| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹26 L+₹50,000 (1.96%)Rejected-AOC WARD NO 6 KOKRAJHAR BAZAR ROAD P O DIST KOKRAJHAR BTC ASSAM | DHUBRI | ASSAM | 783331 | L2 | Rejected-AOC Not Awarded | |
| 3 | L3₹26.0 L+₹52,463.02 (2.06%)Rejected-AOC R N B ROAD KOKRAJHAR 783370 | KOKRAJHAR | ASSAM | 783370 | L3 | Rejected-AOC Not Awarded |
| Sl No | Description | Qty | Unit | Kamal Singh Dugar L3 | Bajrang Bhadani L2 | ASSAM ELECTRIC STORE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Civil Work
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.
2.8.1 All kinds of soil. | 17.22 | Cum | 265 ₹4,563.3 | 262.6 ₹4,521.97 | 260 ₹4,477.2 Lowest |
| 2.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 14.23 | Cum | 2,165 ₹30,807.95 | 2,181.6 ₹31,044.17 | 2,160 ₹30,736.8 Lowest |
| 3.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level :
4.1.5 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). | 25.12 | Cum | 6,836 ₹1,71,720.32 | 6,898.3 ₹1,73,285.3 | 6,830 ₹1,71,569.6 Lowest |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level :
4.1.8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). | 0.99 | Cum | 6,335 ₹6,271.65 | 6,393.3 ₹6,329.37 | 6,330 ₹6,266.7 Lowest |
| 5.00 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 51.68 | Sqm | 605 ₹31,266.4 | 606 ₹31,318.08 | 600 ₹31,008 Lowest |
| 6.00 | Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. | 21.06 | Sqm | 375 ₹7,897.5 | 373.7 ₹7,870.12 | 370 ₹7,792.2 Lowest |
| 7.00 | Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 46.33 | Sqm | 613 ₹28,400.29 | 616.1 ₹28,543.91 | 610 ₹28,261.3 Lowest |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level :
5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). | 8.7 | Cum | 8,372 ₹72,836.4 | 8,453.7 ₹73,547.19 | 8,370 ₹72,819 Lowest |
| 9.00 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources). | 14.58 | Sqm | 376 ₹5,482.08 | 373.7 ₹5,448.55 | 370 ₹5,394.6 Lowest |
| 10.00 | Providing and laying cement in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.
4.4.1 1:1 1/2 3 (1 cement 1 1/2 coarse sand (zone-III) derived from natural sources). | 0.16 | Cum | 7,785 ₹1,245.6 | 7,857.8 ₹1,257.25 | 7,780 ₹1,244.8 Lowest |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
12 Aug 2025, 1:00 pmClosed
Superint. Engineer,PWD,Kokrajhar Building Circle
O/o S.E., PWD, Kokrajhar Building Circle, Kokrajhar
Repairing and Renovation of Office Building of the PWD Kokrajhar Electrical Division and Sub-Division PWD IB Complex, Kokrajhar.
2025_BoTC_46052_1
TECH-05/SE(B)/21-22/Pt-III/36
Open Tender
Civil Works - Building
Item Rate
180 days
Kokrajhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
₹51,000
Yes
19 Aug 2025
31 Jul 2025
12 Aug 2025
31 Jul 2025
12 Aug 2025
31 Jul 2025
31 Jul 2025 - 7 Aug 2025
Amount
Civil Work Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 4.1.5 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 4.1.8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
Providing and laying cement in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 4.4.1 1:1 1/2 3 (1 cement 1 1/2 coarse sand (zone-III) derived from natural sources).
62mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix:2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement slurry, but excluding the cost of nosing of steps etc.complete.
Cement plaster skirting up to 30cm height with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of near cement 11.6.1 18mm thick
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.19 Weather shade, Chajjas, corbels etc. including edges
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 5.1.2. 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources:3 graded stone aggregate 20mm niminal size derived from natural sources).
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.A Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and medium tensile steel bars
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and medium tensile steel bars
Half brick mansonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level. 6.12.1 Cement mortar 1:4 (1 cement: 4 coarse sand).
Half brick mansonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level. cement mortar 1:4 (1 cement: 4 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length). Sal wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length.(hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for seprately). Second class teak wood
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architechtural drawing and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): For shutter of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasmet required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35mm thick including ISI marked stainless steel butt hinges with necessary screws.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary, excluding panelling whick will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 9.5.1 1 35mm thick shutters
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. 250x16mm
Providing and fixing aluminium towe bolts, ISI maeked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. comple. 200x10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 100mm
Providing and fixing bright finished brass tower (barrel type) with necessary screws etc. complete: 9.74.1 250x10mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 9.75.1 300x16x5mm
Providing and fixing bright finished brass handles with screws etc. comple: 9.81.1 125mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete:
Providing and fixing PVC Door frame of size 50x47mm with a wall thickness of 5mm (+0.2mm) made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 Nos of PVC bracket of size 190mm x 100mm long arms of cross section size 35x15mm & self driven self taping screws, the vertical door profile to be reinforced with 40x20mm M.S. rectangular tube of 0.8mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x 100mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in-charge.
35mm thick factory made solid panel PVC Door shutter, made out of single piece extruded solid PVC profiles, 5mm (+0.2mm) thick, having styles & rails (except lock rail) of size 95mm x 35mm x 5mm, out of which 75mm shall be flat and 20mm shall be tapered (on both side) having one side thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40mm x 20mm x 1mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190mm x 100mm of cross extruded 5mm thick solid PVC Lock rail of size 115mm x 35mm, out of which 75mm to be flat and 20mm to be tapered at both ends, having 15mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125mm x 11mm, including providing 5mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge. 9.142.1 Non decorative finish (matt finish)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5mm, joints mitred and welded by angle iron 35x35x5mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel, primer, all complete as per the direction of Engineer-in-charge.
15mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement : 4 fine sand).
15mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:6 (1 cement : 6 fine sand).
15mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 fine sand).
Cement plaster 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 13.9.1 12mm cement plaster
12mm cement plaster of mix: 13.4.1 1:4 (1 cement: 4 coarse sand) i) For Building-Inside wall
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: 13.43.1 Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10sqm
Applying Priming coat: 13.50.1 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). D (Bothside)
Painting with oil type wood preservative of approved brand and manufacture: 13.57.1 New work (two or more coats)
With ready mixed red oxide zinc chromate primer of approved brand and manfucture on steel galvanised iron/steel works
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr/10 sqm
Painting wood work with Deluxe Multi surface paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture.
Painting Steel work Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Providing corrugated G.S. Sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. Limpet washers or with G.L. Limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.60mm thick with zinc coating not less than 275gm/m2
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shade wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: 12.51.1 Ridges plain (500-600mm)
Providing ridges or hips of width 60cm overall width plain G.S. Sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I. Limpet and bitumen washers complete. 12.4.1 0.60mm thick with zinc coating not less than 275gm/m2
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
Providing and fixing 15mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main "T" runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33 thick (minimum) sheet, spaced 1200mm centre to centre and cross "T" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main "T" at 600mm centre to centre to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 24x28mm made of 0.33mm thick (Minium) sheet to be inter locked at middle of the 1200x600mm panel to from grid of size 600x600mm, resting on periphery walls/partion on a Perimeter wall angle pre-coated steel of size (24x24x 3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/making opening for services like diffusers, grills, light fittings, smoke detectors etc., wherever required. Main "T" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanised steel level clips of side 85x30x0.8mm, spaced at 1200mm centre to centre along main "T" bottom exposed with 24 12.5mm thick tapered edge Gypsum moisture resistant board.
Providing and fixing plain multipurpose cement board (Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid separately). 6mm thick cement fiber board as per IS:14862
Providing and laying ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make, in all colours, shades, except white, Ivory, Grey, Fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigments etc. complete Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades, except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry@ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. Flush bend with fittings & C.I. Brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. Brackets 15mm C.P. Brass pillar taps, 32mm C.P. Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450mm with a pair of 15mm C.P. brass pillar taps
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. 17.28.2.1 Flexible pipe 32mm dia
Providing and fixing soil, waste and vent pipes: 17.35.1 100mm dia 17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architechtural drawing and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): 21.1.1 For fixed portion Anodised aluminium (anodised transparent to required shade according to IS:1868, Minium anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherevr required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, minimum anodic coating of grade AC 15).
Providing and fixing 100mm diameter and 60cm long rain water spout in cement mortar 1:4 (1 cement: 4 fine sand). 12.37.1 Stone ware spout
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. 18.7.2 20mm nominal dia pipes.
Providing and fixing brass bib cock of approved quality: 18.15.2 20mm nominal bore
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Boundary Wall Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 4.1.8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size).
Steel reinforcement for RCC work including straightening, cutting, bending to proper shape plaing in position and binding upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Posts and Strut.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 5.1.3 1:2:4 (1 cement: 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level. 6.13.1 Cement mortar 1:4 (1 cement: 4 coarse sand).
15mm thick cement plaster in single coat on rough side of single or half brick wall. 13.5.1 1:4 (1 Cement : 4 coarse sand).
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: 13.43.1 Water thinnable cement primer
Finishing walls with water proofing cement paint of approved brand and manufacture of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10sqm
Approach Road Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil.
Construction of granular sub-base by providing close graded material conforming to specification, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specification thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-charge.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Cement concrete 1:2:4 (1 cement: 2 coarse sand) : 4 graded stone aggregate 40mm nominal size) in pavements laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
ELECTRICAL WORKS Wiring for light/fan/Exhaust fan point/Call bell point with 1.5 sq mm FRLS PVC insulated copper Conductor single core cable in surface/recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc, as required. 1.8.1 Group A
1.8.2 Group B
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit as required. 1.17.2 2 x 1.5 sq.mm
1.17.20 2 x 4 sq.mm
1.17.29 2 x 6 sq.mm
Supplying and fixing following piano type switch/socket on the existing switch box cover including connections etc. as required. 1.23.4 3 pin 5/6 Amp socket outlet
1.23.8 Bell Push
Supplying and fitting Brass batten/angle holder including connection etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase 230V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet MCB Distribution board, 240 V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections powder painted including earthing etc. as required. 2.3.1 6 way Double door
Supplying and fixing 5 Amp to 32 Amp rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as rquired. 2.10.1 Single pole
Supplying and fixing following rating, double pole 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 Amp.
Earthing with G.I. earth pipe 4.5 Metre long, 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with G.I. thinnble etc. as required.
Supplying with including fitting & Fixing of ceiling fan 1200mm (Havells make) including Regulator, Down rod etc. as required and directed by the deptt.
Supplying with including fitting & fixing of LED Tube Light-20 watt. Complete set (Bajaj) Make. As required and as directed by the deptt.
Supplying with inclduing fitting & fixing of LED Bulb-20 watt. (Philips) make as required and as directed by the deptt.
Bajrang Bhadani (BID ID -275405)
Kamal Singh Dugar (BID ID -274955)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .