Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹3.4 L+₹42,201 (14.0%)Rejected-Finance 589 BC BAZAR AMBALA CANTT AMBALA | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹3.6 L+₹54,171 (18.0%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
15 Jun 2023, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR TO INTERNAL WIRING, FITTINGS AND FIXTURES IN MD AT DEFENCE LAB JODHPUR
2023_MES_597604_1
8540/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹9,000
Yes
22 Mar 2024
23 May 2023
17 Jun 2023
23 May 2023
15 Jun 2023
1 Jun 2023
24 May 2023 - 31 May 2023
Amount
S&F in repairs Switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed by engineer in charge. NOTE :-(Applicable to All Items Sr No:-01 to 28 ) (i) Contractor or his/her representative will report to E/M complaint cell with 01 Electrician and 01 Helper along with T&P to receive complaints in the morning 0900 hrs with necassary daily stores as requested to attend day to day complaints (ii) The complaints should be attended & completed within 72 Hrs after receiving the complaint slip failing which a penality of Rs 500 /-will be recovered for each complaint from the contractor payment (iii) The cost of Electrician (Skilled ) & Helper(Semiskilled ) should be deemed to be included in the item rates quoted by the contractor,nothing will be paid extra for hiring the skilled labour (iv) The contract can be made operational for 09 month irrespective of qty provided in BOQ (v) The contractor shall note that the electrician and the helper should have their individual bycycle/vehicle to attend the complaints (vi) The contractor shall note that electrician and helper employed should have basic/keypad mobile with them for the easy communication with E/M complaint cell/user/JE/Engr-in-charge.
S&F in repairs Switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed by engineer in charge.
S&F in repairs Socket outlets 6 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer in charge.
S&F in repairs Socket outlets 6/16 2-in-1,3 pin Amps, 230 V AC flush type, complete all as specified and directed by engineer in charge.
S&F in repairs Switch socket combination 6 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer in charge.
S&F in repairs Switch socket combination 6/16 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and directed by engineer in charge.
S&F in repairs Ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and directed by engineer in charge.
S&F in repairs MCB SP ‘C’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed by Engineer in charge.
S&F in repairs MCB SP ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed by Engineer in charge.
S&F in repairs MCB SPN ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed by Engineer in charge.
S&F in repairs MCB TP ‘C’ curve, 10KA 25 to 63 amps including necessary connection complete all as specified and directed by Engineer in charge.
S&F in repairs MCCB Thermal magnetic protection type, 16KA, 125 amps,3 pole including necessary connection complete all as specified and directed by Engineer in charge.
S&F in repairs Single pole enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps complete all as specified and directed by engineer in charge.
S&F in repairs Factory made DB SPN 8 way double door with 200 Amps rated bus bar concealed in wall IP 43 protection for fixing MCB complete all as specified and directed by Engineer in charge.
Supply and fix 2.50 Sqmm FRLS PVC insulated multi-stranded copper conductor, single core cable for connections including taking down old unserviceable connections complete all as specified and directed by engineer in charge. Note:- Each wire shall be measured.
Taking down Ceiling fan/exhuast fan, sealing cable end dismantling blades and removing fan and blades to store for refixing all as specified and directed by Engineer-in-charge
M&L for repair of Ceiling fan 1200/1400 mm sweep of any make obtained from above item, rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
M&L for repair of Exhaust fan of any sweep of any make obtained from taking down, rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
Supply and fix in repairs suitable Step type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by engineer in charge.
S&F in repairs capacitor 2.5 MFD suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and directed by Engineer-in-charge.
S&F in repairs heating element ISI marked suitable for existing 25/35 litre capacity geyser complete all as specified and directed by engineer in charge.
S&F in repairs, thermostate ISI marked suitable for existing 25/35 litre capacity geyser complete all as specified and directed by engineer in charge.
S&F in replacement assembly of existing make of stainless steel body geyser 25/35 litre capacity complete all as specified and directed by engineer in charge.
S&F in repairs Batten holder sutable for existing LED bulb ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement LED bulb of 9watt,6500K complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement LED light fitting 1x10 W Bulk Head lumanaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge. Make:Bajaj/Crompton /Havells.
S&F in repairs straight linear,white two feet 10W LED light with batten connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement radiance ray plus 24 Watt cool day LED batten light complete all as specified and directed by Engineer-in-charge.(Crompton cat part No:LDRR24-CDL or equivalent make as approved by AGE(I) R&D Jodhpur)
VARDHMAN SALES CORPORATION
vinayandsons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .