Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Non Responsive |
Tender Value
Refer Docs
EMD Value
₹10.1 L
Closing Date
27 Jun 2025, 12:30 pmClosed
Managing Director
3rd Floor UPSTDC Ltd Gmoti Nagar Lucknow
Tourism development work of Trivati Nath temple under Nath corridor in Bareilly district.
2025_STDCL_1050337_2
4505/Pari-5/Nivida Suchna/2025-26
Open Tender
Civil Works
540 days
Bareilly
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,714
UPSTDC Ltd
₹10.1 L
8 Jul 2025
21 Jun 2025
27 Jun 2025
21 Jun 2025
27 Jun 2025
21 Jun 2025
Civil Works Excavation in foundations in ordinary soil Loame, clay or sand including lift upto 1.5 m. lead upto 30 m.inciuding filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the Engineer i/c upto a distance of 30 m from the foundation trenches. (excluding Royalty) D.S.R. Item No. 2.8.1
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. D.S.R. Item No. 2.25(a)
Sand filling in plinth incl supply of necessary qty of sand from a distance not exceeding 5 km fro the site of work & incl watering, dressing etc. Rate includes costof all materials, labour and T&P etc. required for proper completion of work (incl royalty) DSR Item No. 2.27
Providing & laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.8
C.C. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) D.S.R. Item No. 4.1.3
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto Plinth level D.S.R. Item No. 5.33.1.1
All works above plinth level upto floor V level D.S.R. Item No. 5.33.2.1
S&F Mild steel or iron in plain work such as reinforced concrete and reinf. b/work (when not included in overall rate) wrougt to required shape as necessary Including bending for proper completion of work and incl supply of all steel and wastage and overlapping and hook D.S.R. Item No. 5.22.1
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R. Item No. 4.10
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete DSR 5.9.1
Columns, Pillars, Piers, Abutments, Posts and Struts D.S.R. Item No. 5.9.6
Lintels, beams, plinth beams, girders, bressumers and cantilevers D.S.R. Item No. 5.9.5
Suspended floors, roofs, landings, balconies and access platform D.S.R. Item No. 5.9.3
Centering and shuttering including strutting, propping etc. and removal of form for Cornices and mouldings D.S.R. Item No. 5.9.17
Brick work in foundation 1st class b/work in 1:4cement and couarse sand mortar in fdn and plinth incl. supply of all materials , labour and t& P required for proper completion of the work D.S.R. Item No. 6.2.1
Brick work in SUPER STRUCTURE in 23 cm thk wall with 1:4 cement and coarse sand incl. all materials labour annd t&p etc. for proper completion of work. D.S.R. Item No. 6.4.1
Class 150 Brick work in 1:3 cement and Coarse Sand of 1.25 finentss modulusbut in Parapet including necessary cutting and moulding of brick work as required and also including honey combed brick work in thickness of wall more than 12 cms. D.S.R. Item No. 6.13.1
12 mm thk plaster (1:4) with cement & Coarse Sand D.S.R. Item No. 13.4.1
15mm cement plaster on rough side of single or half brick wall finished with 1:4 (1 cement : 4 coarse sand) D.S.R. Item No. 13.5.1
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick D.S.R. Item No. 11.26.1
Supplying and fixing rolling shutters of approved make of 80x125mm (3x3½") guage cold rolled M.S. laths inter locked throuhout their entire length and joined together at the end by end locks and nmounted on specially designed pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operations complete but excluding the cost of top cover and spring. DSR 10.6.1
Providing and fixing ball bearing for rolling shutters SOR-523 D.S.R. 10.7
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR Item No. 13.80
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (make:Asian/Berger/Dulux) D.S.R. Item No. 13.48.1
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture D.S.R. Item No. 13.62.1
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. D.S.R. 22.7.1
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase D.S.R No 12.21.1
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. D.S.R.No.12.22.
Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). PWD SOR Item No. 13.46.1
Stone Cladding Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone D.S.R. Item No. 8.20.2
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). D.S.R. Item No. 8.21
Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : White sand stone D.S.R. Item No. 7.12.2.2
Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : Circular or polygonal pillars D.S.R. 7.21.2
Extra for stone work ashlar sunk or moulded in cornices D.S.R. 7.22
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. DSR 8.22
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 160 mm DSR Item No. 10.27.5
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 7.33.2 White sand stone D.S.R. Item No. 7.33.2
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) D.S.R. Item No. 10.15.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws D.S.R. Item No. 9.21.1
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only D.S.R. Item No. 9.22.1
6 mm thick clear heat strengthened glass 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). D.S.R. 9.7.7.2
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Make : Kajaria/ Simpolo/Johnson) DSR 8.31
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. D.S.R. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels plain white marble/ udaipiur green marble / zebra balck marble area of slab over 0.50 sqm Ground Floor DSR Item No. 8.2.2.1
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. DSR 2021 Item no. 8.5
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work DSR 2021 Item no. 8.3.2
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. DSR 9.76
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. DSR 9.77
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil D.S.R. Item No. 2.28.1
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: D.S.R. Item No. 10.2
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing balcony railing & staircase railing including applying a priming coat of approved steel primer. M.S. tube. D.S.R. Item No. 10.26
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. 1.00 mm thick with zinc coating not less than 275 gm/m² D.S.R. Item No. 12.1.1
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete. With residual type petroleum bitumen of grade VG - 10 D.S.R. Item No. 12.15.1
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Make : Simpolo/Johnson/Kajariya 11.41A.1.3 Size of Tile 600 x 1200 mm D.S.R. Item No. 11.41A.1.3
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² D.S.R. Item No. 12.7.1
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). D.S.R. Item No. 9.1.2
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters D.S.R. Item No. 9.5.1.1
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) D.S.R. Item No. 13.116
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). D.S.R. Item No. 9.147A1.3
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 D.S.R. Item No. 16.78
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. D.S.R. Item No. 16.91.2
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). D.S.R. Item No. 16.69
Internal Electrical Works Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated coppe r conductor single core cable etc as required. Group C D.S.R. Item No. 1.10.3 make:Schneider/RR Kabel/Northwest
Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. D.S.R. Item No. 1.14.1 2X1.5 sqmm + 1x1.5 sqmm earth wire make:Schneider/RR Kabel/Northwest
2X2.5 sqmm + 1x 2.5 sqmm earth wire make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.14.2
2X4.0 sqmm + 1x 4.0 sqmm earth wire make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.14.3
2X6.0 sqmm + 1x 6.0 sqmm earth wire make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.14.4
Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.19
Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.21
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. make:Schneider/RR Kabel/Northwest TV antenna socket outlet D.S.R. Item No. 1.24.7
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. make:Schneider/RR Kabel/Northwest D.S.R. Item No. 1.26
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm ) D.S.R. Item No. 1.27 make:Schneider/RR Kabel/Northwest
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. D.S.R. Item No. 1.32 make:Schneider/RR Kabel/Northwest
Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. make:Schneider/RR Kabel/Northwest
Supplying and fixing brass batten/angle holder including connectionetc. as required. D.S.R. Item No. 1.34 make:Schneider/RR Kabel/Northwest
Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. D.S.R. Item No. 1.35 make:Schneider/RR Kabel/Northwest/Bajaj
Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. D.S.R. Item No. 1.41 make:Schneider/RR Kabel/Northwest/Bajaj
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. D.S.R. Item No. 1.45 make:Schneider/RR Kabel/Northwest/Bajaj
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. D.S.R. Item No. 1.49
Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep. D.S.R. Item No. 1.50
Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. D.S.R. Item No. 1.51
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. D.S.R. Item No. 1.57
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. D.S.R. Item No. 14.15
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. make: Bajaj/Havells/Crompton D.S.R. Item No. 19.1
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). D.S.R. Item No. 2.3.3 make:Schneider/RR Kabel/Northwest 12 way, Double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole D.S.R. Item No. 2.10.1 Make:Schneider/RR Kabel/Northwest
Double Pole D.S.R. Item No. 2.10.2 Make:Schneider/RR Kabel/Northwest
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. D.S.R. Item No. 2.11 Make:Schneider/RR Kabel/Northwest
Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. D.S.R. Item No. 5.40 Make: As approved in U.P.P.W.D & C.P.R.I.
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Make: As approved in U.P.P.W.D & C.P.R.I. D.S.R. Item No.5.9 Make:Schneider/RR Kabel/Northwest
Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. Make: As approved in U.P.P.W.D & C.P.R.I. D.S.R. Item No. 5.7 Make:Schneider/RR Kabel/Northwest
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. D.S.R. Item No. 7.1.1 Upto 35 sq. mm Make: Finolex/R.R. Kabel
Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm) D.S.R. Item No. 9.1 Make: Finolex/RR Kabel
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12) 14.13.1 Make Finolex
Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. 16 sqmm 3.5 core Make - Finolex/RR Kabel
Supply and erection of 1X10 W mirror light complete in all respects Make : Philips/Bajaj
Supply & fixing of 7/9 W LED BULB complete in all respect.
Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. Make : Philips/Bajaj
Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Make : Philips/Bajaj
Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as 300mm sweep. required.-Make : Philips/Bajaj
Providing & fixing Wall Bracket Light FAÇADE -6434-3w Make Bajaj, Philips
Providing & Fixing Wall Focus Light FAÇADE 5100 7 Watt Make Bajaj, Philips
Plumbing & Sanitary Works Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Make: Jaquar D.S.R Item No. 17.1.1
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid Make: Jaquar D.S.R. Item NO. 17.2.1
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. D.S.R. Item No. 17.7.4 Make: Jaquar
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Make : Finolex/Astral D.S.R. Item No. 17.28.1 32mm dia
b) 40mm dia D.S.R. Item No. 17.28.1
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. D.S.R. Item No. 17.31
Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. Make: Jaquar D.S.R. Item No. 17.71
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter D.S.R. Item No. 12.41.2 Make : Finolex/Astral
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm Make : Finolex/Astral
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Make : Finolex/Astral
Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & makinggood the walls etc. Make : Finolex/Astral 25mm dia nominal bore D.S.R. Item No. 18.10.3
Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore. D.S.R. Item No.18.40
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Make : Finolex/Astral D.S.R. Item No. 18.7.2 20mm dia nominal outer dia pipes
25mm dia nominal outer dia pipes Make : Finolex/Astral D.S.R. Item No. 18.7.3
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes Make : Finolex/Astral D.S.R. 18.8.1
20mm dia nominal outer dia pipes Make : Finolex/Astral D.S.R. 18.8.2
25mm dia nominal outer dia pipes Make : Finolex/Astral D.S.R. 18.8.3
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore Make : Finolex/Astral D.S.R. 18.21.2.1
Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore D.S.R. Item No. 18.49.1Make : Jaquar
Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore Make : Jaquar D.S.R. Item No. 18.53
Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore D.S.R. Item No. 18.17.1 Make : Jaquar
20 mm dia nominal bore D.S.R. Item No. 18.17.1A Make : Jaquar
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore D.S.R. Item No. 18.18.3 Make : Jaquar
Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. D.S.R. Item No. 18.48 Make : Finolex/Astral
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. D.S.R. Item No. 2.10.1.2
Providing & Fixing PVC Pipe Make : Finolex/Astral 100mm diameter
Providing & Fixing PVC Pipe Make : Finolex/Astral 150mm diameter
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe D.S.R. Item No. 19.2.1
150mm diameter S.W. Pipe D.S.R. Item No. 19.2.2
Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 D.S.R. Item No. 19.4.2.2
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line D.S.R. Item No. 19.7.1.1
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar D.S.R. Item 19.15.1
FIRE FIGHTING WORKS. SUB HEAD - I (WET RISER SYSTEM - EQUIPMENTS) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head D.S.R. Item No. 4.2
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 1.2 Meter high and 250 mm dia P.S.
Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.P.S.
SUB HEAD - II - (PIPING, VALVES AND ACCESSORIES) SLTC of M.S. pipe on surface Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.7
80 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.6
DSR & AOR Wet Riser & Sprinkler 2019_7.5 65 mm dia
50 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.4
40 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.3
32 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.2
25 mm dia DSR & AOR Wet Riser & Sprinkler 2019_7.1
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_11.5
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 100 mm dia DSR & AOR Wet Riser & Sprinkler 2019_14.5
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. DSR & AOR Wet Riser & Sprinkler 2019_13
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926. MR
SUB HEAD - III - (HYDRANTS SYSTEM) Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel DSR & AOR Wet Riser & Sprinkler 2019_9.2
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) DSR & AOR Wet Riser & Sprinkler 2019_16.2
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) DSR & AOR Wet Riser & Sprinkler 2019_18.2
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30M DSR & AOR Wet Riser & Sprinkler 2019_17.1
SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch. Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - a) Gunmetal single headed Hydrant valve - 1 No. b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. c) Short branch - 1 No. d) First Aid hose Reel - 1 No. e) Fire Extinguisher - 2 Nos. f) Fireman's Axe - 1 No. g) Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade. MR
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe DSR & AOR Wet Riser & Sprinkler 2019_19.1
SUB HEAD - IV - (FIRE EXTINGUISHERS) Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 4.5kg capacity cylinder. MR
Providing and fixing fire extinguisher of ISI marked (IS:15638) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications. MR
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. DSR E&M 2018_17.1.2
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. DSR E&M 2018_17.1.3
Supplying, installation, testing & commissioning fire alarm ounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. DSR E&M 2018_17.1.7
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required. DSR E&M 2018_17.5.1
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 21.1 Pendent Sprinkler
SUB-HEAD-II (HT CABLES ) Supply and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 300 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. D.S.R. 2022 Electrical Item No. 10.1.4
Supply and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 300 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required. D.S.R. 2022 Electrical Item No. 10.2.4
SUBHEAD III-EARTHING AND LOOP EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. D.S.R. 2022 Electrical Item No. 5.2
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. D.S.R. 2022 Electrical Item No. 5.4
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required. D.S.R. 2022 Electrical Item No. 5.6
Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects. D.S.R. 2022 Electrical Item No. 6.14
Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects. P.W.D.SOR Electrical 2018 ITEM No. 718
Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respects. D.S.R. 2022 Electrical Item No. 5.15
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. D.S.R. 2022 Electrical Item No. 5.12
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. D.S.R. 2022 Electrical Item No. 2.10.4
SUBHEAD V-CABLES Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the make:Schneider/RR Kabel/Northwest 120 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(o)
50 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(l)
35 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(k)
25 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 501(j)
10 sqmm 4 core PWD SOR Electrical 2018 ITEM No. 501(h)
10 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 501(b)
6 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 501(a)
Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire make:Schneider/RR Kabel/Northwest 120 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(o)
50 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(l)
35 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(k)
25 sqmm 3.5 core PWD SOR Electrical 2018 ITEM No. 503(j)
10 sqmm 4 core PWD SOR Electrical 2018 ITEM No. 503(h)
10 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 503(b)
6 sqmm 2 core PWD SOR Electrical 2018 ITEM No. 503(a)
Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. make:Schneider/RR Kabel/Northwest 120 sqmm PWD SOR Electrical 2018 ITEM No. . 504(j)
70 sqmm PWD SOR Electrical 2018 ITEM No. 504(h)
50 sqmm PWD SOR Electrical 2018 ITEM No. 504(g)
35 sqmm PWD SOR Electrical 2018 ITEM No. 504(f)
25 sqmm PWD SOR Electrical 2018 ITEM No. 504(e)
16 sqmm PWD SOR Electrical 2018 ITEM No. 504(d)
10 sqmm PWD SOR Electrical 2018 ITEM No. 504(c)
6 sqmm PWD SOR Electrical 2018 ITEM No. 504(b)
SUBHEAD IV-MAIN L. T. PANELS LT PANEL & FEEDER PILLAR Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. L.T. PANELS Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main LT Panel make:Schneider/RR Kabel/Northwest Incoming : One (1) No 200 Amp. 4P MCCB of 50KA Breaking capacity mtring : 1 Set of CT's one of 200/ 5Amp ratio for Multifunction mtr 1 Set of CT's one of 200/ 5Amp ratio 50/51 1 Set of CT's one of 200/ 5Amp ratio for APFC relay. One (1) Set of Phase Indication Lamp. One (1) Set of B+C Type SPD Bus Bar : One (1) No.300 Amp.TPN aluminimum bus bar of suitable length.50KA Outgoing : Phase indication lamps on nos outgoing to be provided. 02 No.125 Amp 4P MCCB. (25 KA) 01 No.100 Amp 4P MCCB. (25 KA) 03 No.63 Amp 4P MCCB. (25 KA) 04 No.10 Amp DP MCCB. (10 KA) Panel described as above N.S
SUBHEAD IV-MISCELLANEOUS Providing, Laying and Fixing following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 100mm dia DSR -2022 E/M Item No. 14.14.1
Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortaConstructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5r including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 900 mm x 900 mm x 1000 mm deep DSR 18.34.1
SUBHEAD VIII- SAFETY EQUIPMENTS Providing and fixing MV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. DSR -2022 E/M Item No. 2.21
Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. DSR -2022 E/M Item No. 2.22
Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. PWD SOR ELECTRICAL 2018 ITEM NO. 1133
Supplying & Laying of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality PWD SOR ELECTRICAL 2018 ITEM NO. 1136
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T & P for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1134
Supply and fixing of fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1131
Supply and fixing of CO2 type fire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. PWD SOR ELECTRICAL 2018 ITEM NO. 1132
ELECTRICAL WORKS SCHEDULE ITEMS (AS PER PWD SCHE. 2018/DSR 2018/2019) NON - SCHEDULED ITEMS (AS PER MARKET RATES ) SUBHEAD I- WIRING POINTS Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. make:Schneider/RR Kabel/Northwest DSR ELECTRICAL 2022 ITEM NO. 1.3.1 (Group A)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc .as required. make:Schneider/RR Kabel/Northwest DSR ELECTRICAL 2022 ITEM NO. 1.4
Same as item No.(1) but for 5 amp plug point with piano type switch and socket etc. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 141©
Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. Addition for light / fan points with modular type switch in place of piono type switch. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 187(A)
Addition for plug points with modular type switch in place of piono type switch. make:Schneider/RR Kabel/Northwest PWD SOR ELECTRICAL 2018 ITEM NO. 187(C)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. required for proper completion of the work as directed by Engineer I/C. make:Schneider/RR Kabel/Northwest 2X 1.5sq. mm + 1 X 1.5 sq. mm earth wire DSR 2022 (E/M) Item No. 1.14.1
2X4 sq. mm + 1 X 4 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.3
2X 6 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.4
2X10 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.5
2X10 sq. mm + 1 X 6 sq. mm earth wire make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.14.6
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.1 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.2 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) Item No. 1.21.3 32 mm
SUBHEAD III-DISTRIBUTION BOARD Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) make:Schneider/RR Kabel/Northwest 8 way , Double door DSR 2022 (E/M) 2.3.2
12 Way Double door DSR 2022 (E/M) 2.3.2
Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A) make:Schneider/RR Kabel/Northwest 1002
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp. DSR 2022 (E/M) 2.13.2
40 Amp. DSR 2022 (E/M) 2.13.2
Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. make:Schneider/RR Kabel/Northwest 1139
Supply and fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work. make:Schneider/RR Kabel/Northwest 1139(A)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. make:Schneider/RR Kabel/Northwest DSR 2022 (E/M) 2.11
SUBHEAD IV-EARTHING Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required. DSR 2022 (E/M) 5.6
Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm DSR 2022 (E/M) 5.9
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. DSR 2022 (E/M) 5.12
SUBHEAD V-MAIN L. T. PANELS PANEL Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. make:Schneider/RR Kabel/Northwest The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm mtr PANEL Incoming : One (1) No 100 Amp. 4P MCCB of 25KA Breaking capacity mtring : One (1) No. Sets Multifunction mtr nos incoming One (1) No. of Phase Indication Lamp nos incoming Bus Bar : One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. 01 No.63 Amp 4P MCB. (10 KA) 19 No.63 Amp DP MCB. (10 KA) 02 No.40 Amp DP MCB. (10 KA) Panel described as above. N.S
SUBHEAD V-MAIN L. T. PANELS PANEL Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. make:Schneider/RR Kabel/Northwest The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm mtr PANEL Incoming : One (1) No 100 Amp. 4P MCCB of 25KA Breaking capacity mtring : One (1) No. Sets Multifunction mtr nos incoming One (1) No. of Phase Indication Lamp nos incoming Bus Bar : One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on nos outgoing to be provided. Phase indication lamps on nos outgoing to be provided. 01 No.63 Amp 4P MCB. (10 KA) 07 No.63 Amp DP MCB. (10 KA) 02 No.40 Amp DP MCB. (10 KA) Panel described as above. N.S
FAN & LIGHTS Supply of 80W drop down pole mounted type LED decorartive light fixture with system efficacy of min. 110 lm/W, CCT 3000K, IP 66 & IK 08, Spun aluminum powder coated housing with casted aluminum heat sink, Optical grade injection moulded polycarbonate diffuser with in-built Surge protection of 6kV and External Surge protection of 10kV. Including with 1. Supply of 8 mtr high hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thk. HR sheet alongwith base plate of size 200X200X16mm thk. (Without bracket, foundation bolt, Bakellite sheet) with PU Paint 2. Supply of 1000mm long hot dip galvanised standard type double arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70mm A/F. with PU paint 3. Supply of 4Nos of M20X600 long 'J' type EN 8 grade foundation bolts along with template 4. Supply of BAKELITE SHEET OF SIZE 275X75X4MM THK WITH STUD TERMINALS & 2 NO. 6A SP MCB. MODEL NO. EPC-SL-24-8M-DECO-OP-GAD-001 Make: Bajaj
Providing & Fixing Spike Light with all complete Fitting. (SPYKZ BGSBL 9W LED WW) LED Spike/ Bush light with die-cast aluminium housing designed for rugged outdoor usage & IP65 protection. Make Bajaj Market Rate
Providing & Fixing Wall Focus Light AMAZE (BJFL 50W LED I) A resilient floodlight with toughened glass, aluminum housing, IP66 protection. Experience superior lighting for industrial and commercial settings. Make Bajaj/Philips Market Rate
Providing & fixing Wall Bracket Light FAÇADE -6434-3w Make Bajaj, Philips
P/F 15W Leaser Cut LED Bollard light with name/logo engraved at the Top_900MM Algarve/Muster Bollard Make Bajaj
P/F 4M Tringa Column light with remote control TRI-Colour Light Column-4M BLSLC 50W LED TRI 4M Make Bajaj, Philips Market Rate
P/F 30W AIO LED Solar street light(Hybrid) with 5M octagonal pole Model No. 30W-SOLAR BSZSL 30W LED HYB-STANDARD HYBRID Make Bajaj
Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-38 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. Make : Bajaj PWD Electrical SOR 2018
CCTV CAMERA SYSTEM Supply, , Installation Testing and Commissioning of 4 MP IP, 5 inch PTZ camera with 32*Zoom & 150 Meter IR with SD card supported. IP 67, Focal length 4.5 to 153mm, Frame rate max. 25/30fps, max. resolution 2560*1440 & Image Sensor 1/2.5'' progressive scan CMOS. Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A-4)
Supply, , Installation Testing and Commissioning of IP Bullet Camera IR type with the following specification Minimum 2.0 MP resolution, IP 67, 0.2 lux at F 1.2, 1/3" DIS, 3.6mm fixed iris lens. Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A-4)
PVC junctin IP rating 65 suitable for CCTV camera work. Belden/Siemon/Panduit/Derwiser/ Rit
Supply, laying and testing of unshielded twisted pair CAT 6 network cable (Violet Color) confirming to TIA/EIA standards, in heavy class FRLS PVC pipes / conduits, rate shall include necessary accessories all complete as required. Cost to include dressing the cable with proper accessories, proper addressing of cables using ferrules. labelling and end to end signal continuity testing for all ports. The wires shall be of different colours as required. Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A-9)
Supply, laying and testing of unshielded twisted pair armoured CAT 6 network cable (Black Color) confirming to TIA/EIA standards. Rate shall include necessary accessories all complete as required. Cost to include dressing the cable with proper accessories, proper addressing of cables using ferrules. labelling and end to end signal continuity testing for all ports. The wires shall be of different colours as required. Belden/Siemon/Panduit/Derwiser/ Rit
Supply, fixing, tesing & commissioning of CAT - 6, 8 position, 8 wire, network RJ 45 Connectors including crimping, testing end to end connectivity and necessary acessories all complete as required. Belden/Siemon/Panduit/Derwiser/ Rit
Supply, fixing, tesing & commissioning of RJ 45 In line Coupler Ethernet Network Cable Extender Connector including testing end to end connectivity and necessary acessories all complete as required. Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A7)
Patch Panel Supply, installation, tesing & commissioning of 24 Port loaded patch panel CAT6 (1U with rear wire manager) silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections Make: Belden/Siemon/Panduit/Derwiser/ Rit
Switch Panel Supply, installation, tesing & commissioning of 24 Port PoE Network switch 10/100/1000 GBps, managed type (1U with rear wire manager) with silver-plated IDCs (insulation displacement connection) for secure, reliable gas-tight connections. Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A6)
Network Rack Supply, installation, tesing & commissioning of 6U rack with glass fronted door, lockable arrangement along with power bus, ventilation fans including necessary fixing accessories all complete as required Belden/Siemon/Panduit/Derwiser/ Rit
Supply, fixing and checking connectivity of Patch cords (1m) CAT6 (RJ45 with moulded boots) at switch end Belden/Siemon/Panduit/Derwiser/ Rit
Supply , fixing and checking connectivity of Patch cords (1m) CAT6 (RJ 45 with moulded boots) at user end Belden/Siemon/Panduit/Derwiser/ Rit
Supply, Installation Testing and Commissioning of 32 channel Network Video Recorder (NVR) with TCP IP, RS 232, RS 485 Connectivity capable of handling Up to 5 MP cameras, 4k HD, 30 FPS and shall be ONVIF compatible. The NVR shall be suitable for connecting multiple HDD (SATA / eSATA) of 8 TB capacity. The NVR shall have provision for multiple HDMI / VGA simultaneous output and also audio output. The cost to include setting up, commissioning of system all complete as required Belden/Siemon/Panduit/Derwiser/ Rit (ANNEXURE-A3)
GIGA byte switch 8 port. Belden/Siemon/Panduit/Derwiser/ Rit
Supply, and Installation of following capacity Hard disk drives for storing the recorded data - 8TB WD/Seagate/Sandisk (ANNEXURE -A2)
Supply, Installation, Testing and Commissioning of LCD / LED monitor capable of displaying the output of the CCTV system in the location specified at site- 31.5 inches TV with KVM splitter & HDMI cable. Make: LG/Sony/Samsung (ANNEXURE-A1 ATTACHED)
PULZ CS5FR SPEAKER SYSTEM Make : Bosh/JBL/Viewsonic
BRACKET OF CS5FR Make : Bosh/JBL/Viewsonic
PULZ AD4820 4 CHANNEL POWER AMPLIFIER Make : Bosh/JBL/Viewsonic
PULZ DSS88 SPEAKER MANAGEMENT SYSTEM Make : Bosh/JBL/Viewsonic
PULZ XO23 CROSSOVER Make : Bosh/JBL/Viewsonic
32 U EQUIPMENT RACK Make : Bosh/JBL/Viewsonic
RACK CABLES AND CONNECTORS FOR SPEAKERS
2.5sqmm armoured speaker cable
4 sqmm armoured speaker cable
Interconnects
Installation, Testing & Commissioning.
Plantation of Trees, Ground Clearing, Excavation of upto 1 feet and refilling with soil of 1.5 feet depth (compacted),Disposal of excavated material from site, Laying irrigation pipelines, adding organic soil enhancers as per approved list including providing and planting of hedges as per approved list ensuring bamboo support for saplings, laying mulching materials, logistics and transport for daily watering of plantation, daily maintenance and watering for 3 years, ensuring maintenance of water tanks and pipelines, de-weeding on quarterly basis, preparing Monitoring Reports, submitting Monitoring Reports, Maintenance of all the trees, plants, shrubs, hedges, lawns and flower bed preparation by uprooting the old plants for sowing planting of new seedlings (seasonal and perennial both) and different types of cutting including earth work, spreading and mixing of manure and fertilizers and levelling and bund making etc. To prepare and maintain flowers and plant pots with flowers and plants both indoor and outdoor at designated places to be decided in consultation with the designated officer. This job also includes regular watering of grass, lawns, trees, shrubs, plants etc. Spraying of insecticides, pesticides, weedicides on the plants as and when required, removing the waste to the proper place. Intercultural operation and maintenance of the plants both in flower beds and pots including preparation of soil mixture (manure, soil, fertilizers), weeding, liming, manuring, filling of pots with soil mixture, cutting of hedges, grass cutting in lawn and lifting the grass to the compost pit. Any other job which is required to make the campus from Horticulture point of view beautiful with lush green Lawns. This rate includes necessary tools and equipments etc.
Supply & plantation of Trees upto 8ft to 10ft height well settled, all indigenous varieties (local) as per listed below, location and quantities shall be as per drawing Mangifera Indica (Mango), Bacopa Monnieri (Brahmi), Terminalia Tomentosa (Asna), Azadirachta Indica (Neem) & Bambusa Bambos (Baans) Terminalia Arjuna (Arjun), Tectoria Grandis (Sagaun), Shorea Robusta (Saal), Stereospermum Tetragonum (Padal), Anogeissus Latifolia (Bakli), Madhuca Longifolia (Mahua) & Diospyros Malabarica (Gaub) Saraca asoca (ashok), Ficus religiosa (peepal), Ficus benghalensis (bargad), Aegle marmelos (bel) & Phyllanthus emblica (aonla) Pterocarpus Santalinus (rakta chandan), Butea monosperma (dhaak), Artocarpus altilis (kathal) & Santalum album (chandan) Saraca Asoka (Sita Ashok), True Cinnamon (Nag Kesar), Mangolia Champaca (Champa) & Mimusops Elengi (Maulsari) Saussurea Ggossypiphora (Mratyusanjeevani), Azadirachta Indiac (Neem) & Adiantum Venustum (Hansraj)
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area. (two application) i/c cost of chemical) and as per direction of officer-in-charge.and as per direction of officer-in-charge.
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 2.33 (dsr hort. 2020)
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 2.13 (dsr hort. 2020)
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). 2.25 (dsr hort. 2020)
Providing and stacking of plant Mogra of height 25 to 30 cm., 2 to 3 branch in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. 4.88 (dsr hort. 2020)
Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge. 4.91 (dsr hort. 2020)
Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge. 5.13 (dsr hort. 2020)
Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge. 5.17 (dsr hort. 2020)
Providing and Displaying Ficus Starlight with fresh, healthy and attractive foliage 45 to 60 cm spread 75 to 90 cm ht., specimen bushy ,in 35 cm Cement Pot as per direction of the officer-in-charge. 5.28 (dsr hort. 2020)
Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.1 (dsr hort. 2020)
Providing and stacking of Asparagus marrie, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.3 (dsr hort. 2020)
Providing and stacking of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.10 (dsr hort. 2020)
Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 6.14 (dsr hort. 2020)
Providing and stacking of Ophiopogon jaburan (variegated) ,full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 6.21 (dsr hort. 2020)
Providing and stacking of Alstonia scholaris of height 150-165 cm. in bagof size 25 cm as per direction of the officer-in-charge. 7.4 (dsr hort. 2020)
Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.8 (dsr hort. 2020)
Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.13 (dsr hort. 2020)
Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 7.17 (dsr hort. 2020)
Providing and stacking of lotus flower of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. Mr
Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.2 (dsr hort. 2020)
Providing and stacking of Calliandra hybrida of height 105-120 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 8.7 (dsr hort. 2020)
Providing and stacking of Cassia laevigata of height 45-60 cm. in earthenpots of size 20 cm as per direction of the officer-in-charge. 8.11 (dsr hort. 2020)
Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. 8.14 (dsr hort. 2020)
Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 8.54 (dsr hort. 2020)
Providing and stacking of Allamanda violacea of height 30 cm to 45 cm. in poly bag of size 20 cm as per direction of the officer-in-charge. 9.2 (dsr hort. 2020)
Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge. 9.6 (dsr hort. 2020)
Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 9.14 (dsr hort. 2020)
Providing and Stacking of Anjeer of height 75-90 cm. in poly bagsof size 25 cm as perdirection of the officer-in-charge. 11.1 (dsr hort. 2020)
Providing and Stacking of Satavari, well developed in earthen pot of size 20 cm as per direction of theofficer-in-charge. 11.6 (dsr hort. 2020)
Providing and Stacking of Sarpgandha well developed in poly bag of size 20 cm as per direction of theofficer-in-charge. 11.14 (dsr hort. 2020)
Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 11.17 (dsr hort. 2020)
Providing and Stacking of Aprajita White well developed in poly bag of size 20 cm as per direction of the officer-in-charge. 11.18 (dsr hort. 2020)
IRRIGATION SYSTEM DRIP IRRIGATION SYSTEM FOR PLANTATION - A SYSTEM HEAD UNIT SNAD FILTER + BACKWASH ASSLY 2.5" Make : Astral/Apollo/Prince
SCREEN FILTER 2.5"
ASSLY FOR FILTER 2.5"
PRESSURE GAUGE + STOP COCK
NETWORK - FINOLEX HDPE & PVC PIPES HDPE PIPE 75 MM PN4 (TANK TO PLOT) Make : Astral/Apollo/Prince
PVC PIPE 75 MM 4KG/CM2 Make : Astral/Apollo/Prince
PVC PIPE 63 MM 4KG/CM2 Make : Astral/Apollo/Prince
EMITTING SYSTEM FINOGOL PLAIN LATERAL 16 MM
DRIPPER 8 LPH
START TO END SET FOR DRIP LINE 16 MM
BARBED COUPLER 16 MM
TEE 16 MM Make : Astral/Apollo/Prince
ELBOW 16 MM Make : Astral/Apollo/Prince
ELBOW 16 MM Make : Astral/Apollo/Prince
BALL VALVE 63 MM Make : Astral/Apollo/Prince
FLUSH VALVE 63 MM Make : Astral/Apollo/Prince
VALVE BOX 12" Make : Astral/Apollo/Prince
Pump: Crompton Greaves 10.00 Hp pump with necessary accessories.(Market Rate) Make: Crompton Geaves/ Kirlosker
Poviding & Fixing Designer dust bin with all complete fitting
Providing & Fixing of Stainless Steel Racks with all complete fitting
AMBE INFRAPROJECTS PRIVATE LIMITED (BID ID -5277723)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid