| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.5 LAccepted-AOC AMBADI NEAR PAACHAKKIL BUS STOP MALAPARAMBA POST KOZHIKODE DISTT KERALA 673 009 | KOZHIKODE | KOZHIKODE | KERALA | 673009 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹82.5 L+₹3,477.07 (0.04%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹85.4 L+₹3.0 L (3.62%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹89.6 L+₹7.2 L (8.69%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹90.0 L+₹7.5 L (9.10%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹86.3 L
EMD Value
₹1.5 L
Closing Date
3 Sept 2024, 6:00 pmClosed
Shri Santosh Kumar Rai IDSE SE CWE NB
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
SPECIAL REPAIRS TO BLDG NO P-133 GYMNASIUM AT INS DRONACHARYA UNDER GE FORT KOCHI
2024_MES_659630_1
81122
Open Tender
Civil Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹0
₹1.5 L
Yes
8 Oct 2024
13 Jun 2024
5 Sept 2024
13 Jun 2024
3 Sept 2024
11 Jul 2024
Amount
Dismantling framed work timber scantlings framed/unframed 30 sq. cm and over in section, in any position complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
S&F for Kiln Seasoned Teak Wood (Approved by Badminton World Federation And Certified by Labosport Grade 1 – EN 14904 As Per Badminton World Federation Standards) Surface board finished with 21 mm thick, 50 to 85 mm width and in random length in tongue and groove shape incl game line marking for 02 Nos Badminton court, 01 No Basket ball court and 01 No Volley ball court. The edges of the boards will have a finger lock groove and the bottom side with air pass groove. The Installation: A vapor barrier will be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cell cushioning pads will be placed on the vapor barrier in perfect level at 350 mm c/c in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 8 to 10mm will be left open between the wooden flooring and the surrounding tiled area/wall complete all as specified and directed by Engineer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation.
M&L for Pine wood SPF runner/scantling of 70 mm X 45 mm treated with anti-termite solution and fixed on the bottom side to support the flooring with 10 mm thick EPDM cushioning pads by nails through the two wings at 350 mm c/c complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid Polyurethene Lacquer polishing of wooden floor including cleaning and preparing the surface by machine sander with floor sander machine including a coat of wood filler with two or more coats complete all as specifiedand directed by Engineer-in-Charge.
M&L for post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Supply and fix structural steel in roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing including distance pieces, cleats etc (Fe-290 Gd E-165) complete all as specified and directed.
M&L for preparation of new or old steel surfaces over 10cm width or girth and applying two coat of VX polymer based anti corrosive paint over a coat of anti corrosive primer complete all as specified and directed by Engineer-in-Charge.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/valley gutter, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M&L for chipping and removing all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars including the rent of tools, scaffolding complete at any height and and removal of debris to a distance not exceeding 100mtr complete all as specified and directed by Engr-in-Charge.
Supply and application of Nitobond EP (Manufactured by M/s Fosrock Chemicals India Ltd) epoxy bonding agent over the old concrete surface including the cost of all materials, rent of tools, scaffolding and cost of painting brushes etc complete all as specified and directed by Engr-in-Charge.
Supply and application of rust remover/converter (Rebaklense RR of M/s Fosrock Chemicals India Ltd) or Amandur (Manufactured by GK Technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application including the cost of all materials, rent of tools, scaffolding cost of brush etc complete all as specified and directed by Engr-in-Charge.
M&L for plastering with Nitobond SBR (Styrene butadin polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) including the cost of all materials rent of tools and labour charges etc complete all as specified and directed by Engr-in-Charge.
M & L for Glass Fiber Tissue (GFT) sports flooring 4.5 mm thick reinforced, anti slippery surface texture, PUR surface protection with high abrasion wear layer, Glass fiber scrim impregnation shock absorbing cushioned layer, high abrasion resistant wear layer "P " rated of any colour complete all as specified and directed by Engr-in-Charge.
Supply and provisioning Renderoc RG non-shrink cementitious micro concrete (max 120 mm thick) (Manufactured by M/s Fosroc Chemicals India Ltd) to any thickness for beam and column. Fluid micro concrete shall be mixed with 6mm down coarse aggregate and specified quantity of water and mixed using a power operated slow speed stirrer and pouring inside the form work including the cost of all materials, rent for tools, scaffolding, and labour charges, water tight formwork etc. all as per manufacturer instructions complete all as specified and directed by Engr-in-Charge. Note for item Nos 14 to 19: The items shall be executed by manufacturer's agent for which manufacturer and contractor will give separate guarantee for five years.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed.
M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick screed bed in CM 1:4 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L for vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade complete all as specified and directed by Engr-in-Charge.
All as per item No 21 & 23 above, but on vertical surfaces such as skirting, dados and risers to steps, etc complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles complete all as specified and directed by Engr-in-Charge.
M & L for 300 x 400/450 x 7 mm thick glazed coloured ceramic tiles on dado/skirting and risers to steps, set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade complete all as specified and directed by Engr-in-Charge.
M&L for 20mm thick screed bed in CM 1:4 for laying granite/chequered tile in stairs/parapet,etc complete all as specified and directed by Engr-in-Charge.
M & L for Granite of any type,16 to 18 mm thick, machine cut, bedded and jointed in with grey cement slurry mixed with pigment to match the shade of the slab as in cooking platform, steps & cills including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M&L for rounding to edges of stone slab one edge, such as in steps, cooking paltforms, and similar situations complete all as specified and directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-Charge.
M & L for pre powder coated snap grid frame work for false ceiling complete all as specified and directed by Engr-in-Charge.
S & F 5 mm thick plain embossed PVC false ceiling boards of size 600mmx600mm of density 600Kg/cum, plain colour decorative type fixed to GI/Aluminium grid frame work complete all as specified and directed by Engr-in-Charge. Make:- SMP NAGMA or equivalent as approved by GE.
S&F hangers 4mm dia GI wire adjusting level fixed to roof slabs/truss/rafters/purlins etc not more than 1200mm centre to centre at 8 to 12 mtr height complete all as specified and directed by Engr-in-Charge. Note for item No 30 to 33: Work will be executed at a height of 8 to 12 mtr.
M&L for prepration of old surfaces of internal wall by complete removal of existing treatement , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old treated surfaces of ceiling and applying one coat of distemper oil emulsion complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster of any description including tiles on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by the Engineer-in-Charge
M&L for rendering 5mm thick in CM 1:4 using WPC over 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement at any floor complete all as specified and directed by Engr-in-Charge. Note: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer and two coats of putty complete all as specified and directed by Engr-in-Charge.
M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Proffesional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable aluminium windows with frame and grills any size complete all as specified and directed by Engr-in-Charge.
S&F pre powder coated aluminium louvers with frame (fixed type) with one or more rebates including joining cleats for fixing etccomplete all as specified and directed by Engr-in-Charge.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators, cup boards, partitions with 'C'/'F'/'H' beading/ frame for grills/wire mesh, etc with extruded built up standard tubular sections with necessary jointing aluminium cleats using C.P/ stainless steel screws, including seal the gap between the frame and wall with silicone sealant complete all as specified and directed by Engr-in-Charge.
S&F powder coated aluminium door shutters with extruded built up standard tubular sections using aluminium sec not less than 2.00mm thick (shutter with styles 85mmx44.45mm, top rails 83.5mmx44.45mm, intermediate rail 83.5mmx44.45mm, bottom rail 114.3mmx44.5mm) and glass 5 mm thick fixing to shutter with rubber neoprene/EPM gasket and aluminium beading, 02 Nos 150mm handle, 01 No 250mm long sliding door bolt and 02 Nos 150 mm tower bolt to each shutter using CP/stainless steel screws complete all as specified and directed by Engr-in-Charge.
S&F standard aluminium deco grills (DG 101, 7 mm thick) including making arrangement for opening window, grill shall be fixed with suitable clip beading /clamps complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium powder coated window (frame with shutters) shall be of openable casement type (34 mm Series) with and including 4 mm thick tinted glass/frosted with glazing beading & rubber/EPDM gasket. Each shutter provided with powder coated aluminium 01 Nos handle and 02 Nos stainless steel friction stay hinges complete with following sections of HINDALCO or equivalent complete all as specified and directed by Engr-in-Charge. (a) "H" frame 44.50 x 34.00 x 2.00 mm Section No 2082 (b) "Z" shutter 34.00 x 44.50 x 2.00 mm Section No 4124 (c) Mullion 57.00 x 34.00 x 25.00 mm Section No 9139 (d) Jointing cleat 50.00 x 50.00 x 4.9 mm Section No 2081 (e) Glazing Beading 25.00 x 24.00 x 1.2 mm Section No 4135
Supply and fix aluminium powder coated sliding window shutters consisting of aluminium sections not less than 1.5 mm thick, each shutters fixed with 5 mm thick plain glass with EPDM/ rubber gasket, fixed with jointing cleats and necessary locking arrangements to left and right shutter and 02 Nos rollers to each shutter complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
Disconnecting existing PVC water tanks exc 500 and not exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position complete all as specified and directed by Engr-in-Charge.
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge.
Supplying and laying of CPVC pipes of outer dia 20mm, SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings and specials complete all as specified and directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed in any length with GI step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls / laid in floors complete all as specified and directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable rolling shutter of any size complete all as specified and directed by Engr-in-Charge.
M & L for perforated aluminium rolling shutter made from 37 mm perforated aluminium, blind, surface 37 mm, avg weight per sqm L:7.3 kg coffe brown colour including necessary items for fixing in position of opening complete all as specified and directed by Engr-in-Charge.
S & F in repairs vitreous china wash down water closet (Pedestal pattern) white with 'P' trap complete including plastic seat cover white closed pattern with flat bottom, and cover with plastic hinges complete all as specified and directed by Engr-in-Charge.
S&F in repairs factory made solid PVC moulded door shutter 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated wood grains PVC sheet on the front face and 2mm plain colour PVC sheet on back face, provided with 02 Nos 150mm handle, 01 No 250mm long sliding door bolt and 02 Nos 150mm tower bolt to each shutter at site complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50 mm x47 mm made out of 5mm wood grain printed PVC sheet and edges will be painted to match with printed sheets reinforced with MS square tube, supplying and fixing in opening as per specification including fixing of fittings like hinges, holdfast etc complete all as specified and directed by Engr-in-Charge.
S & F in repairs health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mrtre long flexible tube and ABS wall hook, fixed in position complete all as specified and directed by Engr-in-Charge.
S & F in repairs chromium plated shower roses 125 mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engr-in-Charge.
S& fix in repairs tubular towel rail Brass chromium plated, 20mm dia, D type, 60cm long between flanges long complete all as specified and directed by Engr-in-Charge.
S & F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engr-in-Charge.
S&F in repairs vitreous china wash basin, white flat back, counter type, size 550 X 400 mm excluding taps, fixed to wall by anchor bolts, waste coupling, waste pipe etc complete all as specified and directed by Engr-in-Charge.
S & F 32 mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed by Engr-in-Charge.
S & F in repair pillar taps of 15 mm bore dia, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
S & F in repairs Wall Hung flushing Cistern Cat No WHC-WHT-184NL of Jaquar Make with 39 mm drainage L-Bend pipe with gasket and installation kit (suitable for EWC) complete all as specified and directed by Engr-in-Charge.
Taking down existing water proofing treatment of any thickness from the roof /parapet including cement mortar bedding, PCC tiles, padding concrete if any, upto the RCC slab, removing debris off the premises and cleaning the roof complete all as specified and directed by Engr-in-Charge.
Cutting the V grooves on the terrace slab where ever cracks are observed and fill the grooves with Fosrocs heavy duty non shrink grout Convextra GP2, coving all the 90 degree angles, slab/wall junctions with Conbextra GP2 all as per manufacturer's instruction complete all as specified and directed by Engr-in-Charge.
M&L for providing a levelling course of cement concrete type B-0, 1:2:4, using 12.50 mm stone aggregate, 40 mm thick maintains a slope towards the drain water pipes by adding a water proof admixture @ 250 ml per bag of cement complete all as specified and directed by Engr-in-Charge. Note :-Admixture shall be measured and paid seperately.
M&L for rendering with CM 1:3, 10 mm thick mixed with water proofing admixture of Fosroc/Pidilite or equivalent complete all as specified and directed by Engr-in-Charge. Note :-Admixture shall be measured and paid seperately.
Providing and applying one coat of primer of Bostik Boscocem SBR at 0.25-0.30 kg/m2 on a well-prepared surface. Once primer is fully dry apply one-component fast setting UV resistance water based polyurethane waterproofing membrane system of Bostik Block P530 BOSCOSEAL PU-D applied by brush or roller using approximately 2-2.2 kg/m² in two coats to achieve a dry film thickness of 1mm. Waterproofing membrane system continued to be applied on the parapet wall to full height, over the coping area and then terminated on the exterior surface upto 100mm below including Fiber Mesh Reinforcement of 30-60 gsm embedded between the coats. All the concrete/masonry pedestals constructed for supporting the water tanks, dish antenna, water pipelines etc must have done with coving using polymer modified mortar and must be pre-treated with 1mm thick coating of Bostik Block P530 BOSCOSEAL PU-D extending at least 50mm on both the sides all complete as per manufacturers specification. The cured PU waterproofing membrane of BLOCK P530 BOSCOSEAL PU-D must meet the following parameters: Elongation : >300% as per ASTM D412, Tensile Strength : >2 MPa as per ASTM D412, Solid Content >70%, Crack Bridging >3mm as per ASTM C1305, Water Permeability-NIL at 5Bar as per BS EN 12390, Shore A Hardness >75 as per ASTM D2240, Accelarated weathering >2000 as per ASTM G154, Reation to fire - Non-flammable, Solar reflective Index Value-white >100 as per ASTM E1980 complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing admixture complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of brick work/block masonry built in cement mortar complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks in PCC 1:3:6, type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4 with minimum compressive strength of 4N/ sqmm complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks in PCC 1:2:4, type B1 (using 20 mm stone agg) 10 cm in width and setting in mortar 1:4 with minimum compressive strength of 4N/ sqmm complete all as specified and directed.
M&L TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L TMT bars 6 to 8mm dia as in stirrups, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for flat surfaces and making the surface fair finished complete all as specified and directed by Engineer-in-Charge.
M & L for RCC nominal mix 1:1.5:3, type B1 using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 metre span and chajjas complete all as specified and directed by Engr-in-Charge.
M & L for RCC nominal mix 1:1.5:3, type B1 using 20mm graded stone aggregate as in slabs supported on walls, beams, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) in plinth protection, finished even and fair surfaces complete all as specified and directed.
M&L for forming contracton (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade 'A' complete all as specified and directed by Engr-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing unserviceable materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable main switch/DB, teak wood boards, etc complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminium submain wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring concealed type complete with 1100 volts grade 1.5 sqmm (FRLS) PVC insulated, unsheated single core multistranded copper conductor cable including 1.5 sqmm PVC insulated unsheated multistranded copper conductor cable as earth continuity conductor drawn through in and including PVC conduit of suitable size with all accessories including modular inner and outer cover plate and modular GI box made of 1.6 mm thick for fixing modular switches/bell push/socket/regulators, etc including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for one light point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 92 here-in-before but for one fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 92 here-in-before but for one 3 pin socket, 05 Amps on same board with other switches complete all as specified and directed by Engr-in-Charge.
All as per srl item No 92 here-in-before but for one 3 pin socket outlet, 05 Amps on independent board complete all as specified and directed by Engr-in-Charge.
All as per srl item No 92 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 Amp socket complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring surface type with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawn in and including ISI marked PVC casing caping not less than 20 mm width with its accessories, incl modular inner and outer cover plate and modular GI box made of 1.6 mm thick for fixing modular switches/bell push/socket/regulators, etc including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 complete for flushing the modular boxes for one light point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 97 here-in-before but for one fan/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 97 here-in-before but for one 3 pin socket outlet, 05 Amps on independent board complete all as specified and directed by Engr-in-Charge.
All as per srl item No 97 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 Amp socket complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch one way, 10 Amps, single pole, 230 volts, modular type of approved colour complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch one way, 16 Amps, single pole, 230 volts, modular type of approved colour complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket outlet 6 Amps 3 pin combined modular type of approved colour complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket outlet, 6/16 Amps 2/3 pin combined modular type of approved colour complete all as specified and directed by Engr-in-Charge.
Supply and fixing step fan regulator high speed (2 module) 230 volts, 120 Watt complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling rose surface bakelite, 65x50mm, two to three terminals complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DB,s when MCB's to be used, single pole and neutral, double door, 8 way, 240 volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DB,s when MCB's to be used, single pole and neutral, double door, 4 way, 240 volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure for DB,s when MCB's to be used, triple pole and neutral, double door, 4 way, 415 volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB single pole, 240 volts, 6 to 32 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB single pole and neutral, 240 volts, 40 to 63 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB triple pole and neutral, 415 volts, 63 to 100 Amps complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring concealed type with 2 runs of single core 6 sqmm size PVC insulated unsheathed cable 1100 volt grade multistranded copper conductor drawn through and including PVC conduit and its accessories including provision of one runs 6 sqmm PVC insulated unsheathed single core multistranded copper conductor as earth continuity wire including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 complete all as specified and directed by Engr-in-Charge. Note : (1) Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring surface type with 2 runs of single core 4 sqmm size PVC insulated unsheathed cable 1100 volt grade multistranded copper conductor drawn through and including PVC conduit and its accessories including provision of one runs 4 sqmm PVC insulated unsheathed single core multistranded copper conductor as earth continuity wire complete all as specified and directed by Engr-in-Charge. Note : (1) Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Taking down existing tube light fittings from any height and refix the same after carry out necessary wiring work on wall/roof complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED batten fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete with necessary electric connection through suitable size flexible wire complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed by Engr-in-Charge.
Taking down existing wall mounting fans any size/type and deposit the same to store for further disposal action complete all as specified and directed by Engr-in-Charge.
Supply & fix Heavy duty Air Circulator fans 230 volts single phase oscillating 450 mm sweep, push button three speed control suitable for wall mounting complete all as specified and directed by Engr-in-Charge. Make : Almonard or eqvivalent as approved by GE.
Taking down existing exhaust fans any size/type and deposit the same to store for further disposal action complete all as specified and directed by Engr-in-Charge.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep metal body with louver complete all as specified and directed by Engr-in-Charge.
Making hole of suitable size for fixing exhaust fan of size 300 mm on the wall and grouting including plastering complete all as specified and directed by Engr-in-Charge.
M&L for opening, cutting and taking out complete winding coils of ceiling fan of 1200mm sweep of any make, rewinding the same with super enameled copper winding wire as per original pattern including varnishing complete and assembly after oiling/greasing and replacing the worn out nuts, bolts and washers testing the ceiling fan on load for two hours complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised iron or steel plate earth electrode of size 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the plate not less than 1.5 meter below ground level, earth plate shalll be surrounded on all sides with 15 cm thick layers charcoal dust mixed with salt connected to and including galvanised earth strip 32x 6 mm as earthing lead by means of GI nuts, bolts and washers at one end and other end shall be connected to test point complete all as shown on electric plate No 3 of SSR Part I (2009) including excavation and earth work in any type of soil, PCC pit (1:2:4), RCC earth pit cover and suitable handle, 20mm bore GI medium grade watering pipe with wire mesh and funnel, 40mm bore GI medium grade protection pipe including testing on completion complete all as specified and directed by Engr-in-Charge.
Taking down existing turbo ventilator of any size/type and deposit the same to store for further disposal action complete all as specified and directed by Engr-in-Charge.
Supply install testing and commissioning of roof top mounted air operated turbo ventillator fully stainless steel body, incl base plate of suitable thickness, turbo fan with not less than 42 fins incl making necessary provisions in existing roof top without causing any damages, fixing of ventillator with all necessary accessories, making all necessay leak proofing arangements complete all as specified and directed by Engr-in-Charge.
Supply and install 600x600mm size GI powder coated louver grill suitable for above turbo ventillator mounted on false ceiling incl taking down old one complete all as specified and directed by Engr-in-Charge.
Supply, lay, test and commissioning of LT UG cable XLPE insulated sheathed and armoured, with aluminium stranded conductor, LT 1100 Volts grade of size 35 sqmm 3.5 core incl taking down old cables complete all as specified and directed by Engr-in-Charge. Note: Earth work, sand and bricks will be measured and paid under relevant items.
Excavation in trenches for under ground cable n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/ loose soil including forming bottom surfaces to required level complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for riddle sand cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180mm thickness complete all as specified and directed by the Engineer-in-charge. Note:- Punned thickness only shall be measured for the purpose of payment.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed by the Engineer-in-charge.
Supply & Fix GI pipe light grade 80 mm for cable protection under road/floor or fixed to wall/panel incl taking down old GI pipes complete all as specified and directed by the Engineer-in-charge.
M&L for cutting/dismantling of bitumin road/RCC floor etc for laying / passing under ground cables up to 30cm depth complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate 100mm thick in cutted/dismantled portion of road and making good after laying/passing the cables complete all as specified and directed by Engr-in-Charge.
Taking down old GI/Aluminium strip any size with connecting accessories like insulator, screws etc and refix the same after necessary repair work on roof/wall etc complete all as specified and directed by Engr-in-Charge.
Supply and fix air termination, single pointed, aluminium rod 12 mm dia and 300 mm long including taking down old one complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground incl taking down old one complete all as specified and directed by Engr-in-Charge.
WELTRONENGINEERINGSERVICES (BID ID -3064662)
Anaswara Constructions (BID ID -3065035)
SOORYA ASSOCIATES (BID ID -3063380)
JESWIN BUILDERS (BID ID -3072942)
THOMSONS CONSTRUCTIONS (BID ID -3072898)
LAKSHMI BUILDERS (BID ID -3065336)
PRC ENTERPRISES (BID ID -3064719)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .