DEPUTY CHIEF ENGINEER ELECTRICAL CIRCLE, NILAMBUR
O/O THE DEPUTY CHIEF ENGINEER ELECTRICAL CIRCLE, VYDUTHI BHAVANAM, NILAMBUR , MALAPPURAM (DIST) KERALA-679329
Development of Distribution Infrastructure on Turnkey Basis under Dyuthi Special Scheme for Supply and Installation of HT ABC and Transformers at various locations under Electrical Circle, Nilambur.
2025_KSEB_824433_1
EC/NBR/Dyuthi special/E-TENDER NO 04/25-26/DTD 29.12.2025(Re-Tender)
Open Tender
Electrical Works
Item Rate
180 days
NILAMBUR
Please refer tender documents
5 documents required · 5 mandatory
₹8,850
₹1 L
ELECTRICAL CIRCLE NILAMBUR
8 Apr 2026
5 Jan 2026
21 Jan 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
9 Jan 2026
Aerial Bunched Cable HT 3x120 + 1x95 sq.mm (Insulated Messenger)
Air Break Switch (AB Switch) 11kV 400 A , Composite Polymer Housing
Channel Cross arm GI - LT 2 Line 75 x 40 mm (2 line Channel Cross arm)
GI WIRE 6MM DIA 4 SWG
Bolt & Nut GI FT M 12 x 150 (6"x 1/2")
BOLT & NUT GI HT 200mm x 19mm
Bolt& Nut GI M 20 x 250 (9 3/4"x3/4")
Channel cross arm GI 75 x 40mm -2.4 mt
Stainless Steel Strap [20 mm x 0.7 mm]
Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm]
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 120 sq.mm
Pole PSC 9 M
CLAMP GI FOR HT CROSS ARM
Heat Shrinkable Termination Kit (3 Nos) for 120 Sq.mm Three phase Aerial Bunched Cable
Cable Tie UV Plastic Heavy Duty 500 mm Length
MVT Kit for HT ABC (3 Nos)
Clamp GI For HT Stay/Strut
Bolt& Nut GI M 12 x 65 (2 1/2"x 1/2")
Clamp GI For 9 mt Strut Pole (For Strut)
G.I.WIRE. 4MM (8 SWG)
Pipe GI 40 mm dia -2.5 m Length( Earth Pipe)
Earth Chamber (PVC) With RCC Covering Slab
Earth Connector 95 Sqmm
Bolt & Nut GI M 16 x 40 (1 1/2"x 5/8")
Crimping Socket Palm Type 50 Sq.mm -Al(Cable Lug)
Suspension Clamp Assembly for HT AB Cables up to 120 sq.mm
Distribution Transformer 11kV/ 433 V 100 kVA 3 phase ONAN
Crimping Socket Palm Type 120 Sq.mm -Al (Cable Lug)
Crimping Socket Palm Type 95 Sq.mm -Al (Cable Lug)
Hardware Fittings 11kV B&S Type
Disc Insulator 11 kV Composite Polymeric
Channel cross arm GI 75x40 mm- 1.8 M
CROSS ARM GI CHANNEL 100X50 mm 3 M
V cross arm -GI -11 kV
Cleat GI for 11kV Disc insulator
Earth Clamp GI 40 mm Dia
FUSE UNIT 415 V 200A PORCELAIN
FUSE DROP OUT 11 kV
Lightning Arrester 11kV Polymeric insulator without Structure
Fuse Wire 200A
BOLT & NUT GI 40mm x 16mm (1 1/2 x 5/8)
Bolt& Nut GI FT M 16 x 75
BOLT & NUT GI HT 300mm x 19mm
Cable 1.1kV XLPE AL 1c X 120 sq mm (Un Armoured)
COMPOSITE PIN INSULATOR 11 kV with Pin
Pole A Type GI 11 M
Distribution Box LT Outdoor 2 Way 200 A
Channel Cross arm for LT 4 Pin -GI 75 x 40 x 6 mm 1.11 mt (4 Line Cross arm)
Clamp GI for LT 2/4 Line Cross arm
Stay Insulator Porcelain 11k V
STAY TIGHTNER HT
Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)
Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod)
Helically formed Guy-Grip HT
Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI))
Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)
Earthing Coil GI 115 Turns 50 mm internal Dia dia
Ferrules 5 Sq.mm(GI)
LIGHTNING ARRESTOR 9 kV 5 KA COMPOSITE TYPE
Distribution Box LT Outdoor 2 Way -415 v, 200 A-With Aluminium Main Busbar 40 x 10 mm and Aluminium Inter connecting Bus bar 30 x 6 mm (Without Fuse Unit) FRP-With CBN( Dimension 800x800x275 mm)
MVT Kit For HT ABC
Clamp for HT Cross arm
Anchoring /Dead end Clamp Assembly for HT AB Cables up to 150 sq.mm (Insulated messanger 95 to 120 sq mm)
Channel cross arm with CBN -GI 75 x 40 x 6 mm 2.4 mt
Suspension Clamp Assembly for HT AB Cables up to 150 sq.mm
CROSS ARM GI CHANNEL 4 LINE(4 Line channel cross arm) for PSC Poles 8M/200kg
SHACKLE INSULATOR 415V SET(WITH STRAP BOLT&NUT)
PIN INSULATOR 415V SET(WITH PIN)
FUSE UNIT 415 V 300A PORCELAIN
Stainless Steel Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm.
Stainless Steel Strap 10 mm x 0.7 mm-For clamping earth wire
Clamp for 1.8m/2.4 Channel cross arm (MSC 75X 40)
Clamp GI for V cross arm
Plate washer GI M16
Bolt& Nut GI M 12 x 90 (3 1/2"x 1/2")
Copper Flat Strip 40 x 3 mm length 115mm
GI Flat Strip 40 x 6 mm
Conductor ACSR Rabbit
EARTH WIRE 7/3.66 mm or 7/9
Bolt & Nut GI M 10 x 25 (1"x 3/8")
Bolt & Nut GI M 6 x 25 (1"x 1/4")
Helically Formed Fitting -Distribution Top Tie for ACSR Raccoon
LA Supporting Plate GI 500 x 300 x 3 mm
Angle cross arm GI 35 x 35 x 6 mm 0.5 mt
Clamp GI for Cable Tray in Transformer DP
Clamp GI for 2/4 line channel Cross Arm for PSC Poles 200kg
CROSS ARM GI CHANNEL 2 LINE(2 Line channel cross arm) for PSC Poles 8M/200kg
Bolt & Nut GI M 12 x 160 (6 1/2"x 1/2")
PIN INSULATOR 415/240 V Porcelain
Clamp GI For Transformer Side Belting Angle
Square Washer GI M10
GI Flat Strip 25 x 3 mm
Heat Shrinkable Termination Kit (3 Nos) for 120 Sq.mm Three phase HT Aerial Bunched Cable
Cable 1.1kV PVC Insulated AL Twin Core 2.5 Sq.mm PVC Sheathed Weather Proof (TC Weather Proof Wire 1/1.8)
POLE A TYPE 12 M
Clamp MS for 2/4 line channel Cross Arm for PSC Poles 200kg
GI Wire 4 SWG
Bolt & Nut GI M 8 x 20 (3/4"x 5/8")
Bolt& Nut GI M 12 x 100 (4"x 1/2")
Bolt& Nut SS M 20 x 205 (8"x3/4")
Bolt& Nut GI M 20 x 255 (10"x3/4")
Bolt& Nut GI M 20 x 355 (14"x3/4")
Bolt& Nut GI M 20 x 305(12"x 3/4")
Cable 1.1kV XLPE AL 1c X 95 sq mm (Un Armoured)
Conductor ACSR Raccoon
Aerial Bunched Cable HT 3x150 + 1x120 sq.mm (Insulated Messenger)
End Termination Kit (3 Nos) Heat Shrinkable -for HT ABC 150 Sq.mm
Bolt& Nut GI M 16 x 75 (3"x 5/8")
Turn Buckle ,Eye bolt with 2 Nuts 20 mm dia -GI(Stay tightner HT)
Bolt& Nut GI FT M 12 x 50 (2"x 1/2")
CT RESIN CAST 0.415KV 10VA Class 0.5 200/5A
EM 3X 230V CLASS 0.5S --/5A LCD(DTR /LT CT METER)
Meter Box For Distribution Transformer With Clamps (FRP)
Clamp GI for Danger Board (HT)
POLE A TYPE 11 M
Channel cross arm GI 100 x 50 x 6 mm 2.4 mt
Channel cross arm GI 100 x 50 x 6 mm - 3 mt
CROSS ARM GI CHANNEL 4 LINE (4 Line Channel Cross Arm) with Clamp, Bolt & Nut for PSC Pole 8M/200kg
Channel cross arm GI -LT 4 Line 75 x 40 mm- (4 line Channel Cross arm)
Cable Tray GI (Perforated) 300 x 30 x 1.6mm-2.5 mt
Cable Tray GI 300mmX1.6 mm
Plate Washer SS M12
Spacer LT 4 line Composit (For Cable Tray)
Distribution Box LT Outdoor 3 Way -415 v, 200 A-With Aluminium Main Busbar 40 x10 mm and Aluminium Inter connecting Bus bar 25x10 mm (without fuse unit) Stainless Steel Sheet Shell 18 Guage-With CBN
Pole Top Bracket -F Type GI -11 kV
Danger Board 250 x 200 mm (11000 V)
Channel cross arm -75x40x6mm 1.8M
Shackle Insulator Porcelain 415/240 V
Bolt& Nut SS M 12 x 100 (4"x 1/2")
Earth Connector 150sq.mm
Cable Tie UV Plastic Heavy Duty 250 mm Length
Pin Insulator 11kV Composite Polymeric
MVT Kit for HT ABC (1 No.)
Cable tray GI 300x40 mm
Drop Out Fuse 11kV 100A (Polymeric)
Bolt& Nut Brass with 2 plate washers - M 10 x 40 (1 1/2"x 3/8")
Bolt& Nut GI FT M 12 x 200 (8"x 1/2")
Bolt& Nut GI M 20 x 150 (6"x3/4")
Bolt& Nut GI M20 x205(8"x3/4")
Clamp GI for HT Cantiliver Cross arm (50 x 8 x 276 mm)
CT RESIN CAST 0.415kV 5VA Class 0.5S 100/5A
Fish Plate GI (GI Flat 260 x 50 x 8 mm)
Clamp for 3m channel cross arm (MSC 100X50)
BOLT & NUT STAINLESS STEEL(2 1/2 X 3/8)
Bolt& Nut Brass M 16 x 40 (1 1/2"x 5/8")
Bolt& Nut GI M 20 x 200 (7 3/4"x 3/4")
Bolt& Nut GI M 20 x 225 (8 3/4"x3/4")
Anchor/Dead End Clamp for insulated messenger for AB Cables 120 sqmm
Stainless Steel Strap 20 mm x 0.7 mm
Stainless Steel Buckle Slot width 20.5 mm x 1.5 mm,Thickness 1.2 mm.
Bolt & Nut Brass M 12 x 50 (2"x 1/2")
Transformer Belting Angle-65 x 65 x 6 mm -3 mt - GI
End Termination Kit HT ABC 3c x 120 Sq mm
Pre- Insulated Crimping Socket Palm Type 50 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 16 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 70 Sq.mm -Bimetallic (For ABC)
Distribution Box LT Outdoor 3 Way 200 A
CLAMP GI FOR HT STAY WITH BOLT and NUT SET
V CROSS ARM GI SET(WITH CLAMP BOLT&NUT)
Bolt& Nut GI M 20 x 300(11 3/4"x 3/4")
Bolt& Nut GI M 12 x 305(12"x 1/2")
End Termination Kit HT ABC 1c x 120 Sq.mm
Item Wise BoQ
BoQ_Ver3.0
Re-Tender No: EC/Nilambur/Dyuthi Special/Etender No.04/ 2025-26 dated 29.12.2025 (ID_2025_KSEB_824433_1)
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with bare/insulated Messenger through existing poles
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
Fitting one set AB switch and giving connection
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
Drilling hole of various sizes on existing Channel/Cross Arm.
Erection of Anchor clamp / dead end clamp for 11kV ABC of any size
Fitting and erecting one HT DP using PSC pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Fiting One no MVT on existing cross arm including 2 nos end termination (for One phase) of any rating for 11 kV AB Cable
Fitting and erecting one HT PSC Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
Fitting and erecting one HT A type Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle).
Transferring LT 3ph 4/5 wire OH line to newly erected HT/LT pole and refitting all items to the new pole.
Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification).
Fitting and providing one Strut using HT PSC pole incl. digging & back filling pit.
Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling.
Erection of suspension clamp for 11KV ABC of any size
Erecting one 100kVA Transformer to existing DP and giving connections, incl. loading & unloading, excluding transportation.
Transporting Transformers by hired vehicle upto 5km and upto 2 No. of 63 to 250kVA Transformers / RMUs excluding loading & unloading.
Additional rate for providing one disc set on any type of HT pole for making cut point.
Fitting and erecting one HT DP using A type pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
Fitting 5 channel cross arms, AB switch, DO fuse, LA, HT & LT connections on existing DP, 3 LT fuses.
Fitting one Additional V cross arm in existing single pole incl. conveyance of materials.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.
Additional rate for excavation of Pit for A type pole in Laterite.
Additional rate for excavation of one Earth Pit (2.5m depth) in Laterite.
Fitting one additional Fuse unit and giving connection from Transformer to fuse and DB to LT OH line.
Erection of LT 2 way distribution box on existing cross arm giving connection incl. cable and earth connection (excluding earthing).
Fitting one LT 4 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
Additional rate for refitting/redoing one Shackle set and reshackling one span while renewing any type of pole.
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion.
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Providing additional HT stay insulator in existing stay.
Fitting 6 channel cross arms, AB switch, DO fuse, LA, HT & LT connections on existing DP, 3 LT fuses.
Renewal of existing damaged/old 11kV PSC/RCC Pole with new A type pole in place and refitting of all items incl. conveyance (except pole).
Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials.
Transferring LT Sph 2/3 wire OH line to newly erected HT/LT pole and refitting all items to the new pole.
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting.
Dismantling (without damage) one 11kV A type pole after disconnecting stays, strut etc. and stacking the same.
Providing one Earth using earth pipe incl. digging & backfilling pit and supply of charcoal, salt, sand etc.
Fiting One no MVT on existing cross arm excluding termination work (for One phase) of any rating for 11 kV AB Cable
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm
Providing Transformer fencing , using 50x50x6mm Angle iron, 40 x 6 mm MS flat and 8 mm MS rod as specified, incl cost of transportation & foundation
Providing yard metalling with 6mm & 40mm thick blue metal as specified after constructing a curb wall.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole incl. digging & back filling pits.
Fitting and erecting 9M PSC pole with out V cross arm,pin insulator and f clamp for AB Cable stringing
Fitting and erecting A type pole without using cross arm, insulators and F clamp for stringing AB cable.
Conveyance of one km 11kV line materials from section store/stacking place to the work site (excluding poles).
Dismantling (without damage) LT stay incl. digging pit in all classes of soil and backfilling
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Providing spiral earthing
Drilling oval shaped hole of various sizes on existing Channel/Cross Arm/GI/MS cleat etc.
Providing Cable Tie
Stringing one km LT 3ph 4 wire line (Rabbit for Ph, Weasel for N) incl. fitting cross arm etc. removing touchings and conveyance of materials.
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
Providing Stay for LT poles incl. digging & back filling pit.
Erecting one LT PSC Pole in position incl. digging & back filling pit.
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Reshackling one span LT Sph 2 wire OH line, replacing insulators, tightening stay, cutting tree branches incl. conveyance.
Reshackling one span LT 3ph 4 wire OH line, replacing insulators, tightening stay, cutting tree branches incl. conveyance.
Fitting one additional HT pin with insulator
Installing one DTR Meter with box on existing poles and giving the complete connections incl. conveyance of materials.
Dismantling one damaged 11kV PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Fitting one set (3No.) 11kV LA and giving connections excluding earthing.
Fitting and providing one HT Fly stay for 11kV pole using A type pole incl. digging & back filling pits.
Providing spiral earthing
Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite.
Stringing of 11 kV Aerial bunched cable of size 3 x 150 + 1 x 120 sqmm with bare/insulated Messenger through existing poles
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Stringing one km LT Sph 2 wire line (Rabbit) incl. fitting cross arm etc. removing touchings and conveyance of materials.
Dismantling (without damage) one LT PSC/RCC Strut pole incl. removal of clamps and stacking.
Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt&nut etc.
Fitting and erecting 9 Meter PSC Pole without using V cross arm, insulators and F clamp for stringing ABCable
Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane
Stringing one km LT Sph 3 wire line (Rabbit for Ph&N, Weasel for St.main) incl. fitting cross arm etc. removing touchings and conveyance of materials.
Erection of LT 3 way distribution box on existing cross arm giving connection incl. cable and earth connection (excluding earthing).
Loading HT A type pole to Hand cart from the stacking place and unloading the same at work site.
Fitting one set AB switch, DO fuse, LA, giving connections and drawing earth leads for earthing excluding provision of earth.
Dismantling (without damage) one HT PSC/RCC Strut pole incl. removal of clamps and stacking.
Dismantling one section fuse
Dismantling (without damage) one km 11kV line (3 conductors), cross arm, insulators, disc, rolling the conductor and stacking.
Fitting one LT 2 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
Dismantling one LT 2 line cross arm from existing pole.
Fitting one Additional 2.4m Channel cross arm in existing single pole incl. conveyance of materials.
Dismantling one Channel cross arm from existing DP structure, and bringing back to section store.
Dismantling one V cross arm/Channel cross arm from existing Pole, and bringing back to section store.
Dismantling one set(3No) 11kV LA
Dismantling (without damage) one AB switch from existing structure and bringing back to section store.
Dismantling one Anchor clamp /dead end clamp from 11 KV ABC
Dismantling one suspension clamp from 11 KV ABC
Dismantling of 11 kV Aerial bunched cable XLPE insulated of size 3 x 120+ 1 x 95 sqmm with bare insulated Messenger
Replacing/inserting HT Stay insulator on the existing stay.
Fitting one No. LT lightning arrestor in LT OH line and giving connections excluding earthing.
Fitting one Additional 2.4m/3m Channel cross arm (75x40x6mm), in existing 11kV DP incl. conveyance of materials.
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Insertion of one HT PSC pole in existing HT/LT line incl. digging & back filling pit, fitting cross arm, insulator, binding etc.
Item Rate BoQ
BoQ_Ver3.0
Re-Tender No: EC/Nilambur/Dyuthi Special/Etender No.04/ 2025-26 dated 29.12.2025 (ID_2025_KSEB_824433_1)
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
TOTAL BOQ1 (Materials( Total Ex-work price of Materials + Total Transportation cost ) excluding GST.)
TOTAL BOQ2 (Installation / Erection Charges (Excluding GST)
TOTAL AMOUNT [1+2] (Excluding GST)
Discount offerred by Bidder(If any)
BOQ 3: TOTAL excluding GST [3 - 4]
Grand Total (5+ Total Amount of BOQ1+GST Amount of BOQ2 )
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.36 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.70 MB
Vol2A.pdf
Tender Documents • 1.00 MB
BOQ_1383957.xls
BOQ • 0.43 MB
Vol2B.pdf
Tender Documents • 3.73 MB
Vol3.pdf
Tender Documents • 1.00 MB
Vol1.pdf
Tender Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .