Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.6 L+₹75,424.24 (2.44%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹32.1 L+₹1.2 L (3.95%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹32.1 L+₹1.3 L (4.06%)Rejected-Finance | L4 | Rejected-Finance Not L1. | |
| 5 | L5₹32.5 L+₹1.6 L (5.31%)Rejected-Finance | L5 | Rejected-Finance Not L1. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Dec 2023, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINT OF UNSERVICABLE FLOOD LIGHTS, MOTOR CHAIN MACHANISM OF HIGH MAST LIGHT, AVIATION LIGHTS, LIGHTENING PROTECTION OF OVERHEAD TANKS, TOWER AND E/M INSTALLATIONS IN AF-II AREA UNDER GE (AF) JAMNAGAR NO.2
2023_MES_628255_1
8478/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹60,000
Yes
16 Jan 2024
14 Nov 2023
13 Dec 2023
14 Nov 2023
12 Dec 2023
28 Nov 2023
Amount
Demolition of cement concrete of any description and in any position not other wise specially provided for incl removal of old debris out side the MD land complete all as specified and directed.
Dismantling fencing wire mesh / chain link fencing, any type complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B 0 (using 12.5 mm graded stone aggregate) as in padding in roof complete all as specified and directed.
M&L for 10 mm thick rendering plastering in CM 1: 4, on concrete surfaces, with WPC as per the manufacturers instructions, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid seperately.
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces or stone masonry surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral WPC
M&L for applying cold bituminous Primer on plastered roof surfaces with bituminous primer @ 0.3 kg / sqm as per IS 3384 and laying APP(Atactic polypropylene polymer) modified membrane 3mm thick (weight not less than 3.5 kg / sqm with reinforced non woven polyester mat as core reinforcing media suitably finished with mineral laid on top with 100mm side overlap and 100mm width overlap sealing all round as per manufacturer instruction complete after picking sweeping wire brushing and cleaning top surfaces of cement concrete complete all as specified and directed. Note : The membrane has to be laid with LPG torch and overap sealed and finished neat.
M&L for repairing the edge / corner of chajja / roof projection and similar work by removing of plastered width / girth exceeding 15 cm & n exc 30cm and making good with 15 mm rendering in cement mortar 1:3 to match with existing surfaces complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick wall including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick cement plaster in cm 1:4 on the brick surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 05 mm thick on on fair faces of concrete surfaces in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed.
M & L for preparation of old existing treatment surfaces on wall and applying one coat of of weather proof acrylic based emulsion paint (100% acrylic) over a coat of primer including preparation of old surfaces complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacestwo coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete all as specified and directed.
M&L for preparation of old existing treated surfaces and applying one coat of white wash in ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash in ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls & applying three coats of white wash on wall surfaces complete all as specified and directed.
M&L for complete removal of existing treatment from wall and applying two coats of white wash on wall surfaces complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed
Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed
Taking up or down 25 mm bore steel tubing and connections, complete all as specified and as directed
Dismantling water tanks and removing to store but for exc 250 & n exc 500 litres site complete all as specified and directed.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
Supply and fix 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 500 litre capacity tripple layer. (cylindrical vertical with closed top) hoisted and fixed in position, including all fitting such as connection, nipple etc and dismantling the same complete all as specified and directed.
S&F in repairs Gun metal gate valve, with iron wheel head screwed both ends for 20 mm bore pipe complete all as specified and directed.
S&F in repairs Gun metal gate valve, with iron wheel head screwed both ends for 25 mm bore pipe complete all as specified and directed.
S&F in repairs 25mm bore Ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe fixed complete all as specified and directed.
Excavating trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm for hard dense soil complete all as specified and directed.
Removing excavated material exc 250 m and n.exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M & L for precast cement concrete (1:3:6) (using 20mm graded stone aggregate) type C1 solid building blocks exc 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 in wall or pillars complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from natural ground and making good disturbed ground complete all as specified and directed.
S&F GI Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed end to be fitted with washers and one hexagonal or square nut n exc 5 cm long, diamete of neck 5 to 10 mm complete all as specified and directed.
Supply only chain link MS galvanised fencing,of Aperture 50x50 cm, conforming to IS 2721:2003 including line wires of 4 mm dia straining bolts, etc including provision of binding wire complete all as specified and directed.
Fixing only chain link fencing including lines wires, any mesh size and type to any type of standards, rails, straining bolts, etc including provision of inding wire complete all as specified and directed.
S&F PVC coated chain link fencing 50mm x 50mm x 4mm thick mesh secured with MS flats, straining bolts including provision of binding wire complete all as specified and directed. Note: Straining bolts, nuts and washers as supply only, flat iron and 10 mm dia round bars shall be, measured and paid supperately.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc confirming to Fe-290 (Gde-E-165) quantity-A complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails or guides) and hanging, also fastening and fixing complete all as specified and directed.
Dismantling of wrought iron or mild steel of any description not otherwise provided for complete all as specified and directed.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for preparing new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide etc. complete all as specified and directed.
M&L for preparation of old painted steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for RCC (Nominal mix) type B1 1:1.5:3 (using 20mm graded stone aggregate) for foundations, including rafts, footings, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (Nominal mix) Type B1 1:1.5:3 (using 20mm graded stone aggregate) for Columns, pillars, piers, posts and struts complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished surfaces complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed.
M & L for broken stone hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:3:6, type C-2, (using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and directed.
Demolition of reinforced cement concrete (including cutting of reinforcement as required to facilitate demolition) in any position and of any description complete all as specified and directed.
M&L for providing precast cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) in landings, cover slabs (for man holes etc.) chullahhoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6 complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for providing, cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, bed blocks, bed plates complete all as specified and directed.
Resecuring without taking down chowkats or frames but with shutters (without taking off shutter from the frames) exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed.
Taking down shutters of any description exc 2 sq. m each complete all as specified and directed.
S&F for Steel rolling shutters of 1mm thickness of laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Taking down chowkats or frames but with shutters (without taking off shutter from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frames but with shutters (without taking off shutter from the frames) exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed.
Supply fabricate & fix in position aluminum powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window (two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below complete all as specified and directed. Note: (a) Frame (top & side) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20738) (d) Shutter Interlock Section shall be of size 18.00 x 40.00 x 1.45 mm (Section No 20737). (e) Bottom Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20736) Note:- Section No given above are of make Jindal, Contractor may use similar section of other makes mentioned in Appx 'B' and as aproved by GE.
S&F for Anodised aluminium powder coated (coating of any color, thickness or powder coating not less than 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F for 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F plain, solid, straight chowkats and frames of 2nd class hardwood, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F 125 mm size extruded aluminium alloy, handles, cast type, anodized, complete all as specified and directed.
S&F 150mm aluminium anodised tower bolts of extruded section, complete all as specified and directed.
S&F 100 mm size Stainless steel butt hinges medium weight, fixed to chowkhat complete all as specified and directed.
S&F for 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 30 mm thick factory made second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass / gauge, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkhats complete all as specified and directed.
S&F in repair stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples to wooden shutters complete all as specified and directed.
M&L for preparation of new wooden surfaces, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete complete all as specified and directed.
Excavation in trenches in hard / dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth for laying cables in trenches/pole foundation and getting out complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above starting point where directed.
Material & Labour for Sand Cushioning to UG cable 40mm wide 15cm and 8cm thick above and below the cable respectively excluding one layer of brick class 'B' (old size) laid flat dry across the cable for protection cover on the top of the sand cushioning complete all as specified and directed. Note : Punned thickness of sand will be measured & paid.
Supply & Fixing in repair GI tubing light grade 40/50 mm bore for cable protection fixed to poles under floor/ground complete with all fittings complete all as specified and directed.
Taking down old unsv reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
Laying only PCC cable cover for LT / HT UG cable, of any description, complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed.
Taking out old/unsv LT cable any size from trenches/duct, stacking at site, checking by megger and carry out repair/replacement of defective cable complete all as specified and directed.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 2.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 16 Sqmm nominal cross sectional area 4.0 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 25 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 35 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and laying in trenches or fixing on poles or passing through pipe or under floors LT PVC sheathed armoured cable 1100 Volts grade 'Heavy duty", XLPE insulated, multistarnded aluminium conductor served with inner sheating of PVC tape armoured with galvanised steel strip/wire or tape and overall PVC sheathed of size 50 Sqmm nominal cross sectional area 3.5 core confirming to IS-7098,1998 (part-I) specification complete all as specified and directed. Note: Excavation, earth work, bricks, sand and pipe protection shall be measured and paid separately.
Supply and fixing / passing through pipe from junction box to street light, 2.5sqmm 1100 volts grade heavy duty cable with PVC insulated multi stranded copper conductor cable flame retardant low smoke & halogen 1100 volt confirming to IS complete all as specified and directed.
M & L for shifting of solar light street pole/LT street pole to a distance not exceeding 50 mtr and erect in true vertical position steel tabular pole, around 15.0 metres long complete all as specified and directed. Work consisting following items under:- Note: (i) PCC foundation & coping, Excavation earth work . (ii) Nut bolt like as existing as required. (iii) hydro crane for shifting the pole (iv) material and labour regarding that work etc.
Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of electric poles, struts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Material & labour for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in foundaiton of stays, bed concrete and coping of poles with and including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
Supply & Fixing Bracket made out of GI light grade pipe of 40/32 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50x6mm and 04 sets of nuts,bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer including dismanting existing old and unserviceable security light complete all as specified and directed.
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and directed.
All as per item No.99 above but using galvanised earth lead wire4.0mm as earthing lead
S&F LED Street Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Street Light fitting 45 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Street Light fitting 90 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Flood Light fitting 120 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
S&F LED Flood Light fitting 210 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
Periodical Maintenance / servicing of 29 Watt Solar street light by carrying out following maintenance / servicing activity for minimum two times (at interval not less than 5 months) all as directed by Engr-in -charge. (a) M&L for top up of battery distilled water and checking of specific gravity.If specific gravity beyond normal value entire qty of distilled water shall be replaced. (b ) Making proper alignment of solar panels facing towards south direction. (c) Cleaning the upper surface of solar panel with glass cleaning solution. (d) Clean the battery terminals and nut/bolts with the help of filling tool, make sure the threads are not affected and nut -bolts are properly tightened and application of petroleum jelly at the terminals of the battery.
S&F in repairs pole mounted junction box ( Street light boxes) weatherproof cabinets IP-65-IK-09 class II with removable chasis and faceplates,lockable door handle, sealable cover, self extinguishing conforms to EN 60439-3, for single phase lighting system, suitable for 6 module with 1 row complete all as specified and directed. Make: Legrand Plexo cat part no. 601996 or equivalent makes as mentioned in Appx 'B' to PS.
S & F in repairs contactor 25A/32 A 4 NO , suitable for 230V AC complete all as specified and directed. Make: Legrand cat part no.412544 or equivalent make as mentioned in Appx 'B' to PS.
S & F in repairs 4 pole power contactor 125A 4NO, suitable for 415V AC complete all as specified and directed. Make: ABB cat part no.1SBL41120R or equivalent make as mentioned in Appx 'B' to PS.
Supply, fix in repair Analog weekly timer Switch of supply voltage 240vAC, 50/60 HZ complete all as specified and directed. Make :- Legrand cat part no.412654 or equivalent make as mentioned in Appx 'B' to PS.
Supply and Fix LED Bollard light fitting 9watt, inbuilt driver mechanism, robustly designed, IP 65/IK10 protection complete with base plate and provision of wire 2.0m copper conductor from fitting to connection point incl taking down old unsv light fitting complete all as specified and directed. Make: Philips City Cube Bollard D cat part no: BCP400LED09 D CW PSU GR S1or equivalent make as mentioned in Appx 'B' to PS.
S & F Exide XP1500 battery 12V/24 V, Range 150-200 Ah heavy duty batteries are made using special hybrid alloy used for DG set confirming to IS 16270 and IS 16046 complete with initial charging suitable for DG set complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal,overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 35/45/90 watt street light fitting/post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair outdoor waterproof metal type pillar light/dome light/gate light modern design type suitable for Primary:220-240 V AC, 50/60Hz for outdoor purpose having already fitted LED fitting inbuit driver 60 watt suitable for home enterance, home gate including taking out old/unsv complete all as specified and directed.
Supply and fix in repair outdoor AVIATION red obstruction warning light having day/night photocell sensor, flashing 20-60 FPM suitable for Primary:220-240 V AC, 50/60Hz having IP 65 rating as per standard IS/IEC 60529:2001 with polycarbonate glass for 360 degree illumination having photocell on/off internally fittedincluding taking out old/unsv complete all as specified and directed.
M&L for point wiring for one light/fan point controlled by one switch with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in existing concealed conduit with all accessories including providing sunk cast pressed steel terminal boxes of suitable size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated Bakelite sheet (HYLUM BRAND) top cover along with copper earth wire PVC insulated & unsheathed multi stranded (FRLS) copper conductor cable of size 1.5sqmm as continuous earth wire connected to common earth and earth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Supply and fix in repair single core multi strandards PVC insulated pure copper cable of size 70 sqmm as per IS stadard suitable for lightening protection having higher current carrying capacity with pure copper insulated by fire retardent and FRLS PVC compund suitable for lightening circuits including taking out old/unsv complete all as specified and directed.
Surface cleaning / dressing by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds in soft loose soil complete all as specified and directed. Note:- This item shall be executed for cleaning of surrounding area of various E&M installation.
Supply and fix in repair three phase electric driven induction motor of 1.5 HP(1.1 kw) suitsable for, 415 volt, 50 Hz, , 1415 RPM as per IP 55 rating having efficiency class IE2,4 pole foot mounted for amb 50 degree suitable fo high mast chain mechanism, including fitting and testing complete all as specified and directed.
supply and fix in repair reverse forward switch (starter) 3 phase 32 amp suitable for 415 V ac,50 hz which is used for high ,mast panel induction motor to make or break operational in sequencial way by rotating the switch in different positions including fitting and testing complete all as per direction of Engr in Charge.
Periodical Maintenance / servicing of high mast chain mechanism system by carrying out following maintenance / servicing activity for minimum two times (at interval not less than 5 months) all as directed by Engr-in -charge. (a) M&L in repair fo rproper lubrication( oiling and greasing )of doble drum winch having its load capacity of 750 kg and removal and refixing of motor in high mast pole. (b ) Making proper alignment of three phase induction motor chain with winch ans also balancing of load at the head of high mast pole and proper check the wire connection of each flood light by taking down. (c) Cleaning the upper surface motor,chain mechanism of high mast pole by clean cloth.
S&F in repair MCCB 25 to100 Amps, 3 pole, breaking capacity 16 kA, fixed type fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 250 Amps, 4 pole, breaking capacity 36 kA, fixed type fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 400 Amps, 4 pole, breaking capacity 36 kA, fixed type fixed in existing panel & connecting complete all as specified and directed.
SURESH ELECTRICALS
jagdish machinery stores
Pooja Enterprise
M/s Dhruve Construction
JAMNAGAR ELECTRIC AND MACHINERY CO
suvidhiconstruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .