Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹9.1 L+₹50,016.96 (5.83%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹10.5 L+₹1.9 L (22.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹12.2 L+₹3.7 L (42.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagroan Bridge Ludhiana-141001
REPAIR AND COMPREHENSIVE MAINT TO LT ELECTRIC SUPPLY, PANELS AND ALLIED ITEMS OF WORK AT CG COMPLEX DORAHA AND PHILLOUR UNDER GE LUDHIANA
2022_MES_552696_2
GE/LDH-45/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CG Complex Doraha and Phillaur
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,000
Yes
29 Nov 2022
19 Oct 2022
9 Nov 2022
19 Oct 2022
8 Nov 2022
26 Oct 2022
19 Oct 2022 - 25 Oct 2022
Amount
Dismandling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT pole/ Lines all as specified and directed by Engr - in - Charge.
Dismandling of existing unserviceable cross arms of any description and in any position complete all as specified and directed by Engr - in - Charge.
Dismandling & taking down of existing worn out / unserviceable GI wire of any description /size & in any position from existing LT Lines including cradle guard/ earth continuty wires complete all as specified and directed by Engr - in - Charge.
Dismandling of existing unserviceable Insulators of any description and in any position complete all as specified and directed by Engr - in - Charge.
Dismandling of existing unserviceable cemented concrete poles/ struts of any Size and in any position complete all as specified and directed by Engr - in - Charge.
Dismandling of existing unserviceable stay assembly of any Size and in any position complete all as specified and directed by Engr - in - Charge.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed by Engr - in - Charge.
M & L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in the foundation of electric poles,stay assembly and struts PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed by Engr - in - Charge.
All as per srl No Item No- 8 here-in-before but PCC (1:2:4) type B-1 using 20mm graded stone aggregate for coping of poles complete all as specified and directed by Engr - in - Charge.
Supply and erecting pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978 including disconnecting and reconnecting ACSR conductor, painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed by Engr - in - Charge. (PCC for foundation and earth work shall be measured and paid for separately).
M& L in replacement for cross arms, bracings, supports clamps and back plate fabricated from steel structural including nuts,bolts washers welding,bending cold or hot,drilling holes and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr - in - Charge.
M & L for loop type insulator, porcelain vetrieous white or brown, with overall dimensions of 65mm x 90mm, clearance of hole 16mm complete all as specified and directed by Engr - in - Charge.
M& L for pin type porcelain vitreous, white, brown or green insulators inclding one galvanized mild steel spindle two galvanized iron washers and one galvanised iron nuts and 65 mm dia , 100mm herght for 1100 volt grade complete all as specified and directed by Engineer-in-Charge.
M & L for shackle type, porcelain, vitreous, white, brown or green insulator incl galvanised mild steel straps, washers, insulators bolts, washers and nuts complete 100 mm height and 115 mm dia for 1100 volts complete all as specified and directed by Engr - in - Charge.
S & F in replacement ACSR conductor steel, reinforced on over head lines fixed on insulators, binding with and including binding wire 14 swg complete all as specified and directed by Engr - in - Charge. ( for payment purposes, the weight of binding wire shall not be consider )
Supplying and drawing and fixing in replacement of continous GI earth wire/guard cradles 4 mm dia including GI binding wire 1.63mm on LT poles complete all as specified and directed by Engr - in - Charge.
M & L in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long ( over all) galvanised stay rod 16 mm dia 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50 mm x 6 mm flat iron complete including stay wire 7/8 SWG complete all assprcified and directed including necessary excavation and earth work and PCC 1:3:6 all as shown in electrical plat No.1 of SSR-1991 Part-I (PCC and earth work, loop type insulator, stay clamps shall be measured and paid for separately under the respective item of schedule) including taking down existing old unsv stay assembly complete all as specified and directed by Engr-in-Charge.
M & L for danger notice plates made out of 1.6mm thick mild steel sheet, vitreous enamelled white letters, figures, and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down existing old unsv danger notice plate complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing, testing and commissioning in replacement of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old one.
16 Sqmm 4 Core
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
50 Sqmm 3.5 Core
70 Sqmm 3.5 Core
95 Sqmm 3.5 Core
120 Sqmm 3.5 Core
150 Sqmm 3.5 Core
Taking out existing XLPE cable HT/LT any make and any size complete all as specified & directed by Engineer-in-charge.NOTES : (i) Excavation & earth work shall be measured and paid separately.
Laying only, jointing, testing and commissioning of cable XLPE insulated LT/HT,armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs.NOTES : (i) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately.
Excavation in trenches in soft loose of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed by Engr - in - Charge.
Material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed by Engr-in-charge.Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
Supplying and laying of bricks common brunt clay building bricks sub class B incl removing of old bricks complete all as specified and directed by Engr - in - Charge.
Returning, filling in, any type of soil and spreading, in layers not exceeding 25 cm thick complete all as specified and directed by Engr - in - Charge.
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed & complete all as specified and directed by Engr - in - Charge.
Supply and fix of Aluminium Lugs suitable for 16 to 35 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed by Engr - in Charge.
Supply and fix of aluminium Lugs suitable for 70 to 185 Sqmm 1100 Volts including taking down old unserviceable lugs, complete all as specified and directed by Engr - in Charge.
Supply and fixing in replacment GI pipe light grade 50 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified and directed by Engr-in-Charge .
Supply and fixing in replacment GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified and directed by Engr-in-Charge .
M & L for stone aggregate of size 40 mm spreading over and including 100mm(compacted) thick sand layer duly compacted in the sub station areas including proper levelling all as directed by Engr-in-charge.
Material & labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (1:1/2:3) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed by Engr-in-charge. Notes : (i) Outer edge of earth pit will be 1.5m away from the outer edge of PCC chamber. (ii) Water pipe shall be provided in slanting position.
Taking down from MES substation,opening of LT Panel of any type by unscrewing nut,bolts,disconnected all the electrical connection,refix/reassemble the LT panel after repair work as under mentioned including reconnection all electric cables/wires,testing all equipments etc all as specified and directed by Engg-in-charge.
Repairs to broken out/disconnected door of LT Panel/Meter Panel by welding with new hinges including necessary material required for smooth opening and closing of door and fixing the same with the existing panel complete all as specified and directed by EIC.
Supplying and fixing in replacement digital voltmeter (0-500 Volts ) 96x96mm square type including taking out old unserviceable voltmeter complete all as directed by Engineer in charge
Supplying and fixing in replacement digital Amps meter (0-600 Amps ) 96x96mm square type including taking out old unserviceable seperator complete all as directed by Engineer in charge
Material and labour for replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size all as specified by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 400 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable TM type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 315/320 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 250 Amps, 4 pole, 415 volts AC, 25 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 200 Amps, 4 pole, 415 volts AC, 25 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 25 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 125 Amps, 4 pole, 415 volts AC, 25 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB of current rating 100 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge.Make for srl no 34 to 37 :-HPL/Indoasian/Havells/ABB
Supply and fixing in replacement of MCCB of current rating 63 Amps, 4 pole, 415 volts AC, 16 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed by Engr-in-Charge..Make for srl no 34 to 37 :-HPL/Indoasian/Havells/ABB
M&L for painting of panel board of (Area not more than 8 Sq mtr) inner & outer complete with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust/rust including writing the Distribution/Panel Number and panel details all as directed by Engr-in-Charge. Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames complete.
S&F for jointing and testing LT straight through (heat shrinkable) cable end termination joint suitable for LT cable 11000 volts grade 16 Sqmm to 35 Sqmm complete all as specified and as directed by Engr-in-Charge.
S&F for jointing and testing LT straight through (heat shrinkable) cable end termination joint suitable for LT cable 11000 volts grade 50 Sqmm to 150 Sqmm complete all as specified and as directed by Engr-in-Charge.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables. complete all as specified and directed by Engr-in-Charge.
M&L for pinpointing of 11 KV underground LT cable fault of any size with help of cable fault locating (CFL Machine) consisting of DC testing, thumping system and DIGI point sensor complete to locate the exact fault location complete all as specified and directed by Engr-in-Charge.
GULSHAN SINGH GHAI AND SON
PARDEEP CONSTRUCTION COMPANY
shri ram enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .