Kochi Municipal Corporation Park Avenue Ernakulam , Kochi 682011
Kochi municipal Corporation CCPC2/MOE/28206/22 HVAC works-Air conditioning and allied works(Electrical) to main office building,Kochi municipal corporation
2022_LSGD_543752_1
Kochi municipal Corporation CCPC2/MOE/28206/22
Open Tender
Electrical Works
Item Rate
240 days
Ernakulam
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,900
Yes
₹50,000
Yes
20 Mar 2025
27 Dec 2022
13 Jan 2023
27 Dec 2022
11 Jan 2023
27 Dec 2022
Amount
Air Conditioning
OD90691/2022-2023:Supply, installation, testing and commissioning of 360 degree Round cassette type VRF IDU of following specifications with wireless remote: Unit shall be factory assembled, wired, piped and run tested. Unit shall have perfect round uniform airflow without blind spots. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. 4.0 Tr Round Cassette
OD90695/2022-2023:Supply, installation, testing and commissioning of 4 Way cassette type VRF IDU of following specifications with wireless remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall have factory installed motorized louver to provide flow of air in up / down direction for uniform airflow. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. Unit shall have a single, direct driven, turbo fan made of a Polypropylene (PP) resin or a high strength Acrylonitrile Butadiene Styrene (ABS) HT 700 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. 3.0 TR 4 Way Cassette
OD90696/2022-2023:Supply, installation, testing and commissioning of 4 Way cassette type VRF IDU of following specifications with wireless remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall have factory installed motorized louver to provide flow of air in up / down direction for uniform airflow. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. Unit shall have a single, direct driven, turbo fan made of a Polypropylene (PP) resin or a high strength Acrylonitrile Butadiene Styrene (ABS) HT 700 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. 2.5 TR 4 Way Cassette
OD90697/2022-2023:Supply, installation, testing and commissioning of 4 Way cassette type VRF IDU of following specifications with wireless remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall have factory installed motorized louver to provide flow of air in up / down direction for uniform airflow. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. Unit shall have a single, direct driven, turbo fan made of a Polypropylene (PP) resin or a high strength Acrylonitrile Butadiene Styrene (ABS) HT 700 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. 2.0 TR 4 Way Cassette
OD90698/2022-2023:Supply, installation, testing and commissioning of 4 Way cassette type VRF IDU of following specifications with wireless remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall have factory installed motorized louver to provide flow of air in up / down direction for uniform airflow. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. Unit shall have a single, direct driven, turbo fan made of a Polypropylene (PP) resin or a high strength Acrylonitrile Butadiene Styrene (ABS) HT 700 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. Unit shall be factory assembled, wired, piped and run tested. Unit shall have factory installed motorized louver to provide flow of air in up / down direction for uniform airflow. Unit shall have a built-in control panel to communicate with other indoor units and to the outdoor unit. Unit shall have a single, direct driven, turbo fan made of a Polypropylene (PP) resin or a high strength Acrylonitrile Butadiene Styrene (ABS) HT 700 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings.
OD91480/2022-2023:Supply, installation, testing and commissioning of High Static Ducted VRF IDU of following specifications with wired remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall be designed to be installed for indoor application. Unit shall be designed to mount fully concealed above the finished ceiling. Unit shall have one or two direct drive sirocco fan(s) made of a high strength Acrylonitrile Butadiene Styrene (ABS) GP-2200 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. The unit shall be provided with inbuilt Drain pump. 8.0 TR capacity, ceiling suspended, High Static
OD91481/2022-2023:Supply, installation, testing and commissioning of High Static Ducted VRF IDU of following specifications with wired remote : Unit shall be factory assembled, wired, piped and run tested. Unit shall be designed to be installed for indoor application. Unit shall be designed to mount fully concealed above the finished ceiling. Unit shall have one or two direct drive sirocco fan(s) made of a high strength Acrylonitrile Butadiene Styrene (ABS) GP-2200 resin. The fan impeller shall be statically and dynamically balanced. The fan motor shall be Brush Less Direct Current (BLDC) type with permanently lubricated and sealed ball bearings. The unit shall be provided with inbuilt Drain pump. 4.0 TR capacity, ceiling suspended, High Static
OD91482/2022-2023:Supply, installation, testing & commissioning of double skin thermal break floorstanding AHU with 40 mm sandwitched PUF insulation of density not less than 36 Kg/m3, inner sheets of panels shall be made of 0.6 mm thick and outer sheet shall be of 0.6 mm thick GSS with pre plasticised finish, extruded aluminium frame work. Components include , 6 Row deep DX coil of copper tube & Aluminum fins, insulated drain pan, DIDW Fans , TEFC squirrel cage induction motor of IE-3 rating including mounting and fixing arrangement, anti vibration isolators. Canvas connection on fan inlet shall be of fire retardant type. AHU mounted Low leakage Aluminum damper at discharge to be provided. All internal blank offs, coil supports and 100mm GI baseframe shall be powder coated for durability and clean internals.: Approved Makes Zeco, VTS, Edgetech 8000 CFM, 20 TR ,40 mm ESP
OD91484/2022-2023:Supply, installation, testing & commissioning of double skin thermal break floorstanding AHU with 40 mm sandwitched PUF insulation of density not less than 36 Kg/m3, inner sheets of panels shall be made of 0.6 mm thick and outer sheet shall be of 0.6 mm thick GSS with pre plasticised finish, extruded aluminium frame work. Components include , 6 Row deep DX coil of copper tube & Aluminum fins, insulated drain pan, DIDW Fans , TEFC squirrel cage induction motor of IE-3 rating including mounting and fixing arrangement, anti vibration isolators. Canvas connection on fan inlet shall be of fire retardant type. AHU mounted Low leakage Aluminum damper at discharge to be provided. All internal blank offs, coil supports and 100mm GI baseframe shall be powder coated for durability and clean internals.: Approved Makes Zeco, VTS, Edgetech AHU kit for Connecting VRF ODU
OD91485/2022-2023: Supply Installtion testing and commissioinig of AHU starter panel with DOL , suitable relay protection to interlock with termostat and AHU
OD91486/2022-2023:Supply, installing testing and commissioning of copper distribution Y- Joints with insulation
OD91488/2022-2023:Supply, installation, testing and commissioning of interconnecting insulated copper tubing, for refrigerant liquid and suction lines (Pair) between the Outdoor and Indoor Units complete, including fittings like elbows, reducers etc. and suitable wall / ceiling clamps as required for the complete installation and proper functioning of the VRV/VRF system. The suction lines shall be insulated with 19 mm thick and discharge lines shall be insulated with 13mm closed cell nitrile rubber flexible hose insulation.
OD91489/2022-2023:Supply, installation, testing and commissioning, Transmission/Communication cabling, of 2 core 1.5 Sqmm non polar shelied cable for interconnecting the Indoor and Outdoor Units of all the VRV/VRF Units for proper performance , Communication cable must be routed throgh PVC pipe.
OD91492/2022-2023:Supply,testing and commissioning of condensate drain with necessary clamps, supports,hangers and fitting such as bend, tees,reducers etc. duly insulated with 9mm thick chemicallycross-linked closedcell ntrile rubber insulation as per the drawing and relavent standards 25 mm
OD91493/2022-2023:Supply,testing and commissioning of condensate drain with necessary clamps, supports,hangers and fitting such as bend, tees,reducers etc. duly insulated with 9mm thick chemicallycross-linked closedcell ntrile rubber insulation as per the drawing and relavent standards 32 mm.
OD91494/2022-2023:Supply,installation,testing and balancing of factory fabricated Round GSS ducting of following thickness including necessary supports ,hangers ,nutbolts, etc.complete as per SMACNA/IS655 standards . 24 guage.
OD91495/2022-2023:Supply,installation,testing and balancing of factory fabricated Round GSS ducting of following thickness including necessary supports ,hangers ,nutbolts, etc.complete as per SMACNA/IS655 standards .22 Guage
OD91496/2022-2023:Supply,installation,testing and balancing of factory fabricated Rectangular GSS ducting of following thickness including necessary supports ,hangers ,nutbolts, etc.complete as per SMACNA/IS655 standards . 24 guage
OD91497/2022-2023:Supply,installation,testing and balancing of factory fabricated Rectangular GSS ducting of following thickness including necessary supports ,hangers ,nutbolts, etc.complete as per SMACNA/IS655 standards . 22 guage
OD91498/2022-2023:Supply installation and testing of Thermal insulation of ducting using closed cell nitrile Rubber insulation with recommended ashesives and sealed with black adhasive tape and density of material shall be 40-60 kg/cubm 13mm thick nitrile Rubber
OD91500/2022-2023:Supply,installationand testing of acoustic lining with10mm thick open cell nitrile foam on the inner side of ducting including providing,fixing and finishing the same as per specifications for ducts as required density of material shall be 140-180 kg/cubm 10 mm thick nitrile Rubber
OD91501/2022-2023:Jet Diffuser (Eye Ball ) - 350mm Dia with mounting flanges, spigot, collar damper for the diffuser as per dwg.
OD91502/2022-2023:Supply, Installation, Testing and Balancing of Powder coated extruded aluminium construction LINEAR GRILLES with removable core as per approved drawings and specifications.
OD91503/2022-2023:Supply, installation & testing of GI Volume Control dampers VCD shall be opposed blade type. VCD shall have a locking device mounted outside the duct to hold the VCD in a fixed position without vibration. Fully open and fully closed position shall be marked for easier operation of VCD.
OD91504/2022-2023:Supply, installation & testing of Fire dampers in supply air duct. Fire dampers shall be spring actuated on melting of fusible link having a melting point of 67±3°C & complete as required.
PONNU HYLINE
Bidder Name
PIONEER COOLTECH
PONNU HYLINE
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .