Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | ₹2.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.2 L+₹2,009 (0.93%)Rejected-Finance LOCATION HIMACHAL PRADESH HP | KANGRA | HIMACHAL PRADESH | 176219 | ₹2.2 L+₹2,009 (0.93%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.2 L+₹2,260 (1.04%)Rejected-Finance VILLAGE KHURAHAL PO DHAWAL TEHSIL SUNDER NAGAR DISTT MANDI HP | ₹2.2 L+₹2,260 (1.04%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Mahender Singh L3 | Prem Chand L2 | NOKH RAM L1 |
|---|---|---|---|---|---|---|
| 1.00 | Rewinding of 20H.P Centrifuge motor with copper wire complete in all respect & entire satisfaction of Engineer-in-charge. | 2 | No | 30,500 ₹61,000 | 30,050 ₹60,100 | 30,000 ₹60,000 Lowest |
| 2.00 | Repair of 20 H.P OCB Starter servicing such as all loose connection are to be checked/tightened, contactors are to be cleaned/replaced, burnt lead to be replaced, also submersible pump motor coil resistance,supply voltage,full load current, pump pressure, abnormal sound with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge. | 1 | No | 5,555 ₹5,555 | 5,550 ₹5,550 | 5,500 ₹5,500 Lowest |
| 3.00 | Providing and fixing Heavty Duty Main Switch 63 amp. With wire Double /triple polen with neutral TPN side handle operated iron clad type (confirming to IS: 13947(part-10 1993 -IEC 947(part-3) type BSP/BSG with sheet etal enclosure complete in all respect in all leads and lifts) | 4 | No | 4,244 ₹16,976 | 4,210 ₹16,840 | 4,200 ₹16,800 Lowest |
| 4.00 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as ( 100amp.) | 3 | No | 6,244 ₹18,732 | 6,220 ₹18,660 | 6,200 ₹18,600 Lowest |
| 5.00 | Providing and fixing of ampare meter complete in all respect in all leads and lifts) | 2 | No | 980 ₹1,960 | 958 ₹1,916 | 950 ₹1,900 Lowest |
| 6.00 | Providing and fixing of voltage meter complete in all respect in all leads and lifts) | 2 | No | 910 ₹1,820 | 900 ₹1,800 Lowest | 920 ₹1,840 |
| 7.00 | Providing supplying and filling Pump oil complete in all respect with in all leads and lifts .. | 15 | Ltr. | 410 ₹6,150 | 400 ₹6,000 Lowest | 420 ₹6,300 |
| 8.00 | Repair of 20 H.P Submersible Pump set servicing overhauling the pump bearings are to be checked/cleaned and properly greased or replaced with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge | 1 | Each | 12,500 ₹12,500 | 12,200 ₹12,200 | 12,000 ₹12,000 Lowest |
| 9.00 | Providing and fixing fixed MS nut & bolt complete in all leads and lifts. | 48 | Each | 66 ₹3,168 | 64 ₹3,072 Lowest | 65 ₹3,120 |
| 10.00 | Providing and fixing varnish PVC tape & fire proof sleeves with packing streeps complete in all leads and lifts. | 10 | Each | 38 ₹380 | 34 ₹340 Lowest | 35 ₹350 |
Tender Value
₹1.4 L
EMD Value
₹2,817
Closing Date
10 Sept 2025, 5:00 pmClosed
Executive Engineer Jal Shakti Division Larji
Executive Engineer Jal Shakti Division Larji
(SH- Repair of submersible motor and pump and other accessories) LWSS Hat , LWSS Lower Piyashni, LWSS Bajaura)
2025_HPIPH_113399_2
NIT No. 6479-6578 dt. 29-08-2025
Open Tender
Civil Works
Item Rate
30 days
Bajaura
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EE Larji
₹2,817
29 Jul 2026
30 Aug 2025
11 Sept 2025
30 Aug 2025
10 Sept 2025
30 Aug 2025
Amount
Rewinding of 20H.P Centrifuge motor with copper wire complete in all respect & entire satisfaction of Engineer-in-charge.
Repair of 20 H.P OCB Starter servicing such as all loose connection are to be checked/tightened, contactors are to be cleaned/replaced, burnt lead to be replaced, also submersible pump motor coil resistance,supply voltage,full load current, pump pressure, abnormal sound with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge.
Providing and fixing Heavty Duty Main Switch 63 amp. With wire Double /triple polen with neutral TPN side handle operated iron clad type (confirming to IS: 13947(part-10 1993 -IEC 947(part-3) type BSP/BSG with sheet etal enclosure complete in all respect in all leads and lifts)
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as ( 100amp.)
Providing and fixing of ampare meter complete in all respect in all leads and lifts)
Providing and fixing of voltage meter complete in all respect in all leads and lifts)
Providing supplying and filling Pump oil complete in all respect with in all leads and lifts ..
Repair of 20 H.P Submersible Pump set servicing overhauling the pump bearings are to be checked/cleaned and properly greased or replaced with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge
Providing and fixing fixed MS nut & bolt complete in all leads and lifts.
Providing and fixing varnish PVC tape & fire proof sleeves with packing streeps complete in all leads and lifts.
Providing and Fixing Flange Gasket Various dia complete in all respect with in all leads and lifts ..
Providing and Fixing Stay Wire .7/3.25mm IS Code 73121030 with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge.
Providing and Fixing of Current Transormer Ratto 100/15A Frco 50H2 srno1/13/679010/117 with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge
LWSS Lower Piyashni
Repair of 50 H.P OCB Starter servicing such as all loose connection are to be checked/tightened, contactors are to be cleaned/replaced, burnt lead to be replaced, also submersible pump motor coil resistance,supply voltage,full load current, pump pressure, abnormal sound with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge.
Providing and fixing wall bearing SKF 6309 to RS 1/3 complete in all leads and lifts.
Repair of 17.6 H.P Starter panel servicing such as all loose connection are to be checked/tightened, contactors are to be cleaned/replaced, burnt lead to be replaced, also submersible pump motor coil resistance,supply voltage,full load current, pump pressure, abnormal sound with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge
Providing and fixing of Copper Cable 3 core, 4 sqmm as per IS-674-Part-II-1964 suitable for above pump set from starter to pump set subject to the approval of HPSEB authority as per the satisfaction of Engineer-in-charge.
LWSS Bajaura
Rewinding of 17.50H.P Centrifuge motor with copper wire complete in all respect & entire satisfaction of Engineer-in-charge.
Repair of 17.50 H.P Submersible Pump set servicing overhauling the pump bearings are to be checked/cleaned and properly greased or replaced with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge
Repair of 17.50 H.P Starter panel servicing such as all loose connection are to be checked/tightened, contactors are to be cleaned/replaced, burnt lead to be replaced, also submersible pump motor coil resistance,supply voltage,full load current, pump pressure, abnormal sound with in all leads and lifts as per the entire satisfaction of Engineer-in-Charge
Dismantling, assembling and testing of Pump & motor at site of work and carriage upto workshop and return to pump house, ferro installation complete in all respect & entire satisfaction of Engineer-in-charge.( LWSS Hat & LWSS Bajaura (Motor and Pump)
Prem Chand (BID ID -552325)
Mahender Singh (BID ID -552320)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .