Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAdmitted-Finance | ₹12.6 L | L1 | Admitted-Finance |
| 2 | L2₹15.3 LAdmitted-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹15.3 L | L2 | Admitted-Finance |
| 3 | L3₹18.3 LAdmitted-Finance | ₹18.3 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DWARKADHISH ENTERPRISE L2 | M/s Prakash Enterprises L1 | Krishna Bhoomi Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00Comprehensive maintenance of storage type electric water heater (geyser) comprising of the following checks/test including repair to unsv parts/components at different locations under GE (AF) Jamnagar-02. (i) Taking down geysers from existing position after disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of inner tank with descaling solution & water leakage testing of tank & rectification of leakage.Testing of thermostat for serviceability. (iv) Checking of pressure release valves & non return valve etc. to ensures free movement / smooth operation of these components.(v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (vi) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified & directed. Note: All major defective unserviceable components such as thermostat, storage tank, heating elements, safety valves etc required for replacement shall be measured and paid separately as supply only under respective items of this BOQ, however quoted rates shall be deemed to includes for minor spare parts such as nut- bolts, screw, glands, packing etc.The following capacity of storage water heater are catered for as under:- | ||||||
| 1.10 | (a) 25 Ltr Capacity | 80 | Each | 100 ₹8,000 Lowest | 200 ₹16,000 | 125 ₹10,000 |
| 1.20 | (b) 50 Ltr Capacity | 5 | Each | 125 ₹625 Lowest | 200 ₹1,000 | 150 ₹750 |
| 2.00 | Supply only thermostats ISI marked suitable for 25 / 50 litres capacity geyser, complete all as specified & directed. | 320 | Each | 200 ₹64,000 | 150 ₹48,000 Lowest | 250 ₹80,000 |
| 3.00 | Supply only of safety valve / high pressure release valve ISI marked suitable for geyser of any capacity, complete all as specified & directed. | 15 | Each | 125 ₹1,875 Lowest | 200 ₹3,000 | 150 ₹2,250 |
| 4.00 | Supply only heating element of 1 or 1.5 KW capacity including rubber washers ISI marked as per sample for existing, complete all as specified & directed. | 80 | Each | 1,100 ₹88,000 | 300 ₹24,000 Lowest | 1,500 ₹1,20,000 |
| 5.00 | Supply only heating element of 2 KW capacity including rubber washers ISI marked as per sample for existing, complete all as specified & directed. | 280 | Each | 1,200 ₹3,36,000 | 300 ₹84,000 Lowest | 1,650 ₹4,62,000 |
| 6.00 | Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 25 litres capacity geysers, complete all as specified & directed. | 2 | Each Job | 3,000 ₹6,000 | 1,000 ₹2,000 Lowest | 3,250 ₹6,500 |
| 7.00 | Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 50 litres capacity geysers, complete all as specified & directed. | 1 | Each Job | 3,500 ₹3,500 | 1,000 ₹1,000 Lowest | 4,000 ₹4,000 |
| 8.00 | Supply only apparatus plate suitable for 25 litres capacity geysers as per sample for existing item, complete all as specified & directed. | 6 | Each | 1,450 ₹8,700 | 400 ₹2,400 Lowest | 1,650 ₹9,900 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Jul 2026, 6:00 pmClosed
GE (AF) JAMNAGAR NO.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINT OF SOLAR WATER HEATER, GEYSERS AND OTHER E/M REPAIR WORKS AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2026_MES_772842_1
8638/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) JAMNAGAR NO.2
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.2
₹30,000
Yes
17 Jul 2026
17 Jun 2026
17 Jul 2026
17 Jun 2026
15 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Comprehensive maintenance of storage type electric water heater (geyser) comprising of the following checks/test including repair to unsv parts/components at different locations under GE (AF) Jamnagar-02. (i) Taking down geysers from existing position after disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of inner tank with descaling solution & water leakage testing of tank & rectification of leakage.Testing of thermostat for serviceability. (iv) Checking of pressure release valves & non return valve etc. to ensures free movement / smooth operation of these components.(v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (vi) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified & directed. Note: All major defective unserviceable components such as thermostat, storage tank, heating elements, safety valves etc required for replacement shall be measured and paid separately as supply only under respective items of this BOQ, however quoted rates shall be deemed to includes for minor spare parts such as nut- bolts, screw, glands, packing etc.The following capacity of storage water heater are catered for as under:- | - | - | - | - |
| 0.0 | (a) 25 Ltr Capacity | 80 | Each | - | - |
| 0.9 | (b) 50 Ltr Capacity | 5 | Each | - | - |
| 0.0 | Supply only thermostats ISI marked suitable for 25 / 50 litres capacity geyser, complete all as specified & directed. | 320 | Each | - | - |
| 0.0 | Supply only of safety valve / high pressure release valve ISI marked suitable for geyser of any capacity, complete all as specified & directed. | 15 | Each | - | - |
| 0.0 | Supply only heating element of 1 or 1.5 KW capacity including rubber washers ISI marked as per sample for existing, complete all as specified & directed. | 80 | Each | - | - |
| 0.0 | Supply only heating element of 2 KW capacity including rubber washers ISI marked as per sample for existing, complete all as specified & directed. | 280 | Each | - | - |
| 0.0 | Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 25 litres capacity geysers, complete all as specified & directed. | 2 | Each Job | - | - |
| 0.0 | Supply only storage tank made out of copper sheet and confirming to IS- 2082 (1973), suitable for 50 litres capacity geysers, complete all as specified & directed. | 1 | Each Job | - | - |
| 0.0 | Supply only apparatus plate suitable for 25 litres capacity geysers as per sample for existing item, complete all as specified & directed. | 6 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
12PTenderDocs.pdf
Tender Documents • 0.85 MB
BOQ_865408.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].