Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS Dehradun
HQ CWE HILLS Dehradun, Mall Road, Dehradun Cantt-248003
SPL REP TO BLDG NO P-317 OF 262 FD REGT AND BLDG NO 309 OF 6 MTN ARTY BDE SIG COY AT RAIWALA MIL STN
2022_MES_550451_2
86376/RWL/E8
Open Tender
Civil Works
Item Rate
270 days
AGE(I) Raiwala
Class C Category a (i)
8 documents required · 8 mandatory
₹1,000
AGE(I) Raiwala
₹1.2 L
Yes
26 Dec 2022
1 Nov 2022
28 Nov 2022
1 Nov 2022
21 Nov 2022
8 Nov 2022
Amount
Removal of existing roof treatment i.e APP membrane incl cement screed, brick tiling including mud mortar or demolition of lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material and removing unserviceable material,outside of A-1 defence land complete all as specified and directed.
Demolition of existing roof treatment i.e APP membrane incl cement screed and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance, scales, oil or any other loose material and removing unserviceable material, outside of A 1 defence land complete all as specified and directed. Note for item of roof treatment : - (a) The work is required to be carried out at non-accessible roof for double storey. The contractor shall make arrangement of scoffolding, safety & security of workers and arrangement for approach to roof . (b) The rates quoted shall deemed to be included for these items. (c) The work will be measured only after stage passing by AGE (I).
Demolition of reinfocement cement concrete (reinforcement cut as required to facilitate demolition) as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC downward facia of roof projection and similar suspended work incl removing the debris from site to out of MoD land complete all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone agg mixed with liquid water proofing compound (mixed as per manufacturer direction) and finishing the surface even and smooth without using extra cement as in roof padding including making the V-groov on top surface10 mm deep and filling solidly with a hot mixture of bitumen and clean dry sand in the ration of 1:1 by weight complete all as specified and direction. Note :- 1. Liquid water proofing compound will be measured and paid seperately..
M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared and applied as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface.
M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) 15mm thick cement plaster in CM (1:4) over the roof surface. (c) Providing APP based 5 layer polymeric membrane minimum weighing 3.6 Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (d) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance. Note : The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.
M&L for PCC (1:1.5:3) type A-0, using 12.5mm stone aggregate as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging ) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction) complete all as specified and directed. Note :- Integral water proofing compound will be measured and paid seperately.
Supply only Liquid intergal water proofing compoud (ISI Marked) complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sqm each and refixing the same in other opening of any descrption after easing and adjusting, complete all as specified and directed.
Refixing (including taking down) of shutters in same opening of any descrption after easing and adjusting, area exc 1 Sqm but n'exc 2 Sqm each complete all as specified and directed.
M&L for mild steel fastner of size 200 to 250mm for fixing wooden door frame and like in postion complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable and variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
50mm x100mm size
65mm x100mm size
65mm x 125mm size
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter (single & double leaf both)of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complet all as specified and directed.
M&L for 30mm thick factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed.
S&F 30mm thick factory made 100% solid WPC window glazed shutter / wire mesh shutter 95 mm x30mm thick. Made from WPC material with density not less than 800 kg/cum. All four corner are fusion welded & screwed with 8 x 50mm self-screws for additional strength. After joining all 4 corner clear space to be paneled with 4mm thick glass / S S mosquito mesh after glazing of inside of shutter 10 x 12mm pvc “L” shape bead to be nailed or sticked with shutter complete all as specified and directed. Note: - Glass pane, wire mesh and grill are measured and paid separately at relevant item
S&F steel windows with side hung shutters (glazed and gauged shutter both) including box type hinges with steel handle, Z-section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed. Note :- Measurements shall be taken and paid compositly for frame, glazed and gauged. Grill shall be measured and paid seperately under respective item. No extra claim shall be entertained on this ground.
S&F steel ventilators with top hung shutter including box type hinges with steel handle, and Z-section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for centering & shuttering of scaffolding for existing RCC roof slab for repair of supporting brick work to support the RCC slab for the period from dismantling of brick wall to further construction of brick wall up to ceiling height (scaffolding will be of iron plate & MS pipe, jack for suitable strength to hold the existing RCC slab load
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one.
S&F glazing with plain sheet glass, ordinary quality, 4mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane. complete all as specified and directed.
S&F stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples. complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. complete all as specified and directed.
M&L for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality over a one coat of red oxide complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ- 150) joints, ridges, hips, valleys/rain water / roof covering/cladding to wallas in crumple, fixed with self-tapping screws and washers of 68 mm fine thread for MS Pipe purlin and double threaded for wooden purlins as per sutaible distance complete all as Specified & directed.
S&F stainless steel tower bolt of following length complete all as specified and directed :-
100mm length
200mm length
300mm length
S&F stainless steel handle of following size complete all as specified and directed :-
Size 150mm
Size 125mm
S&F for stainless steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed
S&F stainless non megnetic steel butt hinges of size 100mm (ISI Marked) complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150mm complete all as specified and directed.
S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed.
S&F in repairs stainless steel non magnetic curtain rod 25 mm dia with and including fixing brackets and decorative type knobs both side of each rod complete all as specified and directed. Note: - Measurement will be taken between end point of knobs”
S&F aluminium door seal upto 1200mm long on bottom of door complete all as specified and directed.
S&F in repair stainless steel peg set, 150mm complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed. Note:- This item will not be executed where PCC of sub base also demolised.
M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8mm thick, as in dado etc including 10mm thick rendering in CM (1:3), set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I)
M&L for rubbing and polishing to old kota stone flooring to give high gloss (mirror) finish complete all as specified and directed.
Roughening surfaces of old concrete floor by tucking, picking, sweeping clean and washing down with water to remove dust etc to receive the screed layer for laying floor tile complete all as specified and directed.
M&L for 18-20mm thick machine cut pre polished kota stone slab flooring over cement screed base laid and incl 20mm thick cement screed bed in CM (1:3) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing (mirror polished) to give high gloss finish complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B0, using 12.5 mm graded aggregate) as in sub base of flooring, as levelling course complete all as specified and directed.
M&L for 10-12mm thick machine cut pre polished kota stone slab as in riser of steps in full lenth single peace without joint, skirting , of stair width laid over and incl 10 mm thick rendering in CM (1:3) and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing (mirror polished) to give high gloss finish complete all as specified and directed.
M&L for RCC (1:2:4) (Nominal Mix) type B1, using 20mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed.
M&L for RCC (1:2:4) (Nominal Mix) type B-0, using 12.5 mm graded stone aggregate as in chhajjas/ fins / facia for minor repair including formwork including one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed. Note:- (i) (SBR) latex liquid polymer will not be measured and paid seperately. (ii) The work is required to be carried out at for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L for RCC (1:2:4) (Nominal Mix) type B1, using 20mm stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, RCC band and similar work complete all as specified and directed.
M&L for RCC (1:2:4) (Nominal Mix) type B1, using 20mm stone aggregate as in foundations, including rafts, foundation beams, plinth beams, bases for columns etc basement slabs,under-reamed piles complete all as specified and directed.
M&L for RCC (1:2:4) (Nominal Mix) type B1, using 20mm stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exce 200 mm thick, rough finished flat surface of concrete complete all as specified and directed.
M&L for drilling 12mm dia x 200mm deep in various structrural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with epoxy acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical or equivalent of approved make complete all as specified and directed.
M&L for TMT bars 10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of following capacity of tank complete all as specified and as directed:-
Capacity 500 Ltrs
Capacity 1000 Ltrs
Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :-
15mm bore
20mm bore
S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
15mm bore
20mm bore
Refixing old galvanised steel water tubing, with all new fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
20mm bore
M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work of girth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed.
S&F in repair 20mm dia gun metal, globe or gate valve with Iron wheel head Screwed both ends for Iron Pipe and complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar (1:6) with old size bricks complete all as specified and directed..
M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) with old size bricks complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L for 10mm thick rendering in CM (1:3) in ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete walls internal surfaces in CM (1:6) finished to even & smooth without using extra cement. complete all as specified and directed.
M&L for 15mm thick rendering on concrete / brick walls surface in two coats, first coat of 10mm in CM (1:6) & 2nd coat of 5mm in CM (1:4) mixed with integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and directed. Note :- Integral water proofing liquid will be measured and paid seperately.
M&L for preparing old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coats of white wash complete all as specified and as directed.
M&L for three coats of white wash on new ceiling surfaces including preparation of surfaces complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge.The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.
M&L for preparation of old decorated surface of interior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of old decorated surface of exterior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint of required shade (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.
Note for all item No 68 to 71:- (i) The old/ new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour and T&P required for preparation of surface are demand to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) Before commencing the work, contractor will got the written approval from GE/ AGE (I) for the make and colour / shade (tint). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.
M&L for Non- skid coloured ceramic tiles of any design and pattern, 7 to 8 mm thick, of following size, as in floor etc with and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed :- Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I).
Area of each tile exc 0.06 Sqm but not exc 0.11 Sqm.
M&L for PCC (1:4:8) type D-2, using 40 mm graded crushed stone aggregate as in mass concrete, sub base of floor/ hard standing / footpath etc complete all as specified and directed.
S&F in repairs 15mm bore stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions.
S&F in repairs 15mm bore chromium plated bib taps, long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F 600 mm long towel rail fixed with and including chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms) complete all as specified and directed.
S&F brass CP urinal spreader fixing with 15 mm dia pipe. complete all as specified and directed.
S&F chromium plated soap dish complete all as specified and directed.
S&F in repairs 125 mm size shower rose chromium plated with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. Note for all item of Chromium plated :- - Chromium plated fitting shall be brought in store yard first as approved by AGE(I) and will be issued subsequently for fixing at site
S&F glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long. complete all as specified and directed.
S&F for PVC Connections 15mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repair wash hand basin (Padestal pattern) 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including CP waste fitting of 32 mm complete all as specified and directed.
S&F in repairs for grating, round 127 mm dia, chromoum plated complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity complete all as specified and directed.
S&F in repairs vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor complete all as specified and directed.
S&F in repair vitreous china half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F 32mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per Sqcm fixed to walls, ceilings or in floors etc complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia, jointed in cement mortar and taking out of trenches if required, including clamps complete all as specified and directed..
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size complete all as specified and as directed :-
110 mm bore
75 mm bore
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends of any radius. complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified and directed.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm bore PVC (SWR) Multi floor trap including jointing with solvent cement, complete all as specified and directed.
S&F 110mm bore PVC (SWR) P Trap, complete all as specified and directed.
S&F 75mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement .complete all as specified and directed.
S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :-
100mm bore pipe
75mm bore pipe
M&L for prepolished chequered cement concrete tiles 300X300X25 mm thick, (ISI marked) rubber finished, as in floors with and including 20 mm thick screed bed in cement mortar (1:4) jointed with grey cement slurry mixed with pigment to match the shade of the tiles including removal of old materials from site not exceeding 100 meter complete complete all as specified and directed
M&L for PCC (1:2:4) type B1, 20 mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F rolled mild steel work of Fe-290 (Gde E-165) as in framed work, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
S&F expanded metal cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia., or fixing with steel staples to wood or steel members, weight not exceeding 4 Kg per Sqm complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto two storey buildings incl removing of small trees shrubs etc complete all as specified and directed. Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation in hard/ dense soil and getting out complete all as specified and directed.
Demolition and breaking up drain pipes, 100 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for PCC (1:4:8) type D2 bed to drain pipe 100mm dia including packing under and haunching against the sides of pipe complete all as specified and directed.
Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers (Soil) complete all as specified and directed.
Removal of excavated surplus (soil) at a distance exc. 1.5 Km but n. exc 5.0 Km complete all as specified and directed.
Dismantling and taking down carefully unservicable copper / aluminium point wiring (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall / floor etc, to match with the existing surfaces of wall / floor complete all as specified & directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down sub main/ service/ UG cable on wall / trenches/ roof / floor etc complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down carefully existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall / floor etc. complete all as specified and directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
Descrition same all as per item No 117 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
Descrition same all as per item No 117 above, but in existin conduit for one light/ fan/ exhaust fan/ call bell point controlled by one way 5 amp switch complete all as specified and directed.
S&F modular switch single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.
S&F modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white / ivory finish all as specified and directed.
S&F modular socket outlet, 6A - 2 / 3 pin combined, 2 module, 230 volts, 50 hz complete all as specified and directed.
S&F modular socket outlet, 16A - 2 / 3 pin combined, 2 module, 230 volts, 50 hz complete all as specified and directed.
S&F modular fan regulator, 120 W, 2 module complete all as specified and directed.
S&F ceiling rose 3 terminal / PVC / polycarbonate, isolated body complet all as speccified and directed.
S&F surface mounted LED luminiare 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF> 0.98 having over voltage protection up to 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency > 120 lumen per watt, internally pre wired through flexible wire connecting with ceiling rose all as specified and directed. Note :- The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
S&F new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on existing bracket including making necessary electric connection with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 volt grade complete all as specified and as directed. Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 02 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No.
S&F MCB DB SPN 6 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB DB SPN 8 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB, SPN, AC, 240 volts of 10-32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F sub main wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, stranded copper conductor cable as earth wire in and including rigid PVC conduit 25mm dia or higher, medium grade and earth wire connected to common earth dolly all as specified & directed. Note: Three run of 4 Sqmm cable and one run of PVC conduit shall be measured as one unit
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded by with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC Pit cover of 320 x 320 x 80 mm size (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including and provision of GI wire up to 7.5 m long with 15mm dia light grade GI Pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
M&L for fixing or passing through pipe, laid in trenches, fixed on wall or LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sqmm 2 core with required aluminium cable lugs, lugs should properly crimmping with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement complete all as specified and directed. Note: GI tubing required shall be measured and paid separately under relevant item of sch as supply only,
Excavation in trenches in soft/ loose soil but not exc 1.5 m wide and exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engg-in-Charge. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches complete all as specified and directed.
Supplying, laying and jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post /under culvert/ under road etc. for cable protection complete all as specified and directed .
M&L for road cutting and making good with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate of minium size 150mmX100 mm in respect of width and thickness complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .