Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 3 26 DHUMANSOOR BIDAR DHUMANSUR KARNATAKA 585353 | BIDAR | KARNATAKA | 585353 | Admitted-Finance |
| 3 | Admitted-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹16 L
EMD Value
₹16,000
Closing Date
22 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
ADDN / ALTN TO AF PRE PRIMARY SCHOOL AND PROVISION OF CERTAIN WORKS AT AFS BIDAR
2023_MES_577201_1
8196/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹16,000
Yes
1 Mar 2023
25 Jan 2023
23 Feb 2023
25 Jan 2023
22 Feb 2023
8 Feb 2023
Amount
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc., laid bedded and pointed in any mortar complete all as specified and as directed .
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above GL) including removal of debris outside MD land complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Demolition of brick work, stone / boulder masonry, precast concrete block masonry etc., built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
PCC 75mm thick 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
PCC 25mm thick 1:2:4 type B0 using 12.5 mm graded stone aggregate as in sub base complete all as specified and directed.
Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces etc.,set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 10 mm thick backing coat in CM 1:4 complete all as specified and as directed.
Glazed coloured ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles as in skirting/dado including 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
Dismantling of wall and ceiling boards with frame work (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
S & F False ceiling with anodized aluminium frame work with 605mm x 605mm size snap gird fixed with screws / staples using 36.5mm x 23.5mm x 1.5mm thick main tee, 23.5 x 23.5 x 1.28mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 3.0mm dia GI wire and ‘J’ bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, complete all as specified and as directed.
Mineral fibre board/ tiles 12mm thick, 600mm x 600mm in size, fixed in ceiling, flat or sloping, including painting, complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but n.exc 4sqm each with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Factory made 35 mm thick flush shutters, solid core construction, with particle board core and ply wood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
Aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
Aluminum anodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Butt Hinges medium weight cold rolled mild steel 100 mm long complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, 150 mm over all length of cover plate , anodised with hard drawn steel spring fixed in floor, complete all as specified and as directed.
Preparation of new wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of old painted surfaces of wood and wood based materials of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old decorated surfaces of walls including cornices pillars etc by washing, rubbing down stopping and applying one coat of Oil Bound Distemper complete all as specified and as directed.
Taking down cement plaster on brick or concrete or stone wall, of any description including, racking out joints, hacking for key scrubbing down with water etc. complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement, complete all as specified and as directed.
Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed .
Preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Preparation of old painted surfaces of walls and applying one coat of cement base paint complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:6 complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:4 complete all as specified and as directed.
Providing precast reinforced cement concrete 1:2:4 type B1 as in window or door cills, lintels, bressumers, steps,quoin blocks, posts,boundary pillars,bed plates, pintle blocks, cover slabs etc., with plain fair faces set in CM 1:4 including necessary form work complete all as specified and as directed. Note: Reinforcrment steel will be measured and paid seperately.
TMT bars, 10mm dia & over, cut to length, bent to required shape including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and as directed.
All as per item No. 35.00 here in before but 6mm to 10mm dia in stirrups.
Bib tap screwed down high pressure, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union, complete all as specified and directed.
GI tubing,15mm bore medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
GI tubing,20mm bore medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Stainless steel kitchen sink, made of stainless steel 1 mm thick, with plugs, washers, PTMT waste coupling 38/40mm ( half or full threaded) incluing waste pipe 32mm bore with reducer socket, overall size 495mm X 420mm, bowl size 410mm X 330mm X 160mm including fixing in cement mortar on to dwarf wall or fixing cantilever brackets complete all as specified and as directed.
Granite (of any type) 18-20 mm thick, work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like including in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixtures of pigment to match with shade of granite complete all as specified and as directed.
Anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified as directed.
Anodized aluminium door shutters powder coated (minimum thickness of powder coating 50 micron), aluminium section weighing not less than 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified as directed.
Glazing with sheet glass 5.5 mm thick ordinary quality fixed to Aluminium or Steel frame in square n.exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Prelaminated particle board, 12mm thick ,exterior grade, one side pre-laminated with decorative choice and other side balancing white lamination, fixed to Aluminium or Steel frame work for shutters of doors, cabinets etc complete all as specified and as directed.
Mortice lock brass 4 levers vertical type, size 100mm complete all as specified and as directed.
Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3 universal aluminium (extruded section) body, suitable for aluminium door shutters of 851 to 1000 mm in width and of weight between 61 Kg to 80 Kg complete all as specified and as directed.
Excavation over area not exceeding 1.5m deep and getting out in hard / dense soil complete all as specified and as directed.
Excavation over area exceeding 1.5m but not exceeding 3.0m deep and getting out in soft disintegrated rock complete all as directed.
Excavation over area exceeding 3.0m but not exceeding 4.5m deep and getting out in soft disintegrated rock complete all as directed.
Excavation over area exceeding 4.5m but not exceeding 6.0m deep and getting out in soft disintegrated rock complete all as directed.
Excavaton in trenches, not exc. 1.5m wide and not exc 1.5m in depth, for foundations, laying pipes, drains or manholes 10 sqm on plan and getting out in hard / dense soil complete all as specified and as directed .
Excavaton in trenches, not exc. 1.5m wide and not exc 1.5m in depth, for foundations, laying pipes, drains or manholes 10 sqm on plan and getting out in soft / loose soil complete all as specified and as directed .
Returning, filling in soils including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as dorected.
Returning, filling in soft disintegrated rock including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as dorected.
Removal of surplus excavated material (soils) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Removal of surplus excavated material (rocks) to a distance exc 250m but n.exc 500m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and directed.
All as per item No.59.00 here in before but add or deduct for each 25mm girth or part thereof over or under 30cm.
Plain Cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping including necessary form work etc all as directed.
Loose filling with broken stone or boulders of gauge 80 to 150mm complete all as specified and directed.
Loose filling with stone aggregate of gauge 40 to 80mm complete all as specified and directed.
Hard core of crushed stones/boulders of guage not exc 63mm and depositing, spreading and levelling in layers not exc 15cm th, watering and well ramming complete all as specified and directed.
Sand filling including watering and consolidation complete all as specified and as directed.
Mild steel framed work such as grills and gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, laddars, framed balusters, walkways, railings, frame wk of water tanks and similar wks confirming to FE 290 Gde E-165 completed all as specified and as directed.
Preparation of new Steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) complete all as specified and as directed.
Taking down carefully old light fittings of any type complete with glass shade and lamp complete all as specified and as directed.
Taking down unserviceable existing MCB DB SPN / TPN complete all as specified and as directed.
Taking down unserviceable existing MCB SP / SPN / TPN complete all as specified and as directed.
Taking down unserviceable submain wiring of any type complete all as specified and as directed.
Point wiring with 1100V grade 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including concealed PVC 20mm dia (light duty) conduit and conduit accessories with concealed MS / PVC box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected to common earth dolly as specified for one light point / Fan point controlled by one switch 5 Amp complete all as specified and as directed. Note : (1) Rate quoted includes for cost of cutting chases in wall / floor / ceiling, making holes for MS / PVC box and making good to the original surfaces of any description disturbed. (2) Switch and socket shall be measured and paid for separately.
All as per item No. 72.00 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No. 72.00 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
Point wiring with 1100V grade 2.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including PVC 20mm dia (light duty) conduit and conduit accessories on wall , roof etc., with concealed pressed steel terminal box made out of 1.6mm thick MS sheet covered with 3mm thick laminated sheet of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm as earth wire connected to common earth dolly for one 5 Amp switch socket on independent board complete all as specified and as directed. Note : (1) Rate quoted includes for cost of cutting chases in wall / floor / ceiling, making holes for MS / PVC box and making good to the original surfaces of any description disturbed. (2) Switch and socket shall be measured and paid for separately.
Switch piano flush, single pole, one way, 5/6 Amp, complete all as specified and as directed.
Switch piano flush, single pole, one way,1 5/16 Amp, complete all as specified and as directed.
Switch socket outlet 3/5 Pin 5/6 Amp, flush type, complete all as specified and as directed.
Switch socket outlet 5/6 Pin 15 Amp, flush type, complete all as specified and as directed.
Ceiling rose surfaces bakelite 63.5 X 28mm three terminals complete all as specified and as directed.
Fan regulator, AC, 230V, single pole electronic, step type, complete all as specified and as directed.
Switch modular type single pole one way 6 Amp with all accessories completeall as specified and as directed.
Socket outlet multipurpose 2/3 Pin , 6A modular type with all accessories complete all as specified and as directed.
Fan regulator, two module, , step type, AC, 230V, electronic, complete all as specified and as directed.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable, 1100 volts grade, multi stranded copper conductor drawn through and including suitable size of PVC conduit pipe and accessories concealed to surface / wall roof etc with one run PVC insulated 4sqmm FRLS cable , copper condutor for earth continuity conductor all as specified and as directed. Note : Three runs of of 4.0 sqmm PVC insulated stranded copper conductor and one run of PVC conduit shall be measured and paid as one unit.
MCB DB SPN 8 way, double door with 200 Amps rated copper bus bar in SS enclosure complete all as specified and as directed.
MCB SP 5-32 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
MCB SPN 32 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
MCB SPN 40-63 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
Ceiling fan 1200mm sweep complete with three blades, down rod with all accessories, 230V with squirrel cage induction motor complete all as specified and directed.
Exhaust Fan, steel body Heavy duty with Louvers/Shutters single phase 230 volts of 300 mm sweep complete with clamps, rubber bush and grouting Bolts, nuts, washers complete all as specified and directed.
S & F in replacement of 36W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 2ft X 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K complete all as specified and as directed.
Earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with 50mm thick with 6mm dia MS bars as shown in SSR Pt - 1 electrical plate No 3 complete all as specified and as directed. Note: Quoted rate deemed to include the cost or excavation and earth work PCC chamber, funnel cover etc
S & F 20/22 W LED Surface mounted, batten fixture, 1200mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink. The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K complete all as specified and as directed.
S & F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium bldg security light luminaries with high power LED as light source of power 45 W, IP 66, system luminous efficacy >85 Lm/ W, life 50,000 hrs, surge protection 10 kV and zero maintenance including all light fittings etc. and connection from ceiling rose to light fitting by using three core 1.5 sq mm copper conductor cable complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 25 Sqmm 3.5 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 10 Sqmm 2.0 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply and spreading natural river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note: Punned thickness will be measured and paid for purpose of the payment.
Supply and laying unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed.
GI Steel tubing light grade of 40mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed.
Street light bracket made out of 40mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 50 x 6mm thick (2 Nos) with suitable nut, bolts and washers to steel tubular / concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete all as specified and directed
Steel tubular swaged poles type 410 SP-31 (9metres long) with cast iron base plate, finial taper plug, bolts, nuts & screws including two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. Note :- Excavation & Earth work , PCC for foundation and coping will be measured and paid separately under respective items of the schedule.
Junction box made from FRP sheet ready made of size 200x150x 100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole / wall with MS clamp 25x5 mm duly painted with one coat of red oxide and two coats of synthetic enamel to MS clamp complete all as specified and as directed.
NAYANA CONSTRUCTIONS
AMAR CONSTRUCTION
om sai enterprises
VAISHNAVI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .