Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.6 L+₹3.3 L (10.2%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical DD and Application of M/s Khaira Enterprises uploaded |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
16 Nov 2023, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
CERTAIN REPAIR INTERNAL ELECTRIFICATION INCLUDING GATE LIGHT ETC IN OFFICERS AND TECH AREA AT AF STN HALWARA
2023_MES_618339_2
GE/HAL-36/2023-24
Open Tender
Civil Works
Item Rate
365 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹80,000
Yes
22 Dec 2023
19 Oct 2023
18 Nov 2023
19 Oct 2023
16 Nov 2023
28 Oct 2023
Amount
Taking down aluminium / copper point wiring with surface/ concealed stove enamelled steel/ PVC conduit or wooden batten ( light, fan, socket, or power ) including sunk in cast iron / pressed steel terminal boxes such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls, floors etc complete.
M & L for concealed Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified.
All as per item No. 2 above but for Ceiling Fan, one point controlled by one switch.
All as per item No. 2 above but for Exhaust Fan point, one point controlled by one switch.
All as per item No. 2 above but for socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 2 above but for socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 2 above but for call bell point, one point controlled by one switch.
All as per item No. 2 above but with 4.0 sq mm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
M & L for concealed Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in existing PVC / ERW steel conduit with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified.
All as per item No. 9 above but for Ceiling Fan, one point controlled by one switch.
All as per item No. 9 above but for Exhaust Fan point, one point controlled by one switch.
All as per item No. 9 above but for One socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 9 above but with call bell point, one point controlled by one switch.
All as per item No. 9 above but with 4.0 sq mm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
M & L for Surface Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in surface PVC conduit/ PVC casing & caping with PVC gang box suitable ways fixing on wall with all fittings/ accessories for mounting of switches/sockets and fan regulators etc complete all as specified.
All as per item No. 15 above but for ceiling Fan, one point controlled by one switch.
All as per item No. 15 above but for Exhaust Fan point, one point controlled by one switch.
All as per item No. 15 above but for socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 15 above but for socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 15 above but with call bell point, one point controlled by one switch.
All as per item No. 15 above but with 4.0 sq mm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
Supply and fixing Switch piano type one way 5 amps 240 volts complete.
Supply and fixing Bell push flush type 5 amps 240 volts complete.
Supply and fixing Socket outlet 5 pin 5 Amps flush type complete.
Supply and fixing for Switch piano flush button single pole one way 15 amps 240 volts complete.
Supply and fixing for Socket out let 2 in 1, 6 pin, 5 and 15 amps multi purpose flush type, 230 volts.
Supply and fixing electronic fan regulator step, 250V flush type on the exiting phenolic laminated sheet etc.
M&L for concealed Point wiring ( MODULAR FITTING ) for light point controlled by one switch with 1.5 Sqmm PVC FRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable confirming to IS-694 and FRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, drawn through in and including rigid PVC conduit of suitable size, with all fittings, ISI marked and accessories including modular sunken/terminal boxes for modular wiring, mild steel sheet recessed in wall including modular white cover with frame with a coat of black bituminous paint and suitable for fixing of switches / sockets etc. complete including cutting/chasing and making good wall/ceiling surfaces complete all as specified and as directed. Note : Cost of cutting of chases wherever required in walls / floors and making good the same, is deemed to be included in the quoted unit rate of point wiring.
All as per item No. 28 above but for ceiling Fan point, one point controlled by one switch on the same board.
All as per item No. 28 above but for Exhaust Fan point, one point controlled by one switch on the same board.
All as per item No. 28 above but for socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 28 above but with One socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 28 above but with call bell point, one point controlled by one switch.
All as per item No. 28 above but with 4.0 sq mm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
Supply and fix Modular switch flush type, one way 5 Amp ISI Marked complete.
Supply and fix Modular Bell push, flush type, 5 amp ISI Marked complete.
Supply and fix Modular socket outlet 2 in 1, 5 pin, 6 Amp, ISI Marked complete.
Supply and fix Modular Switch 15 amp flush type ISI Marked complete.
Supply and fix Modular Socket outlet 2 in 1, 6 pin, 6 and 16 Amp ISI Marked complete.
Supply and fix Modular Electronic fan regulator 2 module, 240 Volt complete.
Supply and fixing ceiling rose surface bakelite 3 terminals.
Supply & fixing Lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings complete all as specified and directed.
S&F in replacement LED light fitting, 20 W, 4 ft long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired complete all as specified and directed.
S&F in replacement recess mounting LED slim ceiling light with extruded aluminium housing and milky diffuser with 36W, 2'X2' (600X600X11mm) LED slim panel complete all as specified and directed.
S&F in replacement LED light fitting 2 Feet long 10 Watt LED Batten light for mirror and as wall light application complete all as specified and directed.
S&F in replacement LED flat Bulkhead fitting 10 watt complete and fixing to wall / celing including fixing arrangement with clamps/ scrue/nuts/ bots /washers etc and connecting complete all as specified and directed.
S&F in replacement building security light fitting 35 W LED New generation Energy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadwayluminars with high power LEDs as light source and electronic drive including connecting complete all as specified and directed.
S&F in replacement security light mounting bracket, GI pipe 40mm dia medium grade for mounting bracket bent to shape 0.6 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as specified and directed.
S&F in replacement MS sheet 1.00 mm thick, louver shutter for exhaust fan suitable size for up to 350mm sweep with all accessories, fixing on wall complete all as specified and directed.
S&F in replacement MS sheet 1.00 mm thick, louver shutter for exhaust fan suitable size for 350mm to 450mm sweep with all accessories, fixing on wall complete all as specified and directed.
S&F in replacement Decorative LED gate light 40 Watt, made up of high grade unbreakable polycarbonate material suitable for mounting on pipe dia 40/50 mm including conecting and fixing on post top with necessary fixing arrangement complete all as specified and directed.
M&L for replacement of flexible cord copper conductor of size 1.00 Sqmm, twin core, flat cable for connection to light fitting/fans from ceiling roses complete all as specified and directed.
M&L for replacement Sub main wiring with PVC insulated cable of size 2 X 4.0 Sqmm + 1 X 2.5 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc complete all as specified and directed. .
All as per item No.53 above but sub main wiring of size 2 X 6 Sqmm + 1 X 4.0 Sqmm as earth wire
Supply and fixing Polycarbonate AC Box with Industrial Socket 16Amp 3 Pin. The AC Box shall be anti-acid & anti corrosive, Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The Box DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. Panels made by approved make Enclosures Hensel, ABB. Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing] complete all as specified and directed. . Make-Hensel/Rittal/Emitter/Schneider
S & F Meter boxes made of Lid PC and base is polystyrene Hensel reference : KG series suitable . Meter Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The Meter box shall have an optional cable entry at the bottom the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closed will be tool operated. it will be sealable with accessories. In the event of formation of condensed water, the Meter box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance. The Meter box shall fulfill the following standards Weatherproof : Rainwater proof, temperature resistant. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. IEC 60529 : IP 65 degree of protection. UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4 The Meter Box with Suitable Glands 3 Nos with each and chromium plated clamps, nut bolts complete all as per manufacturer’s instructions. Make : Cat Part :- KG 9003 of Hensel/Siemens/GE Power/Schneider/ L&T/ABB. Manufacturer should submit routine test certificate of CJB/PJB
Supply and fixing Loadline Vertical TPN DB prewired distribution board doble door, 8 way TPN IP66 ( in accordance with IEC 60 529), one No MCCB 125 Amps as incomer and four Nos of MCB TPN 40 Amp/16 nos MCB SP/8 Nos MCB SPN as required for outgoing, double door type Transparant Lid , made of high quality Polycarbonate (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC ) enclosure 415V with 63 Amps rated standard busbar of suitable size. The high flexibility of the modular enclosure system allows an easy upgrading of the assembly including bus bar system at any time even after many years The DB shall have high grade gasket made of Polyurethane ( PUR ) Dependent on the System: Environmental conditions for distribution boards according to IEC 61439-3: -5 °C up to 35 °C, max. + 40 °C; humidity: 50% at 40°C, 100% at 25 °C for empty enclosures: - 25°C up to + 70 °C. Enclosure should be totally insulated, protection class II. And rated insulation voltage should be 690V AC as per IEC 60664. The feeder pillar shall have following certificates and safety features: Weather proof: UV resistant according to IEC 61439-1, clause no 10.2.4: The material is examined for UV resistance IEC 60 695-2-11: should withstand glow wire test at 9600C UL subject 94, should be flame retardant and self-extinguishing in nature. IEC 61 439-3: Intended to be operated by ordinary person. Toxic behaviour: silicone- and halogen-free
Supply and fix IP 65 Thermoplastic PS polystyrene weatherproof MCB Box suitable for any makes MCBs, for 12 Way ( 14 MCB's SP Cut ) with multi - level knockouts for cable glands in different sizes. Double door with IP-65 protection single phase 240 volts, including neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification. The MCB box shall fulfill the following technical features: • for the installation of DIN rail equipment up to 63 A, top hat profile 35 mm • with transparent lid, sealable • locking device for hinged lid and sealing facility see accessories • with cable entry cover • protective cover can be cut out • colour: grey, RAL 7035standards The MCB box shall fulfill the following standards: Weatherproof : Rainwater proof, temperature resistant, IP65 IEC 60670-24 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. IEC 60529 : IP 65 degree of protection.
All as Per Item No 58 above but IP 65 Thermoplastic PS polystyrene weatherproof MCB Box suitable for any makes MCBs, for 8 Way ( 9 MCB's SP Cut ) with multi - level knockouts for cable glands in different sizes. Double door with IP-65 protection single phase 240 volts, including neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match specification.
All as Per Item No 58 above but IP 65 Thermoplastic PS polystyrene weatherproof MCB Box suitable for any makes MCBs, for 4 Way ( 6 MCB's SP Cut ) with multi - level knockouts for cable glands in different sizes. Double door with IP-65 protection single phase 240 volts, including neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match specification.
All as Per Item No 58 above but IP 65 Thermoplastic PS polystyrene weatherproof MCB Box suitable for any makes MCBs, for 2 Way ( 4 MCB's SP Cut ) with multi - level knockouts for cable glands in different sizes. Double door with IP-65 protection single phase 240 volts, including neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match specification.
Supply and fix MCB TPN 'B' series, 415 volts, 50Hz, 63 Amps, suitable for high inrush current loads complete all as directed.
Supply and fix 'B' series MCB SPN 40/32 amps, 240 volts, 50Hz.
Supply and fix 'B' series MCB SP 6 to 32 amps, 240 volts, 50Hz.
S&F in replacement 1100 Volts grade heavy duty service line cable PVC insulated stranded aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or cicrular of aluminium condoctors size 10 Sqmm stranded conductor all as directed.
All as per item No.65 above but stranded aluminium condoctors size 6 Sqmm.
Supply and fix of PVC flexible copper coductor cable of size 2.5 sqmm, 3 core as connections to MCB/socket to geysers all as specified.
Supply and fix door bell, Ding Dong AC, 230 volts, single pole
Supply and fixing in repair LED Bollard 13 watt 800mm 5700K, IP 54 made of gray color coated aluminum as specified and directed.
M/S SANGA SINGH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .