| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹34.1 L Quoted ₹36.6 L | L1 | Accepted-AOC Acceptance of Tender |
| 2 | L2₹37.7 L+₹1.1 L (2.98%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹37.7 L+₹1.1 L (2.98%) | L2 | Rejected-AOC OK |
| 3 | L3₹37.9 L+₹1.2 L (3.37%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹37.9 L+₹1.2 L (3.37%) | L3 | Rejected-AOC OK |
| 4 | L4₹37.9 L+₹1.3 L (3.54%)Rejected-AOC | ₹37.9 L+₹1.3 L (3.54%) | L4 | Rejected-AOC OK |
| 5 | L5₹41.3 L+₹4.7 L (12.7%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹41.3 L+₹4.7 L (12.7%) | L5 | Rejected-AOC OK |
Tender Value
₹44.9 L
EMD Value
₹90,000
Closing Date
4 May 2024, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF LT UG CABLES LT PANELS FEEDER PILLAR BOX INCLUDING CONNECTED WORKS UNDER GE IMA DEHRADUN
2024_MES_648609_1
GE/IMA/T-18 of 2024-2025 9405/E8
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE IMA Dehradun
Refer NIT
6 documents required · 6 mandatory
₹500
Yes
GE IMA Dehradun
₹90,000
Yes
10 Jun 2024
30 Mar 2024
6 May 2024
31 Mar 2024
4 May 2024
20 Apr 2024
Amount
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/loose soil for laying cable/ taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 Cm thick in soft/loose soil after cables/pipes are laid and tested complete all as directed.
Removing the excavated soil to out side IMA premises and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed.
Material and labour for sand cushioning to under ground cables 8 Cm thick before laying the cable and 15 Cm, thick after laying, stretching and testing the cable complete all as directed. Note: Punned thickness shall be measurement and paid.
Material and labour for un-reinforced precast concrete cable cover LV type I, flat size 250 mm X 150 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed. Make:- Tulip Infrastructure, Jain tiles, NTC Panchkula
Material and labor for brick protection cover (0.23x0.115x0.075m) to undergroung cable with sub class "B" over brunt brick (locally available best quality) laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Material and Labour for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of poles/stays including form work and dismantling of existing PCC complete all as directed.
Material and Labou for cement concrete 1:4:8 type D-2 ( using 40 mm graded crushed stone aggregate) for foundation of pole/stay including form work and dismantling of existing PCC complete all as directed.
S&F double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 50mm outer diameter and 38mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Astral Ltd(Brand-HDPE Pro), RC Plasto Tank & Pipes Ltd,Finolex
S&F double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Astral Ltd(Brand-HDPE Pro), RC Plasto Tank & Pipes Ltd,Finolex
Supply, laying, jointing and testing XLPE insulated, armoured heavy duty under ground electric cable with stranded aluminium conductor 1100 voltage grade including taking out/down old existing unserviceable cable all as directed of following sizes:- Note: Excavation, sand cushioning and bricks shall be measured and paid separately under respective items of BOQ. Make:- Havells,Polycab,Gloster, SCI,Gemscab Ind Ltd.
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm 3.5 core
300 Sqmm one core
Material and labour for galvanised steel tube light grade ISI marked for protection of LT UG cable laid in trench/ under road/drain and floor including FI clamps, nuts, bolts, washers etc all as required at site fixed in repair complete all as directed of following size:-
50 mm bore
50 mm bore
80 mm bore
100 mm bore
Material and Labour for galvanised steel tubes light grade 40 mm bore for bracket of street/security light length 1.20RM including welding, bend to shape and fixed with two nos GI Clamps Size 40x3mm thick including nuts and bolts, washer complete all as directed.
Material and labour for straight through jointing kit heat shrinkable type suitable for 1.1 KV XLPE cable size 25 to 50 sq mm 3.5 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson
Material and labour for straight through jointing kit heat shrinkable type suitable for 1.1 KV XLPE cable size 70 to 150 sq mm 3.5 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson
Material and labour for straight through jointing kit heat shrinkable type suitable for 1.1 KV XLPE cable size 185 to 400 sq mm 3.5 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson.
Material and labour for cable end termination indoor/outdoor heat shrinkable type suitable for 1.1 KV XLPE cable size 25 to 50 sq mm 3.5/4 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson.
Material and labour for cable end termination indoor/outdoor heat shrinkable type suitable for XLPE cable size 70 to 150 sq mm 3.5 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson.
Material and labour for cable end termination indoor/outdoor heat shrinkable type suitable for XLPE cable size 185 to 400 sq mm 3.5 core fixed in repair complete all as directed. Make: M’ Seal, Raychem, Denson.
Material and labour for painting of 9 meter long steel tubular pole complete with one coat of synthetic enamel aluminium paint and preparation of surface including marking of pole Nos with black paint complete all as directed.
Supply and fix in replacement of unserviceable MCCB 630 Amp 4 pole 50 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed.
Supply and fix in replacement of unserviceable MCCB 400 Amp 4 pole 36 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed. Make:-
Supply and fix in replacement of unserviceable MCCB 350 Amp 4 pole 36 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed. Make:-
Supply and fix in replacement of unserviceable MCCB 250 Amp 4 pole 36 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed.
Supply and fix in replacement of unserviceable MCCB 200 Amp 4 pole 36 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed.
Supply and fix in replacement of unserviceable MCCB 160 Amp 4 pole 25 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed. Make:-
Supply and fix in replacement of unserviceable MCCB 125 Amp 4 pole 16 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed.
Supply and fix in replacement of unserviceable MCCB 100 Amp 4 pole 16 KA 415 volts, thermal magnetic release and adjustable overload setting complete all as directed.
Material and labour for graded course aggregate of 20 mm grade nominal size without any vegitation or chemical including levelling/spreading surrounding transformer, HT/LT 2/4 pole structure and LT/HT panel complete all as directed. .
Material and labour for graded course aggregate of 40 mm grade nominal size without any vegitation or chemical including levelling/spreading surrounding transformer, HT/LT 2/4 pole structure and LT/HT panel complete all as directed .
Supply and fixing MS galvanised chain link fencing, of size 4 mm dia and mesh size 100x100 mm to any type of standards, rails, straining bolts etc including provision of binding mix for making fencing around the transformer/ MES installation including taking down/dismantling old chain link fencing/wire mesh complete all as directed
Material and labour for Air termination single pointed at top and properly threaded at bottom end, aluminium rod 12 mm dia and 300 mm long complete all as directed.
Material and labour for Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc.for roof conductors and down conductors above ground fixed in repair complete all as directed.
Supply, installation, commissioning and testing factory made LT panel board uitable for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet (not less than 1.5m x1.5m x .75m) with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable double door type with proper locking arrangements duly finished with using powder coated paint of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - (a) Aluminium bus bar 600 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-400 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) MCCB 415 volts, 4 pole 400 Amps with breaking capacity 36 KA-01 Nos (Incoming). Outgoing:- (a) MCCB 415 volts, 4 pole 160 Amps with breaking capacity 36 KA – 03 Nos. Make:-
Material and labour for bus bar chamber, outdoor type, pedestal type of size 75 cm x 60 cm x 50 cm out door dust and vermin proof front opening made out of 3.15 mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 300 Amp fixed on insulators and one MCCB FP 200 Amp, 25 KA rupturing capacity including necessary angle iron legs fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete all as directed.
Material and labour for painting of LT panel outdoor/indoor off sizes removing existing old paint with the help of sand/emery paper etc. Preparing surfaces externally including cleaning etc. Applying externally one coat synthetic enamel paint including cleaning and surface dressing upto 25 cm depth around 1 mtr of the panels complete all as directed.
Material and labour for painting of LT bus bar chamber off sizes removing existing old paint with the help of sand/emery paper etc. Preparing surfaces externally including cleaning etc. Applying externally one coat synthetic enamel paint including cleaning and surface dressing upto 25 cm depth around 1 mtr of the panels complete all as directed.
Supply and fix in replacement of unserviceable ACB 1250 Amp 4 pole, Ics=Icw= 50 KA manual drawout type with microprocessor release with overload short circuit, ground fault, neutral fault and intantenous protection (LSING) conforms to IEC 60947/iS13947 (Part 1 & 2 ACB shall have LCD display with battery back up of suitable capacity to diagnose the type of fault with stamping of time, date and minimum 10 Nos fault history complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 50 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 70 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 95 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 120 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 150 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 185 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 240 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 300 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 400 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 500 sqmm complete all as specified and directed.
Supply and fix in replacement of aluminium lugs of size 630 sqmm complete all as specified and directed.
Material and labour in replacement of existing unserviceable danger notice board with pressed vitreous painted plate fabricated out out of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size LT 1.1 KV 20 X 15 cm size complete all as directed.
Earthing complete for machinery equipment installed at power house/sub station with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40 mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6 mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10 mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) 40 mm thick cover, reinforced with 8 mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40 mm dia GI light grade earth lead protection pipe etc complete all as per electrical plate No. 03 of SSR Part-l (2009) and as specified and directed. Note: (i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth lead & protection pipe, if any, required at site shall be measured and paid for separately under appropriate item of BOQ. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32 X 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I (2009) and directed.
Supply and fix LED street light fitting 70 watt energy saving and enviromental friendly long liife made up of pressure die cast aluminium housing with high power LED as lightnig source and lens embedded PC cover having top opening seprate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device suitable for pole dia 54 mm (max) including taking down existing fitting of any type and in any position complete all as directed.
Supply and fixing LT cable root indicator of cast iron embedded in PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) of size 100x100x200 mm foundation upto ground level including necessary earth work in any type of soil complete all as specified and directed.
Supply and fix shock proof and rust proof pole mounted junction box of size 140mm x 140mm x 90mm for garden lighting system complete with all accessories and including MCB SP 6 Amp, 100 Amp rated heavy aluminium bus bar mounting on shaddle, 2 terminals, pole clamp with nut bolts etc with necessary mounting arrangement in the junction box with pole all as specifed and directed.Make: Sintex Industries Ltd/ Supreme Industries/ Naithani Plastic Moulding Works.
Material and Labour for steel tubular swaged pole 9 mtr long with MS base plate (450MMx 450MM x6MM) , finial taper plug, bolts, nuts and screws as specified type 410 SP 31, Strainght type / Swan Neck type as required , including painting with anti corrosive paint internally complete and externally complete with two coat of synthetic enamel aluminium paint over a coat of red oxide primer and preparation of surface including marking of pole Nos with black paint complete all as directed. (Note: Excavation/earth work and PCC will be measured and paid seperately.)
Supply and fix LED Post Top light 25 Watt,powder coated die cast aluminium housing PC deffuser efficient high output LED with IP-65 including all fixing arrangement,and elect connections complete all as specified and directed.
Material and Labour for PVC insulqated and FRLS round sheathed, copper conductor 1100 Volts grade Cross section area of size 1.5 Sq mm 3 Core laid in trenches/pole complete all as directed. Make:-
Material and Labour for PVC insulqated and FRLS round sheathed, copper conductor 1100 Volts grade Cross section area of size 2.5 Sqmm 3 Core laid in trenches/pole complete all as directed. Make:SCI/Havells/Polycab/Gemscab/Anchor
M/s Kamal Traders
JS CONSTRUCTION COMPANY
Mani Control System
Deven Associates
KRISHANA ELECTRIC WORKS
PARADISE INFRA POWER COMPANY
KISHORE ENTERPRISES
Shikha Enterprises
Balraj and Co
VIJAY ENTERPRISES
Ravi Electrical
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .