Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC AL AMEEN MANZIL THELLAKOM P O KOTTAYAM | KOTTAYAM | KERALA | 686001 | L1 | Accepted-AOC L1 |
Tender Value
₹2.4 L
EMD Value
₹3,550
Closing Date
25 Oct 2023, 5:00 pmClosed
Chairman and Managing Director KPHCC
KERALA POLICE HOUSING AND CONSTRUCTION CORPORATION LTD CHANDRASEKHARAN NAIR STADIUM, PALAYAM, THIRUVANANTHAPURAM - 695033
Providing Infrastructure Development in Railway Police Station, Kottayam (Re)
2023_KPHCC_612923_1
NIT No.103/KPHCC/2023-24
Open Tender
Civil Works - Buildings
Item Rate
60 days
Kottayam
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
₹3,550
13 Nov 2023
16 Oct 2023
27 Oct 2023
16 Oct 2023
25 Oct 2023
16 Oct 2023
16 Oct 2023 - 25 Oct 2023
Amount
Civil works
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
50.12.4.2 : Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
od182909/2022_2023 : EXECUTIVE TABLE WITH SIDE TABLE <br>Table fully made of 25 mm thick table top & frame made of<br>18 mm thick prelaminated particle board,knock down<br>fitting ,level adjusters ,Visible edges are lipped with 2 mm<br>PVC edge band other edge with 0.5 mm edge band, table top 10 cm and 5 cm partition One<br>draw One cupboard unit and 75 cm Ht cupboard on left<br>side.Prelam keyboard, Lock, Key, Handle etc.<br>Main Desk: 135x60x75(H)<br>Drawer/Side table: 40x45x75(H)<br>Cupboard: 45x45x75(H) design as per the direction in engineer in charge
Electrical works
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
od187683/2023_2024 : Supply,marking,crimping RJ45 connectors /sockets and fixing to the existing enclosure and giving connection etc complete
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
od187679/2023_2024 : Supply ,installation ,testing and commissioing of CAT6 patch cord 2 mtr. make- dlink or equivalent
od187680/2023_2024 : Supply and fixing of CAT6 I/O socket in the existing suitable modular plate and suitable gi box ,giving proper connection as required
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
od182990/2022_2023 : Supply installation testing and commissioning of 4feet 20W led batten with 2000 Lumens ,50000 burning hours,all accessories ,electrical connections.including fixing materials required. make-philips/wipro/havells or equivalent
Bidder Name
Najeeb K Y
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_916647.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .