Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC | ₹2.2 Cr Quoted ₹2.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.4 Cr+₹11.0 L (4.90%)Rejected-Finance | ₹2.4 Cr+₹11.0 L (4.90%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹2.4 Cr+₹15.8 L (7.02%)Rejected-Finance NOT SPECIFIED | ₹2.4 Cr+₹15.8 L (7.02%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹2.5 Cr+₹24.4 L (10.8%)Rejected-Finance | ₹2.5 Cr+₹24.4 L (10.8%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹2.5 Cr+₹27.9 L (12.4%)Rejected-Finance | ₹2.5 Cr+₹27.9 L (12.4%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
6 Jan 2020, 6:00 pmClosed
Brig Mukund Sharma
CE FY HYDERABAD SECUNDERABAD
REPLACEMENT OF EXISTING AC SHEETS WITH GALVALUME SHEETS IN STORES BLDGS 05 NOS BLDG NOS 19/01 19/2 19/03 19/04 AND 19/05 INCLUDING GAS HOUSE BLDG NO 17 INSIDE FACTORY AREA AT OF MEDAK
2019_MES_300126_1
820291/MDK/E8
Open Tender
Construction Works
Item Rate
450 days
Eddumailaram
As per Tender and NIT
7 documents required · 7 mandatory
₹2,000
Asst Garrison Engineer (I) Fy Eddumailaram
₹3.9 L
Yes
7 Feb 2020
22 Nov 2019
10 Jan 2020
22 Nov 2019
6 Jan 2020
28 Dec 2019
23 Nov 2019 - 27 Dec 2019
Amount
Dismantling of wrought iron or mild steel work of windtie of any description not otherwise provided for complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets but from wall cladding, vertical sheets and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified and as directed.
Demolition of brickwork / concrete work built in cement mortar in any position complete all as specified and as directed.
S&F for Structural steel supports conforming to FE 410W (Gde E-250) Quality A, for roof trusses (framed), trussed, purlins, crane gantries, rails and fasterning and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc. complete all as specified and as directed.
M&L for preparation of steel surfaces area exc 10 cms width or girth and finishing with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F Pre-coated galvalume aluminium zinc coated GI based corrugated roofing sheets (size, shape and pitch of corrugation as approved by Engr-in-Charge 0.50mm total coated thickness (TCT), Zinc aluminium alloy coating AZ 200 as per IS 277 in 550 Mpa Steel grade painted with super durable polyester 18-22 microns on outside, 5-8 micron epoxy primer at Inside of sheet, with protective guard film of 25 microns minimum to avoid scratches while transportation and shall be supplied in single length upto 12 M or as directed by Engineer-in-Charge. The sheet shall be fixed using self drilling/self tapping screws @ minimum 5 Nos per Sqm along the purlins and where ever directed by Engineer-in-Charge with EPDM seal of make CORRO SHIELD/BUILDEX/HILTI or equivalent. All over laps of the roof sheets shall be sealed with one touch fasteners and continuous ribbon of self adhesive roofing tape of size 50 x 3mm (using low hardening butyle rubber) of non asphaltic, non shrinking, non drying and non-toxic and shall have superior adhesion to metals, plastic and painted surface. complete all as specfied and as directed.
S&F Pre-coated galvalume aluminium zinc coated GI based plane roofing sheets (size, shape and pitch as approved by Engr-in-Charge 0.50mm total coated thickness (TCT), Zinc aluminium alloy coating AZ 200 as per IS 277 in 550 Mpa Steel grade painted with super durable polyester 18-22 microns on outside, 5-8 micron epoxy primer at Inside of sheet, with protective guard film of 25 microns minimum to avoid scratches while transportation and shall be supplied in single length upto 12 M or as directed by Engineer-in-Charge. The sheet shall be fixed using self drilling/self tapping screws @ minimum 5 Nos per Sqm along the purlins and where ever directed by Engineer-in-Charge with EPDM seal of make CORRO SHIELD/BUILDEX/HILTI or equivalent. All over laps of the roof sheets shall be sealed with one touch fasteners and continuous ribbon of self adhesive roofing tape of size 50 x 3mm (using low hardening butyle rubber) of non asphaltic, non shrinking, non drying and non-toxic and shall have superior adhesion to metals, plastic and painted surface. complete all as specfied and as directed.
S&F Bands, Straps, supports or stays for rainwater, ventilating pipes valley gutters including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; well tiles; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafter; knee piece inserts: two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screws and washers fixed to highly elevated roof, wall etc. fixed with in roof, wall etc. 'L' type or 'J' type cranked hook bolts in lieu of screws complete all as specified and as directed.
M&L for brickwork using old size sub class 'B' Bricks built in CM 1:6 straight or curved on plan exc 6 mtr mean radius complete all as specified and as directed.
M&L for Rendering 15mm thick on brick work or concrete surfaces in two coats, first coat 10 mm thick in CM (1:6) and second coat with 5mm thick in CM (1:4) mixed with and including water proofing compound @ 2% finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Supply only intergal water proofing compound complete all as specified and as directed.
Taking down cement plaster including raking out joints, hacking for key, scrubing down with water, etc. Complete all as specified and as directed.
M&L for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed.
M&L Preparing, washing rubbing down and stopping of painted old surface of plastered surfaces and apply one coat of white wash complete all as specified and as directed by Engineer-in-Charge.
M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surface complete all as specified and as directed.
M&L for APP based polymetic membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. Not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed by Engineer-in-Charge.
Dismantling of CI Pipes of 150mm dia (any size or pattern) including all fittings complete all as specified and as directed.
S&F Cast Iron rainwater socketed pipes of Dia 150mm with cement joints, without ears complete all as specified and as directed.
S&F Cast Iron Bends or elbows, square or obtuse for pipes of Dia 150mm complete all as specified and as directed.
S&F Cast Iron shoes for pipes of Dia 150mm complete all as specified and as directed.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cm x 8cm at the junction of roofing to vertical surfaces, Fibre glass reinforced translucent corrugated sheet with galvalume sheet incoudlg cutting chases if any in brick wall etc. complete all as specified and as directed.
M&L for running welding metal in repairs not exceeding 6mm thick complete all as specified and as directed.
M&L for preparation of new steel surfaces, not exceeding 10 cm width or girth and finishing with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed.
Supply & installation, testing and commissioning of wind driven roof turbo ventilators of complete Aluminium structure with variable pitch base to counter roof slope angle upto min 20 degrees and suitable for exhaust capacity not less than 1498 CFM at wind speed of 5 MPH and of ventilation size 24 inches comprising the following: - a) Turbine dia - Min 730mm b) Neck/throat - Min 600mm c) Vanes - 42 vanes, AI 05mm, thickness alloy 8011 d) Centre shaft - 17mm stainless steel e) Rotation bearing - Twin ZZ ball bearings permanently lubricated & sealed f) FRP transparent base plate - 2mm thick matching sheet profile (are min 1m2) Note: Rate quoted for the same deemed to be inclusive of misc items, materials required for making good of the disturbed surface in the unit rate.
M&L for Air termination single pointed aluminium rod, 12mm dia, 300mm long complete all as specified and as directed.
M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed.
M&L Galvanized iron strip 32x6mm buried in ground complete all as specified and as directed.
M&L for Test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 03 Nos, 8mm dia 25mm long hex head screw and covered with sheet metal Box of proper size complete all as specified and as directed.
M&L for steel water tubing, 40mm bore dia, light grade galvanized with all fittings, laid in trenches for earth strip protection complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized steel earth strips of size 32 x 6mm by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No.3 connected to earthing test point including testing on complete all as specified and as directed. Note: The unit rate quoted shall be include for necessary excavation and earth work in any type of soil, earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit, CI cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 40mm dia for supporting of earth strip. The earthing value of each earthing pit to be below 10 Ω (Ohm).
Demolition concrete in floors not exceeding 15cm thickness below and above ground level complete all as specified and as directed.
M&L Cement concrete of type B2, 1:2:4 using 40mm graded aggregate complete all as specified and as directed.
M&L Preparing new plastered surface and apply two coat cement base paint over priming coat with alkali resistant priming paint on wall complete all as specified and as directed by Engineer-in-Charge.
Nexus Infratech
United Sales Corporation
R.R.FOUNDATION
RMK PROJECTS
Rajan Traders
pal construction
GAGANSRI INFRA
M/s Amit Associates
Mavee Syndicate
Sai Ram Builders
Indus Projects Private Limited
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .