Loading…
Loading…
Tender Value
₹4.2 Cr
EMD Value
₹3.6 L
Closing Date
10 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. NOTE: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered atleast 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Any Relay Interlocking (RI) or Electronic Interlocking (EI) or Color Light Signaling using Lever Frame (CLS) or Automatic Block Signalling (ABS) or Intermediate Block Signalling (IBS) work involving Indoor and Outdoor work (Cable laying & termination). (also refer tender document attached)
10 conditions · 4 needing a document upload
As per tender document attached.
As per tender document attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Design, supply, installation, testing and commissioning along with indoor and outdoor works of Electronic interlocking, Alteration in electronic interlocking, MSDAC works, BPAC works, IPS works etc. in connection with the work of "Gumandev. BG: Development of loading lines in new goods shed" of Vadodara Division.
SandT_BRC_25-26_15_SIG~WR
SandT_BRC_25-26_15_SIG
Open
Works - General
11 Months
Vadodara, Gujarat
₹0
₹3.6 L
10 Feb 2026
19 Jan 2026
27 Jan 2026
293 items across 6 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,49,63,713.13 | ||
| — | 112.00 | Per Functional Vital Bit | — | ||
| Design, manufacture and supply of Hot Standby Architecture Electronic Interlocking (EI) system i.e. Distributed or Centralized as per requirement of zonal railway, complete as per RDSO specification and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements, Industrial grade maintenance Terminals (32'' LED or higher size with UPS minimum 1 hr back up with Printer) and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 3. Non vital I/O- can be used only for accessories where SIL-4 condition required. 4. Station less than 200 routes- RDSO/SPN/192/2019 Ver.2.0 with latest amendment. 5.Station greater than 200 routes - RDSO/SPN/203/2011 Ver1 or latest. Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC-DC Convertors, Moxa switch, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. | — | — | — | 93,22,677.28 | |
| — | 1.00 | — | — | ||
| Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for the EI system should be supplied for stations as per schedule item 1 above. This includes tools required for EI maintenance sorts of crimping, insertion, removal. General purpose tools like screwdrivers, spanners, PCB extractor, temp. Controlled soldering iron, wire cutter, nose pliers, etc. Measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at the site). Each set comprises the following: - 1. Crimping tool for all types of special cable assembly used in EI system. 2. Insertion tool for all types of special cable assembly used in EI system. 3 .Removal tool for all types of special cable assembly used in EI system. 4. Digital multimeter (Fluke 111 or better) 5. Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485 mm depth (Godrej Make/Jalaram) of good quality to store tools, spare cards and documents.6. Clamp Earth Tester. 7. Clamp Current Meter. | — | — | — | 1,30,201.33 | |
| — | 1.00 | — | — | ||
| Earthing of EI equipment, relay racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre-commissioning check list of EI system. | — | — | — | 1,33,269.46 | |
| — | 1.00 | — | — | ||
| Supply of Completion SIP in Original tracing along with Auto CAD copy in Pen Drive and Six set copies after approval. Upto four line station | — | — | — | 818 | |
| — | 1.00 | — | — | ||
| Supply of completions ST/LT/TOC in original tracing along with AutoCAD copies in Pen Drive and six set copies after approval. Upto four line station | — | — | — | 790 | |
| — | 1.00 | — | — | ||
| Supply of Circuit Diagrams consisting wiring/Logic diagram, contact analysis, fuse detail, Input/output bit chart, VDU diagram, Interface in AutoCAD in Pen Drive and Six set of Copies after approval Upto four line station | — | — | — | 29,615 | |
| — | 1.00 | — | — | ||
| Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval. Upto four line station | — | — | — | 2,961 | |
| — | 1.00 | — | — | ||
| Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval. | — | — | — | 1,580 | |
| — | 1.00 | — | — | ||
| Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards. Station | — | — | — | 63,698 | |
| — | 1.00 | — | — | ||
| Design and supply SWR Diagram on standard tracing paper of 95grams for each station. Corrected version of SWR plans after checked & approved by Rly's 25 Ferro copies will be supply for each of the plans. For stations having up to 4 lines | — | — | — | 24,321 | |
| — | 1.00 | — | — | ||
| Design and supply SWR Diagram on standard tracing paper of 95grams for each station. Corrected version of SWR plans after checked & approved by Rly's 25 Ferro copies will be supply for each of the plans. For stations having more than 4 lines | — | — | — | 53,506 | |
| — | 1.00 | — | — | ||
| Data logger system for Railway S&T installation As per spec. IRS: S-99 2006 (Amdt-3) or latest. Central Monitoring Unit (Hardware Configuration as per Annexure) with UPS minimum 06 hrs battery backup and required Software tools. This also includes the supply of one no composite computer & printer table (Godrej workstation table) for keeping the Processor module and one no Godrej make operator chair model PCH7001. 1024 digital and 32 analog inputs. | — | — | — | 6,30,312.5 | |
| — | 2.00 | — | — | ||
| Failure Analysis & Fault Diagnostic software for data logger of 1024 digital inputs /4096 digital inputs. | — | — | — | 1,04,902.8 | |
| — | 2.00 | — | — | ||
| Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R. | — | — | — | 8,878.56 | |
| — | 2.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 57,155.44 | |
| — | 10.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 2,98,239.1 | |
| — | 2.00 | — | — | ||
| Supply of Multi lamp numeric indicator (LED Single/double digit) as per engineer in charge. | — | — | — | 1,25,325.08 | |
| — | 2.00 | — | — | ||
| Junction route indicator unit 1way as per Drg. No. RDSO SA 23401 suitable for LED Signal Lighting Unit & as IRS: S-66/84 amndt-1or latest. (Supply of LED Unit is not covered in this item). | — | — | — | 42,101.04 | |
| — | 2.00 | — | — | ||
| Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv.) Alt1 suitable to LED Signal Lighting Unit. | — | — | — | 5,338.86 | |
| — | 2.00 | — | — | ||
| Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). | — | — | — | 9,060.14 | |
| — | 12.00 | — | — | ||
| Supply Color Light Signal Accessories. 1. CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M With latest assembly). 2. Pinnacle. 3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. 4. Signal Front Staging Complete Assembly for CLS Unit. 5. Signal back staging as per extent WR Practice. | — | — | — | 39,015.96 | |
| — | 12.00 | — | — | ||
| Supply Color Light Signal Accessories. Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186. | — | — | — | 7,387.08 | |
| — | 12.00 | — | — | ||
| Provision of DC track Circuit Components includes 1 Charger, 2 Choke Coils, 3 LMLA Batteries, 1 nos Track Feed resistance. | — | — | — | 1,84,826.64 | |
| — | 1.00 | — | — | ||
| Supply of Tools Kit for Digital Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec. No. RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012,Ver.3 or latest respectively). The tool kit shall be minimum equipped with the following equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 No. (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 No. (vi) Marking Jig - 1 No. (vii) Adapter card - 1 No. (viii) Extended wired socket to interface with diag No. stic plug - 1 No. (viii) Selector switch on panel base - 1 No. (ix) DAC EC card puller etc. | — | — | — | 1,44,043.4 | |
| — | 34.00 | — | — | ||
| DC neutral line relay QNA1K (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest | — | — | — | 1,99,219.94 | |
| — | 12.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78. | — | — | — | 65,056.8 | |
| — | 12.00 | — | — | ||
| Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | — | — | — | 88,724.16 | |
| — | 12.00 | — | — | ||
| Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F- 1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | — | — | — | 58,546.8 | |
| — | 4.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 38,975.88 | |
| — | 1.00 | — | — | ||
| Supply of Smart Cabinet/Rack for Housing of Various S&T equipments like KLCR, Reset Box, IPS Indication Panel, CA VA Unit for FACS, SP AU for Point Reversal, Crank Handle, Quad Cable Earth Sensing Unit along with Fixing of KLCR (KLCR will be provided by Railway) as per instruction of Site Engineer, Make RITTAL, SANTEL, VERO , PRESIDENT, APC Schneider or similar reputed make | — | — | — | 58,030.77 | |
| — | 8.00 | — | — | ||
| Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | — | — | — | 1,92,064.96 | |
| — | 1.00 | — | — | ||
| Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance. | — | — | — | 1,51,574.89 | |
| — | 150.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 7,648.5 | |
| — | 100.00 | — | — | ||
| Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS: S-80/92. | — | — | — | 3,444 | |
| — | 100.00 | — | — | ||
| Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92. | — | — | — | 12,941 | |
| — | 100.00 | — | — | ||
| HRC fuses block complete with 2A fuse link as per IS 9224/79. | — | — | — | 7,056 | |
| — | 100.00 | — | — | ||
| D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge. | — | — | — | 3,193 | |
| — | 100.00 | — | — | ||
| D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS: S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. | — | — | — | 3,486 | |
| — | 2.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 1,03,907.56 | |
| — | 8.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 2,37,949.04 | |
| — | 1200.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 70,236 | |
| — | 120.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 1,328.4 | |
| — | 240.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 2,606.4 | |
| — | 25.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 2,847 | |
| — | 1.00 | — | — | ||
| Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments. | — | — | — | 3,354.08 | |
| — | 8.00 | — | — | ||
| Fire Extinguisher CO2 type (capacity 5 kg). | — | — | — | 54,512.4 | |
| — | 12.00 | — | — | ||
| SMC Booklets of each station register for SMC register. (1 Register to be read as 1 Number). | — | — | — | 1,441.44 | |
| — | 34.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. | — | — | — | 3,53,704.72 | |
| — | 1800.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 1,35,000 | |
| — | 12.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 6,23,976.72 | |
| — | 10.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 5,98,559.8 | |
| — | 16.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | — | — | — | 86,218.72 | |
| — | 1.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 5,548.54 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. ( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 33,366.21 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 68,031.77 | |
| — | 0.50 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 66,252.56 | |
| — | 60.00 | — | — | ||
| — | — | — | 70,216.8 | ||
| — | 100.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick). | — | — | — | 12,163 | |
| — | 24.00 | — | — | ||
| Provision of Field accessories of DC Track Circuits Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks. | — | — | — | 26,895.6 | |
| — | — | — | 1,78,52,069.44 | ||
| — | 2.00 | — | — | ||
| Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge. Approximate Screen size 55 inch | — | — | — | 1,73,274 | |
| — | 2.00 | — | — | ||
| Supply and Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input : 110 v DC Output : 24 V DC/ 10A,Qty -10No.s 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. | — | — | — | 5,45,724 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GumandevTenderNew19-01-2026.pdf
ATTACHMENT
GumandeveAppendix19-01-2026.pdf
ATTACHMENT
IRSEM-AppendixII_compressed.pdf
ATTACHMENT
TentativeSIp.pdf
ATTACHMENT
RevisedTANonEarthingBondingetcSnTInstallation.pdf
ATTACHMENT
2025-07-29-TAN3012VER4_250804_205106.pdf
ATTACHMENT
TSAACHECKLISTVER2.pdf
ATTACHMENT
CONSIGNEEINSPECTIONGUIDELINES.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .