Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 54 10 C JAI DEVI NAGAR MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹29.1 L Quoted ₹29.9 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹31.2 L+₹1.3 L (4.29%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹31.2 L+₹1.3 L (4.29%) | L2 | Rejected-AOC NOT LOWEST |
| 3 | L3₹33.6 L+₹3.7 L (12.4%)Rejected-AOC | ₹33.6 L+₹3.7 L (12.4%) | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Oct 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
REPAIR TO LEAKAGE SEAPAGE WATER PROOFING TREATEMENT RCC CHAJJA FACIA ROOFING CEILING AND MISC B R ITEMS AT MIL STN RAIWALA
2021_MES_475720_1
86327/RWL/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Raiwala
Class D Cat a i
6 documents required · 6 mandatory
₹500
Yes
AGE(I) Raiwala
₹70,000
Yes
28 Oct 2021
16 Sept 2021
14 Oct 2021
16 Sept 2021
12 Oct 2021
28 Sept 2021
16 Sept 2021 - 20 Sept 2021
Amount
Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed with polymer modified repair mortar (SBR Latex liquid polymer as per manufacturer direction ) and finishing the surface even and smooth using extra cement as in roof padding treatement to receive roof treatment complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately..
Supply only SBR Latex liquid polymer of approved make ISI Marked complete all as specified and directed.
M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :- (a) Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3 .6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
M&L of water proofing treatment to non-accessible roof slab with water proofing liquid membrane as per manufacturer’s instructions with following course of description below :- (a) Application of one coat of Epoxy Primer in ratio of 1:3 (Resin : Hardener) on the cleaned surface for bonding of liquid membrane with the existing concrete surface. (b) Application of two coat of High build elastomeric waterproofing coating of two component hybrid Polyurea polyurethane applied as a waterproofing liquid membrane. (f) After the complete application of treatment, the treated area will be tested for water tightness by ponding with water 72 Hours for any seepage, if observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaired, the slab will be tested for water tightness again Note : 1. The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer only 2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
M/L for PCC 1:2:4 type B-0 (Using 12.5mm stone aggregate) mixed with SBR Latex liquid polymer (mixed as per manufactur direction) as in concrete angle-fillets with a radiaus of 75 mm at junction between roofs/chajja/top surface of projected cub boards and vertical faces of wall ( parapet and other walls) to ease up about corners and over chhajjas and like incl using form work (straight or curved ) as required complete all as specified and directed . Note - The work is required to be carried out up to double storey . The contractor shall make arrangement of scoffolding,safety & security of workers. The rates quoted shall deemed to be included for these items .
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings.
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall and gutter, fixed with self tapping screws complete all as specified and directed .
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings
S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with coach screws and washers, in roof walls etc with grade of zinc coating 275. complete all as specified and directed .
All as per item No. 12 above item but except sheet. complete all as specified and directed .
S&F 0.63 mm thick plain galvanised black mild steel sheeting in reidges, hips, valley gutters, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275. complete all as specified and directed .
M&L Preparation of new zinc or galvanised surface to receive painting,by coating with modrant solution including washing ,cleaning etc and applying two coats of synthetic enamel paint complete all as specified.
M&L Preparation of previously untreated surface of zinc or galvanised surface to receive painting,by coating with modrant solution including washing ,cleaning etc and applying two coats of synthetic enamel paint complete all as specified.
Dismantling mild steel work of any description not otherwise provided for. complete all as specified and directed .
S & F Rolled Mild Steel sections confirming to Fe 410 - W as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates. complete all as specified and directed .
S & F Mild steel work in hand rails, wind ties, as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O. complete all as specified and directed .
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.complete all as specified and directed .
M&L preparation of old painted steel surfaces of any descripton over 10cm width or girth and applying one coat of synthetic enamel paint First quality all as specified and directed .complete all as specified and directed .
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6. complete all as specified and directed .
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work. complete all as specified and directed .
Taking down cement plaster in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L Rendering 15 mm thick in CM 1:4 over and including a one coat of cement slurry admixed with SBR latex liquid primer on brick / concrete surface, and downward facia mixed with polymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction ) . Note - (SBR) Latex liquid polymer will be measured and paid seperately.. Note :- The work is required to be carried out upto double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach up torequired height . The rates quoted shall deemed to be included for these items .
M&L for Rendering 15 mm thick on fair faces of brick work or concrete walls surfaces in CM 1:6 finished to even & smooth without using extra cement.complete all as specified and directed .
M&L for preparation of surfaces of new plaster surface of wall and applying two coat of cement base paint over a coat of alkali resitant prime complete all as specified and directed.
Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs . complete all as specified and directed .
S&F Rotational moulded polyethylene water storage tank 1000 liters capacity, white triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including all fittings complete all as specified and as directed.
Disconnecting existing tanks 500 but n. exc 1000 ltrs, setting aside (or lowering if required) for repairs etc required reconnecting and re-fixing in position with all sutiable fitting. complete all as specified and directed .
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .complete all as specified and directed .
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M & L for for shifting aside of MS monkey case of any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site and as directed by Engr-in-Charge
Taking down roof trusses, coupled rafters or trussed beams trusses above 4 mtr & upto 8 mtr etc,for renewal of any defective members (timber renewed to be measured separately) and reassembling including Housing and fixing trusses etc. after repairs including tightening up wedges, cotters bolts etc.complete all as specified and directed .
Dismantling Unframed timber scantlings 40 Sq. cm and over in section and in any position. complete all as specified and directed .
M&L 2nd class hard wood (Sal) in scantling wrought timber framed and fixed. complete all as specified and directed .
M&L preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with one coats of creosote oil. complete all as specified and directed .
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets.complete all as specified and directed .
S&F false ceiling 4 mm thick with GI framed work with main tee of size 24X28.5 mm made out of PGI sheet 0.3 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and wall angle 24X24X0.45 mm powder coated for celing , ceiling board 60cmX60cmX4.0 mm thick , suspended with GI wire 2 mm dia & upto 2 M average length with adjustable device complete including plugging in brick /stone wall with steel rawal plugs@ 600 mm C/C . Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and painted with two coats of Acrylic distemper tint as approved by GE/AGE including making good all the disturbed portion , complete all as specified and directed.
S&F in repair , 4 mm thick false ceiling board of any size and placed to the framed work with staple clips at all four sides.complete all as specified and directed .
S & F in repairs 110 mm bore PVC (SWR) Soil pipe (ISI Marked) , waste and vent pipes single socketed in any length with rubber ring joints fixed to walls.complete all as specified and directed .
S & F in repairs 110 mm bore PVC (SWR) bends of any radius (ISI Marked) . complete all as specified and directed .
S&F in repair stack clamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stamp including bolts and nuts and securing ends of stays to walls or roof for 100 mm pipe, complete all as specified and directed.
TARUN ENGINEERING WORKS
P K ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .