| 1 | L1₹37.4 LAccepted-AOC | ₹37.4 L Quoted ₹38.3 L | L1 | Accepted-AOC Accepted being lowest and reasonable one. |
| 2 | L2₹44.3 L+₹5.9 L (15.5%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹44.3 L+₹5.9 L (15.5%) | L2 | Rejected-Finance Rejected being L2 |
| Sl No | Description | Qty | Unit | bharat contrectors L2 | MM Engineers L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed by Engr-in-Charge.
Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.
(b) Examine any water leakage from geyser/storage tank.
(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.
(d) Replace washers and glands to ensure smooth functioning.
(e) Inspect vent pipes and remove blockage obstruction if any.
(f) Check and correct earth continuity of electrical items.
(g) Check and correct temperature setting of thermostats.
(h) Items reqd for replacement will measured under respective item of BOQ. | 150 | EACH | 500 ₹75,000 | 100 ₹15,000 Lowest |
| 2.00 | Description all as per Item No 1.00 here in before but for geyser of cap 35/ 50 ltrs. | 10 | EACH | 550 ₹5,500 | 125 ₹1,250 Lowest |
| 3.00 | Supply only heating element of capacity 2 KW of geysers of any make/capacity complete all as specified and directed by Engr-in-Charge. | 90 | EACH | 550 ₹49,500 | 400 ₹36,000 Lowest |
| 4.00 | Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity, complete all as specified and directed by Engr-in-Charge. | 70 | EACH | 560 ₹39,200 Lowest | 1,200 ₹84,000 |
| 5.00 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity,of any make 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed by Engr-in-Charge. | 90 | EACH | 500 ₹45,000 | 400 ₹36,000 Lowest |
| 6.00 | Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,of any make 20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed by Engr-in-Charge. | 5 | EACH | 550 ₹2,750 | 450 ₹2,250 Lowest |
| 7.00 | Supply only temperature resistent SS braided PVC pipe heavy duty suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete all as an directed. | 200 | EACH | 500 ₹1,00,000 | 140 ₹28,000 Lowest |
| 8.00 | Supply only Non-return valve 15mm / 20mm dia of brass as per requirement complete all as specified and directed by Engr-in-Charge. | 35 | EACH | 800 ₹28,000 | 190 ₹6,650 Lowest |
| 9.00 | Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed by Engr-in-Charge. | 60 | EACH | 100 ₹6,000 | 45 ₹2,700 Lowest |
| 10.00 | Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity complete all as specified and directed by Engr-in-Charge. | 10 | EACH | 2,000 ₹20,000 | 1,400 ₹14,000 Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
30 Jun 2026, 6:00 pmClosed
LT COL CHETAN KOTKAR, GE (SOUTH) AMBALA
GE (SOUTH) AMBALA CANTT
GE(SOUTH)/AMB 30 2026 2027 CERTAIN REPAIR REPLACEMENT WORKS OF INTERNAL WIRING MCBs/DBs SUBMAIN EARTHING AND OTHER CONNECTED WORKS AT NORTHEN ZONE MD ACCN OF JCO/ORs AND ADJOINING AREA UNDER GE (SOUTH) AMBALA CANTT
2026_MES_770778_1
GE(SOUTH)/AMB-30/2026-2027
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (SOUTH) AMBALA CANTT
₹78,000
Yes
17 Sept 2026
9 Jun 2026
2 Jul 2026
9 Jun 2026
30 Jun 2026
24 Jun 2026
9 Jun 2026 - 23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed by Engr-in-Charge.
Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.
(b) Examine any water leakage from geyser/storage tank.
(c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts.
(d) Replace washers and glands to ensure smooth functioning.
(e) Inspect vent pipes and remove blockage obstruction if any.
(f) Check and correct earth continuity of electrical items.
(g) Check and correct temperature setting of thermostats.
(h) Items reqd for replacement will measured under respective item of BOQ. | 150 | EACH | - | - |
| 2 | Description all as per Item No 1.00 here in before but for geyser of cap 35/ 50 ltrs. | 10 | EACH | - | - |
| 3 | Supply only heating element of capacity 2 KW of geysers of any make/capacity complete all as specified and directed by Engr-in-Charge. | 90 | EACH | - | - |
| 4 | Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity, complete all as specified and directed by Engr-in-Charge. | 70 | EACH | - | - |
| 5 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity,of any make 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed by Engr-in-Charge. | 90 | EACH | - | - |
| 6 | Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,of any make 20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed by Engr-in-Charge. | 5 | EACH | - | - |
| 7 | Supply only temperature resistent SS braided PVC pipe heavy duty suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete all as an directed. | 200 | EACH | - | - |
| 8 | Supply only Non-return valve 15mm / 20mm dia of brass as per requirement complete all as specified and directed by Engr-in-Charge. | 35 | EACH | - | - |
| 9 | Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed by Engr-in-Charge. | 60 | EACH | - | - |
| 10 | Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity complete all as specified and directed by Engr-in-Charge. | 10 | EACH | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tenderdocuments30.pdf
Tender Documents • 1.08 MB
BOQ_863168.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .