucket rotors 5. System should be able to accomodate dedicated rotors for 5 ml tubes 6. System should be possible to use aerosol tight rotor. Aerosol tightness of rotor should be certified by a third-party agency 7. System should have an in-built condensate drain to prevent water accumulation 8. System should have fast temperature function for rapid cooling of centrifuge 9. System should have a programmable temperature function to allow automatic precooling based on pre-programmable time and date 10. System should be possible to store a minimum of 50 programs with 5 quick access program keys 11. System should be able to start the timer count only when the set centrifugation RPM is reached, to support the short spin protocols 12. System should possess a separate short spin key for brief spin with user defined speed for brief spinning 13. System should be possible to program compressor shut off after a definite hours of non-usage of the centrifuge 14. System should have the flexibility to accommodate rotors for different formats of tubes starting from 0.2 mL PCR tubes up to spin column tubes 15. System should have automatic rotor recognition facility to automatically recognize and set maximum speeds upon rotor change 16. System should be possible to perform gentle acceleration and deceleration using dedicated key 17. System should have lock function preventing program setting overwritten or changing 18. System should be menu-driven with backlit display 19. Noise levels should be ˂ 54 db(A) for quite operation 20. Should have facility to validate speed temp and time with certified device 21. System must have an USB-port for service maintenance Rotors: 22. Should be supplied with a fixed angle rotor for 6 x 15/50 mL conical tubes with maximum speed of 7,000 rpm and 7,500 x g and 23. Metallic rotor lid should be available 24. Rotor and rotor lids should be autoclavable 25. Rotor lids should have a QuickLock-system for quick opening and closing of rotor lid Warranty: Minimum two years
Eppendorf India limited
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_668138.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .