Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹88.1 LAccepted-AOC D NO 18 13 4 3RD FLOOR HILL CREST APARTMENT SEETHAMADHARA NORTH EXTENSION VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹88.1 L | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹91.5 L+₹3.4 L (3.82%)Rejected-Finance | ₹91.5 L+₹3.4 L (3.82%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹92.9 L+₹4.8 L (5.48%)Rejected-Finance | ₹92.9 L+₹4.8 L (5.48%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹96.8 L+₹8.7 L (9.82%)Rejected-Finance | ₹96.8 L+₹8.7 L (9.82%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹1.0 Cr+₹14.6 L (16.5%)Rejected-Finance | ₹1.0 Cr+₹14.6 L (16.5%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
25 May 2020, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Building No. P - 66 at INS Satavahana, Visakhapatnam
2020_MES_339596_1
82035 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.9 L
Yes
26 Jun 2020
20 Apr 2020
1 Jun 2020
20 Apr 2020
25 May 2020
11 May 2020
20 Apr 2020 - 27 Apr 2020
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring / Levelling course / Padding over roof slabs complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 to 9 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 to 9 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 9 to 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 9 to 10 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L PVC Tiles / Sheets, Laminated Plain Coloured, Marbled Mosaic or Mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for filling Polymer Modified Non Shrinking Slurry using Brush Bond Powder and Nitobond BB Acrylic Emulsion of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Batik India Pvt. Ltd. for Sunken Floors for Toilets by drilling holes at 60cm interval to a depth of 60 mm, 20mm dia and applying slurry all as per manufacturer's instructions complete all as directed.
M & L for 40 mm average thick, PCC 1:2:4, Type B-1, using 20mm graded aggregate as in Sub base for flooring etc. including mixing water proofing compound as per manufacturers instructions and finishing the top surface rough complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area not exceeding 100 Sq.cm complete all as specified and as directed.
S & F in repairs UPVC Pipe of 50 mm bore, of pressure rating 10 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:3, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral Water Proofing Compound [ISI marked] of approved make.
M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves and the like complete all as specified.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed.
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for fair finished surfaces of concrete complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Parapets, Facias & Fins etc. complete all as specified and as directed.
Use and removal of steel formwork to Fins, Louvers, Fascia and similar works etc., vertical or to batter for fair finished surfaces complete all as specified and as directed. sides of concrete
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-1, using 20 mm graded stone aggregate as in Bed blocks and Bed plates including weathering, slightly rounded or chamfered angles and throating, necessary form work etc complete all as specified and directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc. [without Sash Bars], edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed.
S & F Factory made, 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Factory made PVC Ventilator made out of multi chamber PVC hollow section DWUF 405 [40x46mm] with 3mm pin headed glass fixed to the lower section using extruded PVC section of 9 X 19.5mm size OL19 with EPDM gasket [SPL 003] for both PVC sections, ventilator's centre mullion shall be made up of multi chamber hollow PVC section DWUF-406 [63.5mmX40mm] with EPDM gasket GL-19 and fixed to the 3 sides of DWUF-405 and DWUF 406 [63.5X40mm] above the centre mullion, Glass panels with aluminium lower set shall be fixed to the frame DWUF-405 on the top of the ventilator for the glass, DWUF 405 and DWUF 406 comers shall be mitred cut and welded, jointed with 12mm MS Rods [Guard Bars] including necessary fixtures complete all as specified and as directed.
S & F Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or stainless steel wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing 0.55 KG / RM, Grills including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze etc.
Supply only 12mm thick, Prelaminated Particle Board, One Side Decorative Choice Lamination and other side Balancing White, Medium Density, Interior Grade complete all as specified and as directed.
Supply only 4mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only 5mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F 125 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S & F Mild Steel Door Spring 375 mm, Ordinary Rat Rail Rod Pattern springs including roller and roller plate complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F Harrison Rails [Curtain Rails], Anodised Aluminium, 25 mm dia with fixing brackets, stops, rollers etc complete all as specified and as directed.
Forming jambs etc to openings with stone supplied by MES including cutting, toothing and properly bonding in to old work including facing and pointing [if necessary] to match existing work, complete built in Cement Mortar 1:4 complete all as specified and directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 or 32 mm bore of pipe complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. CON-011KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 630 mm X 450 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & F in repairs Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc., grating and union for discharge pipe, CP screws etc. complete all as specified and as directed.
S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as per Jaquar Catalogue No. CON-083KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Single Lever cast copper alloy, chromium plated Hot and Cold 15mm dia Wall Mixer with provision for both Hand Shower and Overhead Shower complete with 115mm long bend pipe, connecting legs & wall flange complete [excluding hand & overhead shower] as per Jaquar Catalogue No. CON-281KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & F in repairs 125mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 2000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
S & F plain Aluminium Sheet Alloy 31000 H4 in Ridges, Hips, Valley Gutter, drip and straight flashing of 0.71 mm thick complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on walls complete all as specified and as directed.
M & L for preparing newly plastered wall / ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls / ceilings complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on walls and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed.
M & L for washing, rubbing down and stopping of distempered and painted surfaces of Wall / Ceiling and applying one coat of Acrylic Washable Distemper on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for washing, rubbing down and stopping of painted surfaces and applying One coat of Plastic Emulsion Paint on on Walls / Ceiling surfaces complete all as specified and as directed.
M & L for preparation of old painted wood and wood based surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 15mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of skirting / dado / risers and joints shall match with the flooring.
S & F Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 316, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
S & F Seamless Calcium Silicate False Ceiling made out of 10mm thick, 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying two or more coats of Cement based Wall Care Putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer and including Frame Work using GI perimeter channels of 0.55 mm thick, having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, fixed to wall with nylon sleeves and screws at 450 mm intervals, GI intermediate channels of size 45 mm X 15 mm X 0.90 mm supported with GI ceiling angles of size 25 mm X 10 mm X 0.55 mm fixed to soffits with steel expansion fasteners / GI cleats at 1220 mm intervals, ceiling section of 0.55 mm thick having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channel with connecting clips and in direction perpendicular to the intermediate channels at 457 mm centre to centre including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 108 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 108 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 108 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 108 above but for one SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket, with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 and including 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 as earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 100 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
S & F CMRI certified Flame proof LED Tube Light Fitting of not less than 2000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, Heat resistant Toughened Glass Cover, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 8 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 4 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs TV Socket / Outlet, Co-Axial, Deluxe, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs LAN Outlet, RJ 45, Modular Type, One Module, including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, TP, 125 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCCB, TP, 250 Amps, 36 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 4 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 6 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 16 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 16 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 3000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 25 X 4mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
Taking down Ceiling Fan / Exhaust Fan / Air Circulator / Wall Mounted Fan etc. of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and spray painting with approved colour after filling cavities with filler complete all as specified and directed.
M & L for repairs to LT Panel Board including rewiring of all electrical connections of LT Panel Board of any description with new Terminal Connector, Lugs and Wire of suitable size after disconnecting, removing the burnt Contactors, Controllers, Transformers, Fuses, Cables and other connecting accessories etc., tinkering the enclosure to proper geometrics, removing all the corroded sheet metal parts like base plate, top plate, front cover etc. with 2.00mm thick CRCA Sheet, bending to match with existing size and shape, welding / brazing, degreasing, phosphatising all the surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and finishing the surface for matt finish after due preparation of surfaces complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
N Sydeswara Rao
CIVILEC ENGINEERING WORKS
VAISHNAVI ASSOCIATES
SRI SIMHADRI COMPANY
Mavee Syndicate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .