Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 CrAccepted-AOC 17E COLLECTOR OFFICE ROAD VENKATHESAPURAM SUNDAR NAGAR EXTENSION NEAR DIC PERAMBALUR 621 212 | PERAMBALUR | TAMIL NADU | 621212 | ₹17.7 Cr Quoted ₹17.9 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹18.3 CrRejected-Finance COIMBATORE TAMIL NADU 18 | 18 | ₹18.3 Cr | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹19.7 CrRejected-Finance E 30 2ND FLOOR 2ND AVENUE BESANT NAGAR CHENNAI 600 090 | CHENNAI | TAMIL NADU | 600090 | ₹19.7 Cr | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹17.7 Cr
EMD Value
₹8.9 L
Closing Date
7 Feb 2026, 11:00 amClosed
Thiru.J.ELAMVAZHUTHI B.E Superintending engineer
O/o the SUPERINTENDING ENGINEER,H C AND M, TVS TOLLGATE, TIRUCHIRAPPALLI 20.
Widening from Two Lane with Paved Shoulders to Four Lane and Strengthening at Km 5/2-9/075 of Perambalur Byepass Road including Widening of Box culverts,Construction of Retaining wall, Junction Improvements and Construction of Centre median(SHU-182)
2026_HWAY_645503_1
TN.NO.43/2025-26/PERAMBALUR
Open Tender
Civil Works - Roads
300 days
PERAMBALUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹0
₹8.9 L
26 Feb 2026
22 Jan 2026
7 Feb 2026
22 Jan 2026
7 Feb 2026
23 Jan 2026
Road Work
Earthwork excavation in all classes of soils except hard rock requiring blasting and depositing on bank with all leads and lifts as per SS20B including cost of all labour charges, materials, tools, equipments and all incidental charges, removal of other deleterious matter and obstructions, trimming of bottom of excavation back filling, clearing up the site and disposal of all surplus materials etc., complete Box Cutting for Widening portion as per MoRTH Rev V standard specification 100,111,112,305
Main work
Junction Improvements
COMPACTION FOR UTILIZING AVAILABLE BOX CUT EARTH Providing compaction for making up of low berms using the available box cut earth including all hire and fuel charges for power roller for compaction, water sprinkler, including all labour charges for laying, spreading, watering etc., complete and as directed by the departmental engineer as per MoRTH Rev-5 specification
Main work
Earthwork excavation in all classes of soils except hard rock requiring blasting and depositing on bank with all leads and lifts as per SS20B including cost of all labour charges, materials, tools, equipments and all incidental charges, including compacting with vibratory soil compactor, watering, including all hire and fuel charges for all tools and plants, removal of other deleterious matter and obstructions, trimming of bottom of excavation back filling, clearing up the site and disposal of all surplus materials etc., complete as per standard specification. For formation of embankmentusing conveyed earth ( CBR not less than 8) with an average lead of 9 Km as per MoRTH Rev V standard specification 100,111,112,305
Main work
GRANULAR SUB BASE Grade -V Providing, laying, spreading and compacting graded stone aggregates for Granular Sub Base, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using motor grader in Sub Base course on well prepared surface and compacting with vibratory soil compactor to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 401 of MORTH Rev-5 ( Grade V)
Main work
Junction Improvements
GRANULAR SUB BASE Grade -III Providing, laying, spreading and compacting graded stone aggregates for Granular Sub Base, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using motor grader in Sub Base course on well prepared surface and compacting with vibratory soil compactor to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 401 of MORTH Rev-5 ( Grade III)
Main work
Providing, laying, spreading and compacting graded stone aggregates for Wet Mix Macadam 250mm thick, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using motor grader in Sub Base/ Base course on well prepared surface and compacting with vibratory soil compactor to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Main work
Junction Improvements
Providing and laying Prime Coat over WMM surface using 7 Kg of Emulsion Bitumen (SS1) per 10 sqm for preparatory to another bituminous construction over it, spraying with pressure distributor including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 502 of MORTH Rev-5
Main work
Junction Improvements
Providing and laying Tack Coat over WMM surface (treated with primer) using 2.50 Kg of Bitumen Emulsion (RS1) per 10 sqm for preparatory to another bituminous construction over it spraying with pressure distributor including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as as per Clause 503 of MORTH Rev-5
Main work
Junction Improvements
Providing and laying Tack Coat over Existing BT surface using 2 Kg of Bitumen Emulsion (RS1) per 10 sqm for preparatory to another bituminous construction over it spraying with pressure distributor including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as perClause 503 of MORTH Rev-5
Main work
Junction Improvements
DBM (Grade-I) 75mm Thick Using VG30 Bitumen Providing, laying 75mm consolidated thick Dense Bituminous Macadam using 0.40cum of 37.50-13.20mm, 0.35cum of 13.20-2.36mm and 0.36cum of 2.36mm & below size IRC metal with 71.30kgs of VG30 grade bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen, aggregate and mixing them in the required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to site, spreading the mix to uniform thickness of 75mm with mechanical paver to the specified grades and cross sections and consolidated by Vibratory Roller to the required density etc., including labour for attending to paver to site etc., including hire and fuel charges for 20-30t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including all other incidental charges etc., complete as per specification using CMP as per clause 505 of MORTH rev-5
Main work
BM (Grade-II ) 50 mm thick using VG 30 Providing, laying 50mm consolidated thick Bituminous Macadam using 0.20cum of 26.50- 13.20mm, 0.43cum of 13.20-2.36mm and 0.08cum of 2.36mm & below size IRC metal with 37 Kgs of VG30 Grade bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen, aggregate and mixing them in required temperature using Central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory Roller to the required density etc., including labour for attending to paver to site etc., including hire and fuel charges for 20-30t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including all other incidental charges etc., complete as per specification using CMP as per clause 504 of MORTH Rev-5
Main work
Junction Improvements
BC 30/40mm Thick (Grade-II) Using VG30 Bitumen (more than 5m Paver) Providing and laying Bituminous Concrete to 30/40mm thick using 0.13 cum of 19.00-9.50mm, 0.17 cum of 9.50-2.36mm and 0.26 cum of 2.36 and below with 50.30kgs of VG30 bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, hydrostatic paver finisher (more than 5m width), Vibratory Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Main work
Junction Improvements
BOX CULVERT
Dismantling Culverts/bridges and other structures Dismantling, salvaging and removal and disposing of resulting materials and back filling the resulting trenches and pits etc.including cost of all labourand machinery and all incidental charges complying with MORTH Rev-5. specification. a)Dismantling Plain Cement Concrete MORTH 111 112 202
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Earth work excavation in all classes of soils except hard rock requiring blasting and depositing on bank with all lead and lift as per SS20B including cost of all labour, materials, tools, equipments and all incidental charges and sheeting, shoring, bracing and their subsequent removal, removal of all logs, stumps and other deleterious matter and obstructions, trimming of bottom of excavtion backfilling, and clearing the site and disposal of all surplus materials etc. complete as per standard specification for Box Culvert as per Cl.111, 112, 201, 304 and 900 of MORTH Rev-5.
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Cement Concrete of grade M15 using 40mm ISS size HBG graded metal using with M-sand including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labor charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants and maintaining of protective bunds, cofferdams, shoring, strutting etc., complete as per relevant standard specifications, for LEVELLING COURSE BELOW Box Culvert / Wing wall as per MORTH Vth Rev., 1000, 1500, 1700, 2100 & 900.
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Vibrated Reinforced Cement Concrete of grade M25 (Design mix) using 20mm and below ISS graded hard broken granite metal using with M-Sand, including cost and conveyance of all materials to site and cost of cement excluding cost and fabrication of steel but including cost of form work, labour charges for mixing, transporting, laying and curing concrete, working at depth, hire charges for tools and plants including all other incidental charges etc., complete as per relevant standard specifications as directed by the Engineer for Box culvert as per MORTH No. 100, 900, 1000, 1500, 1600, 1700, 2200, 2300
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Supply and fabrication of Steel Grade Fe500/Fe500D and Fe550/Fe550D required for all RCC items of works involved in the schedule of drawings including cost of steel, cost of fabrication, labour charges for cleaning the bars straightening, cutting, bending, tying grills, positioning and placing the reinforcement in position as specified in the drawings including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete as per standard specification. - MORTH Vth Rev., 1000, 1600 & 900
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Vibrated Cement Concrete M 20 mix(Nominal mix)using 40mm ISS size hard broken granite metal and with M-sand including cost and conveyance of all materials from approved quarry to worksite including cost of cement including cost and labour charges for formwork and centering mixing the concrete, transporting, laying, vibrating, compacting, curing with all leads for soft potable water, working in all depths including hire, running and fuel charges for all tools and plants employed and in accordance with standard specification for Wing wall & Parapetas per MORTH Vth Rev., 1000, 1500, 1700, 2100,2200
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Vibrated reinforced cement Concrete M30 grade design mix using ISS size HBG graded metal and using M.sand including cost and conveyance of all materials to worksite and cement excluding cost and fabrication of steel including all labour charges for mixing concrete, laying, vibrating, hire charges for tools and plants, compacting, curing with all leads for soft water, including all other incidental charges,formwork,cost of premoulded expansion joints and fixing the same in position etc., complete for wearing coat of 75mm uniform thickness over deck slab and approach slab as per section 2702 of MORTH specification (Rev- V)
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Providing FILTER MEDIA behind abutments and return walls for 600mm thickness using filter material conforming to clause 309.3.2.B of MORTH specification (Rev- V) well packed with smaller size towards the soil and bigger size towards the wall including cost and conveyance of all materials to worksite and including labour charges and all other incidental charges etc., complete.
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Filling behind Abutments and return walls with clean gritty free draining gravel including cost of gravel having P.I value less than 6, conveyance of gravel to worksite. Laying, handling charges and filling in layers tamping under optimum moiture content to get the maximum density, including watering, with all leads and lifts for water and all other incidental charges etc., complete. Complying with relevant standard specification.
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
Providing and fixing Class I PVC seepage pipes of 110mm dia of required lengths for abutments and return walls including costs and conveyance of all materials to work site and labour charges for fixing etc., complete to drain from the backfill as per section 2706 of MORTH specification (Rev- V)
Widening of Box culvert at Km 5/4
Widening of Box culvert at Km 5/8
Widening of Box culvert at Km 5/10 (i)
Widening of Box culvert at Km 5/10 (ii)
Widening of Box culvert at Km 6/4
Widening of Box culvert at Km 6/6
Widening of Box culvert at Km 6/10
Widening of Box culvert at Km 7/2 (i)
Widening of Box culvert at Km 7/2 (ii)
Widening of Box culvert at Km 7/6
Widening of Box culvert at Km 8/2
Widening of Box culvert at Km 8/6
KERB TYPE CENTRE MEDIAN
Providing Kerb Type median / islands using vibrated cement concrete of grade M20 (1:1.5:3) using 20 and 12 mm ISS HBG metal and M.sand from approved quarry, including cost and conveyance of all materials to work site, including hire and fuel charges of all the machineries employed for this work, including all labour charges for mixing, laying, curing, painting, including all other incidental charges etc., complete as per drawing and standard specification.
Filling with conveyed earth in between kerb stones ( with an average lead of 9 Km) in layers not exceeding limits including watering consolidation including all labour charges and incidental charges etc., complete as directed by the Engineer as per MORTH Vth Rev.111, 112, 301, 304, 305, 2907.
ROAD FURNITURE
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35- 2015. The finished surface to be level, uniform and free from streaks and holes etc., complete as per MoRT&H specification No.803
RF At Km 5/2- 9/075
Road Markers/Road Stud with Lens Reflector Providing and fixing reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate / methyl methercrylate/ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280. The reflective raised pavement markers shall also confirm to the MoRT&H circular No RW / NH. 33023/10/ 97-DO. III dt 11.06.97. The height, width and length shall not be less than 15 mm, 90 mm and 100 mm and with minimum reflective area of 13 Sq.cm on each side and the slope to the base shall be 35 (+/-) 5 degree. Each reflector shall have a CIL not less than values specified in Table 2 of said MoRT&H circular. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 (+/-) 2mm and height not less than 30 (+/-) 2 mm) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the Engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35 - 2015 guidelines and MoRT&H specification 804 etc., complete
RF At Km 5/2- 9/075
Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801) (60 cm cirular board)
RF At Km 5/2- 9/075
Providing and erecting of Direction and Place Identification Retro-reflectorised Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer- in charge. High intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801)(for sign having area upto 0.9 sqm) (Type-IV)
RF At Km 5/2- 9/075
Providing and erecting of Direction and Place Identification Retro-reflectorised Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer- in charge. High intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801)(for sign having area more than 0.9 sqm) (Type-IV)
RF At Km 5/2- 9/075
Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro -Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801) 90 cm equilateral triangle
RF At Km 5/2- 9/075
Providing and Erecting of Retro - Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro reflection as per Table 6.6 of IRC 67-2022. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801) 30cm x 90cm rectangular
RF At Km 5/2- 9/075
Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801)90cm Octagon
RF At Km 5/2- 9/075
Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H Specification No.801) 80x60 cm rectangular
RF At Km 5/2- 9/075
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery -1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation, pole painting including transportation charges, installation charges etc., complete as per standard specification.
RF At Km 5/2- 9/075
Metal Beam Crash Barrier Type - A, “W” Double Guard. Providing and erecting Single sided Double Guard Metal Beam Crash Barrier System 1.70m high, comprising of 3mm thick wall “W” beams posts and spacer channels shall be made by cold roll forming using HR conform to IS 5986 Fe 410/360 and dip galvanized having Zinc Mass of 550gms/ sqm, minimum 950mm above road/ ground level fixed on ISMC series channel vertical post 150x75x5mm spaced 2m center to center 312mm x 83mm flange width x 3mm thick, 4318mm long post directly embedded in the concrete (M15) pit size 350x350x800mm for a depth of 750mm below ground. All fixing bolts and nuts hot dip galvanized conforming to IS:1367 clause 4.60 all complete as per Technical Specification and as directed by the Engineer-in-charge
RF At Km 5/2- 9/075
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign Board made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC 67 - 2022 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retroreflection values against the values as mentioned in Table 6.9 of IRC 67 – 2022. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2022 (As per MoRT&H specification No.801). Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. of size 12.00 m X 1.8 m
RF At Km 5/2- 9/075
Providing and fixing of Digitally Printed Retro Reflectorized Overhead Cantilever nformatory sign Board of Size 5.00m x 1.80m made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC 67 - 2022 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC 67 – 2022. The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2022 (As per MoRT&H specification No.801). Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete.
RF At Km 5/2- 9/075
Providing and fixing of Digitally Printed Retro Reflectorized Sign Board using UV Inkjet Printer made out of cube corner micro prismatic grade sheeting of Type-XI standards of IRC 67-2022 and ASTM D 4956 – 09 specification, Digitally Printed using UV Inkjet Printer (UVIJ) for traffic colour, images/ logos/ text and laminated with clear electro- cuttable film and applied to properly prepared sign substrates, fixed over 2mm Aluminium sheet with back supporting frame of 50x50x6mm Mild Steel ‘L’ angle and supported on a 150NB (Nominal Bore) pipe with 4.50mm thick with an overall height from top of the board to foundation. The sign board should be of 2.10m clear height from the ground level to the bottom of the sign board and 1.10m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete of size 450x450x1100mm including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete. The Micro prismatic sheeting should have minimum 70% coefficient of Retro-reflection values as per table 6.90 of IRC 67-2022. The retro- reflective sheeting shall be covered under 10 Years warranty issued for field performance and a certified copy of 3 years outdoor exposure report shall be obtained as per IRC 67-2022. The warranty shall be inclusive of digitally printed images/ logos/ test/ legends and their bonding to the retro-reflective sheeting (as per MoRT&H specification no.801) of Size – 3.64m x 2.42m
RF At Km 5/2- 9/075
Providing and Fixing of Flexible Median Marker that are made of tough, high impact resistant, injection- molded, thermoplastic body with property of flexibility to provide high durability. The dimension of Flexible Median Marker should not exceed 18.4 cm in eight(including shank height),12.5 Cm in width.,0.65 cm in thickness and shank depth shall be 3.4 cm The body structure shall be rounded at all its corners and edges. The plastic used for molding the Flexible Median Marker should survive impact load of 5kg ontinuously for 750 times at room temperature. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The Median Marker shall have flame like shaped body with, fluorescent yellow color retroreflective sheeting of size not less than 90 Cm square, with fully reflective micro prismatic cube corners as its retro-reflective elements as per IRC. 67 -2022 and ASTM D4956-09 type XI specifications reflectivity values. The retro-reflective sheeting shall be one or both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc., The Flexible Median Marker shall be fixed by a combination of epoxy adhesive and grouting as recommended by manufacturer.
RF At Km 5/2- 9/075
Calculation of SubTotal, GST and Total Amount carried out by system automatically
Basic cost of value put to tender as per estimate
Add GST at 18%
Total Value put to Tender
Quoted Percentage
Quoted Value
Add GST at 18% of Final Quoted Value
Total Value of Contract Including 18% of GST
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
PQVol1TRY98.pdf
Tender Documents • 0.36 MB
PriceVol2TRY98.pdf
Tender Documents • 0.46 MB
DRWTRY98.pdf
Additional Documents • 1.47 MB
BOQ_773563.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid