Assistant Engineer
Assistant Engineer 110kV Substation TERLS Thumba Post Kerala State Electricity Board Limited Thiruvananthapuram
Providing New LED Yard Lights at 110 kV TERLS Substation Phase 1 Installation (2 Light Poles) Including Associated Civil, Cabling and Earthing Works (Financial Year 2025-26
2026_KSEB_828958_2
06(E)/25-26/AE-TERLS dated 12-01-2026
Open Tender
Miscellaneous Works
Percentage
21 days
110kV substation, TERLS
should have experience in stone masonry, painting of building or masonry works or Other major Civil works in substations and satisfactorily completed similar works in any Government or Public Sector Enterprise during the last five years as on the dat
5 documents required · 5 mandatory
₹590
₹1,900
7 Feb 2026
7 Feb 2026
6 May 2026
7 Feb 2026
1 May 2026
7 Feb 2026
7 Feb 2026 - 18 Mar 2026
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil (cost index(c) : 1.4766 included in Rate)
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) (cost index©: 1.4766 included in Rate)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete (cost index(c) : 1.4766 included in Rate)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size (cost index(c) : 1.4766 included in Rate)
Installation of 7 m Octagonal Yard Light Pole (Material supplied by KSEB) (cost index(e) : 1.3424 included in Rate)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole (cost index(e) : 1.3424 included in Rate)
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, kg 114.92 48 5516.34 CONTR bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more (cost index(c) : 1.4766 included in Rate)
Uncoiling 4/2 core 2.5sqmm control cable (armored or unarmored) from cable drums and cutting to required length and laying through trench/pipe/cable tray neatly and carefully including for providing loops wherever necessary and cable marker at both ends of cable as per direction of departmental staff at site. (cost index(e) : 1.3424 included in Rate)
Laying of departmentally supplied GI strip/Copper strip of suitable size including cleaning and neatly bending of strips ,cutting, removing of metal/earth in the yard and burying earth strip to the required depth redoing the yard metalling as per the direction of the departmental officers. (cost index(e) : 1.3424 included in Rate)
Welding one end of the bended GI strip of size 50x6mm with the riser of the already laid earth mat, welding 150mm in length, 6mm thick on both sides & end of the strip & other end of the strip with yard structure at 2 points 50mm apart each welding points having 50mm length and 6mm thick on both sides & end of the strip including the charges for connecting the strip with structure using bolted joints as per the directions of the department officers. Charges includes hire charges of DC arc welding set, current charges, cost of low hydrogen content DC arc welding electrodes(No.E7018) cost of anti corrosive paint etc. complete. (cost index(e) : 1.3424 included in Rate)
Welding charge for welding on iron parts using arc welding as per standards (cost index(e) : 1.3424 included in Rate)
50.18.7.3.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-inCharge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall (cost index(c) : 1.4766 included in Rate)
Supply, Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tendernotice_2.pdf
PDF • 0.15 MB
Tendernotice_3.pdf
PDF • 0.11 MB
NITcompressed.pdf
Tender Documents • 0.11 MB
Malayalamcompressed.pdf
Tender Documents • 0.08 MB
BIDcompressed.pdf
Tender Documents • 0.40 MB
BOQ_1403802.xls
BOQ • 0.37 MB
Epayment.pdf
Other Document • 0.10 MB
Corregendumtenderyradlight220326.pdf
PDF • 0.20 MB
Corregendumtenderyradlight05032026.pdf
PDF • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .