Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹42.7 L+₹1.9 L (4.62%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹43.1 L+₹2.3 L (5.59%)Rejected-Finance DOOR NO 36 72 5 BOOSAVARI STREET REDDY KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹43.8 L+₹3.0 L (7.25%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹44.8 L+₹3.9 L (9.59%)Rejected-Finance | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
REPAIRS AND REPLACEMENT OF OLD CORRODED U/S MS/GI/CI/DI WATER SUPPLY DISTRIBUTION SYSTEM AND OTHER CONNECTED MISC WORK AT ASHOKA PARK, PALLAVA PARK, MO (V) NEW SITE, WED, NSB, NAUSHAKTI VIHAR AND NAMAC UNDER GE (UTILITY-II) VISAKHAPATNAM
2023_MES_621369_1
8933/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Utility-II
₹96,000
Yes
2 Jan 2024
3 Oct 2023
25 Oct 2023
3 Oct 2023
24 Oct 2023
19 Oct 2023
Amount
Labour for attending GI pipe 15 mm to 40 mm dia pipe line complaints (break downs) upto G+3 floor, terrace, wall and plane area including cutting and threading of pipes as per requirement of site, complete all as specified and directed. Note: GI Pipe and fittings shall be measured and paid separately under relevant items.
Labour for attending GI pipe 50mm to 80 mm dia pipe line break downs (plain area), trenches, on floor and upto G+3 floor including cutting threading of pipes as per site requirement, complete all as specified and directed. Note: GI Pipe and fittings shall be measured and paid separately under relevant items.
Labour for attending GI pipe 15 mm to 80 mm dia pipe line complaints (break downs) in multi storage building 4th floor to 9th floor and above including cutting and threading of pipes as per requirement of site including necessary scaffolding and safety measures, complete all as specified and directed. Note: GI Pipe and fittings shall be measured and paid separately under relevant items.
Supply only GI tubing medium grade, galvanised of following sizes. Note: The Quoted rate shall be deemed to include GI sockets and GI nipple, GI Union, GI Elbow.
For Size 15 mm dia.
For Size 20 mm dia
For Size 25 mm dia.
For Size 40 mm dia.
For Size 50 mm dia.
For Size 80 mm dia.
Supply and fix 15 mm dia gun-metal gate valves, with iron wheel head, screwed both ends, complete all as specified and directed.
All as Srl Item No 11 above but for 20mm outer dia
All as Srl Item No 11 above but for 25mm outer dia
All as Srl Item No 11 above but for 40mm outer dia
All as Srl Item No 11 above but for 50mm outer dia
All as Srl Item No 11 above but for 80mm outer dia
Excavation in trenches n.exc. 1.5m wide and n.exc1.5m depth for foudation, trenches for laying of cables/pipe line etc. and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling in, incl. spreading, levelling, watering and well ramming in layers not exc 25cm in type of soil, complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point., complete all as specified.and directed
Supply and fix 15 mm bore GI tubes, medium grade, galvanised with all fittings and fixed complete to walls, plain area, trenches and ceilings or laying in floors including taking down the existing GI pipes, complete all as specified.and directed Note: Earth work shall be measured and paid separately under relevant items.
All as Srl Item No 20 above but for 20mm dia.
All as Srl Item No 20 above but for 25mm dia.
All as Srl Item No 20 above but for 40mm dia.
All as Srl Item No 20 above but for 50mm dia.
All as Srl Item No 20 above but for 80mm dia.
All as Srl Item No 20 above but for 100mm dia.
M&L for cement concrete PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in including necessary form work, complete all as specified.and directed
M&L for masonry valve chamber of size 600x600x600 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats a over a coat of zinc chrome primer, compete all as specified and directed.
M&L for masonry valve chamber of size 900x900x900 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats a over a coat of zinc chrome primer, compete all as specified and directed.
S & F 32 mm outer dia, 3-layer PP-R (Polypropylene random copolymer) pipe concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply along with all PP-R plain and brass threaded polypropylene random fittings with connected accessories including taking down the existing PP-R pipe, compete all as specified and directed.
All as Srl Item No 30 above but for 50mm dia.
All as Srl Item No 30 above but for 63mm dia.
S & F PP-R gate valve (Brass Insert) of 25mm bore (outer dia) including taking down old gate valve complete all as specified and as directed .
All as Srl Item No 33 above but for 32mm dia.
All as Srl Item No 33 above but for 40mm dia.
All as Srl Item No 33 above but for 50mm dia.
All as Srl Item No 33 above but for 63mm dia.
M&L for mild steel (plain or chequered) plates in required shape as covers of sumps, cover of cable ducts, cover of valve chambers as existing without any alternates conforming to Fe410W (Gde E-250) Quality A including removing old unserviceable one, complete all as specified and directed.
Labour only for attending break down of pipe line bursting / cracks for 100/80mm bore DI/MS pipe size including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering by using necessary dewatering pumps, JCB's, Cranes complete all as specified and directed Note 1 :- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for Dismantling /fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- Earth work, Supply only (as for site, as per types, as per size) pipes, specials, fittings will be measured and paid separately under relevant items.
All as Srl Item No 39 above but for 150 mm bore DI/MS pipe
All as Srl Item No 39 above but for 200mm bore DI/MS pipe
Supply only MS ERW pipe of 200mm dia, high grade, complete all as specified and directed.
All as Srl Item No 42 above but for 150mm dia.
All as Srl Item No 42 above but for 100mm dia.
All as Srl Item No 42 above but for 80mm dia.
Supply and laying MS ERW pipe of size 200 mm bore, high grade for inserting the pipe in position and including making leak proof joints and necessary fittings including taking down old pipe, complete all as specified and directed Note: Earth work shall be measured and paid separately.
All as Srl Item No 46 above but for 150mm dia.
All as Srl Item No 46above but for 100mm dia.
All as Srl Item No 46 above but for 80mm dia.
Note:- (i) The rate quoted is inclusive of necessary CTs, Control wiring and instrument fuse holder. (ii) Seven spare bay shall be provided to accommodate MCCBs , one bay for incoming MCCBs and six bay for outgoing MCCBs . (iii) The rate quoted is inclusive of all type of electric cable connection with existing MCCB or with New one MCCB of any capacity.
Supply and fix in repairs MCCB 63 Amps, 3 Pole, breaking capacity 36 KA with continuously adjustable electronic release, complete all as specified and directed
Supply and fix in repairs MCCB, 100Amps, 3 Pole, breaking capacity 36 KA with continuously adjustable electronic release, complete all as specified and directed
Supply and fix in repairs MCCB, 125Amps, 3 Pole, breaking capacity 16 KA with microprocessor release, adjustable type, complete all as specified and directed
Supply and fix in repairs MCCB, 160Amps, 4 Pole, breaking capacity 36 KA with microprocessor release, adjustable type, complete all as specified and directed
Supply and fix in repairs MCCB, 200Amps, 4 Pole, breaking capacity 36 KA with microprocessor release, adjustable type, complete all as specified and directed
Supply and fix in repairs MCCB, 250Amps, 4 Pole, breaking capacity 36 KA with microprocessor release, adjustable type, complete all as specified and directed
Supply and fix in repairs MCCB, 400Amps, 4 Pole, breaking capacity 36 KA with microprocessor release, adjustable type, complete all as specified and directed
M & L for painting as required colour of old painted steel surfaces (Pipes, LT Panels, Chambers, MS plates etc.) of any description over 10 cm width or girth, not otherwise described, complete all as specified and as directed.
Supply and replace pressure gauge 0-10 Kgs/Sq mm with 4" dia including necessary fittings, complete all as specified and as directed.
Supply and replace gland packing rope of 8/10/12/12.5/14/16mm sizes to pump sets of different sizes and capacities, complete all as specified and directed
M&L Synthetic mat (rubber matting) suitable for 11000 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board, complete all as specified and directed.
Supply and fixing CI sluice valve of size 200 mm dia, PN 1.6 conforming to IS 14846 flanged end with iron wheel head, stainless steel spindle, flange joints and including necessary nuts, bolts, washers, rubber washer etc and taking down old existing sluice valve, complete all as specified and directed.
All as Srl Item No 62 above but for 150mm dia.
All as Srl Item No 62 above but for 100mm dia.
Supply and replacement of Cast Iron Non return Valve with by pass arrangement with necessary rubber gasket, bolts, nuts and washers for sizes 150 mm bore complete all as specified and directed.
All as Srl Item No 65 above but for 100mm dia.
All as Srl Item No 65 above but for 80mm dia.
All as Srl Item No 65 above but for 65mm dia.
Supply and replacement of CI foot valve 150 mm bore complete all as specified and directed
All as Srl Item No 69 above but for 100mm dia.
All as Srl Item No 69 above but for 80mm dia.
All as Srl Item No 69 above but for 65mm dia.
All as Srl Item No 69 above but for 65mm dia.
M&L for seven stage cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedimentation/clear water sumps of capacity UG sump reservoir 1.0 Lakh gallons through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Make: rays Cleantech/ Inus watertech/ Satya enterprise. Location: PH NO-4 seven stages are as under plants:- (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks.
Item No 74.00 contd--- (c). Third storage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified branded halogen compound. (e). Fifth stage is cleaning the floor of water tank by industrial vacuum cleaner. (f) . Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY RAYS CLEANTECH/ INUS WATERTECH/ SATYA ENTERPRISE.
All as Srl Item No 74 above but for 50000 gallons capacity
All as Srl Item No 74 above but for 10000 gallons capacity
All as Srl Item No 74 above but for OH Water Tank of 1.00 lakh gallons capacity at 18m staging
Notes:- for Srl Item No 74 to 77 above (a) Company shall submit government laboratory test certificate of TERBAC-G5/INCHOR-5/NB-10, TERBAC-G65/ INOXII-60/NB-69 and also provide certificate confirming the completion of sterilization of water tanks alongwith mentioning the Date of Cleaning. all the cleaning & sterilization staffs should be under accidental insurance coverage (b) Outlet pipe of OHT should be plugged before cleaning the OHT to avoid entering scales and shall be reconnected after the cleaning and the quoted rate is deemed to include for the provision. (c) Sterilization team will be comprised of at least 30% members who are minimum 03 months certificate holder in water tanks sterilization. (d) contractor will be responsible for rectification of complaints occurred during cleaning the tank ie. No water in tank/over flow due to broken of float valve/ blockage to be included in quoted rate.
Design, fabricate and install fully retro reflective sign board (both side written) made out of 18 gauge CRCA sheet (1200mm X 900mm) with 40mm dia stainless steel square / round tube 1.6 mm thick having entire surface of both sides fully bonded with retro reflective sheeting of HTP grade tape having pressure sensitive adhesive boards and messages as indicated cut out back ground in blue / green and matter in white colour tape having two posts 3.0 m long made of 65 mm dia circular tube 1.6 mm thick sheet embedded in PCC (1:2:4) type B1 (20mm graded stone aggregate) bed block of size 300mm X 300mm X 600mm depth including necessary earth work excavation, including removing the old one complete all as specified and directed.
M&L for testing of water sample from source or sumps from various installation as speciefied and directed by the Engineer-in-Charge and test the sample as per IS 10500:2012 at Andhra University or any other accredited laboratory and submit the test report to Engineer-in-Charge Note: Quoted rate is deemed to be inclusive of collection of water at sumps or water source at different location under AOR of AGE E/M No. 1 in suitable container and submit for testing . The above specified job shall be carried out at each pump house as under :- (a) Naushakti Vihar Pump House - 4 Nos (b) MO(V) Pump House (c) WED Pump House (d) NCB Pump House .(e) CE(N) Pump House (f) Navy House Pump House (g) HF/DF Pump House
Notes :- The item rate is inclusive of following :- (a) Lab test shall be carried out once in a month from locally available Govt NABL approved lab for (i) PPM, (ii) TDS, (iii) pH value and E-Coil or thermotolerent Coliform bacteria (iv) colour and odour (v) Amonical Nitrogen, Nitrite Nitrogen, and total alkalinity and hardness as caco3 and magnasium Hardness and all other parameters required as per IS 10500:2012. test report be rendered and a record of the same to be submitted to department once in a month or whenever required or directed by the users and department depend upon the situation/quality of water.
Supply and fix Electric Shock treatment chart in three language (Hindi/English/Telugu) in PVC flex in size 2.00 x 1.50 metre with fixing arrangement on wall of installation including necessary fitment (As per sample), complete all as specified and directed.
Supply and fix plant/equipment description provided by department in PVC flex of size 2.00 x 1.50 metre with fixing arrangement on wall of installation complete including necessary fitment (As per sample) in required format with writing of pump details, pump capacity, dt set of work, complete all as specified and directed.
S&F 150W high efficient LED Flood light fixture, Aluminium Pressure Die Cast Housing (ADC12 alloy) alongwith mounting bracket for aiming, Luminaire system efficacy ≥100lm/W, System Lumens 15000lm, high purity polycarbonate /glass diffuser, with silicon gaskets for IP66 (No Glue) protection, IK08,name of the company or logo must be embossed, in built electronic driver with phase to phase protection at 440V for 8 hours with high voltage cut off and auto recovery features, Metal fully potted and encapsulated driver to protect against moisture with constant current, low/over voltage protection (under Voltage protection should survive Input Voltage Stress of 100V for 48 Hrs) duly wired up to terminal block, surge protection 4 kV and optional 10kV within the driver
Item No 82.00 contd--- compartment, IEC 60598 to be followed, driver efficiency >88%, power factor > 0.95, THD ≤10%, colour rendering index CRI >70, temperature range 0 to 45 degree centigrade, CCT: 5700K Luminaire and driver must be same make, LED used to be SMD LED, secondary optics is must for better light distribution,<5 MacAdam LED Type for better colour matching and to avoid colour shift, LED must be mounted on quality MCPCB to avoid multiple soldering and frequent failure of LED chip, LED Makes : Nichia/ Cree/ Osram/ Philips Lumiled, Lifetime of LED 50K hours @L70 B50 (As per TM21), photo biological safety report as per IEC 62471, Voltage range 120-270V AC including taking down existing street light fitting, complete all as specified and directed. MAKE : Phillips/Crompton/Wipro
Supply and laying of 3 core 2.5 sqmm copper cable on Existing Steel pole for the connection of street light from junction box to street light fitting including taking down existing cables, complete all as specified and directed.
Supply and fix pole Junction box for street light pole in size of 25x15x6 cm with inbuilt terminal for connection of cable including all connection and taking down old unserviceable one, complete all as specified and directed.
Taking down existing electric motor upto 7.5 HP Capacity, 3 phase 415V 50 cycles AC from foundations bed/coupling opening the motor, taking to workshop and removing the burnt windings cleaning the stator and rotor with cleaning agent rewinding the motor with appropriate gauge of super enamelled copper wire of same gauge and same no of turns of existing make insulating winding with existing class of insulation varnishing baking up including supply and replacement of base foundation nuts bolts same to site and re-installation of motor with suitable packing materials and connecting to the pump, testing the motor satisfactory performance, complete all as specified and directed. Note:Bearings shall be measured and paid separately under relevant item of BOQ
All as Srl Item No 85 above but for electric motor of 10 to 15 HP capacity
All as Srl Item No 85 above but for electric motor of 20 to 40 HP capacity
Taking down carefully the existing motor upto 7.5 HP Capacity from foundation bed for servicing by removing the coupling, cleaning the motor & stator body with cleaning agent, varnishing, to improve the insulation values reassembling and re-installing the motor with necessary bolts, nuts and washers and connecting the pump set, complete all as specified and directed. Note : Bearings shall be measured and paid separately under relevant item of BOQ
All as Srl Item No 88 above but for motor of 10 to 15 HP capacity
All as Srl Item No 88 above but for motor of 20 to 40 HP capacity
M&L for dismantling centrifugal pump of 30 to 40 HP coupled with electric motor 3 phase 415 volt,50 Hz of following capacities from the foundation bed for repairs by removing the coupling and foundation bolts etc. dismantling the complete pump and separate the serviceable and unserviceable parts. Replace the unserviceable parts/spares, reassembling and reinstall the pump with necessary bolts nuts and washers including cleaning and removing the scales and replacement of spare parts like impeller nut, keys, lock washer, gasket and greasing, reassembling coupling in position testing and commissioning in the pump set up to satisfaction level, complete all as specified and directed Note : Supply Only Spare parts shall be measured and paid separately under relevant items of BOQ
All as Srl Item No 91 above but for pump set of 12.5 to 20 HP capacity
All as Srl Item No 91 above but for pump set of 5.0 to 7.5 HP capacity
All as Srl Item No 91 above but for pump set of upto 5.0 HP capacity
Supply and fix in repairs pump set Star coupling upto 7.5 HP motor made out of mild steel including drilling holes and suitable size of nuts, bolts, complete all as specified and directed
All as Srl Item No 95 above but for motor of 10 to 15 HP capacity
All as Srl Item No 95 above but for motor of 20 to 40 HP capacity
Supply and fix in repairs terminal block of 6 terminals for Motor upto 7.5 HP Capacity, complete all as specified and directed
All as Srl Item No 98 above but for motor of 10 to 15 HP capacity
All as Srl Item No 98 above but for motor of 20 to 40 HP capacity
Supply only the bearings required during rewinding / servicing of motors having capacity upto 7.5 HP, complete all as specified and directed
All as Srl Item No 101 above but for motor having capacity of 10 to 15 HP
All as Srl Item No 101 above but for motor having capacity of 20 to 40 HP
Supply only Rubber Coupling of motors having capacity upto 7.5 HP, complete all as specified and directed
All as Srl Item No 104 above but for motor having capacity of 10 to 15 HP
All as Srl Item No 104 above but for motor having capacity of 20 to 40 HP
Supply only for following spare parts for centrifugal pump set up to 5 HP capacity, complete all as specified and directed.
Casing Ring
Latern Ring
Shaft sleeve DE/NDE
CI Gland covers with MS Studs
Ball Bearing
Supply only for following spare parts for centrifugal pump set up to 7.5 to 10 HP capacity, complete all as specified and directed.
Casing Ring
Latern Ring
Shaft sleeve DE/NDE
CI Gland covers with MS Studs
Ball Bearing
Supply only for following spare parts for centrifugal pump set up to 12.5 to 20 HP capacity, complete all as specified and directed.
Casing Ring
Latern Ring
Shaft sleeve DE/NDE
CI Gland covers with MS Studs
Ball Bearing
Supply only for following spare parts for centrifugal pump set up to 30 to 40 HP capacity, complete all as specified and directed.
Casing Ring
Latern Ring
Shaft sleeve DE/NDE
CI Gland covers with MS Studs
Ball Bearing
Supply only CI Impellers as per existing Model for the following capacities complete all as specified and directed
upto 7.5 HP Capacity
10 to 20 HP capacity
20 to 40 HP Capacity
Supply only Pump Shafts as per existing Model for the following sizes, complete all as specified and directed
upto 7.5 HP Capacity
10 to 20HP capacity
20 to 40 HP Capacity
Taking down carefully existing motor and pump set of capacity 5 to 12.5 HP from the unserviceable bed and taking up the complete MS bed from the PCC and cleaning and levelling the bed including new PCC work including with fabrication of new MS bed by using new MS work with foundation bolts and nuts suitable for mounting/re-erecting the pump and motor after necessary minor repairs complete with two coats of existing colour painting over a coat of red oxide and testing and commissioning up to satisfaction levels, complete all as specified and directed
All as Srl Item No 113 above but for Pump set having capacity of 20 to 40 HP
M&L for disconnecting / removing old unserviceable thermal over load relay from existing star delta starter and S&F over load relay of existing model for AC 415 V, 50 Hz, 3 phase up to 50 HP Capacity of electric motor, complete all as specified and directed.
M&L for disconnecting/removing the old unserviceable contactors from the starter and Supply and fix contactors as per existing model for AC 415 V, 50 cycles, 3 phase suitable for 20 to 30 HP capacity of electric motors, complete all as specified and directed.
All as Srl Item No 116 above but for electric motor having capacity upto 20 HP
M&L for disconnecting / removing the old unserviceable starters from the panel and supply and fix DOL starter for AC, 415V 50 Hz 3 phase suitable for Up to 20 HP capacity of electric motor, complete all as specified and directed.
M&L for disconnecting / removing the old unserviceable starters from the panel and supply and fix DOL starter for AC, 415V 50 Hz 3 phase suitable for 20 HP to 40 HP capacity of electric motor, complete all as specified and directed.
Supply and replace PVC cooling fan suitable for the existing motors of various capacity including testing and commissioning, complete all as specified and directed.
Supply and replace Nut & Bolts, Gland Bolts Eye bolts of different sizes complete all as directed including taking down the unserviceable bolts, complete all as specified and directed.
M&L for preparation and applying spray painting of existing colour for electric driven pumpset up to 10 HP capacity, complete all as specified and directed.
All as Srl Item No 122 above but for electric pumpset having capacity 12.5 to 40 HP
Supply, laying in trenches or fixing on wall or passing through pipe or in cable ducts, XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 4.0 core 16 sqmm size including taking out old un-serviceable cable, complete all as specified and directed.
All as Srl Item No 124 above but for of 3.5 core 25 Sqmm
All as Srl Item No 124 above but for of 3.5 core 50 Sqmm
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. Note: Punned thickness shall only be measured and paid.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat size 250mm x 150mm x 40mm for protection to cable in trenches, complete all as specified and directed.
Supply only stable bleaching powder (SP) (Calcium HypoChloride) Grade-I, Chlorine availability Min. 34%, stability 1/15 Max, moisture 0.3% Max etc Complete all as specified and directed.
Supply only Chlorine 56% to 70 % Calcium based granular disinfectant for water treatment, more stable for water treatment than chlorine gas and stronger than bleaching powder and sodium hypochlorite in 45 kg drums, complete all as specified and directed.
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
CHAMUNDESWARI ENTERPRISES
M/S EVEREST INFRA
M/s SIRI CONSTRUCTIONS
GVR CONSTRUCTIONS
M/s KAMADHENU ENGINEERING CONSTRUCTIONS
Prasad and Suresh Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .