Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Poor Work Performance report |
| 4 | Rejected-Technical | Rejected-Technical No similar Work as per NIT |
Tender Value
₹20.3 L
Closing Date
2 Feb 2022, 2:30 pmClosed
GM , HWP (Kota)
GM office, HWP (Kota)
Removal, cleaning, inspection and replacement of damaged tower sieve trays/internals of exchange unit towers at HWP (Kota) site
2021_HWB_663907_1
HWPK/MECH/2021/293
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
60 days
GM office, HWP (Kota)
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
GM office, HWP (Kota)
28 Apr 2022
21 Dec 2021
3 Feb 2022
21 Dec 2021
2 Feb 2022
23 Dec 2021
23 Jan 2022
Amount
"Removal, cleaning, inspection and replacement of damaged tower sieve trays/internals of exchange unit towers at HWP (Kota) site”
Opening of mass transfer trays manways and inspection of tray internal components made of SS 304L/316L plates by entering inside the XU towers. Each tray shall be checked for torque values for fasteners of tray components and down comer clearance to be checked & if required to be adjusted as per the requirement. Cleaning & removal of any sulphur, corrosion products etc. from each tray shall be carried out as per instruction of HWPK Engineer and details to be recorded. Manways shall be fixed back and torqued after completion of the job.
Opening of heat transfer (multi down comer) trays manways and inspection of tray internal components made of SS 316L plates by entering inside the XU towers and Waste Stripper. Each tray shall be checked for torque values for fasteners of tray components. Cleaning & removal of any sulphur, corrosion products etc. from each tray shall be carried out as per instruction of HWPK Engineer and details to be recorded. Manways shall be fixed back and torqued after completion of the job
Removal and re-installation of Tray (Mass & Heat transfer) for Tower's weld joint inspection:- Dismantling of tray as per EIC instruction, shifting material to above or below's trays to facilitate weld joint inspection Shifting of removed tray components to its position, fixing back the removed tray components after clearance from EIC and level checking using water level manometer to ensure a max. level difference of 3 mm by taking at least 10 readings at different locations on each tray and keeping the reference water column at a fixed place, torquing of fasteners
Removal of completely damaged trays in segments from tower, bringing it out through tower manholes, fixing back the new tray components and level checking using water level manometer to ensure a max. level difference of 3 mm by taking at least 10 readings at different locations on each tray and keeping the reference water column at a fixed place, torquing of fasteners. (Optional requirement to be exercised at the discretion of EIC for HWPK).
Cutting and removal of deposited sulphur in hard solid form from tower sump of cold towers by entering inside the tower.
Sulzer Chemtech Tower Field Services India Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .