Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 CrAccepted-AOC | ₹30.1 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technical Qualification Criteria not satisfied |
Tender Value
₹32.0 Cr
EMD Value
₹5 L
Closing Date
24 Jan 2022, 3:00 pmClosed
Regional Manager
WAPCOS LIMITED 4th Floor, ISAACS Tower, Jawahar Nagar, Kadavanthra, Kochi, Kerala-682020
Development of Government Medical College Pariyaram, Kannur District- Maintenance /Renovation of existing buildings
2021_WAPCO_456692_1
WAP/INFRA/KERALA/2021/GMCP/360
Open Tender
Civil Works - Buildings
270 days
Pariyaram
Please refer Tender documents.
17 documents required · 17 mandatory
₹16,800
₹5 L
WAPCOS LIMITED
7 May 2022
27 Nov 2021
25 Jan 2022
27 Nov 2021
24 Jan 2022
7 Dec 2021
6 Dec 2021
Amount
Painting
od302089/2019_2020 : Cleaning the surface and removing dirt, dust, grease, oil, algae, fungus, vegetable growth wash by scrapping, sand papering and wire brush and preparing the surface smooth including necessary repairs to scratches, including filling the holes and cracks on the surface all as per direction of Engineer-in-charge (The rate is inclusive of all materials & labors involved)
13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
od303403/2019_2020 : Finishing textured walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
od25433/2020_2021 : "Applying one coat of water thinnable cement primer of approved brand and manufacture on textured wall surface : Water thinnable cement primer"<br>
od242735/2020_2021 : Repairs to aggregate plaster of external walls exactly matching with the existing finishing of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead with CM 1:4 (1 CEMENT&4 COURSE SAND)and with suitable aggregate
Vertical Pipe Works
od14609/2021_2022 : Dismantling PVC pipes manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:<br>15 mm to 40 mm nominal bore
od14626/2021_2022 : Dismantling PVC pipes manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges<br>Above 40 mm nominal bore
50.18.9.12.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall
50.18.9.13.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
50.18.9.14.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
50.18.9.17.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
4.3.2 : Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
Manhole
19.24.1 : Dismantling of manhole including R.C.C top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead:Rectangular manhole 90x80 cm and 45 cm deep
19.25.1 : Extra for depth of manholes dismantled:Rectangular manhole 90x80 cm and beyond 45cm depth
19.24.2 : Dismantling of manhole including R.C.C top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials into municipal dumps within 50 m lead:Rectangular manhole 120x90cm and 90 cm deep
19.25.2 : Extra for depth of manholes dismantled:Rectangular manhole 120x90cm and beyond 90 cm depth
15.47.1 : Dismantling asbestos cement pressure pipes including excavation and refilling trenches after taking out the pipes manually / by mechanical means and stacking the pipes within 50 metres lead as per direction of Engineer-in-Charge:Upto 150 mm diameter
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885
19.7.2.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With Sewer bricks conforming to IS : 4885
19.8.2.2 : Extra for depth for manholesSize 120x90 cmWith Sewer bricks conforming to IS: 4885
19.6.1 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:100 mm dia R.C. C pipe
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe
TOILET RENOVATION
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
9.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
15.44.1 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:15 mm to 40 mm nominal bore
15.44.2 : Dismantling G.I. pipes ( external work) including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges:Above 40 mm nominal bore
15.52 : Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes
18.9.9 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work100 mm nominal inner dia pipes
18.22.2 : Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern
17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
17.28.2.2 : Flexible pipe40 mm dia
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
od298124/2019_2020 : Supplying and Fixing of "MULTI FLOOR TRAP 110 X 75 X 50 mm"
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
14.82 : Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge
14.75 : Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
11.48.1 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 500x500 mm
od9396/2020_2021 : Providing and laying anti skid Ceramic floor tiles of size 400 x 400 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
11.50 : Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles
Windows Changing
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.12.2 : Of area beyond 3 sq. metres
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
9.147D.1 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
9.147E.2 : Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).<br> Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm).
9.147D.5 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)
9.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass pane
9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane
od77793/2021_2022 : supply and filling of gap between the window frame and wall with weather proof silicon sealent over backerord of required size of approved quality
Fire Pumps & Accessories
od290396/2019_2020 : MAIN PUMP : Supply,Installation,Testing and Commissioning of main fire fighting pump 2280 LPM,70 m Head of horizontal centrifugal End Suction type with cast iron casing, Bronze impeller, coupled to a squirrel cage induction motor SPDP type or mono block pump totally enclosed fan cooled with supply condition 415V 3phas,50Hz foot mounted type rated for suitable HP at 2990 RPM including supply and installation of all accessories such as standard coupling, coupling guard, common base plate and foundation bolts. The pump shall produce a pressure of 3 kg/sq. m at top most hydrant level.
od18010/2021_2022 : SPRINKLER PUMP Supply,Installation,Testing and Commissioning of Sprinkler fire fighting pump 2280 LPM,70 m Head of horizontal centrifugal End Suction type with cast iron casing, Bronze impeller, coupled to a squirrel cage induction motor SPDP type or mono block pump totally enclosed fan cooled with supply condition 415V 3phas,50Hz foot mounted type rated for suitable HP at 2990 RPM including supply and installation of all accessories such as standard coupling, coupling guard, common base plate and foundation bolts. The pump shall produce a pressure of 3 kg/sq. m at top most hydrant level.
od290397/2019_2020 : DIESEL ENGINE DRIVEN PUMP:- Supply Installation, testing and commissioning of Stand By Diesel Engine driven pump Sutable HP with control panel and battery charger of centrifugal end suction type suitable for automatic operation rated for 2280 LPM at 70 m head at high efficiency volute type with cast iron casing, Bronze impeller Pump coupled to a diesel engine at 1800 RPM including supply of all accessories such as common base plate suitable foundation for engine and pump, , suitable size Battery, coolant, lubricating oil, exhaust piping, necessary controls such as pressure switch, gauge and interconnecting cable from control panel to Battery etc.<br>
od290398/2019_2020 : JOCKEY PUMP:Supply and errection of fire fighting pump 180LPM,70 m head horizontal end section.centrifugal multy stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase, 50Hz with Suitable HP
od290401/2019_2020 : Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.
od290402/2019_2020 : Supply, installation, testing and commissioning of C.I. Non-Return Valve slim seal type PN.16 with required flanges, nuts & bolts, gasket etc. complete
od290403/2019_2020 : AIR RELEASE VALVE:Supply and errection of air release valve as per IS:778 of size 1/2 inch BSP threaded.
od290404/2019_2020 : Ball VALVE:Supply and erection of cast iron Ball valve
od290406/2019_2020 : AIR CUSSION VESSEL: Supply,Installation, Testing and commissioning of Air Cussion Vessel of 250mm dia with automatic air release cock with drain pipe,drain valve and a shut off and 120cm height complete
od290407/2019_2020 : PRESSURE SWITCHES: Supply,Installation, Testing and Commissioning of pressure switches
od290408/2019_2020 : PRESSURE GAUGE: Supply,Installation, Testing and Commissioning of pressure gauge
od290409/2019_2020 : "Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required : 150mm dia"
od290410/2019_2020 : TERRACE PUMP:Supply and erection of fire fighting pump 900 LPM,35 m head horizontal end section.centrifugal multi stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase,50Hz with Suitable HP
od290411/2019_2020 : TERRACE PUMP:Supply and erection of fire fighting pump 450 LPM,35 m head horizontal end section.centrifugal multi stage with cast iron casing, Bronze impiller electronic driven auto start Jockey Pump coupled with TEFC motor working on 415V,3Phase,50Hz with Sutable HP
od290412/2019_2020 : MOTOR CONTROL PANEL:Supply, installation, testing and commissioning of Automatic Pump Control Panel, Pressure Switch and Pressure Gauge<br>
Fire Hydrant System
od18077/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)
od18081/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)
od18082/2021_2022 : Above Ground Piping: Supply, erection, testing and commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessery)
od20281/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 200mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc. complete. etc. complete (The Rate for excavation shall be extra as applicable
od20283/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc. complete. etc. complete (The Rate for excavation shall be extra as applicable
od20285/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc complete. etc. complete (The Rate for excavation shall be extra as applicable
od20287/2021_2022 : Under Ground Piping: Supply, erection, testing and commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, laying under ground, by using suitable supports and wrapping with polymer corrosion protection tape confirming to IS 10221 with proper overlapping, trimming etc complete. etc. complete (The Rate for excavation shall be extra as applicable
od290420/2019_2020 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.<br><br>a) 150 mm Dia
od290421/2019_2020 : HYDRANT VALVE:- Supply Installation, Testing and commissioning of single headed GUN METAL hydrant valve conforming to IS:5290 and with ISI mark of 63/80 mm Dia oblique type with instantaneous hose coupling adapter.(point-155, YH-38)
od290422/2019_2020 : BRANCH PIPE:- Providing and installation of Branch pipe of 63 mm dia having GUN METAL body with hexagonal head of 20mm dia nozzle conforming to IS903
od290423/2019_2020 : FIRE HOSE:-Supply, installation, testing and commissioning of controlled percolated hose in 15M length of 63 mm dia and tested to bursting pressure of 15kg/sqcm and with SS coupling as per IS:901 <br><br><br>
od290424/2019_2020 : HOSE REEL:-Supply, installation, testing and commissioning of hydraulic hose reel complete with swing type drum,19mm rigid hose having a length of 30 Mtrs. with stop cock and PVC / chrome plated nozzle on one end and all other necessary fixing materials
od290425/2019_2020 : BALL VALVE : Supplying, installing, testing and commissioning of Cast iron Ball valves with fittings of screwed end type.<br><br>a) 20 mm Dia
od290427/2019_2020 : DOUBLE DOOR HOSE CABINET : Supply, installation, testing and commissioning of Double Door Hose Cabinet to accommodate Two piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made of 20swg M.S Sheet, glass fronted with hinged door and lock. The cabinet is spray painted to scarlet red color.
od290428/2019_2020 : FIRE BRIGADE INLET/TANK FILLING INLET : Supply, installation, testing and commissioning of Fire Brigade Inlet connection with 4 nos of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. etc. Pipe manifold shall be connected to wet riser main.
Sprinkler System
od20736/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 150mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20756/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 100mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20757/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 80mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20758/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 65mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20760/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 50mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20761/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 40mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20764/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 32mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20767/2021_2022 : Sprinkler Piping: Supply, Installation, Testing and Commissioning of 25mm Dia M S 'C' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports, The pipe shall be painted with one coat of primer and two coats of synthetic enamel paint of approved colour / shade. (Core cutting in walls/beams/columns for laying pipes shall be provided by client, if necessary)
od20800/2021_2022 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning 150mm Dia CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.
od20802/2021_2022 : BUTTER FLY VALVE: Supplying, Installing, testing and commissioning 80mm Dia CI Butterfly valve slim seal standard lever operated type PN.16 with required flanges, nuts, bolts etc. complete.
od20804/2021_2022 : SPRINKLER BULB: -Supply, installation, testing and commissioning of Pendent type 15mm Sprinkler bulbs designed to operate at 68 deg. Celsius etc. with necessary fittings etc, complete (Extension of Pipeline /Flexible pipe will be at extra cost)
od20806/2021_2022 : SPRINKLER BULB: -Supply, installation, testing and commissioning of Side Wall/ Upright Type 15mm Sprinkler bulbs designed to operate at 68 deg. Celsius etc. with necessary fittings etc, complete (Extension of Pipeline /Flexible pipe will be at extra cost)
od20807/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1000 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.
od20808/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1200 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.
od20809/2021_2022 : SPRINKLER FLEXIBLE PIPE :Supply, installation, testing & commissioning of 1500 mm length stainless steel corrugated flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and upto 25 mm dia with union / reducer collar, clamps etc. as required.
Fire Detection & Alarm System
od290461/2019_2020 : FIRE ALARM CABLE:Supply, laying and clamping of PVC insulated and PVC sheathed armoured copper fire alarm cable 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. (2X 1.50 sq mm) <br>
od290462/2019_2020 : INTELLIGENT ADDRESSABLE HEAT DETECTORS:Supply and errection of ironisation type Heat detectors with imported base <br>
od290463/2019_2020 : INTELLIGENT ADDRESSABLE SMOKE DETECTORS : Supply and erection of ironisation type smoke detectors with imported base <br>
od290464/2019_2020 : INTELLIGENT ADDRESSABLE ELECTRONIC ALARMING HOOTER:Supply, installation, testing and commissioning of intelligent Electronic Hooter (Sounder) as per standard specification. <br>
od290465/2019_2020 : INTELLIGENT ADDRESSABLE MANUAL CALL POINT: Supply, Installation, testing and commissioning of intelligent Manual Call Point break glass type as per standard specification. <br>
od290466/2019_2020 : REPEATER PANEL :Supply, installation, testing & commissioning of Active repeater panel LCD for monitoring the fire alarm system @ security block.
od290467/2019_2020 : ELECTRONIC ALARMING HOOTER:Supply, installation, testing and commissioning of Electronic Hooter (Sounder) as per standard specification. <br>
od290468/2019_2020 : MANNUAL CALL POINT: Supply, Installation, testing and commissioning of Manual Call Point break glass type as per standard specification.
od290469/2019_2020 : FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 6 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.<br>
od290470/2019_2020 : FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 4 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.<br>
od308599/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 2 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.
od308600/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 6 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.
od308601/2019_2020 : INTELLIGENT AUTOMATIC FIRE ALARM PANEL: Supply, installing, testing and commissioning of Micro processor based Intelligent Addressible Main Fire alarm control panel of 10 Loop capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.
Talk Back System
od290474/2019_2020 : TALK BACK UNIT:Supply installation testing and commissioning of Talk back Unit
od290475/2019_2020 : FIRE ALARM CABLE:Supply, laying and clamping of PVC insulated and PVC sheathed armoured copper fire alarm cable 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. (2X 1.50 sq mm)
Fire Extinguishers
od290477/2019_2020 : CO2 Extinguisher :Supply and erection of Co2 type fire extinguisher with 4.5 Kg capacity as per IS:2171
od290478/2019_2020 : DCP: Supply and erection of dry chemical powder type fire extinguisher with 4Kg capacity as per IS:2171
Signages
od290479/2019_2020 : SELF GLOWING SIGNAGES:Supply and errection of Self Glowing Sign boards made out of 3 mm thick PVC form board size:12"x 4" (FIRE LIFT , EXIT,FIRE EXIT,FIRE STATION)<br>
od290480/2019_2020 : Suply and providing emergency fire escape lighting system consisting 2 nos lamp ,7 AH FMF battary charging unit ,exit sign display etc in MS enclosure<br>
FALSE CEILING
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
Light Fittings
od265248/2019_2020 : "Supplying and fixing of indoor industrial surface mounted LED commercial Batten light with driver surge protector,system wattage of 18+/- watts lumen output of lamp greater than 1600 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greeter than 70 lumen/watt and including all necessary accessories as required complete.<br>
od265249/2019_2020 : "Supply and fixing of indoor industrial surface mounted LED commercial Batten light with driver surge protector,system wattage of 30+/- watts lumen output of lamp greater than 3000 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete.<br>
od265310/2019_2020 : "Supplying and fixing of industrial surface mounted Full lit linear LED commercial Light standard 1x 4 double Decker type with driver surge protector,system wattage of 36 +/- watts lumen output of lamp greater than 3000 lumen, power factor >0.9 rated life of L 70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>
od265311/2019_2020 : "Supplying and fixing of Moon Std LED Recess commercial light with driver surge protector,system wattage of 15+/- watts lumen output of lamp greater than 800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>
od265312/2019_2020 : "Supplying and fixing of Texon Std Recess commercial tech zone 1200 x 150 mm light with driver surge protector,system wattage of 24+/- watts lumen output of lamp greater than 2000 lumen, power factor >0.9 rated life of L70 @ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete. "<br>
od265313/2019_2020 : "Supplying and fixing of Cask Bulk Head LED Wall Mounted 4000 k industrial light with driver surge protector,system wattage of 12+/- watts lumen output of lamp greater than 800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessarily accessories as required complete."<br>
od265314/2019_2020 : Supplying and fixing of LT MAZE XL LED Wall Mounted 6500 K,IP 66 light with driver surge protector,system wattage of 1.44+/- watts lumen output of lamp greater than 150 lumen, power factor >0.9 rated and including all necessary accessories as required complete.<br>
od265315/2019_2020 : "Supplying and fixing of LT 100 W ,12 V Power supply with IP 67 protection"
od265364/2019_2020 : "Supplying and fixing of Sparkle Ultra LED Recess commercial light with driver surge protector,system wattage of 28+/- watts lumen output of lamp greater than 2800 lumen, power factor >0.9 rated life of L70@ 50,000 hours,system efficiency greater than 70 lumen/watt and including all necessary accessories as required complete."<br>
Switch/Socket/Regulator replacement
1.23.1 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.29 : Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
od141773/2021_2022 : DSOR 2018 Item 1.32<br> Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
LEVEL-1 (CHILLER REPLACEMENT)
od289841/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of air cooled Inverter scroll chiller Units with Multiple Inverter type scroll compressors, Dx type shell & tube Evaporator, Air-cooled condenser with protective black epoxy resin and hydrophilic coating for Aluminum fins, BLDC (Brush less Direct commuting) condenser fans to regulate fan speed as per cooling load requirements, Control Panels and Pre-charged R410 A Refrigerant. <br>Air cooled Inverter Scroll Chiller 35 TR Capacity<br>
od289846/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of Horizontal split casing chilled water pump sets complete with TEFC sq.cage induction motor (With Mechanical seal) stainless steel shaft, bronze impeller, base plate, couplings, pressure gauges (2 Nos. with syphon and gauge cock), anti vibration springs, guards etc. including insulation as per specifications: <br>Chiller water Pumpsets 100 [email protected] Bar.
16.1.8 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) <br> Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. <br> Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick fiber glass insulation)
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm
16.7.3.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 80 mm dia
16.7.4.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 80 mm dia
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.
od289933/2019_2020 : Dismantling and unloading of chillers 30 TR near cardio OT<br>
od289934/2019_2020 : Supply and Installation of Flexible connections of suitable pressure rating to be installed at CHILLERS, Pump sets inlets & outlets and at pipes crossing building expansion joints as per Specifications. <br>
od289935/2019_2020 : Supply Installation, Testing and commissioning of air vent<br>
16.1.9 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) <br> Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. <br> Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dia. (50mm thick fiber glass insulation)
16.7.2.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 80 mm dia
16.11.3.8 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.80mm dia.
STANDBY CHILLER TERRACE LEVEL
od289895/2019_2020 : Supply, Shifting, Installation, Testing & Commissioning of air cooled Inverter scroll chiller Units with Multiple Inverter type scroll compressors, Dx type shell & tube Evaporator, Air-cooled condenser with protective black epoxy resin and hydrophilic coating for Aluminum fins, BLDC (Brush less Direct commuting) condenser fans to regulate fan speed as per cooling load requirements, Control Panels and Pre-charged R410 A Refrigerant.<br>Air cooled Inverter Scroll Chiller 70 TR Capacity
16.1.8 : INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) <br> Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. <br> Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick fiber glass insulation)
od141557/2021_2022 : <br>DSOR 2018 Item 16.7.1.4<br>16.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.<br>16.7.1 : BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specified<br>16.7.1.3 : Butterfly valve (Manual) 125 mm<br><br><br>
16.7.2.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 100 mm dia
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia
16.7.4.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 100 mm dia
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
16.9 : Providing & fixing in position the mercury in glass industrial type thermometers.
16.11.3.7 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.100mm dia.
od289935/2019_2020 : Supply Installation, Testing and commissioning of air vent<br>
LEVEL-1 (Hrudyalaya)
od28782/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units <br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>38 HP Outdoor Unit
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>
od290051/2019_2020 : "Supply and Errection of MS Structure works with I - beam and Chequer plates <br>Room size ( 5 mtr x 3.1 mtr x 8 mtr) ( approx 2000 kg)"<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"
od290054/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>
od290055/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU"<br>AHU 30 TR, 12000 CFM & 500 Pa ESP
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290091/2019_2020 : Cleaning and Testing of Existing Ducts<br>
od290092/2019_2020 : Dismantling and unloading of PAC and Outdoor units ( For hridyalyam)<br>
LEVEL-1 (Cardio OT)
od290094/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>
od290095/2019_2020 : "Return riser plenums<br>Supply, Installation, balancing and commissioning of Aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required"<br>
od290097/2019_2020 : "Supply, Installation, Testing & Commissioning of plenum box and Hepa filter for laminar flow system<br>(8 x 4)"<br>
od290098/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 24 TR, 9600 CFM & 500 Pa (Approx.) ESP
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br> Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
od290099/2019_2020 : Dismantling and unloading of AHU ( Cardio OT)<br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
LEVEL-2 (EMERGENCY AREA)
od290105/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>25 mm"<br>
od290106/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"<br>
od290107/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>
od290108/2019_2020 : "Supply, Installation, Testing & Commissioning of HIGH STATIC INVERTER DUCTABLE:<br>Ceiling Mounted Inverter Ductable Type AC Units suitable to operate at 48°C ambient temperature comprising of Combination of hermetic inverter compressors, Matching air cooled condenser with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophilic resin film, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses, cabling, etc. and suitable for operation on 380V~415V~3Ph~50Hz A.C. supply. Oil separator suitable for the refrigerant piping, Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils of following capacities of the ODU and IDU. ( 8.5 TR)"
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL-2 (CONFERENCE HALL)
od290114/2019_2020 : "Supply, Installation, Testing & Commissioning of HIGH STATIC INVERTER DUCTABLE:<br>Ceiling Mounted Inverter Ductable Type AC Units suitable to operate at 48°C ambient temperature comprising of Combination of hermetic inverter compressors, Matching air cooled condenser with copper tubes and aluminium fins duly covered by anticorrosion and hydrophilic resin film, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses, cabling, etc. and suitable for operation on 380V~415V~3Ph~50Hz A.C. supply. Oil separator suitable for the refrigerant piping, Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils of following capacities of the ODU and IDU. ( 11 TR)<br>"<br>
od290105/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>25 mm"<br>
od290106/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"<br>
od290107/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL-3 (CENTRAL LAB)
od28783/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>24 HP Outdoor Unit
od290152/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>
od290153/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
od290154/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>(Central Lab area )<br>19.5 TR, 7800 CFM, 450 CFM FA, 500 Pa ESP"
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL-3 (BLOOD BANK)
od290153/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
od290154/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>(Central Lab area )<br>19.5 TR, 7800 CFM, 450 CFM FA, 500 Pa ESP"
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"
od28783/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>24 HP Outdoor Unit
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL-5 (NEW BORN BABY)
od290170/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>
od290171/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>
od290172/2019_2020 : "Supply , Installation testing and commissioning of INDOOR UNITS (AHU) - cordless remote and all refnet joints. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain GSS) with 40mm thick PUF panels, Floor Mounted AHU with Mixing box, Filter section with Pre Filter & Fine Filter, Coil section with 6 row deep DX cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD connecting to VRF ODU<br>16 TR, 6400 CFM, 250 CFM FA & 500 Pa ESP "<br>
od290109/2019_2020 : Supply, Installation , Testing and commsiioing of Non - return dampers / Back draft dampers to restrict flow to the blower motor of stand by machine<br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"
od28784/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units<br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>20 HP Outdoor Unit
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL-6 (A WING) (OT-13,14,15,16)
od290277/2019_2020 : Dismantling and unloading of AHU <br>
od290278/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 8 TR, 4000 CFM & 500 Pa (Approx.) ESP
od290279/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 7.5 TR, 3600 CFM & 500 Pa (Approx.) ESP
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br> Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
LEVEL-6 (K WING) (OT 7,8,9,10,11,12)
od290288/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 18 TR, 7500 CFM & 500 Pa (Approx.) ESP
od290289/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2400 CFM & 500 Pa (Approx.) ESP
od290290/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2600 CFM & 500 Pa (Approx.) ESP
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>
od290277/2019_2020 : Dismantling and unloading of AHU <br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290095/2019_2020 : "Return riser plenums<br>Supply, Installation, balancing and commissioning of Aluminium sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required"<br>
od290097/2019_2020 : "Supply, Installation, Testing & Commissioning of plenum box and Hepa filter for laminar flow system<br>(8 x 4)"<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br> Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL - 6 ( J WING ) ( OT 1,2,3,4,5,6)
od290296/2019_2020 : Dismantling and unloading of AHU <br>
od290297/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 18 TR, 7500 CFM & 500 Pa (Approx.) ESP
od290298/2019_2020 : AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2200 CFM & 500 Pa (Approx.) ESP
od290299/2019_2020 : <br>AIR HANDLING UNITS FOR EXISTING CHILLER :-Supply, Installation, Testing, Commissioning and Validation of Air Handling units. Air Handling Unit shall be Double Skinned (Outer skin - 0.6mm pre-coated GSS and Inner skin 0.6mm Plain Al) with 40mm thick PUF panels, Floor Mounted with Mixing box, Filter section with Pre Filter, Fine Filter & HEPA Filter, Coil section with 6 row deep CHW cooling coil, Fan section with direct driven type backward curved plug fans with IE-2 motor & VFD, UV lamp and all other accessories complete. <br>AHU 5.5 TR, 2700 CFM & 500 Pa (Approx.) ESP
od290282/2019_2020 : Chilled Water Manifold size suitable to AHU includes 2 Nos. Butterfly / Ball Valves, 1 No. Balancing valve, 1 No. Y-strainer, 1 No. 2 Way Valve with thermostat (with interconnected wiring between thermostat & mixing valve), 2 Nos. dial type Pressure gauges, 2 Nos. temperature Gauges, 1 No drain valve with MS 'C' class 6 m pipe for interconnection with insulation. <br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br> Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
od140739/2021_2022 : DSOR 2018 Item 16.16<br>Supplying & Fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required<br>
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
LEVEL - 6 ( C WING)
od290305/2019_2020 : Dismantling and unloading of PAC and Outdoor units<br>
od290306/2019_2020 : "Supply and fixing of INDOOR UNITS - cordless remote and all refnet joints. Air Handling Unit DOUBLE SKINNED Floor Mounted AHU with fine filter and pre filter, UV Lamp<br>(ICU ) ( VRF AHU 6F - 13)<br>22 TR, 8800 CFM, 250 CFM FA, 50mmESP "
od290171/2019_2020 : Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping complete with fittings, with suitable adjustable hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required <br>
od290100/2019_2020 : Supply, Insulation, testing and commissioning of Fresh Air Louvere with bird screen<br>
od290088/2019_2020 : "DUCT ACCOUSTIC INSULATION:-<br>Supply, Installation, Testing and commissioning of Open cell Nitrile rubber thermal insulation with 25mm thickness, 150 kg/m3 Density"<br>
od290050/2019_2020 : Supply, Installation, Testing commissioning of AHU Kit and communication Kit between AHU and VRF ODU<br>
od290052/2019_2020 : "Supply, Installation, Testing and commissioning of Drain Water Piping P.V.C with nitrile insulation complete with fittings.<br>suitable size as per number of units connected<br>40mm"<br>
od290053/2019_2020 : "Control Cabling<br>Supply, Installation, Testing and commissioning of Control cabling with saddles / supports to connect outdoor units with respective indoor units"
od28785/2021_2022 : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units <br>suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules,<br>microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant,vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required<br>28 HP Outdoor Unit
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.23.2 : INSULATION ON EXISTING PIPE <br> 16.4 Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.Nitrille rubber insulation - 25 mm
TOP ROOFING
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.4.1 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Plastering
26.28.2 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge50mm average thickness
26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter
26.29.2 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
26.32.1 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
26.32.2 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.
26.32.3 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).50 mm average thickness in 3 layers.
Lift Changing
od289566/2019_2020 : Supply and Installation of 20 pax,1 mps new lift under the existing lift wells
od289593/2019_2020 : Replacement of existing lift no. 13027 in Dental College
od289594/2019_2020 : Replacement of existing old Lift No. 13028 in Dental College
od291268/2019_2020 : Dismantling of existing lift of 20 or 15 People Capacity<br>
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
od10206/2020_2021 : Replacement of existing old Lift No. 13029 in Hospital Building
od10208/2020_2021 : Replacement of existing old Lift No. 13030 in Hospital Building
od10209/2020_2021 : Replacement of existing old Lift No. 13035 in Hospital Building
od10211/2020_2021 : Replacement of existing old Lift No. 13036 in Hospital Building
Dumb Waiter
od289731/2019_2020 : Supplying and Installation of Dumb-waiter
DG Set
od289161/2019_2020 : Supply, Fabrication, erection, testing and commissioning panel boards of free standing, floor mounting, fabricated out of 16SWG CRCA sheet cubicle type compartmentalized board suitable for operation on 440V, 3 phase, 50Hz, vermin proof, dust proof with the following mounting complete as per specifications. The design should be as per the IS standards.<br>GSB with ATS: Incomer for GSB- 1600A 4 pole Isolator. Outgoings: 1000A 4P Automatic Transfer Switch (ATS)-4 Nos, 630A 4P ATS-6 Nos, LED indication Lamps, Multifunction meters (Panel Mount) with Voltage and current indication, 1600A Aluminium Busbar, 25x3mm Copper Earthing and 1500A Bus duct.
od289163/2019_2020 : Labour charges for Erection testing and commission of 500 KVA DG set
od289166/2019_2020 : Supply & providing plate earth station with 1200 x 1200 mm G.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, terminal electrodes etc., filling with alternate layers of charcoal and salt and back filling/ Earthing compound.The Earthing Station should confirm to IS 3043/1987. (Civil works not included)
od289239/2019_2020 : Supply & Laying, clamping at site of copper earthing conductors inclusive of providing earthing terminations and bracing of the terminations etc.
od289255/2019_2020 : Cable Laying Work: Supply, Laying, testing and commissioning of the following PVC /XLPE Insulated Armoured Aluminum L.T. Cables(AYWY/AYFY) through excavated trenches including supply and fixing of clamps, nuts and bolts, screws, identification tags etc. required for clamping intervals as necessary (all civil work/ cable trays not included)
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
od289266/2019_2020 : Supply and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required (25 mm)<br>12c 2.5 Sq. mm Cu cable
od289271/2019_2020 : Supply of Electrical ISI garde Rubber mat suitable for 440Volts switch boards( 6'x3'x1/2').
od289274/2019_2020 : Supply and fixing 25x3 mm tinned copper earth bus
1.1.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
od289281/2019_2020 : Supply and laying 2.5 Sq. mm copper wire through 20mm PVC conduit for circuit mains
od289289/2019_2020 : Supply and fixing 6x10 sintex junction box with connector
od289316/2019_2020 : Supply and Installation testing and commissioning of 415V, 500kVA DG- Prime Power limited(3B) (Stand-by with variable load, loading :< 75%, No. of operating hours : Max. Continous / year, 10% overload capability) Duty as per specifications, with radiator cooled engine. The suitable rating breaker to be mounted on alternator box for local isolation.
od289358/2019_2020 : Supply and Installation of Thermal insulation for 250mm dia pipes
od289359/2019_2020 : Supply and Installation of Exhaust pipe 8" suitable for 500kVA-DG,
od289361/2019_2020 : Supply and Installation of Sound attenuator on top of the exhaust pipe to reduce the exhaust noise
od289362/2019_2020 : Supply and Installation of Rain protection fins for the Sound attenuators
od289363/2019_2020 : Supply and Installation of Conventional type lightning arrest or with 2x25x3mm GI down conductors & 230V aviation lamps for exhaust support structure. The lamp shall be wired up to the exhaust support at ground level with outdoor class JB. The lightning down conductors shall be brought down & connected to merest earth grid.
od289364/2019_2020 : Supply and Installation of GI Steel items for supporting the exhaust pipes. These items shall be used for exhaust pipe supporting, silencer supporting etc.
od289365/2019_2020 : Supply and Installation of Aviation Lamp
DG Civil and Truss works
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.27 : Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete.
13.6.1 : 20 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
12.5.1 : Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limper and bitumen washers complete:1.60 mm thick with zinc coating not less than 350 gm/ m2
DG Foundation - Piping work for Cables
14.13.4 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required150 mm dia
Supply and installation of CCTV
od254151/2019_2020 : 4 MP 3.6 MM Lens 2688 X 1520 with junction box
od254172/2019_2020 : 4 MP IP PTZ Camera 30 X Zoom, 150 Meter IR Distance
od254179/2019_2020 : 16 Port POE switch with installation
od254184/2019_2020 : 08 Port POE switch with installation
od254188/2019_2020 : 32 Channel NVR with 2 HDD Port 200 Mbps
od254190/2019_2020 : Hard Disk - Internal- 6 TB - WD
od254192/2019_2020 : Optilink Optical Multiport - OLT
od254195/2019_2020 : Optilink - Optical Network Converter - ONU
od254201/2019_2020 : LG 43 Inch Full HD TV with Wall Mount Stand,Tvmounting bracket<br>and Installation Charges
od254208/2019_2020 : Dlink/ Unicorn 4 U Network rack with Power strip and cable tracker<br>and mounting
od254209/2019_2020 : Inverter 3 KV, 150 AH Battery 4 nos- Luminous
od254212/2019_2020 : Dlink/ Unicorn 17 Network rack , Trolly with Power strip and cable<br>tracker and mounting
od254221/2019_2020 : HDMI Cable 4K 10 meters
od254223/2019_2020 : Wireless mouse - Logitech
od254543/2019_2020 : Dlink CAT 6 LAN Cable - UTP
od254259/2019_2020 : Fiber optic coupler
od254264/2019_2020 : Fiber optic patch code
od254291/2019_2020 : Optical fibre cable 6 F with stay wire
od254293/2019_2020 : 2.5 mm 3 Core ISI UG Cable for power distribution to Hub at all floor including cabling charges
od254296/2019_2020 : Camera Installation & Testing
od254302/2019_2020 : Fiber optic cable splicing charges
od254305/2019_2020 : <br>20 MM ISI Evershine conduit can fittings and cabling accessories for CAT 6 and OFC Cabling charges with labour charge
2 Appendix- B Rising of RCC man hole cover,Drainage,Retaining wall and Foot path work
15.48 : Taking out C.I cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials with 50 metres lead as per direction of Engineer -in- Charge.
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
od254840/2019_2020 : Providing and fixing PVC pipes including jointing of pipes with one step PVC solvent cement , trenching, refilling for drain pipe etc complete as per the direction of Engineer in Charge. 150mm PVC pipe(6 kg/cm2)<br>
od255065/2019_2020 : Pavement on road surface using dry random rubble masonery including necessary earth work excavation as per the direction of Engineer-in-charge.
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
10.20 : Providing and fixing bolts including nuts and washers complete.
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
1 Appendix- A Surface improvement work of campus road around Hospital,Dental college and medical college blocks and BT patches
3.15.2 : Compacting Original Ground<br> (ii) Compacting original ground supporting subgrade<br> Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
3.2 : Preparation of Foundation for Embankment Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
75.5.5.B.2pb : Modified Penetration Macadam 75 mm thick using Bitumen S-65 - Packed Bitumen Rates <br> Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.,including supplying and stacking of materials.
75.5.5.A.1pb : Modified Penetration Macadam 50 mm thick using Bitumen S-65 - Packed Bitumen Rates <br> Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.,including supplying and stacking of materials.
75.5.1.1pb : Prime Coat - Low porosity - With Packed Bitumen Rates <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
75.5.2.3pb : Tack Coat - With Packed Bitumen Rates <br> Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
75.5.2.1pb : Tack Coat - With Packed Bitumen Rates <br> Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
75.5.9.1.2pb : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 - Packed Bitumen Rates<br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65),including supplying and stacking of materials.
75.5.12.A.3.2pb : Seal Coat - Manual Means - Type C - Bitumen S-65 - Packed Bitumen Rates <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means <br> Case III : Type C <br> (II) Bitumen (S-65),including supplying and stacking of materials.
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
1 Appendix- B Surface improvement work of campus road around Hospital,Dental college and medical college blocks and BT patches (items as per MortH Roads)
4.2.A.2 : Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. <br> Grading-IV - For lower sub base - Mix in Place Method <br>
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.3.2.a : Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder (VG 30), transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction.<br> For Grading II - (19 mm nominal size)<br>
5.6.2.a : Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder( NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects Grading - II (13.2 mm Nominal Size)<br>
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
8.35 : Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-
Parking
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
Bidder Name
H S OBEROI BUILDTECH PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid