Superintending Engineer
Superintending Engineer, Construction Circle, UPJN (Urban), Prayagraj
Augmentation of Pipari Nagar Panchayat Water Supply Scheme Dist. Sonbhadra
2026_UPJNM_1206276_1
765/AMRUT 2.0/614 dt. 28.10.2026
Open Tender
Civil Works
Percentage
NP PIPARI
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,600
EE, CD, UPJNU, MIRZAPUR
₹37.7 L
SE, CC, UPJN(U), Prayagraj.
7 Nov 2026
7 Nov 2026
4 Dec 2026
7 Nov 2026
3 Dec 2026
7 Nov 2026
13 Nov 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil Work | |||||
| 2 | Construction of Intake well
Detailed Investigation, Hydraulic & Structural Design with Proof Checking/Vetting from IIT (BHU), and Construction of RCC Intake Well-cum-Pump House (12.92 MLD Capacity) with Connecting Footbridge, Desludging System, Flow Meter, Ultrasonic Water Level Indicator, River Protection Works, Campus Civil Structures (Power Sub-Station Building, Meter Room, Security Guard Room, Boundary Wall, 4.0 m Wide CC Road, RCC Drain, Landscaping, and Campus Development) on Complete Turnkey Basis."
Detailed Scope & Technical Specifications:
1. Soil Investigation, Design & Third-Party Vetting (IIT BHU):
Conducting exploratory geotechnical sub-soil investigation including minimum 30 m deep borehole drilling below river bed level (or refusal up to hard bed rock as per IS 1892). Preparation of complete architectural, structural, and hydraulic designs, drawings, and design calculations for the Intake Well, Pump House, Bridge, PSS Building, Meter Room, Foundations, and Campus Structures. The contractor must get all hydraulic & structural designs and structural drawings vetted/proof-checked by IIT (BHU) Varanasi at his own cost and obtain statutory approvals from the Engineer-in-Charge before commencing work at site.
2. Cofferdam, River Diversion & Comprehensive River Protection Works:
Construction, upkeep, and dismantling of temporary cofferdams/bundhs across the river with sandbags, sheet piling, or structural steel frames, along with continuous round-the-clock bailing out/dewatering of river water and slurry during foundation and well sinking. River Protection Work shall comprise heavy stone boulder pitching (minimum 300 mm to 450 mm thickness) laid over a non-woven geotextile filter fabric layer and galvanized iron (GI) wire crates/gabion mattresses around the entire perimeter of the intake well, scouring zones, bridge piers, abutments, and bank slopes to prevent erosion during high flood stages.
| 1 | JOB | 2,10,99,000 | ₹2,10,99,000 |
| 2.1 | 3. Intake Well Sub-Structure, Desludging & Superstructure (IS 456 / IS 3370):
Construction of RCC Intake Well-cum-Pump House having required sinking depth and internal diameter using cutting edge, curb, bottom plug, well steining, and grit/desilting chamber. Complete Desludging Arrangement comprising mechanical scrapping bucket/sludge scraper mechanism and dedicated sludge removal/desludging pipes with heavy-duty submersible sludge/slurry pumping provision to effectively clear deposited silt and sediment from the well bottom. Provision of RCC spiral/cantilever staircase extending up to the bottom level of the well.
Superstructure RCC framed Pump House having a minimum clear vertical height of 6.0 m above pump floor. Operating pump floor level must be kept minimum 1.50 m above the verified Highest Flood Level (HFL). Pump floor to have heavy-duty metallic/non-metallic floor hardener finish, circular inspection balcony (min. 1.0 m clear width), overhead electric travelling (EOT) / manual crane gantry girder of required load capacity, MS cat ladders with safety cages, steel rolling shutters, architectural anodized aluminium glazed windows/doors, and fresh air forced ventilation systems.
4. Water Inlet Ports, Flow Meter & Water Level Indicator:
Inlet Ports & Valves: Supply and installation of 400 mm nominal bore inlet pipes (4 runs x 15 m length) with SS/brass strainers and backwash/flushing piping arrangements. Supply and fixing of 3 sets of flanged sluice/knife-gate valves (PN 10 rating, 400 mm dia) of approved make (conforming to IS 14846) with extended stainless steel/forged steel operating spindles, headstocks, manual handwheels, and complete mountings.
Flow Meter: Supply, installation, testing, and commissioning of an Electromagnetic Flow Meter (full bore, flanged type, IP-68 sensor protection, bidirectional, with remote digital transmitter, LCD display, 4-20 mA output, and RS-485 communication port) on the main delivery manifold to measure instantaneous and totalized flow accurately.
Water Level Indicator: Supply and fixing of a non-contact Ultrasonic / Radar type Digital Water Level Indicator / Transmitter (IP-67/68 rating, intrinsically safe) with a digital display panel installed inside the pump house control room and calibrated staff gauges mounted on the well exterior to continuously monitor reservoir/river and well water levels.
| - | - | - | - |
| 2.2 | 5. RCC Connecting Footbridge (Span up to 70 m):
Construction of RCC Footbridge having a total length up to 70 m and 4.50 m overall width, resting on intermediate RCC piers/foundations and abutments. Bridge deck slab to feature a 3.50 m clear motorized/trolley pathway flanked on both sides by 0.50 m wide walkways paved with 80 mm thick M-30 precast interlocking zigzag paver blocks. The entire length to be protected with heavy-duty MS/GI safety handrailing of minimum 1.80 m overall height.
6. Sub-Station Building, Meter Room & Campus Civil Structures:
Power Sub-Station (PSS) Building,DG Yard & Transformer Yard: Construction of a dedicated RCC framed single-storey Sub-Station Building (as per standard DISCOM / UPCL / CEIG safety norms) to house HT/LT vacuum circuit breakers (VCB), indoor panels, battery chargers, and control panels. Includes built-in RCC cable trenches with MS chequered plate covers, anti-static / heavy-duty floor finish, rolling shutters, louvers for natural air exhaust, and external outdoor fenced RCC plinth transformer yard with pea-gravel/crushed stone filling and fire barrier walls (as per CEA regulations).
Electric Meter Room: Dedicated enclosed RCC framed/masonry Meter Room adjacent to the main campus entry point for DISCOM metering cubicles and check meters, complete with heavy-duty fire-rated steel door, concealed electrical conduits, safety glass viewing panel, and statutory earthing.
Security Guard Room: Single-storey RCC framed Guard Room (approx. 3.0 m x 3.5 m) with attached toilet, brick masonry walls, vitrified tile flooring, flush doors, aluminium windows, sanitary fittings, overhead water storage tank, and plumbing.
Boundary Wall & Entrance Gate: 2.1 m high boundary wall (PCC foundation, RCC columns, plinth/tie beams, 230 mm thick brickwork, plastering, coping, and concertina/barbed wire fencing on top) along the campus perimeter, including heavy-duty structural steel double-leaf entrance gate with wicket door.
Cement Concrete (CC) Road: 4.0 m wide internal CC approach road consisting of 150 mm granular sub-base (GSB), 100 mm PCC (1:4:8 / M-10) base course, and 200 mm thick vacuum dewatered M-30 grade concrete pavement with sealed expansion and contraction joints.
RCC Drainage Network: Roadside RCC covered storm water drains (minimum 300 mm x 450 mm clear size) with removable precast RCC perforated cover slabs.
Plantation & Landscaping: Horticultural development including lawn grass turfing, plantation of approved evergreen shade-bearing trees and ornamental flowering shrubs along the boundary wall and pathways.
| - | - | - | - |
| 2.3 | 7. Concrete Grades, Painting & Protection:
Plain concrete shall be minimum Grade M-15 and all structural RCC works (water-retaining well steining, slabs, piers, footbridge, PSS building, and road) shall be minimum Grade M-30 (mix design as per IS 10262, IS 456, and IS 3370) using corrosion-resistant Fe-500D TMT reinforcement steel.
Painting Specification: Interior walls of pump house, PSS building, meter room, and guard room to receive one coat primer and two coats acrylic distemper/washable paint; exterior exposed surfaces of pump house, intake well, PSS building, meter room, guard room, boundary wall, and bridge structures shall be finished with one coat approved primer and minimum three (3) coats of premium 100% acrylic weather-proof exterior silicone emulsion (Apex Ultima or approved equivalent). All exposed structural steel, gantry rails, ladders, gates, and handrails shall be painted with one coat red oxide zinc-chromate primer followed by two coats of anti-corrosive synthetic enamel/epoxy paint.
8. Electrification, Earthing & Safety Systems:
Complete concealed FRLS copper wiring for all campus buildings, main distribution boards, industrial LED high-bay luminaires, outdoor pole-mounted LED street/floodlights along the approach road and footbridge, complete earthing grid with maintenance-free chemical earthing electrodes, transformer/panel neutral earthing (as per IS 3043 / CEA norms), and advanced early streamer emission (ESE) lightning arresters.
All works shall be carried out strictly as per approved drawings, CPHEEO Manual on Water Supply and Treatment, CEA (Central Electricity Authority) Regulations, relevant Indian Standard (IS) codes, and to the complete satisfaction of the Engineer-in-Charge.
(Exclusion: Cost of Vertical Turbine (VT) pumps, main pump electric motors, HT/LT starter panels, transformers, HT switchgear, and PLC/SCADA wireless telemetry instrumentation are excluded from this item and payable under separate electro-mechanical BOQ schedules). | - | - | - | - |
| 3Construction of Water Treatment Plant Survey, Investigation, Planning, Design ,Vetting of design from IIT BHU, Construction and Commissioning of WTP capacity 6 MLD with CWR as per required capacity. For construction of WTP,400 SQM plinth area two storey furnished Admin Building with solar sysem arrengments , Command Control Room & required furnitures,required1.8 mtr height boundary wall with barbed wire with 3.6 mtr wide gate, 200 SQM plinth area 2 storey staff quater,4m width CC approach road for all structure (internal & external ) with Rcc coverd storm water drain, 100 sqm area Sub station room, meter room(as per UPPCL) DG yard, transformer yard and fire fighting arrangements, first aid arrangements Circular Cascading Aerator,digital flow meter ( inlet & outlet) ,Inlet chamber,overflow chamber, alum dosing, pre-sedimentation Tank, Rapid Mix, Vertical Flow Clarifloculator, Rapid Gravity Filter with Back Wash Arrangement,reuse arrengments, Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area & Appurtenant Works. Automated through PLC with outputs to SCADA, 1.5 meter wide walkway in between WTP components with railing, 10 sqm area Guard Room, 50 sqm area Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit, greeneries, plantation etc. Raw water to be treated and filtered.,reused, Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Employer/IS code. Collapsible MS steel doors and aluminium windows to be provided including of One-coat Priming, internal two coat Distamper painting, external painting with apex ultima,food grade epoxy/equivalent paint/Weither Paint, all steel work must be painted with red oxide paint and three coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data) Including water testing kits, lab building and essential lab as per cpheeo manuals equipments,4 nos 2 ton AC 5 star latest model, 4 nos computer (43 inch display, i7processor 1 tb storage)with UPS, 3 nos Network MFP printers Including supply of all materials, labour T&P etc. required for proper completion of works as per direction of the Engineer. All units designed & constructed for 6.6 MLD ,10% overload. | |||||
| 4 | Civil Work | 1 | JOB | 2,80,65,000 | ₹2,80,65,000 |
| 5 | Supply of all materials, labour, tools and plants for Renovattion /Augumentation of existing water Treatment Plant, comprising of Presedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator / Rapid Gravity Filter Back Wash arrangment, disinfection unit,Recycle arrengments, Gaseous chlorinator & Appurtenant works of 1.95 MLD Capacity. including all damage plaster with painting of three-coat whitewashing, internal two coat acrylic painting , external painting with apex ultima/equivalent paint,replace/ repair of DOOR & WINDOW/VENTILATION all steelwork / wooden work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data) including all civil and E&M work etc. complete as per direction of engineer incharge.not mention in above work can be done as per instructed on report IIT BHU VARANASI (work exceution as per inspection of IIT BHU VARANASI) OWN VETTING/ INSPECTION COST BORNE BY CONTRACTOR. | 1 | JOB | 54,84,000 | ₹54,84,000 |
| 6Rising Main :- Supply of following sizes (DI K-9) pipes for rising main system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as MJ joints, tee ,bends, all required mild steel fabrication works (if MS fabrication used, its proper protection treatment against corossion must be done) and all DI specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS‐1239 /2000 and IS 8329/2000 or their latest amendment & CPHEEO latest amendments including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & iniclusive of all Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. with loading, unloading and Carting up to store,HYDRAULIC TESTING AS PER CPHEEO MANUALS latest amendments also including specials for these pipes all complete as per instructions of Engineer ‐in ‐ charge. | |||||
| 7 | 350 mm dia | 600 | mtr. | 5,059.82 | ₹30,35,892 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BIDPIPARI765F.pdf
Tender Documents • 11.11 MB
BOQ_2286585.xls
BOQ • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .