Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAdmitted-Finance A 41 PHASE II MAYAPURI INDUSTRIAL ESTATE NEW DELHI 110 064 INDIA | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹3.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.2 CrAdmitted-Finance | ₹4.2 Cr | L2 | Admitted-Finance |
| 3 | L3₹4.3 CrAdmitted-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹4.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹4.4 CrAdmitted-Finance HIMALAYA HOUSE D 248 SECTOR 10 NOIDA DIST G B NAGAR U P 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.4 Cr | L4 | Admitted-Finance |
| 5 | L5₹4.4 CrAdmitted-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0002177 | JAMNAGAR | GUJARAT | 361001 | ₹4.4 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S.L. ELECTROMECH PVT. LTD. L1 | KLYSTRON ELECTRONICS PVT. LTD. L6 | JITENDRA ELECTRICALS L8 | DOSHI ELECTRIC ENGG. CO. L3 | HIMALAYA GENERATORS L4 | Power And Instrumentation Guj Ltd L2 | Ascent Electrification Engineers L5 | GAYATRI ELECTRICAL L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Item no. 1 (Sr. No. 1 to 49) - 11 KV HT PANEL BOARD | |||||||||||
| 2.00Supply, Installation, Testing & Commissioning of indoor type (IP 42) floor mounted metal clad, 11 KV Switch Board VCB panel with following VCBs, totally enclosed & fully interlocked, truck mounting, horizontal draw out, horizontal isolation type vacuum breaker as per IS / IEC 62271- 100 (2007) for breakers & 200 (2003), for panels / IS3247 as amended up to date, having capacities as mentioned below, free standing extensible on both sides, single break, trip free mechanism, motorised charged and auto/ manually closing breaker suitable for use on 11 KV, 3 Phase, 50Hz A.C. supply with short circuit fault level of 500 MVA, complete with self-contained short time current 26.3 kA for 3 sec, Internal Arc Test for AFLR 26.3 kA for 1 sec at individual compartments i.e. busbar, VCB, and cable compartment, rack in and rack out mechanism, air insulated but encapsulated copper bus bars capacity meeting fault level current, DC power pack, breaker featured with mechanical ON / OFF indicator with hand trip device, Breaker control TNC switch and all accessories such as shunt trip coil, and auxiliary switch of 4NO+4NC, motorised and manually operated spring assisted closing mechanism, emergency trip push button, interconnections, space heaters, earthing, etc. and equipped with following switchgears and accessories, connections suitable for cable uptown 3C x 185 sqm XLPE cable of 11 KV grade (cable entry from bottom), Separate earthing switch shall be provided for Cable earthing . The earthing truck shall be so designed that it is impossible to earth a live. cable terminations suitable for 3C x 185 sq.mm. XLPE 11 KV cable. | |||||||||||
| 3.00A. Incomer 2 Nos. consisting of following; | |||||||||||
| 4.002 Nos. of 630 Amp, 11 KV, 3 Ph, 3P VCB | |||||||||||
| 5.001 No for each incomer - Multifunction Meter with accuracy class 0.5 LED display of I, V, Hz, Active, Reactive, Apparent Power & Energy, Power factor, %THD, Maximum demand load, (complying with IEC61557-12) with RS 485 & Ethernet port and protection MCB and required accessories to complete the system | |||||||||||
| 6.003 Nos. (01 set for each incomer) Cast resin draw out type PTs 11 KV / √3 / 110 √3, class 0.5,100 VA burden including HT HRC fuse on 11 KV Side and MCBs on secondary side protection. | |||||||||||
| 7.003 No. (01 set for each incomer) Cast resin insulated Dual core 3 CTs 30 / 5-5A of 15VA burden and accuracy Class -0.5 for metering and class 5P10 for protection. | |||||||||||
| 8.00Aux. relays for Anti Pumping & indication. (01 set for each incomer) | |||||||||||
| 9.00Trip Circuit supervision relay - (01 set for each incomer) | |||||||||||
| 10.00Master Trip Circuit Relay (01 set for each incomer) | |||||||||||
Updated dates
Tender Value
₹4.2 Cr
EMD Value
₹12.5 L
Closing Date
12 May 2026, 6:00 pmClosed
SENIOR MANAGER -EE
Senior Manager (Engg-E), (Bid Manager) ) O/o General Manager (Project), 3rd Floor, Block-1, A2 Wing, Karmayogi Bhavan, Sector 10A, Gandhinagar, Gujarat - 382010
Development of New Greenfield Airport at Dholera, Ahmedabad (Gujarat). Phase -1. SH Provision of power supply to ASR/MSSR building and associated Electrical works
2026_AAI_273556_1
Development of New Greenfield Airport at Dholera Ahmedabad Ph 1 SH Electrical works ASR-MSSR
Open Tender
Electrical Works
150 days
DHOLERA AIRPORT SITE
AS PER TENDER DOCUMENT
4 documents required · 4 mandatory
₹1,180
Dholera International Airport Company Limited
₹12.5 L
24 Jun 2026
2 Apr 2026
18 May 2026
2 Apr 2026
12 May 2026
2 Apr 2026
2 Apr 2026 - 13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Item no. 1 (Sr. No. 1 to 49) - 11 KV HT PANEL BOARD | - | - | - | - | Item 1 |
| 2 | Supply, Installation, Testing & Commissioning of indoor type (IP 42) floor mounted metal clad, 11 KV Switch Board VCB panel with following VCBs, totally enclosed & fully interlocked, truck mounting, horizontal draw out, horizontal isolation type vacuum breaker as per IS / IEC 62271- 100 (2007) for breakers & 200 (2003), for panels / IS3247 as amended up to date, having capacities as mentioned below, free standing extensible on both sides, single break, trip free mechanism, motorised charged and auto/ manually closing breaker suitable for use on 11 KV, 3 Phase, 50Hz A.C. supply with short circuit fault level of 500 MVA, complete with self-contained short time current 26.3 kA for 3 sec, Internal Arc Test for AFLR 26.3 kA for 1 sec at individual compartments i.e. busbar, VCB, and cable compartment, rack in and rack out mechanism, air insulated but encapsulated copper bus bars capacity meeting fault level current, DC power pack, breaker featured with mechanical ON / OFF indicator with hand trip device, Breaker control TNC switch and all accessories such as shunt trip coil, and auxiliary switch of 4NO+4NC, motorised and manually operated spring assisted closing mechanism, emergency trip push button, interconnections, space heaters, earthing, etc. and equipped with following switchgears and accessories, connections suitable for cable uptown 3C x 185 sqm XLPE cable of 11 KV grade (cable entry from bottom), Separate earthing switch shall be provided for Cable earthing . The earthing truck shall be so designed that it is impossible to earth a live. cable terminations suitable for 3C x 185 sq.mm. XLPE 11 KV cable. | - | - | - | - | Item 2 |
| 3 | A. Incomer 2 Nos. consisting of following; | - | - | - | - | Item 3 |
| 4 | 2 Nos. of 630 Amp, 11 KV, 3 Ph, 3P VCB | - | - | - | - | Item 4 |
| 5 | 1 No for each incomer - Multifunction Meter with accuracy class 0.5 LED display of I, V, Hz, Active, Reactive, Apparent Power & Energy, Power factor, %THD, Maximum demand load, (complying with IEC61557-12) with RS 485 & Ethernet port and protection MCB and required accessories to complete the system | - | - | - | - | Item 5 |
| 6 | 3 Nos. (01 set for each incomer) Cast resin draw out type PTs 11 KV / √3 / 110 √3, class 0.5,100 VA burden including HT HRC fuse on 11 KV Side and MCBs on secondary side protection. | - | - | - | - | Item 6 |
| 7 | 3 No. (01 set for each incomer) Cast resin insulated Dual core 3 CTs 30 / 5-5A of 15VA burden and accuracy Class -0.5 for metering and class 5P10 for protection. | - | - | - | - | Item 7 |
| 8 | Aux. relays for Anti Pumping & indication. (01 set for each incomer) | - | - | - | - | Item 8 |
| 9 | Trip Circuit supervision relay - (01 set for each incomer) | - | - | - | - | Item 9 |
| 10 | Master Trip Circuit Relay (01 set for each incomer) | - | - | - | - | Item 10 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
DNIT-radar.pdf
Tender Documents • 15.98 MB
BOQ_319606.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid