Loading…
Loading…
Tender ID
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
30 Mar 2026, 6:00 pmClosed
Executive Engineer, RANDER DIVISION
Tender for RMU Installation, Testing and commissioning of 11/22KV, SCADA Compatible, RRLL/RRL type-3/4 Way, RMU including Construction of plinth for RMU as per approved drawing by DGVCL at VARIOUS sub division under RANDER Division.
288382
DGVCLSDPLN/0067/03/2026 Approved Date: 20-03-2026
Open
Electrical - All
Works
Surat
3 documents required · 3 mandatory
₹1,180
SURAT
₹20,000
20 Mar 2026
20 Mar 2026
20 Mar 2026
30 Mar 2026
20 Mar 2026
Name of Work:Tender for Installation, Testing and commissioning of 11/22KV, SCADA Compatible, RRLL/RRL type-3/4 Way, RMUincluding Construction
of plinth for RMU as per approved drawing by DGVCL at VARIOUS sub division under RANDER Division.
SR.NO DESCRIPTION UNIT RATE IN RS QTY
1 9925000001 Labour charge for excavation of cable Meter
trench of 400mm width x 1200mm depth, in any type of soil for laying of cable
of size up to 240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
2 9925000002 Labour charge for excavation of cable Meter
trench of 600mm width x 1200mm depth, in any type of soil for laying of cable
of size up to 240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
3 9925000003 Labour charge for excavation of cable Meter
trench of 400mm width x 1500mm depth, in any type of soil for laying of cable
of size up to 240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench leng th is to be considered
4 9925000004 Labour charge for laying of 11kV / 22 kV Meter
XLPE Cable of size up to 240 mm2 & preparation of sand layer 100mm thick, in the
cable trench & covering the cable with 150 mm dia (Inner), thickness 25 mm,
meter long RCC half round muffs and providing and fixing of 4inch width yellow
colour polyethylene tape with printing"CAUTION ELECTRIC CABLE BELOW' at
0.75 m depth from ground surface after laying cable in trench. This will provide
indication that electric cable is passing underground so as to protect cable from
mechanical injuries, refilling the same, as per Instruction of E gineer in Charge
5 9925000005 Labour charge for horizontal drilling Meter
using Auger machine without damage to surface road at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green color, 110mm 0.D. 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984- 1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The detail map obtained from HDD machine
and excel sheet hard and soft copy) indicating the respective depth and distance
from adjacent landmark for each segment for HDD is must require to be submitted.
HDD to be carried out at depth 1.5 mtrs to 2.0 mtrs as per site conditions and as
er instruction of EIC.
6 9925000006 Labour charge for horizontal drilling Meter
manually without damage to surface road at max 2.0 mtrs depth & putting of
6.11 kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984- 1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site Condition
(excluding cost of pipe). The detail map and excel sheet (hard and soft copy)
indicating the respective depth and distance from adjacent landmark for each
segment of cable to be submitted. Drilling to be carried out at depth Minimum 1.2 mtrs
to 2.0 mtrs as per site conditions as per instruction of EIC.
7 9925000007 Supply of 6.11kg/cm2 , class-4,Green Meter
color, 110mm O.D. , 8.5 mm thickness
H.D.P.E. pipe confirms to IS 4984 and BIS certification for laying of
underground 11KV/ 22KV XLPE cable up to 240 mm 2 size.
8 9925000008 Labour work for RCC concreting on CMT
disputed location and repairing of damage portion of road crossing for the work
carried out for roads crossing as well as concreting & muffing of poles including all
9 9925000009 Providing & fixing concrete stone route No
marker of 300 mm width x 150 mm thick x 650 mm height embedded in earth at least
300 mm below & 350 mm above ground level respectively at distance approx.
meters along the length of cable. The RCC concreting (1:2:4) (all necessary
materials will be in bidder's scope) of route marker is to be carried out 300 mm
width x 150 mm thick x 300 mm below ground level as per instruction of EIC. The
route marker should be with name of company with approved yellow colour-DGVCL.
The distance from marker to cable and cable depth with feeder name etc., marked with
arrow sign is to be painted on it. The route marker is to be fixed at location
near to any fixed permanent location (not necessary to fix exact on top of cable) as
per instruction of EIC.
10 9925000010 Erection of D.P. (double pole) structure No
using 9 / 11 Mtr. RSJ pole with cable connection arrangement along with fitting
of necessary fabrication for 11KV cable including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
11 9925000011 Erection of Single pole structure using 9 No
/ 11 Mtr RSJ pole with cable connection arrangement along with fitting of
necessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of concreting & muffing of poles
12 9925000012 Erection of D.P. (double pole) structure No
using 8.0 Mtr. PSC pole with cable connection arrangement along with fitting
of necessary fabrication for 11KV cable including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of concreting & muffing of poles
13 9925000013 Erection of Single pole structure using No.
8.0 Mtr PSC pole with cable connection arrangement along with fitting of
necessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of
earth as per instruction of EIC. (Exclusive of concreting& muffing of poles
14 9925000014 Labour charge for erecting of 11kV / 22 per job
kV XLPE cable of size up to 240 mm 2 on DP Structure with fixing of 02 Nos polymer
cleats on top and middle part. Polymer cleats, nut bolts etc. fixing material to be
provided by contractor.
15 9925000015 Providing & fixing of 6.11kg/cm2 , perJob
class4,Green color, 110mm O.D. 8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and
BIS certification on the erected DP structure for the mechanical protection of
cable by inserting the cable inside HDPE pipe. The HDPE pipe shall be erected in such a
way that 300mm shall be below the ground level and the rest 2700 mm shall be
supported on the DP Structure with 01 No Polymer cleat. All materials including polymer
cleat and Nut bolt to be provided by contractor.
16 9925000016 Providing and fixing of pipe type earthing No
from 80 mm dia class-B GI pipe with pit to be filled with salt & coke and
construction of chamber as per DGVCL Drg. No. dg /100 for DP and cable. The earthing
pit should be joined with cable by G.I. strip of size 1" width & 2 mm thick. All
material GI pipe, Coke Salt etc will be supplied by bidder.
17 9925000017 Supply & fixing of heat shrink type end No
terminations (outdoor) for up to 11kV 3C x 185 mm2 size XLPE cable as per DGVCL
technical specification
18 9925000018 Supply & fixing of heat & shrinkable end No
terminations (outdoor) for up to 22 kV 3C x 185 mm 2 size XLPE cable ( as per DGVCL
technical specification)
19 9925000019 Supply & fixing of heat shrinkable type No
end terminations (indoor) for up to 11kV 3C x 185 mm 2 size XLPE cable as per DGVCL
technical specification
20 9925000020 Supply & fixing of heat & shrinkable end No
terminations (indoor) for up to 22 kV 3C x 185 mm 2 size XLPE cable as per DGVCL
technical specification
21 9925000021 Supply & fixing of heat shrinkable No
straight through joint for up to 11kV 3C x
185 mm 2 size XLPE cables as per DGVCL technical specification.
22 9925000022 Supply & fixing of heat shrinkable No
straight through joint type for up to 22kV 3C x 185 mm 2 size XLPE cable as per DGVCL
technical specification
23 9925000023 Labour charge for excavation of No
2100mm long x 1200mm wide x 1200 mm deep joint pits for installation of 11kV
/ 22kV Straight through joints as per instruction of engineer-in-charge & covering
the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half
round muffs & refilling same as per instruction of EIC .
24 9925000024 Providing and fixing of insulating bus No
bar, made from 11KV/22KV XLPE cable after removal of semi conducting layer and
applying of PVC heat shrinkable antitracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long barrel heavy duty up to
240 sq mm lugs, Aluminium bus connector. Taping with PGclamp for bus
conductor as per drawing and as per instruction of EIC. The Allurninium lugs and PG
clamp shall be covered with 11KV/22KV HT insulating tapes. (11KV/22KV XLPE
cable will be in scope of DGVCL while all other materials will
be in bidder's scope.
25 9925000025 Testing of cable at various points and commissioning the feeder as per No
instruction of engineer-in-charge.Test result shall be submitted by contractor with
26 9925000026 Preparation and submission of 6 (six) copies, of complete layout drawings with GIS Set
mapping as per actual cable routing showing road crossing, HDPE pipe sleeving,
jointing locations, markers etc.
27 9925000027 Providing and fixing of Sign Board at junction point Made out of 2 mm No
aluminium sheet size 750x300 mm (2.5 x 1 ft) rectangle, as per design,
pretreated with phosphate process and acid etching coated with one coat of epoxy
primer and two coats of best quality paints, reflectorized with Hi Intensity
retro — reflective sheeting as per the latest and frame fabricated from suitable size iron
angle. The Sign Board is to be fixed on the base prepared from channel and bracing
angles which is grouted by means of cement concreting of 1:2:4 for size of 300 mm
dia x 800 mm height (500 mm to be grouted in ground). The details to be displayed
on sign board will be given by InchargeEngineer. (a) Hi intensity Micro
prismatic Grade
28 9925000028 Providing and fixing of Sign Board (Danger Board) on Distribution No
Transformer Centers Made out of 2mm aluminium sheet size 300x300mm (1X1 ft)
as per design, pre treated with phosphate process and acid etching coated with
one coat of epoxy primer and two coats of best quality paints, reflectorized
with Hi-Intensity retroreflective sheeting as per the latest and frame fabricated
from suitable size iron angle. The Sign Board (Danger Board is to be fixed at the
location as per instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
29 9925000029 Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm No
aluminium sheet along with 1.0 mm dia aluminium binding wire for fixing of aluminium
tag near end termination joint at DP structure for identifying the cable. The details of
feeder i.e. 11 / 22 KV with feeder name should be punched on the tag by letter punch of
size 16 mm as per instruction of In-charge Engineer.
30 9925000030 Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x 240 Nos
mm2 size XLPE cable as per DGVCL technical specification.
31 9925000031 Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x 240 Nos
mm2 size XLPE cable as per DGVCL technical specification
32 9925000032 Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x 240 mm2 Nos
size XLPE cable as per DGVCL technical specification
33 9925000033 Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x 240 mm2 Nos
size XLPE cable as per DGVCL technical specification
34 9925000034 Supply & fixing of heat shrinkable straight through joint for 11kV 3C x 240 mm2 Nos
size XLPE cables as per DGVCL technical s ecification.
35 9925000035 Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x 240 Nos
mm2 size XLPE cable as per DGVCL technical s ecification
36 9925000038 Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRL Nos
type3 Way RMU including Two numbers of earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical specification.
37 9925000039 Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRLL Nos
type4 Way RMU including Two numbers of earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical specification.
38 9925000040 Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRL type-3 Nos
Way, RMU including Two numbers of earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical specification.
39 9925000041 Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRLL Nos
type-4 Way, RMU including Two numbers of earthings as per Drawing (material is in
bidder's scope) and as per DGVCL Technical specification.
40 9925000042 Construction of plinth for 11KV, RRL type- 3 Way( i.e Two numbers of Isolator & One Nos
number of Breaker) Ring Main Unit as per DGVCL's technical specification
mentioned in drawing no: Drg. 11kv-01. All required material will be supplied by
41 9925000043 Construction of plinth for 11KV, RRLL type4 Way (i.e Two numbers of Isolator & Two Nos
number of Breaker)Ring Main Unit as per DGVCL's technical specification
mentioned in drawing no:Drg. 11kv-02.AlI required material will be supplied by
42 9925000044 Construction of plinth for 22KV, RRL Nos
type- 3 Way (i.e Two numbers of Isolator & One number of Breaker) Ring Main Unit
as per DGVCL's technical specification mentioned in drawing no: Drg. 22kv-01.
All required material will be supplied by contractor.
43 9925000045 Construction of plinth for 22KV, RRLL type4 Way (i.e Two numbers of Isolator & Two Nos
number of Breaker)Ring Main Unit as per DGVCL's technical specification
mentioned in drawing no:Drg. 22kv-02.All required material will be supplied by
44 9925000046 Modifications e.g. Providing and fixing of Terminal protectors i.e. Re-use able boot (HT no
Side 11/22KV, LT Side 1.1KV) including 11/22 KV insulating taps and L.T.(I.I KV)
insulating taps ,Busbar, Tapping from Bus Bar (11/22 KV XLPE cable) through P.G.
Clamp for H.T. Jumper to D.O. Fuse to bushings of Transformer Center, providing
& Fixing of jumper and providing & fixing of Heat Shrinkable Anti Tracking CoreInsulating
Tubing (Insulation Level 11/22 KV) in H.T. jumper , Clamping arrangement of cable
support frame on both side of existing Over Head type Distribution Transformer
to utilize in Under Ground cable network as per drawing & as per instruction of
Engineer incharge. All live parts i.e. PGClamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixing of 11/22 KV HT insulating tapes. ( 11/22
KV XLPE cable will be in scope of DGVCL while all other materials will be in bidder's scope )
45 9925000047 Laying of any size of 11/ 22 KV XLPE/PILCCable in readymade trench or in open per cable
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole (Including all KM
47 Dismental OF 100MM2 AAAC CONDUCTOR KM
48 9926000064 Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns NO
minimum on XLPE Cable with single strand binding wire (including cost of binding
49 Supply and fixing of Suspenssion clamp to Hold the cable (J-Hook) no
Rates are exclusive of all taxes.
TDS, GST will be applicable as per Govt. rules and regulations.
Exe. Engineer (O&M)
% Above /Below of Estimate Amount DGVCL, Rander Division
Stamp/Sign of Contractor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.0 RMU Installation Schedule A.pdf
1.RMU INSTALLATION AT RND.pdf
Schedule B for RMU Installation at Rander Dn .pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .