| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC PREM SAROVAR HOTEL NAINITAL 263 001 UTTARAKHAND | NAINITAL | UTTARAKHAND | 263001 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹13.8 L+₹27,186.91 (2.00%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹14.0 L+₹42,076.63 (3.10%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
₹13.7 L
EMD Value
₹27,360
Closing Date
25 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) Bhowali
AGE (I) (AF) Bhowali PO Bhowali Nainital 263139
PROVISION OF SIGNAL BLOCK FOR SDR BUILDING AT LKT AT AFS BHOWALI
2023_MES_591979_1
8063/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN LKT Bhowali
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) (AF) Bhowali
₹27,360
Yes
1 Jul 2023
28 Apr 2023
27 May 2023
28 Apr 2023
25 May 2023
13 May 2023
28 Apr 2023 - 10 May 2023
Amount
M&L for Surface excavation of soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and getting out in soft/disintegrated rock complete all as specified and as directed.
All as per item No. 2 above but depth exceeding 1.50 metre and not exceeding 3.0 metre complete all as specified and as directed..
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm depth in soft/disintegrated rock complete all as specified and as directed.
Removing excavated soft/disintegrated rock exc 250 m but n.exc 500m and depositing where directed
M&L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M<reating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M&L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L for broken stone or boulders hardcore of gauge n exc 63mm , deposited, spread and levelled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed..
M&L for Plain Cement concrete 1:4:8 (type D2) (40mm graded aggregrade) in foundations, filling and mass concrete complete all as specified and directed..
M&L for use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter Rough finished flat complete all as specified and as directed.
M&L for use and waste form work to rough finished square, rectangular surfaces of concrete sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for use and waste form work to soffits of suspended slabs such as landings and similar work; not exceeding 200mm thick rough finished surface of flat concrete (Horizontal or sloping) complete all as specified and as directed.
M&L for use and waste form work to sides and soffits of floor or roof beams, Landing beams etc. rough finished flat concrete surfaces complete all as specified and as directed.
M&L for use and waste form work to edges of concrete flats, treads, breaks in floors and roofs n exc 20cm wide and similar work etc complete all as specified and as directed.
M&L for use and waste formwork to chullah hoods, chajjas, troughs and similar items incl edges complete all as specified rough finished flat surfaces of concrete complete all as specified and as directed..
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
M&L for RCC, M-25 (Design Mix) in foundations, filling and mass concrete , Plinth beam and finished surface concrete flat complete all as specified and as directed.
M&L for RCC, M-25 (Design Mix) in Columns, pillars, piers, posts and struts and finished conctrete surface flat complete all as specified and as directed.
M&L for RCC, M-25 (Design Mix) as in slab supported on walls, beams and column in floors, roofs, landings, balconies shelves etc and finished conctrete surface flat complete all as specified and as directed.
M&L for RCC, M-25 (Design Mix) in roof beams ,floor beam etc and finished conctrete surface flat complete all as specified and as directed.
M&L for RCC, M-25 (Design Mix) in Chajjas and finished concrete surface flat complete all as specified and as directed.
M&L for earth work under floors with soil including watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as specified and as directed.
M&L for 40 mm thick cement concrete ,1 :2:4 type B-1 using 20 mm graded stone aggregate mixed with WPC as per manufacturer's instruction as in DPC work complete all as specified and directed. Note :- WPC shall be measured and paid seperately uder respective item of BOQ.
M&L for rendering 15 mm thick in CM 1:6 on brick/concrete on fair surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on external sufaces on other than fair faces of brick work or concrete surfaces mixed with @2% WPC by weight of cement and finished the surface even and fair complete all as specified and directed. Note :- WPC shall be measured and paid seperately uder respective item of BOQ.
M&L for rendering 5 mm thick in CM 1:3 as in ceilings and finished surface even and smooth without using extra cement complete all as specified.
Supply only WPC complete all as specified and directed
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of primer over 2 mm to 3 mm thick wall care putty complete as specified.
M&L preparation of newly plastered surface and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation on newly plastered surface of ceilling and applying Three coats of white wash complete all as specified and directed.
M&L for 15mm thick cement plaster (1:3) with using WPC and finished the surface even and smooth with using extra cement on roof slab complete all as specified and directed. Note :- WPC shall be measured and paid seperately uder respective item of BOQ.
Applying one coat of hot blown bituminous primer @ 0.40 kg per sqm on plastered surfaces complete as directed
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed.
M&L for APP based polymeric membrane, 3mm thick(min), weighing 3.5 kg/sqm reinforced with polyster non wooven fabric matt weighing not less than 160 gms/sqm) laid on primed surface complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded aggregate as in sub base and finished rough and fair complete all as specified and directed.
M&L flooring with 25 mm thick PCC (1:2:4), type B-0 using 20 mm graded stone aggregate and finished without extra cement complete all as specified and directed.
S&F 3 mm thick Glass dividing strips of 22mm width inserted in position, conform to design complete all as specified and directed.
M&L 75 mm thick cement concrete (1:3:6) type C-2, using 40 mm graded stone aggregate as in plinth protection and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for forming construction(Dummy) joint 65 mm deep x 10 mm wide, and filled with sealing compound grade 'A' complete all as specified and directed.
S&F vitrified ceramic tiles 10mm thick of light shade (Square/rectangular) polished, area of each tiles exc 0.18 Sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slury and pointed in white or coloured cement to match over 15mm thick cement screed bed in CM 1:6 complete all as specified and directed.
Ditto all as per item No.46 here in before but as in skirting/dado including 10mm backing coat in CM (1:4) complete all as specified and directed
S&F steel ventilators with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S&F Pressed steel frames (Size 105x60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc complete all as specified.
M&L for cement concrete type C1 1:3:6 (using 20 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, fixing of holdfast, plinth courses , string courses, lacing courses parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, filled inside the frame, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as spectified and directed.
M&L for 40 mm thick Flush shutters, solid core construction, with partical board core and plywood face panels, commercial type on both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel and iron surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and fixing of MS butt hinges, medium weight, cold rolled of size 100 mm complete all as specified and directed.
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F of 150 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
S&F mild steel plates (Plain or Chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) 'B' quality complete all as specified and directed.
S&F of 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work stone/boulders masonry build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for point wiring complete with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface for existing pipe) and supply and fixing concealed PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting modular switch, socket etc (with inner and outer plate) including with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
(i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iii) One 3 pin socket outlet, 6 Amp on “independent board”
All as per item No. 62 here in above but point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make: Cat part of Philips: BN108C LED 40S PSU CDL WH or equivalent of Crompton, Havells
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make: Cat part of Philips: BRP409 LED CW 036 MR FG S1 PSU GR or equivalent of Crompton, Havells
Supply & Fixing modular switch 1 way 6A,1 module, 240 Volt, single pole , ISI marked conforming to IS 3854 style single colour series with complete all as specified and directed. Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply & Fixing modular socket, 6A - 2/3 pin combined 2 module, 240 Volt AC, flush type, style single colour series with complete all as specified and directed. Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply & Fixing modular Switch socket Combination 16A, 6 pin, 3 module, 240 Volt AC, style with single colour series"complete all as specified and directed. Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply & Fixing FASHION ceiling rose with colour ring. Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply and fixing of White cover plate with frame, 1 module as specified and directed at site .Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply and fixing of White cover plate with frame, 6 module as specified and directed at site Make: LEGRAND/ANCHOR/ORIENT/HAVELLS
Supply only SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Cat No. Indo Asian optipro/Schneider (Electric)/Legrand as approved by AGE (I).
Supply & Fixing Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning as specified and directed. Make - Schneider Electric/Legrand/L & T.
Supply only MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.Make -Schneider Electric/Legrand/L&T.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating 1.5 ton and EER 3.2.of capacity Hot and Cold Split Inverter AC as shown and specified and directed.Make: O-GENERAL, Carrier,voltas, Cat part : Daikin- FTHT50UV16V Copper Condenser
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed. Make: V-Guard, Blue Bird, Microtek, IFB or Equivalent
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long including necessary fixing arrangement on suitable size of PCC block complete all as specified and directed.
Supply and fixing gun metal Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed .
Supply and fixing of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip 20x3 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply & fix aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductor and down conductors above ground all as specified and directed by Eng- in- Charge
Supply and fix GI pipe 40 mm bore light grade all as speciifed and directed at site .
M&L Cement concrete (1:2:4), type B-1,(using 20 mm graded stone aggregate as in coping ,bed block, kneelers and set in cement mortar(1:4) etc all as specified and directed .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 25 sq mm 4 core. MAKE: HAVELLS/POLYCAB/KEI/FINOLEX
Supply and laying GI steel tubing 25 mm bore medium grade complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
M&L for sand cushioning to under ground cable provided with layer of sand complete all as specified and as directed by Engr-in-charge
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and directed.
M&L for Chemical earthing with copper earth strip 32x6 mm and copper plate as per IS:3043 900 mm x 600 mm x 5.0 mm thick buried directly in ground (earth pit not less than 4.0 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 32 mm x 6 mm as earthing lead protected by GI pipe light grade 50 mm bore for protection of GI earth strip and testing of earth resistance complete including earth work, PCC pit, RCC cover etc all as specified and directed. Note : Copper Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate and beyond 7.5 metre, the same shall be measured and paid separately.
M&L for earth continuity conductor 32x6 mm copper strip along with suitable size insulator as adequate distance and fixe to wall or resses or chasses or burried in ground or drawn in floor/ wall/ surface with insulation with insulator and fixed on surface of wall all as specified and directed.
NOORI ENTERPRISSES
BHUWAN SINGH ADHIKARI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .