Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹43.0 L
EMD Value
₹43,017
Closing Date
27 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Municipal Commissionar, Ahmedabad
REPLACEMENT OF EXISTING HYDRAULIC LIFT WITH SITC OF 01 NO.GEARLESS AND MACHINE ROOM LESS GOODS CUM 15/16 PASSENGERS LIFT B+G+1 AND SITC OF 01 NO. OF 15/16 PASSENGERS CUM GOODS LIFT B+G+1+2(WITH M.S. FABRICATED STRUCTURE) WITH 4 YEARS COMPREHENSIVE MAINTENANCE SERVICE CONTRACT AFTER DEFECT LIABILITY PERIOD OF 1 YEAR AT PANDIT DIN DAYAL AUDITORIUM, BODAKDEV AHMEDABAD
356004
2026-2027
Open
Miscellaneous Works
Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹1,500
Municipal Commissioner, Ahmedabad
₹43,017
16 Oct 2026
16 Oct 2026
16 Oct 2026
27 Oct 2026
16 Oct 2026
NAME OF WORK:- REPLACEMENT OF EXISTING HYDRAULIC LIFT WITH SITC OF 01 NO. GEARLESS AND
MACHINE ROOM LESS GOODS CUM 15/16 PASSENGERS LIFT B+G+1 AND SITC OF 01 NO. OF 15/16 PASSENGERS
CUM GOODS LIFT B+G+1+2 (WITH M.S. FABRICATION) WITH 4 YEARS COMPREHENSIVE MAINTENANCE SERVICE
CONTRACT AFTER DEFECT LIABILITY PERIOD OF 1 YEAR AT PANDIT DIN DAYAL AUDITORIUM, BODAKDEV
S.N. ITEM DESCRIPTION UNIT QTY UNIT COST
Supply ,installing , commissioning and testing of 15/16 Passengers,
Ground plus 2 upper floor (Basement + GF +FF) with Rated Speed of
1.0 m/sec., elevator (MRL LIFT) as per R & B S.O.R 26-27 item no - 13-
1 1-AP (C)) ( Category - Premium ) having following specifications:-
erection permission, Lift License, Inspection & Liaison fees and if
any in the scope of tenderer
Supplying, Erecting, Testing & Commissioning the passenger lift having
following main features:
[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift
A. C. Permanent Magnet Synchronous motor of proper rating with high
efficiency shall be used.
[2] Micro processor based / PLC, ACVVVF, vector control drive with
encoder feedback closed loop system shall be used for lift car and
door operation which shall be full collective selective operation hall call
demand response, UP/DOWN hall stops, Main, Up/ Down Contactor
with overload and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and to sustain
the impact load cabin + passenger with safety factor of fire for steel
and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be of anti skid PVC with choice of colour of
engineer in charge. Car doors shall be of stainless steel grade
hairline finish with centre opening / telescopic automatic doors. Car panel
will also be S.S. 304 finished with emergency stop device, mechanical
door safety device, facility of auto/ attended mode. All car panel
buttons and all floor switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall be fully
automatic centre opening/ telescopic opening made of hairline finish
steel grade of 304 with key holes and infrared curtains with Unlocking
facility from outside
[5] Appropriate battery operated emergency light in the car along with
alarm switch shall be provided. Also, Emergency Light & Fan should
start immediately without any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow along with
floor position indicator shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light
beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of
passenger capacity with Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing over loading shall be
provided such that doors kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer
shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters
shall be provided in control panel.
[14] Mechanical over speed governor with governor calibration as
per actual site parameters and submission of calibration certificate
submission, door key holes in the floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in the lift machine room and
monkey ladder for lift pit should be provided by the lift agency, along with
the other steel structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without any extra cost,
where ever required as / if directed by engineer in charge.
[17] Permanent wiring with necessary safety devices like RCCB in all
circuit, Over Voltage Under Voltage protection and THD eliminator in
circuit for lift machine room and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug points shall be provided
by the agency. Only 3 phase Power Supply shall be made available by
department in lift machine room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft
and machine room related to erection of lift shall be made by lift agency
without any extra cost. (granite/marble fixing around all landing door
openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents and
liaison services for obtaining all necessary permission from lift
inspector and other authorities. [20]
acrylic transparent licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat lift & escalator act
2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift erection and
provide report by third party authorized by concern licensing authority
5.agency has to provide third party insurance upto completion of free
maintenance period and submit the document for the same.
[21] Car Panel Operating Buttons with floor position indicator/buttons must
be of Auto Glow type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline
finish steel grade of 304 should be provided at appropriate height on the
Rear & Side Wall Panels in Lift Car.
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM
1. Advanced control system dual 64 bit embedded microprocessor with
CANBUS Serial Communication mode including Regenerative power
efficient operation,on site programming facility, Anti nuisance, Pte-
opening, BMS/RMS with necessary online real time monitoring system
having necessary connectivity for remote monitoring & other suitable
supporting hardware & software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail mark with
arrival gong and hall lantern & TFT Screen in the car with MP3 Voice
3. CAR Panel should be Scratch resistive SS Moonrock finish / Hair Line
/ Honeycomb for car and all Doors, All landing doors must have fire rating
up to 2 hours and car door must have multi-level crisscross beam door
4. To & fro communication system & wiring (i.e. car , control room & guard
room ) and Each elevator are equipped with remote monitoring
system.agency has to provide mobile app and user id and password for
15/16 Passengers, Ground plus 2 upper floor with Rated Speed of
(C) With General PLUS ADDITIONAL SPECIAL FEATURES attached
herewith. Prem. Cat. (SOR - 2026-27 - item no - 13-1-AP (C)) With
General PLUS ADDITIONAL SPECIAL FEATURES attached herewith.
Comprehensive Maintenance of the lift for 4 Years after
completion of DLP.
1 st year Job 1 65958
2 nd year Job 1 65958
3 rd year Job 1 75380
4 th year Job 1 84803
Supply, Installation, Testing & Commissioning of Passenger
Lift as per the technical specifications and conditions
mentioned herein.
15/16 Passengers, Ground plus 3 upper floor(Basement +
3 GF + FF + SF) with Rated Speed of 1.0 m/sec., No 1 2003064
26-27 SOR R & B* 13-1-AQ (C) With General PLUS
ADDITIONAL SPECIAL FEATURES as per R & B SOR - 26-
27 Item no - 13-1-AQ (Specifications as per Sr. No.-2)
Comprehensive Maintenance of the lift for 4 Years after
completion of DLP of Two year .
1 st year Job 1 70107
2 nd year Job 1 70107
3 rd year Job 1 80123
4 th year Job 1 90138
5 Existing Hydraulic lift Buyback Job 1 188450
Note :- Please note that floor/passengers calculation is done on the base of requirement, if any deviation in
floor/passengers (addition or substraction) then payment for SITC and comprehensive maintenance will be done
as per actual work done.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Technical Bid Vol-1.pdf
price bid.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .