Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹9.3 L+₹18,945 (2.08%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance HIGHEST | |
| 3 | Rejected-Technical SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical Not Recommended as not enlisted in b(iii) category of work |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
18 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI T C SHISHODIYA. DCWE (C)
MULTAN LINE ARMY AREA JODHPUR
Repair and maintenance of 11 KV Network and connected works including capacitors bamles/panels in sector A and B area including improvement of infrastructure at Army area Jodhpur
2020_MES_369840_3
CWE (A) JODH-71 OF 2020-21
Open Tender
Civil Works - Canal
Item Rate
150 days
GE(Army) Utility
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE(Army) Utility
₹30,000
Yes
17 Feb 2021
28 Oct 2020
19 Nov 2020
28 Oct 2020
18 Nov 2020
4 Nov 2020
60 days
Amount
Repairing of damaged/unserviceable gang operate devices 11 KV male & female contacts, flexible jumpers, MS jumper carrier and back connector plate incl cleaning and greasing of complete contacts of GOD unit, DO fuse unit and reluging of aluminium conductors connected to top & bottom contacts of GOD and DO units incl. welding and threading of operating rod mechanism complete making serviceable all as directed by Engr-in-Charge. Note:- (i) Necessary parts like knife, male/female contacts and aluminium conductor for jumpering, GI pipe and handle will be Measured and paid separately against respective item. (ii) Rates for Welding machine, threading arrangements, grease, jumper and binding wire deemed to be included in quoted rates.
Supply and fix male contact/moving contact blade complete suitable for 11 KV GOD vertical type. Make : JB or equivalent.
Supply and fix female contact/fix contact jaw complete suitable for 11 KV GOD vertical type. Make : JB or equivalent.
Supply and fix tinned copper flexible jumper 200/400 amps complete suitable for 11 KV GOD vertical type.
Supply and fix fixed top contact / L contact complete suitable for 11 KV GOD drop out fuse unit vertical type.
Supply and fix fixed bottom contact complete suitable for 11 KV GOD drop out fuse unit vertical type.
Supply and fix in replacement of locking handle with lock complete suitable for 11 KV GOD vertical type.
Supply and fix in replacement of GOD pipe from GOD to handle medium grade 25 mm bore dia complete suitable for 11 KV GOD vertical type.
Supply and fix male contact/moving contact pipe assembly complete suitable for 11 KV GOD Horizontal type.
Supply and fix female contact/fix contact assembly complete suitable for 11 KV GOD Horizontal type.
Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 150 mm height 150 mm dia for 11000 volts grade complete all as specified.
Supply and fix in replacement of post insulator porcelain, vitreous white brown or green for 11000 volts grade capacity complete all as specified and directed by Engr-in-Charge.
Dismantling of existing any type and any size of broken poles including dismantling of cross arms (channel/ angles) insulators and earth work complete all as directed at site. NOTE- (i) Rates includes demolition of concrete and making good. (ii) Dismantling of cross arms (Channels/angles) and insulators will be measured and paid seperately under respective item of schedule.
Material and labour for prestressed cement concrete poles 11 M long of size 152 mm x152 mm at top and 152 mm x 260 mm at bottom class-9, conforming to relavent latest IS including refixing of connecting items complete all as specified and directed by Engr-in-Charge on site. Note : - (i) PCC Work, excavation and earthwork will be measured and paid separately under relevant item. (ii) Refixing of cross arms (Channels/angles) and insulators will be measured and paid seperately under respective item of schedule. (iii) The PCC pole shall be marked with manufacturer name, IS number, class and CG etc.
M&L for Fabrication of bus bar on four pole structure complete using ACSR conductor, jumpring all incomer and out going feeders and connecting GO and DO with suitable length ACSR conductor including any type of insulators complete all as specified and directed by Engr-In - Charge at site. Note :- (i) ACSR conductor, 11 KV Pin/Disc insulator Nut, bolt and washer, all type of clamps of suitable size, binding material and aluminium lugs deemed to be included in quoted rates. (ii) Channels/angle iron will be measured and paid separately under relevant item.
Material and labour for steel structure, cross arms bracing supports ,clamps, back plates of any type, section incl. nuts, bolts, washers, welding ,bending cold or hot in any size and shape all as directed Including two coats of aluminium paints over a coat of red oxide primer incl preparation of surface all as directed by Engr-in-charge.
Material and labour for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in elect plate NO-1 of SSR-part -1 including stay wire of appropriate size all as specified and directed by Engr in charge. Note : - Excavation, PCC, stay wire, Loop insulator, clamps etc shall be measured and paid seperately under respective items.
Surface dressing n.exc 15 cm deep in any type of soil and site clearance in soft and loose soil all as directed by EIC.
Excavation in trenches not exceeding 1.5m wide and n.exc. 1.5m in depth for laying of cable and foundation in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) and depositing at a distance not exceeding 50m where directed.
Returning filling in soil and well ramming in layers n. exc. 25cm including spreading, leveling and watering all as specified and directed.
M&L for river sand cushioning to underground cable for cushioning 8cm below the cable and 15cm above cable all as specified and directed. Note: Punning down thickness of sand cushioning shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1, flat size 300 mm x 180 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection.
Re-laying of 40 to 50mm thick roughly hammer dressed stone slab 25 to 30cm wide and not less than 60cm long laid dry and abuting each other with gap between adjacent slab not exceeding 10mm over U/G cable for cable all as directed.
M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of HDPE pipe of 100 mm bore dia complete all as specified and directd by EIC.
M&L for GI tubing light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall including claps, nut bolt etc all as specified and directed of size 100 mm. Make: Prakash surya/ Jindal/ TATA.
Supply, fixing and lay of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor HT 11 KV (E) volts grade cross sectional 95 sq mm 3.0 core, laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable OH conductor all as specified and directed.
Material and labour for end jointing kit, indoor type heat shinkable, 95 sqmm to 185 Sqmm, 3 core suitable for 11 KV (E), XLPE insulated electric power cable complete all as specified and directed.
All as per item No 28 above but outdoor type.
All as per item No 28 above but straight through.
Under ground Cable Testing / fault detection by authorised agency with Computerised Fault Detection Van complete to find the fault location for 33/11 KV rated UG cables as directed by Engineer in Charge at site. Note :- Any excavation and earth work and cable joint work involved will be measured and paid separately against respective item.
Supply and fix switch air break gang operated triple pole mechanically operated mounted on insulator (09 insulators) and steel frame with operating mechanism including spring loaded mechanism set of three working from ground level, including locking arrangement of Current rating up to 200 Amps (Vertical type), 11000 volt.
All as per item No 32 but (Horizontal type), 11000 volt.
Supply and fix in replacement swing out expulsion fuse assembly single pole (drop out fuse) for 11000 Volts of cap. 100 Amps complete with MS channel, post insulators etc all as specified. Make : BHEL/Pactil/JB
Material and labour for Cement concrete (1:2:4) type C-1 using 20 mm graded stone aggregate for foundation of pole /struts/stay assembly etc complete all as directed by EIC
Material and labour Cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, all as directed by EIC.
M&L for Trimming and pruning of one tree complete cutting of all branches of any dia but not exceeding 3" girth up to a safe distance from the over head lines complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed by AGE EM-III. NOTE:- 1. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to incl in the rate quoted for the job. 2. Proper shut down will be taken by the authorised rep only. 3. T&P / Vehicle mounted Telescopic Ladder required for carry out the work at a height up to 15 meter will be issued to contractor under Schedule 'C' as demanded by contractor.
Excavation in trenches not exceeding 1.5m wide and exceed 1.5m in depth for errection of PCC pole in hard/loose soil complete all as specified and directed.
Supply and fix in replacement of gap less metal oxide type Lightning Arrestor (LA), 9.0 KV grade discharge current 5 KA, distibution class conforming to IS-3070 including taking out old U/S LA assembely complete all as specified and directed by Engr-in-Charge.
Supply, fixing & stringing of ACSR conductor on poles with jumpring and binding with aluminium conductors and in yards with and incl aluminum connectors of required shape and suitable for conductor size all as directed by Engr-in-Charge.
Supply and fixing in replacement of Danger notic plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, whith letters, figures and conventional skull and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for HT pole of size 25 x 20 cm size including complete fixing arrangement with iron stip 25mm x 3mm with nut, bolts and paints etc complete all as specified and directed by EIC.
Material and labour for replacement of cradles, hexagonal/rectangular fabricated with GI earth wire 4 mm dia and cradles made out of 3.15 mm dia GI wire for guard netting complete all as specified and directed by Engr-in-Charge.
Restringing only of ACSR conductor straightening properly on insulators and binding with aluminium taps /binding wire /conductor jumper etc all as directed by Engr-in-charge complete of any size
M&L for upgradation of four pole structure including dressing, clamping of HT cable through suitable size of GI protection pipe, fixing of GI earthing strips, burring of all cable loops, any earth work etc with thighting or replacement of all jumpers, Danger notice boards, Anti climbing devices at all Two and four pole structures complete including two coats of aluminium paints over a coat of red oxide primer on steel member/structrure all as specified and directed by Engr-in-Charge. Note : - (i) GI pipe, ACSR conductors, Danger notice plates, MS anti clembing devices, etc shall be measured and paid separatelyunder respective items. (ii) Earth work, surface dressing etc deemed to be included in quoted rates. (iii) Proper shut down will be taken by the authorised rep only. (iv) T&P / Vehicle mounted Telescopic Ladder required for carry out the repair work at a height up to 15 meter will be provided by contractor without any extra cost.”
M&L for taking out existing cable from trench and relaying the same after rectification of fault/ jointing of cable as directed by Engr-in-charge. Note : Excavation, earthwork to be included in quoted rate.
Material and Labour for Aluminium painting of steel Tubular/Rail poles 11mtr long including cross arms, clamps etc complete all as directed by EIC .
M&L Painting of PCC pole structures complete cross arms and channels of HT line feeder with Silver Al paint all as directed by EIC.
M&L for Painting of PCC poles poles two pole structures complete incl cross arms and channels of HT line feeder with Silver Al paint all as directed by EIC.
M&L Painting of PCC poles four pole structures complete cross arms and channels of HT line feeder with Silver Al paint all as directed by EIC.
Material and labour for GI strip laid in trenches / fixed on wall of size 32 mm x 6 mm laid for inter connecting on pole /extension in earthing including excavation and earth work complete all as directed at site.
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .