Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹46.9 L Quoted ₹47.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹48.7 L+₹78,930 (1.65%)Rejected-AOC PREM NAGAR GALI NO 3 RAJPUTANA SALEMPUR ROORKEE DISTT HARIDWAR UK | ROORKEE | HARIDWAR | UTTARAKHAND | ₹48.7 L+₹78,930 (1.65%) | L2 | Rejected-AOC Not Lowest |
| 3 | Rejected-Technical 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | - | Rejected-Technical Due to adverse remark in HQ CE SC Pune WLR QE Sep 2022 |
Tender Value
₹50.4 L
EMD Value
₹1.0 L
Closing Date
20 Mar 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS , MALL ROAD, DEHRADUN CANTT - 248003
REPAIR/ REPLACEMENT OF CENTRIFUGAL PUMP SETS, ELECTRIC MOTORS, STARTER PANELS AND CONNECTED WATER SUPPLY INSTALLATION UNDER AGE (I) LANSDOWNE.
2023_MES_582976_1
87158/LDN/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
150 days
AGE (I) LANSDOWNE
Class C Category b(i)
6 documents required · 6 mandatory
₹1,000
AGE I LANSDOWNE
₹1.0 L
Yes
6 May 2023
25 Feb 2023
27 Mar 2023
25 Feb 2023
20 Mar 2023
6 Mar 2023
Amount
Supply, fix, commissioning and testing of centrifugal multistage pump set horizontal type suction / delivery -65x50mm, discharge capacity-36 cum/hr, 250 mtr head, mechanical seal arrangement including 3-phase energy efficient squirrel cage induction motor as prime mover, 415 V, S1 duty rating, energy efficiency level -IE 3 BEE star rated, ISI Marked 50 HP (37 KW) 3000/2900RPM as per IS- 12615 ( latest edition) fixed to pump through jaw type coupling with pump impellor of phosphorous bronze and shaft of carbon steel complete with and including PCC (1:2:4) type B1, foundation, base frame and cable connection including taking down of old pump set from foundation and removing from site and deposited to MES store yard complete all as specified and as directed. NOTE:- (i) The work includes taking down of old pump set from foundation, shift to MES store of AGE(I) Lansdowne and demolition of existing PCC complete. (ii) The work will be carried out at Jharapani pump house under AGE (I) Lansdowne.
Supply, fix, commissioning & testing of centrifugal multistage pump horizontal type suction / delivery -65x50mm, discharge capacity-45 cum/hr, 250 mtr head, mechanical seal arrangement 3000/2900RPM with pump impellor of phosphorous bronze, shaft of carbon steel shaft, jaw type coupling including making PCC foundation and base frame of MS Channel for pump motor set, allignmment with existing motor and cable connection complete all as specified and as directed. NOTE:-(i) The work will be carried out at 3rd stage Pump House which is not connected by road and includes taking down of old pump from 3rd stage and 2nd stage pump house foundation, shift to MES store of AGE(I) Lansdowne. (ii) The Pump need to be matching with existing electric induction motor.
S&F in repair GI tubing "heavy grade" (ISI Marked) of size 100 mm (4") dia with screwed joints or welded joints all as per site requirement incl all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc complete all as specified and directed at water supply distribution/pumping system Lansdowne.
S&F in repair cast iron foot valve, flanged end type confirming to IS-4038, ISI marked alongwith fixing accessories such as suitable size nut, bolts, washer & rubber gasket of following size complete all as per site requirement all as specified and directed :-
100 mm dia
80 mm dia
Taking down non functional electric induction motor of any size and capacity from water supply installation at zero/ Ist/ IInd stage pump house which are not approachable by road and 3rd stage/ Jharapani/ 2nd lift/ 15 LGLN pump house, decoupling motor from pump and cutting, removing burnt out copper winding and re-winding with super enamelled copper wire of suitable gauge conforming to IS 13730-0-6 (2012) and reassembling/couple back complete and transporting back to its original location and making necessary allingnment and electric connection all as directed at site by Engg-in-Charge. Note :- Any other spare parts, if needed to be replaced shall be measured & paid as supply only separately under respective item of Sch 'A'/ BOQ.
Supply only following spare parts suitable for above mentioned complete all as specified and directed :-
Stainless steel bush/shaft sleeve for suction/delivery for 75 HP centrifugal multistage horizontal pump with bore as per sample.
Stainless steel bush/shaft sleeve for suction/delivery for 100 HP centrifugal multistage horizontal pump with bore as per sample.
Cast steel bearing lock nut with washer as per sample for 100HP Pump.
Roller bearing NU-207 for 100HP Pump.
Bush type flexible cast iron flanged coupling with finished bore and keyway as per sample for centrifugal Pump set.
Rubber bush along with pin (high tensile nut bolt) as per sample for flexible coupling.
S&F in repair water pressure guage of pressure 0-40 kg/sqcm with dial size of 100 mm dia along with ball valve of suitable size complete all as specified and directed.
M&L in repair for fabrication and fixing of mild steel, plain, black sheet of thickness 1 mm for making coupling guard, cut to size, holes punched, including round headed screws, clout nails or rivets, bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Supply and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Taking down of electric induction motor of capacity 100 HP from foundation of Pump set base frame of 2nd Stage Pump House water supply installation and Shifting to 3rd stage pump house water supply installtion and including refixing on new PCC (1:2:4) type B1 platform on MS channel complete all as specified and directed. Note: The work will be carried out at 2nd Stage and 3rd stage Pump House which is not connected by road.
S&F in repair Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 2.00mm thick CRCA sheet, protection of enclosure IP-42 as per IS : 2147 of 1962 with 07 tank process pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar chamber : Electrically grade shrouded aluminium bus bar of capacity 400 Amps for each phase and 200 Amps for neutral and current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension. The wk to be carried out at 2nd Lift and 15 LGLN Pump House.
(c) OUTGOING:- with two compartment each comparment witll consist the following : (i) MCCB 160 amps, 415Volts, 3 pole 50 Hz, 25 KA with adjustable thermal magnetic released in built instantaneous protection, Ics = 100 % Icu(1 sec) -01 Nos. (ii ) Contactors 95 Amp -02 Nos for Main & Delta (iii) Contactor 95 Amp -01No for Star (iv) Motor protection relay type MPR300 - 01 No (v) Phase failure relay with under and over voltage settings - 01 No , (vi) Star delta timer - 01 Nos , (vii) Green push button with NO -01 No (viii ) Red Push button with NC - 01 No (ix ) ON Red indicaiton lamp - 01 No (x) OFF Green Indication Lamp - 01 No (xi) Terminals 125 Amps bus bar type -06 Nos , (xii) MCB DP 6 amps 10 KA - 01 No (xiii) CT of ratio 250 /5 amps 5VA Class 1.0 .-03 Nos ,Including necessary connection with pvc insulated stranded copper conductor cable of suitable size.
S&F in repair Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 2.00mm thick CRCA sheet, protection of enclosure IP-42 as per IS : 2147 of 1962 with 07 tank process pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : - (a) Busbar chamber : Electrically grade shrouded aluminium bus bar of capacity 600 Amps for each phase and 300 Amps for neutral and current density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension. The wk to be carried out at 3rd Stage Pump House which is not connected by road.
(c) OUTGOING:- with two compartment each comparment witll consist the following : (i) MCCB 200 amps, 415Volts, 3 pole 50 Hz, 25 KA with adjustable thermal magnetic released in built instantaneous protection, Ics = 100 % Icu(1 sec) -01 Nos. (ii ) Contactors 140- Amp -02 Nos for Main & Delta (iii) Contactor 140 Amp -01No for Star (iv) Motor protection relay type MPR300 - 01 No (v) Phase failure relay with under and over voltage settings - 01 No , (vi) Star delta timer - 01 Nos , (vii) Green push button with NO -01 No (viii ) Red Push button with NC - 01 No (ix ) ON Red indicaiton lamp - 01 No (x) OFF Green Indication Lamp - 01 No (xi) Terminals 200 Amps bus bar type -06 Nos , (xii) MCB DP 6 amps 10 KA - 01 No (xiii) CT of ratio 400 /5 amps 5VA Class 1.0 .-03 Nos, Including necessary connection with pvc insulated stranded copper conductor cable of suitable size.
Notes for Item No 11 & 12 :- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tank pretreatment of MS sheet facilities, dust free spray paint booth.(8 tanks pretreatment process includes: degreasing/water rinsing/de-dusting/water rinsing/activation/phosphating water rinsing/passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel 3. The panel manufacturer should have following certification: (i) CPRI certification degree of protection IP-54 ( should have IEC:61439-1-2 & IEC:60529 tests) (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA (iii) CPRI certification rated current for short circuit not less than 5000A 4. All the electricals switch gear like MCCBs, MCB should be of same make 5. Drawing of panel board should be got approved from GE before fabrication. 6. Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2. 7. The rate quoted above shall include the cost of shifting of old starter panel to MES store yard.
Supply, laying & testing in repair of PVC insulated unarmoured and unsheathed Single core copper conductor flexible cable of following size complete all as specified and directed :-
25 Sqmm Cable
35 Sqmm Cable
S&F in repair U-PVC pipe of size 75 mm(bore) of SCH-40 including all pipe line fittings like elbow, socket plug hose clips adaptors cutting through walls floors and making good or laying in trenches complete all as specified and directed by Engg-in-Charge.
S&F in repair electronic star delta timer 3-30 seconds type ST100,160-500Volts, 50Hz complete all as specified and directed.
S&F in repair Power Contactor 95 Amps complete all as specified and directed.
S&F in repair auxiliary contact block side mounting with 1 No + 1 NC commplete all as speciffied and directed.
S&F in repair motor protection relay D2MPR commplete all as speciffied and directed.
S&F in repair Phase failure relay with under and over voltage settings complete all as specified and directed.
M&L for cleaning of semi UG Sump of following capacity after emptying the sump with help of Pump, removing all mud, waste etc complete, scrubbing the entire sump inside with wire brush, washing the entire sump from inside with water and subsequently with bleaching powder solution and painting inside with two coats of lime wash and writing date of cleaning with white paint after making a block of black paint complete all as specfied & directed :-
16 Lakh Gln capacity
7.5 lakhs gallon capacity
4.5 lakhs gallon capacity
3 Lakh/2.5 lakhs gallon capacity
2 Lakh/ 1.5Lakh/ 1.4 Lakhs gallon capacity
1 Lakhs gallon capacity
50000 /45000/40000 gallon capacity water storage tank
10000 gallon capacity water storage tank Note for item No 20 :-Date of cleaning shall be painted with synthetic enamel paint on sump all as directed.
Supply, Installation, Testing and Commissioning of Ultrasonic Level Transmitter (Water Level Indicator) at Sump for measurement of level with following specification:- Range : 0-8 meters Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA , 0-10V DC
Supply, Installation Testing & Commissioning of Outdoor type having Canopy and Double Door for weather protection, PLC ( Programmable Logic Controller) based Automation, Protection Panel suitable for control and monitoring of 01 Nos. Ultrasonic Sensor. The panel should be of minimum size 800(H) X 600(W) X 250(D) mm fabricated from 3.00 mm CRCA Sheet protection of enclosure IP-54 as per IS : 2147 of 1962. the Panel should comprise the following functions & items:- (i) Water Level Sensing & Display (ii) 01 No. PLC with follwing specifications:- (a). Non isolated RS 485 communication port or Ethernet communication port. (b). Suitable No. of digital / analog input and outputs. (c). Programming software based on IEC to facilitate building of custom build function blocks. (iii) 01 no. HMI - 7" Graphical Touch screen display (a). Should have 01 No. RS 485 and 01 No. USB programming port. (b). Should have USB downloading port. (c). Support external data storage on a USB memory stick for storing production data and backing up applications (iv) 01 No. SMPS of 1.5A rating as suitable according to panel design. (vii) MCB rating 6-10A. (viii) Indicator lamp :- As per requirement
S&F PVC sheathed PVC insulated copper armoured cable of following size complete all as specified and directed :-
2 Core 1.5 Sqmm
4 Core 1.5 Sqmm
S&F rigid non metalic 25mm dia PVC Condiut exclusive of boxes (Junction/terminal) but inclusive of all tees, bendss, elbows, reducers bell mouthy tube ends and fixing accessories suych as coupler, lock nut, saddels pipe hooks etc complete all as per site requirement all as specified and directed.
Taking down carefully old serviceable gate valves of 50mm size and depositing the same to MES store yard which will be taken on charge for reuse at other location complete all as specified and directed.
Taking down carefully old serviceable sluice valves of following size and depositing the same to MES store yard which will be taken on charge for reuse at other location complete all as specified and directed :-
Supply, Installation, testing and Commissioning of 50 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness complete all as specified and directed.
Supply, Installation, testing and Commissioning of 50 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 24 inches above ground level complete all as specified and directed.
Supply, Installation, testing and Commissioning of 80 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 80 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 24 inches above ground level complete all as specified and directed.
Supply, Installation, testing and Commissioning of 100 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed
Supply, Installation, testing and Commissioning of 100 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 24 inches above ground level complete all as specified and directed.
Supply, Installation, testing and Commissioning of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be direct type using specialized arrangement of GI pipe of suitable size/thickness, complete all as specified and directed.
Supply, Installation, testing and Commissioning of 150 mm dia, single phase, Motor Actuated Butterfly valve with disc material SS - 304, Stem Material SS - 410, Seat EPDM, hand wheel for manual operation and having 05 nos. limit switches for Open / Close condition, valve position indicator and over ride trip. The housing of actuator should be of Aluminium Dicast. Input Voltage: 230 V, A.C. Designed line pressure: 60 kg/sq cm. The mounting shall be indirect type using specialized extended type arrangement of GI pipe of suitable size/thickness, so that actuator mounting is at least 24 inches above ground level complete all as specified and directed.
M&L for Bus bar chamber, including MCCB 4 pole, 63 Amps, 415 V, with anodised AL Bus bar of rating 100 Amps upto length of 40 cm mounted on DMC insulator, Sheet steel enclosure of thickness 1.6mm, fixed with cables on wall complete all as specified and directed. Note:- Required civil work/ MS Angle work/ PCC fondation and suitable glands may be included in rate.
S&F in repairs including laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminium stranded conductor LT UG cable (Conforming to IS 7098) ISI marked in treches/ ducts/ through GI pipe of size 150 Sqmm 3.5 core complete all as specified and directed.
S&F in repairs including laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 25 Sqmm 3.5 core complete all as specifed and directed. Note for item No 36 & 37;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Excavation in trenches in any type of soil n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation laying of pipe etc n.exc 10 sqmm on plan and n.exc 1.5 mtr in depth and getting out complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not.exc 25cm each layers complete all as specified and as directed.
Removal of excavated material & surplus soil to a distance n.exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for brunt bricks sub class 'B' in old size as cable protection laid flat width wise complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
S&F GI pipe, light grade laid in trenches / under Road/ Under culvert/ Under Floor/ Under PCC/ drain for cable protection and making Good of disturbed surface with PCC 1:2:4 type B-1 of following bore complete all as specified and directed :-
50 mm bore
80 mm bore
Collecting water sample from water supply installation of lansdowne and carry out water quality test (pH, TDS, Turbidity, Alkalinity, Total hardness, Fluoride, nitrate, Sulfate, RFC, Colour, Conductivity, Chloride, odour, Total coliform, E.Coli) from recognised government organisation complete all as specified and directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6.00 m mean radius built in cement mortar (1:6) for Pipe Line Support complete all as specified and directed.
M&L for 10mm thick rendering in cement plaster (1:6) on external surfaces of brick wall/ concrete surface complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 40 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x4mm galvanised iron strip incl taking down old strip complete all as specifed and directed.
M/S Konark Electric Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .