Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹9.8 L+₹1.2 L (13.9%)Rejected-Finance | 2 | Rejected-Finance L2 |
Tender Value
₹12.7 L
EMD Value
₹31,761
Closing Date
8 Jul 2024, 3:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
PWD SPECIAL BUILDING SUBDIVISION, KOZHIKODE
GENERAL-Urgent Special repair works for damaged sunshades at IMCH, Govt. Medical college, Kozhikode-Maintenance of damaged sunshades and roof sheets-General Civil Work
2024_PWD_678919_1
PWD/BLDG/TR/10182/2023_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
180 days
Medical college
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹31,761
Yes
19 Aug 2024
3 Jul 2024
10 Jul 2024
3 Jul 2024
8 Jul 2024
3 Jul 2024
Amount
Repair work
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
OD46517/2023-2024::Chipping and removing old spalling/detective concrete and exposing the detective/corroded reinforcement of the ceiling, joint the additional bar wherever 1/3 diameter of the bar is corroded. Removel of the detective concrete across the bar should be at least 2mm beyond the detective bar so that the reinforcing bar can be cleaned with ribbon, wire brush etc. After cleaning the bar wash with clean water and collect all the spalled/ fallen concrete. Measurement is calculated for whole exposed area. Including cost of materials, labour charges, conveyance of materials to site hire charges of tools etc complete.
OD72358/2023-2024:The cleaned reinforcing bar on the dried bar applying corrotion inhibitant one coat of nitozinc primer care should be taken to seethat the zinc primer coated should make an unbroken continous film on the bars. After cleaning the bar applying one coat of bonding agent Nitobond AR/SBR measuement is calculated as in the previous case.including cost of meterials, labour charges, conveyance of materials to site hire charges of tools etc complete.
OD70573/2024-2025:The ceiling surface is to be smoothed with modified mortar to an average thickness of 15 mm. Measurement is calculated as in the previous case. Including cost of materials, labour charges, conveyance of materials to site hire charges of tools etc. complete.
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
OD83331/2023-2024:Providing asbestos plain sheets roofing up to any pitch and fixing with polymer coated J,or L hooks, bolts and nuts 8 mm dia. G.I plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
50.12.5.1:Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
OD69258/2024-2025:Taking down shutters of windows and repairing and clearing the thickly sticken matters, replacing the damaged fittings, broken glass panes etc. and replacing the damaged furniture fittings etc. replace the repaired shutters in the exact place after easing the edges etc. complete including cost and conveyance of all materials, all labour charges etc. complete, as per the direction of departmental officers at site.
SIDDIQUE M K
Bidder Name
SIDDIQUE M K
SANOOP
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1055801.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .