Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | ₹16.4 L Quoted ₹18.8 L | L1 | Accepted-AOC AOC |
| 2 | L2₹26.7 L+₹7.9 L (42.0%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹26.7 L+₹7.9 L (42.0%) | L2 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
16 Nov 2022, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Repair/replacement of unserviceable parts of ceiling fan, Geyser and connected works at Rajouri and Naushera and repair/ maintenance of building lightning protection system and connected earthing at Rajouri under GE 862 EWS.
2022_MES_559105_1
GER-62/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 862 EWS
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹84,000
Yes
28 Nov 2022
21 Oct 2022
18 Nov 2022
21 Oct 2022
16 Nov 2022
4 Nov 2022
Amount
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts such as gasket of any type, nuts/bolts, clamp by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing, gas welding as required etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete. (Note:- Cost of gas welding, nuts/bolts, clamps, shall be deemed to be included in this item and indicating lamp, thermostate, heating element, bottom plate, flange assemble are measured and paid separately as supply only rates and fixing charges for the same shall deemed to be included in this item.)
Supply only Inner tank suitable for Geyser 25 to 35 Ltrs capacity (Apparatus assembly) made copper duly prewired of different make as approved by GE.
Supply only Inner tank suitable for Geyser 35 Ltrs capacity (Apparatus assembly) made copper duly prewired of different make as approved by GE.
Supply only Inner tank suitable for Geyser 50 Ltrs capacity (Apparatus assembly) made copper duly prewired of different make as approved by GE.
Supply only Indication lamp (Green/Red) as required.
Supply only Thermostat of range 60-90 degree centigrade as required (Make : Indofoss/Asian.
Supply only Heating element 1.5 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required.
Supply only Heating element 2 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required.
Supply only Heating element 3 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required.
S&F for PVC insulated and sheathed multi - staranded flexible wire 3 core with Copper conductor 2.5 Sqmm round type for Geyser. (Make : Finolex/Nicco/KDK/Havells)
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm to 600mm long for hot/cold water as in repair.
S&F for geyser syphon assemble chromimum plated suitable for 50 ltr capacity geyser as in repair.
S&F for geyser syphon assemble chromimum plated suitable for 25/35 ltr capacity geyser as in repair.
S&F for industrial plug and socket board with 20 Amp MCB with sheet metal enclosure and plug top complete as in repair. (Make : HPL, Cat No DBSP 20 or equivalent of Indoasian/Anchor)
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of bush, bearing and marking MES number ass as directed by Engr-in-Charge. (Note:- Bush, bearing are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in this item.)
S&F for upper/lower canopy of 1200/1400mm sweep ceiling fan(as per sample colour/white) complete as in repair all as specified and directed.
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. Make of copper winding wire shall be Hindustan/Atlas (Note :- twin twisted copper cable is measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in this item).
S&F for Condenser 2.5/3.15 MFD. (metal body)(Make : Universal/Sarda)
S&F for Condenser 4 MFD. (metal body)(Make : Universal/Sarda)
S&F for twin core twisted copper flexible wire/cable of size 1.5 Sqmm, 3 Core. (Make : Finolex/Nicco/KDK/Havells)
All as per Item No.17 here-in-before but exhaust fan of size 300 mm sweep.
All as per Item No.17 here-in-before but exhaust fan of size 450 mm sweep.
S&F for fan blade set of 1200/1400mm sweep ceiling fan (as per sample colour/white) complete as in repair all as specified.
M&L for overhauling & servicing the solar water heater 100 litre capacity by repair/replacing the spares of any type i.e anode, gasket set, solar cell, solar panel glass etc, and blocks in the solar cells removed by the acid cleaner and damaged solar cells to be replaced including replacement of unserviceable/damages part complete all as specified and directed. Note:- Supply only spares will be measured & paid separately).
Supply only Anode for solar water heater 100 Ltr capacity as per sample.
Supply only Gasket set for solar water heater panel suitable for 100Ltr capacity as per sample.
Supply only solar panel glass suitable for 100 ltrs capacity solar water heater with gasket of approved make & tested completeas per sample.
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 100 Ltr capacity as per sample.
S&F for PCB for control unit for sensor of ceiling fan as per existing and same make all as in repair .
S&F for remote of ceiling fan with batteries control for any type complete as in repair all as specified and directed (Make : as per existing)
S&F for 300mm long air termination, single pointed, aluminium rod of 12mm dia on the highest point of buildings or as required at site on porcelain base support complete after taking down old unserviceable aluminium air termination rod all as specified and directed
S&F for 300mm long air termination, single pointed, copper rod of 12mm dia on the highest point of buildings or as required at site on porcelain base support complete after taking down old unserviceable copper air termination rod all as specified and directed
S&F for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass screw housed in FRP box duly locking arragement including connecting down conductor and eath strip/wire after taking down old unserviceable test point terminal block complete all as specified and directed.
S&F for 25x3.15mm Aluminium strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable aluminium strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the aluminium strip comes in direct contract with pole. 2. aluminium strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
S&F for 20 x 3.15mm Copper strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable copper strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the copper strip comes in direct contract with pole. 2. copper strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
S&F for32x6mm galvanised iron strip with saddles and fixing screws etc. for roof conductors and down conductors above ground of any type of wall surfaces with necessary fixing arrangment by providing porcelaing base at 60cm inter bal and using cadmium plated fixing screw and insulator par running meter all as required at site complete after dismantling of old unserviceable galvanised iron strip all as specified and directed. (Note:- 1. Strip will be installed on saddles in such a way that in no case the copper strip comes in direct contract with pole. 2. copper strip will be fixed epoxy base insulators of suitable size and rates were deemed to be included in quoted prices).
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. (Note:-Earth wire and protection pipe upto board is included in the rate quoted)
M&Lfor earthing complete with copper earth plate electrode 600x600x3.15mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 20x3 thick copper strip for from earth electrode to test point/ equipment of upto 7.5 m whichever is less by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto test point/equipment upto 7.5m is included in the rate quoted)
M&Lfor chemical earthing pit with copper earth plate of size 900mm x 600mm x5mm thick buried directly in ground vertically to a depth not less than 4m below normal ground level, connected to & including 32 x 6 mm copper strip by means of nuts, bolts check nuts and washers made of copper and connected to test point including brazing and excavation and earth work in any type of soil, with charcoal 250 Kg, crystal salt 200 Kg, magnesium sulphate of 100 Kg and vegatable soil all around the plate 35 cm depth bottom to top of the plate full width of pin including PCC 1:3:6 type C1 in chamber of internal size 300mm x 300mm x 300mm with wall thick ness of 120mm and 700mm x 700mm x 150mm bed concrete, precast PCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/Sqm) with cast iron frame, funnel, with wire mesh, 25mm bore medium grade GI pipe, lugs, 80mm bore medium grade GI protection pipe, test point etc complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5m is included in the rate quoted)
M&L for 40mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, lightening protectioncrossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, lightening protection, crossing of roads, laid in trenches, fixed on walls for protection complete all as specified and directed.
M&L for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles complete all as specified and directed.
S&F for erath continity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as requuired 4mm dia galvanized iron or steel wire and removing old unserviceable wire complete all as speicified and directed
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Chib Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .