RequiredExperience with Government Bid to RA enabled No AC SPV Deep Well (submersible) Pumping Systems ( 10 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Solar Deep well (submersible) Pumping Systems: With AC Induction Motor Pump Set and a suitable Inverter Solar Photovoltaic (SPV) Water Pumping Systems comprising PV Array
RequiredSubmersible Pump Set
RequiredMPPT(Maximum Power Point Tracke)
RequiredInverter for A.C. Motors
RequiredElectronic Protections
RequiredInterconnect Cables * 1/9 and “On-Off” switch are basically for “Irrigation” applications. However
Requiredthese may also be used for “Drinking Water Applications wherever such capacities are required” Conformity to Indian Standrad for Solar Deep well (submersible) Pumping Systems Ministry of New and Renewable Energy
RequiredJawaharlal Nehru National Solar Mission
RequiredSolar Photovoltic Water Pumping System -2015-16 * Model Number as per MNRE specification Model-IV Model-IV Capacity of Solar PV Water Pumps with PV module 3000 Wp 3000 Wp PV ARRAY Operation of SPV Pumping System The SPV water pumping system should be operated with a required PV array capacity measured under Standard Test Conditions (STC). * Number of modules in series and parallel could be used to obtain the required PV array power output 10 * The power output of individual PV modules used in the PV array
Requiredunder STC (in Watts peak(Wp)) 325 * Source of PV Module Indigenously produced PV module (s) containing mono/multi crystalline silicon solar cells * PV module certification Certificate as per IEC 61215 specifications or equivalent National or International Standards * Safety Qualification Testing Modules must qualify to IEC 61730 Part I and II for safety qualification testing * 2/9 Efficiency of the PV module (%) 16.8 * Fill factor for PV module(%) 85 * The terminal box on the module should have a provision for “Opening” for replacing the cable
Requiredif required Yes * Dimension of PV module (mm x mm x mm) - * Marking On PV module Name Plate fixed inside the module which will give: 1. Name of the Manufacturer or Distinctive Logo 2. Model Number 3. Serial Number 4. Year of manufacture * Motor Pump Set Types of Submersible pump set BIS Marked Submersible Pumpsets to IS:8034 latest for use in borewells for handling clear cold water having ISI Marked motor to IS:9283 latest of wet type for continuous rating synchronous
RequiredCat egory-B
RequiredDuty Type-S1 * Submersible motor pump with controller Capacity 3 1
Required2
Required3
Required5
Required7.5
Required10 Power Supply Three Phase AC through suitable Variable Frequency Drive(VFD) * Numbers of poles of motor 2 * Motor speed(rpm) 2740 * Bore Size 150 * Delivery Size 50 * Suction Head 50 * The suction/delivery pipe (GI/HDPE)
Requiredelectric cables
Requiredfloating assembly
Requiredcivil work and other fittings required to install the yes
Requiredinclusive * 3/9 Motor Pump set Material of Suction Pipe ISI Marked HDPE Pipe to IS 4985 * Length of Suction Pipe 70 * Material of Delivery Pipe ISI Marked HDPE Pipe to IS 4985 * Length of Delivery Pipe 500 * All parts of the pump and the motor of the submersible pumps should be made of stainless steel Yes * Pump and all external parts of motor used in submersible pump which are in contact with water
Requiredare of stainless steel Yes * Marking on Motor pump The following details should be marked indelibly on the motor pump set a) Name of the Manufacturer or Distinctive Logo. b) Model Number. c) Serial Number. * MOUNTING STRUCTURES AND TRACKING SYSTEM Mounting on metallic structures The PV modules should be mounted on metallic structures of adequate strength and appropriate design * Mounting Structure Type Pole type structure * Strength of mounting structure suitable to withstand load of modules and high wind velocities up to 150 km per hour * The support structure used in the pumping system should be hot dip galvanized iron with minimum 80 micron thickness Yes * Tracking system Manual Manual Arrangement for seasonal tilt angle adjustment For manual tracking
Requiredarrangement for seasonal tilt angle adjustment and three times manual tracking in a day should be * 4/9 provided Inverter for Motor Yes * Remote Monitoring of Pump Provision for remote monitoring of the installed pumps must be made in the controllers or the inverters either through an integral arrangement or through an externally fitted arrangement * Provision to ascertain the daily water output
Requiredthe power generated by the PV array
Requiredthe UP TIME of the pump during the year
RequiredNumber of days the pump was unused or under breakdown/repairs Yes * ELECTRONICS AND PROTECTIONS Maximum Power Point Tracker (MPPT) Maximum Power Point Tracker (MPPT) should be included to optimally use the Solar panel and maximize the water discharge. * Inverter to operate an AC Pump Yes * IP protection for Inverter to operate an AC Pump The inverter must have IP 54 protection or must be housed in a cabinet having at least IP54 protection. * Adequate protections should be incorporated against dry operation of motor pump set
Requiredlightning
Requiredhails and storms Yes * Full protection against open circuit
Requiredaccidental short circuit and reverse polarity should be provided Yes * ON/OFF SWITCH A good reliable switch suitable for AC/DC use is to be provided. Sufficient length of cable should be provided for interconnection of the * 5/9 PV array
RequiredController Inverter and the motor pump set. Spares Required Spares for trouble free operation during the Warrantee period should be provided along with the system. * OPERATION AND MAINTENANCE MANUAL An Operation and Maintenance Manual
Requiredin English and the local language
Requiredshould be provided with the solar PV pumping system. The Manual should have information about solar energy
Requiredphotovoltaic
Requiredmodules
RequiredAC motor pump set
Requiredtracking system
Requiredmounting structures
Requiredelectronics and switches. It should also have clear instructions about mounting of PV module
RequiredDO's and DONT's and on regular maintenance and Trouble Shooting of the pumping system. Name and address of the person or Centre to be contacted in case of failure or complaint should also be provided. A warranty card for the modules and the motor pump set should also be provided to the beneficiary. * PERFORMANCE Shut Off Dynamic Head 75 75.0 Water Output on a clear sunny day with three times tracking of SPV panel
Requiredunder the “Average Daily Solar Radiation” 57
Required000 litres per day from a total head of 50 meters 57
Required000 litres per day from a total head of 50 meters Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a 90 liters of water per watt peak of PV array * 6/9 suitable Inverter from a Total Dynamic Head of 10 metres and with the shut off head being at least 12 meters Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a suitable Inverter from a Total Dynamic Head of 20 meters and with the shut off head being at least 25 metres 45 liters of water per watt peak of PV array * Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a suitable Inverter from a Total Dynamic Head of 30 metres and the shut off head being at least 45 meters 32 liters of water per watt peak of PV array * Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a suitable Inverter from a Total Dynamic Head of 50 metres and the shut off head being at least 70 meters 19 liters of water per watt peak of PV array * Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a suitable Inverter from a Total Dynamic Head of 70 metres and the shut off head being at least 100 meters NA * Minimum water output from a Solar PV Water Pumping System For AC Induction Motor Pump Set with a suitable Inverter from a Total Dynamic Head of 100 meters and the shut off head being at least 150 meters NA * 7/9 CERTIFICATION BIS CM/L number and validity of ISI marked Submersible Pump - * Availability of Type Test Report to prove conformity of parameters as per MNRE specification form MNRE empanelled for solar pump laboratory Yes * Test Certificate No and Date - * Name of the Lab where test Conducted - * Test Report to be furnished to the buyer on demand Yes * The type of pump set used must match the total dynamic head requirement of the site Moreover
Requiredit should be appropriately tested and certified by the authorized test centres of the Ministry to meet the performance and water discharge norms Yes * Scope of Supply with errection and commissioning at consignee end * Warranty The PV Modules must be warranted for output wattage
Requiredwhich should not be less than 90% at the end of 10 years and 80% at the end of 25 years. The whole Pumping system including pump shall be warranted for 5 years. * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents