Loading…
Loading…
Tender ID
Tender Value
₹6.5 Cr
EMD Value
₹6.5 L
Closing Date
6 May 2026, 6:00 pmClosed
Executive Engineer, R&B Division, Anand
Construction of New Mamlatdar Office Building at Sojitra, Dist.-Anand
295975
27 of 2025-2026 (Sr. No.04)
Open
Civil Works - Buildings
Works
Anand
1 document required · 1 mandatory
₹12,000
Executive Engineer, R&B Division, Anand
₹6.5 L
10 Apr 2026
10 Apr 2026
10 Apr 2026
6 May 2026
10 Apr 2026
Item No. Brief Description of Qty.of Prescription of test which shall Frequency@ which test Total No. of
as per Materiais to be tested Materiai be carried out shaii be carried out Test to be
Sch. B carried out
Coarse Aggregate -
Gradation test 1 to 100 Cum — 1 test
Impact Value 100 to 500-3 tests
Gravel etc.) Flakiness Index 500 to 1500 5 tests
Water absorption 1500 to 5000 7 tests-
Grit Stri Value One test work
Sand Gradation One test per 150 Cum or as
Fineness Modulus per requirement of relevant
Specific gravity specification
Water absorption
Ties Dimension Test One test per 2000 tiles
Transverse strength
Water Absorption
Teakwood Anatomy Test One test per work
Moisture Content Test
Dimension and tolerance
@ 50,000 Bricks
Water absorption
Com ressive Stren
Cement Consistency Up to 50 MT 1 Test
Setting Tme 50 -100 MT 2 Test
Compressive Strength 100 200 MT
Fineness 200 300 MT
Chemical analysis 300 500 MT
Soundness 500 800 MT
800 -1300 Mt 7 Test
and 8 test for larger
Steel Tensile Strength One test/40 tonnes/per
Yield Stress category
C.C. Cube test 1 -
Compressive Strength 1 to 5 Cum. 1 Test.
6to 15 Cum. 2 Test.
16 to 20 Cum. 3 Test.
21 to 50 Cum. 4 Test
& Above Cum.4 + 1 for
each additional 50Cum or
Aluminum Sections -
Gau e Section One Test for each section
Testing Charges shall be born by Govt. No refund be made or extra charge over 1 % shall be recoverable
form the contractor.
SIGN OF CONTRACTOR EXEC VE ENGINEER
General Specifications
70H Lubi make main fire pump with necessarywiring,installation, commissioning &
30HP/70H Lubi make main fire pump horizontal monoblock type 900LPM / 2800RPM at
fiow range:up to 156m3/h
head range:up to 70mtr.
ambient temperature:max. +50c.
liquid tem. range:OC to +90c.
RATING:3 PHASE -
ENCLOSURE CLASS:lP55.
VOLTAGE:415V. 3 PHASE.
THREE PHASE MOTORS MUST BE CONNECTED TO A AUTO CONTROL PANEL ACCORDING TO
LOCAL REGULATION.
7.5HP/70H Lubi make vertical jockey fire pump with necessary
wiring,installation,commissioning & Accessories.
7.5HP/70H Lubi make vertical jockey fire pump 450LPM/2800RPM at 4.8kg/cm2.
flow range:up to 128m3/h
head range:up to 70mtr.
ambient temperature:max. +50c.
liquid tem. range:OC to +90c.
RATiNG:3 PHASE - 2.2 TO 12KW.
ENCLOSURE CLASS:lP44.
VOLTAGE:415V. 3 PHASE.
THREE PHASE MOTORS MUST BE CONNECTED TO A AUTO CONTROL PANEL ACCORDING TO
LOCAL REGULATION.
49HP Lubi make Diesel fire pump with necessary wiring,installation,commissioning&
pump 25hp 70mtr. Head 2800rpm/800LPM, end suction 66psi.
SUCTION SIZE:125MM.
DELIVERY SIZE:IOOMM
NOMINAL IMPELLER DIA.:250MM.
DISCHARGE RANGE:IOO TO 1250USGPM.
HEAD RANGE:5.24 TO 20.61 BAR.
FLBS FIREPUMPSET SHALL BE USED ONLY WHERE A POSITIVE SUCTION IN PROVIDED
Combined auto control panel with all necessary wiring(L & T or Siemens) with installation
MODEL NO LFY:380 / 50KW.
HP/KW RATING:50/50KW.
FREQUENCY: 50HZ.
Pressure Switch
IP RATING: IP46
FREQUENCY: 40-50 Hz
SURFACE FINISH:COATED
VOLTAGE:200-220V
(7 Pressure Gauge grycerilled filled upto 21kg pressure.
Pressure Gauge grycerilled filled upto 21kg pressure.
ACCURACY: +/- 0.25%
MiN OPERATiNG TEM.:-4F / -20C.
MAX OPERATING TEM.:122F / 50C.
WEITED MATERIALS:316SS
WEIGHT:12.6 OZ/ 355GRAMS.
CERTIFIED TO CSA STANDARDS C22.2 NO.61010-1.
Non return valve(DCV type)-100mm
Non return valve(DCV type) with SS disc as per IS;5312 ISI marK
RATING:JIS 150# TO 10 TO
BODY:CARBON STEEL (A216-WCB)
DISC:STAINLESS STEEL
SPRING:STAINLESS STEEL (304)
Non return valve(DCV type)-150mm
Non return valve(DCV type) with SS disc as per IS;5312 ISI marK
RATING:JIS 150# TO 10 TO
BODY:CARBON STEEL (A216-WCB)
DISC:STAINLESS STEEL
SPRING:STAINLESS STEEL (304)
Butterfly valve-80mm
Butterfly valve with SS disc as per
IS;5312 ISI mark
BODY:CARBON STEEL (A216-WCB)
DISC:STAINLESS STEEL
Butterfly valve-IOOmm
Butterfly valve with SS disc as per
IS;5312 ISI mark
BODY:CARBON STEEL (A216-WCB)
DISC:STAINLESS STEEL
Butterfly valve-150mm
Butterfly valve with SS disc as per
IS;5312 ISI mark
BODY:CARBON STEEL (A216-WCB)
DISC:STAINLESS STEEL
Foot valve-100mm-NORMAX(Ball Type)
Foot valve-IOOmm-NORMAX(Ball Type) with SS disc as per IS;5312 ISI mark
BODY:CAST IRON -
IS210,FG200 MIN.
STRAINER: CAST IRON -
IS210,FG200 MIN.
BALL: NITRILE RUBBER COATED.
SEATRING: NITRILE ASTM D2000L.T.
FASTENER: CARBON STEEL CL4.
RATING(KPA): PN
Foot valve-150mm-NORMAX(Ball Type)
Foot valve-150mm-NORMAX(Ball Type) with SS disc as per IS;5312 ISI mark
BODY:CAST IRON IS210,FG200 MIN.
STRAINER: CAST IRON IS210,FG200 MIN.
BALL: NITRILE RUBBER COATED.
SEATRING: NITRILE ASTM D2000L.T.
FASTENER: CARBON STEEL CL4.
RATING(KPA): PN
Fire Hose (IS 903) 15M TR with SS/GM male female(lSl) coupling ISI approved, Heavy duty.Make-SHAH
BHOGILAL/KARTAR/ -
All synthetic fiber circular woven jacketed, EPDM synthetic REINFORCED RUBBER LINED (RRL) delivery
Dia. 63mm X 15mtr length,
- Working Pressure 14kg/cm2, Proof Pressure 22kg/cm2, Burst Pressure 38kg/cm2,
BEARING IS: 636-1988 TYPE A, ISI MARK, CE MARKED,
Dully fitted with Hose Coupling made of SS 304, Pair of male & female parts, Instantaneous Pattern,
Size: 63mm X 63mm, bearing IS: 903 ISI mark, SS wire binding,
Dia. 63mm X 15mtr length,
Working Pressure 14kg/cm2, Proof Pressure 22kg/cm2, Burst Pressure 38kg/cm2,
BEARING IS: 636-1988 TYPE A, ISI MARK, CE MARKED,
Dully fitted with Hose Coupling made of SS 304, Pair of male & female parts,
Instantaneous Pattern, Size: 63mm X 63mm, bearing IS: 903 ISI mark, SS wire binding,"
Fire Hose Box double door heavy duty bombeytype(18 gauge box ) SHAH
BHOGILAL/NEWAGE- Made of 18 gauge Mild steel,
- Suitable to accommodate 02 Nos. of 15mtr. length of (Type-A) delivery hose and 01 no. branch pipe,
Double door with Acrylic fittings (2.5 MM Thickness), with lock, two keys and a break glass recess for
Painted Fire Red outside and White inside
Suitable to accommodate 02 Nos. of 15mtr. length of (Type-A) delivery hose and 01 no. branch
Double door with Acrylic fittings (2.5 MM Thickness), with lock, two keys and a break glass recess
Painted Fire Red outside and White inside"
Fire hose reel 25MM with Drum 30 MTR with GM shut off nozzle ISI approved MakeSHAH
Drum complete with wall mounting bracket,
Complete with 25mm bore X 30mtr long.
Fitted with 6mm bore Stainless Steel
shut-off nozzle
Without Inlet Valve
GENERALLY CONFORMING TO IS: 884 MUST BE FITTING WITH UNION JOINT & BALL VALVE
Fire hose reel 25MM with Drum 30 MTR with GM shut off nozzle
Drum complete with wall mounting bracket,
Complete with 25mm bore X 30mtr long.
Fitted with 6mm bore Stainless Steel shut-off nozzle
Without Inlet Valve
GENERALLY CONFORMING TO IS: 884 MUST BE FITTING WITH UNION JOINT & BALL VALVE
Fire hydrant valve(Extra heavy duty) SS/GM ISI approved(lS 5290) make- Make-SHAH BHOGILAL/
NEWAGE/KARTAR/ZOLOTO Body / female inst. Oblique outlet (63mm size)
with Pull out type Lug made of Stainless Steel, IS: 3444 Gr-
75mm N.B. Flanged inlet,
Spindle made of S.S. (IS: 6603) and Hand wheel made of Cast Iron,
Complete with PVC blank cap & chain,
BEARING IS: 5290 MARK,
Flange Dimension: O.D. 200mm, PCD 160mm, four 19mdia holes
- 75mm N.B. Flanged inlet,
Spindle made of S.S. (IS: 6603) and Hand wheel made of Cast Iron,
- Complete with PVC blank cap & chain,
BEARING IS: 5290 MARK,
- Flange Dimension: O.D. 200mm, PCD 160mm, four 19mdia holes"
Branch pipe (Heavy duty)SS/GM ISI approved Make- SHAH BHOGILAL/NEWAGE/
Made of Stainless Steel -
Having 63mm Male Inst. Inlet, Male Threaded Outlet, fitted with 15mm bore nozzle,
BEARING BIS: 903 MARK
Having 63mm Male Inst. Inlet, Male Threaded Outlet, fitted with 15mm bore nozzle,
- BEARING BIS: 903 MARK"
Four way inlet SS/GM heavy duty
TEST PRESSURE:21KG/CM2
BODY: GUN METAL
SIZE: 150MM FLANGE
Ball valve 25mm heavy duty with nipple(two) & other fitting material Matrix
MATERIAL:BODY-FORGED BRASS,CHROME FINISH,STEM- BRASS.
TEST PRESSURE:24KG/CM2.
GI pipe C grade-150mm
Nominal Bore in mm Outeside
Maximum -166.50 ,Minimum =163.90
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) =
GI pipe C grade-IOOmm
Nominal Bore in mm Outeside
Maximum =115.00 ,Minimum =113.10
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) -12.50
GI pipe C grade-80mm
Nominal Bore in mm Outeside
Maximum =89.50 ,Minimum =88.50
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) =8.53
GI pipe C grade-50mm
Nominal Bore in mm Outeside
Maximum =60.80 ,Minimum =59.70
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) =5.10
GI pipe C grade-32mm
Nominal Bore in mm Outeside
Maximum =42.90 ,Minimum =42.00
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) =3.13
GI pipe C grade-25mm
Nominal Bore in mm Outeside
(7 Maximum =34.20 ,Minimum =33.30
Thikness In mm =
Mass of screwed & Siketted tube (kg/m) =2.43
Sprinkler UL & FM Listed
NOMINAL K FACTOR: 5.6(U.S.)
FACTORY HYDROTATIC
@ 500PSlG / 3.4MPA (34BAR)
MIN. OPERATING PRESSURE:7PSlG ,O.048MPA
SPRINKLER FINISH:NATURAL PLATED,WHITE COLOR COATED.
Smoke detector(Approx)
weight:127grams
operating humidity range:O t095% RH non-condensing
input terminal:14 t022AWG
POWER UP:BLINK EVERY IOSECONDS
OPERATING NON POLARIZED
Hooter Wall mounting type output sound level;100db.(adjustable by inbuilt volume cotrol)r
SYSTEM OPERATING VOLTAGE:24VOLT DC
SOUND PRESSURE LEVEL:90DB AT 25MTR.
FREQUENCY TO IOOOHZ)
ALARM CURRENT:200MA-PEAK
OPERATING TEM:IOC TO 42C.
WEIGHT:350GRAMS.
PROTECTION TYPE:lP65
MCP EN 54-11 standard CE-CPR approved 5 A -24 -RAL
MCP (MANUAL CALL POINT) EN 54-11 standard CE-CPR approved 5 A -24 -RAL
OPERATING VOLTAGE:15-30VOLT DC
ALARM CURRENT:7.8MA OUTDOOR 7.6MA
MATERIAL:PC/ABS
CERTIFIED TO EN54.11
SUITABLE FOR AS1670.1 INSTALLATION
OPERATING TEMPERATURE: indoor oc to 49c. outdoor -25c to 70c.
Fire alarm panel -IOC TO 60C HUMIDITY ; 10% TO 93% 230V 50hz 2.5A 2 X 12V 12ah.
Fire alarm panel -IOC TO 60C HUMIDITY ; 10% TO 93% 230V 50hz 2.5A 2 X 12V 12ah.
DIMENSION(H X W X X 422 X 122.8MM.
WEIGHT: 3KG (APPROX).
CABLE ENTRY:15 X 20MM KNOCKOUT.
OPERATING TEM.:O TO 49C.
OPERTING VOLTAGE:230V-ZC +/- OUTPUT CURRENT 2A
STANDBY BATTERIES: MINIMUM CAPICITY 2 X 12V 2.8AH.
MAXIMUM CAPICITY 2 X 12V 7AH.
1.5sqmm/02 core cable is;1554 1988 CM/L NO.81579 82..
1.5sqmm/02 core cab!e 1988 CM/L NO.81579
1.1 TYPE 1.5SQMM MULTISTRAND (24/0.2MM), HIGH CONDUCTIVITY.
COPPER CONDUCTOR 650/1100V GRADE,PVC INSULATED,PAIR TWISTED & SCREENED OUTER FRLS
PVC SHEATHED WITH PROPER PAIR IDENTIFICATION.
ABC type new FE — 06 kg (3 years warranty)
ABC Type New FE 3A 89B -30C TO +60C, 55/80 BAR MIN. MAP
THROW OF JET MAINTAINED:20SEC.
MINIMUM PERIOD TO DISCHARGE:25SEC.
EMPTY WT.:2.8KG.
FULL WT.: 8.8KG.
WORKING PRESSURE:15KG.
HYDRO PRESSURE :35KG.
BRUSTING PRESSURE:55KG.
KENEX/SAFE GROW
C02 type new FE -
4.5KG (CCOE APPROVED & 5 YEAR WARANTY)
CAPIClTY:4.5KG.
C02 GAS AS PER IS
FIRE RATING:13B.
WORKING TEM.:-IOC TO +55C.
CYLINDER TEST PRESSURE:250BAR.
FILLING RATIO:O.687.
MINIMIM EFFECTIVE DISCHARGE TIME:8SEC.
BULK RANGE DISCHARGE:IMTR.
OPERATING PRINCIPLE:AS PER IS
KENEX / SAFE GROW
Specifications for Electrical Works in Government Building
Subject to the General condition of Contract in force (1986) General
The installation generally shall be carried out in conformity with relevant Indian standard.
Specification of and code of practices pfevaient, indian Eiectficity Ruies, 1956 and indian
Electricity Act. 1910 as amended from time to time.
2. Definition :
The definition of terms shall be in accordance with Indian standard code of Practice for
Electrical wiring installation IS-732-1982 except for the definition of point in case of internal
Electrical Installation. For definition of point wiring and measurement of Electrical works IS-
5908-1970 shall be referred to.
3. Voltage and Frequency of supply :
All current consuming devices shall be suitable for frequency of 50C/s and systems of
voltage manual for unless otherwise specified.
4. Layout of wiring and its description :
per schedule "Power" wiring must be
(i) The wiring shall be carried out as in screwed
conduit and shall be kept separate and distinct from lighting wiring. All wiring must be done on
the distribution system with main and branch distribution boards at convenient centers and
without isolated fuses. All conductors shall be run as far as possible along the walls and ceiling
as to be easily accessible and capable of being thoroughly inspected. The balancing of circus
will be arranged before hand by the Ex. Engineer Electrical Division.
(ii) Within one month of the taking over the installation, the contractor shall supply to the
Ex. Engineer Elect. Division a complete set of wiring diagrams of the same on drawings to be
supplied when available by the Executive Engineer Electrical Division and to the satisfaction of
the Ex. Engineer, Elect. Dept. and these wiring pains shall be "Drawings" within the meaning of
the term as used in the General conditions of contract.
5. Conductors :
All conductors unless otherwise specified shall not be less than 1.5 sq. mm. for point
wiring and 2.5 sq. mm for mains conductors for power and lighting circuits shall be adequate
size to carry the designed circuit load without exceeding the permissible thermal limits for the
installation, and such sizes will be stipulated in specifications and or drawings.
6.1 All cables shall conform to relevant Indian Standards.
6.2 Conductors of all cables except the flexible cable shall be of alluminium. The smallest
aluminum conductor for the final circuit shall have nominal cross sectional area of not less than
1.5 sq. mm. The minimum size of the aluminum conductors for power wiring shall be 4 sq. mm.
6.3.1 Conductors of flexible cables shall be of copper the minimum cross sectional area of
such a cables shall be 14.0193 mm. the Flexible cable shall have uniform and adequate
6.3.2 Unless the flexible cables and conductors are protected by armounr or though rubber of
PVC Sheath, theses shall not be used in workshops and other places where they are liable to
mechanical damage.
6.3.3 Core flexible cables shall be used for connecting single phase Appliances or phase,
natural & earth connections.
Fall of Potential :
The Cross sectional area of all conductors inside buildings shall be so proportioned to
their lengths that the drop in voltage between main fuses and the farthest point or any lamp
shall not exceed three percent of the voltage of the consumer'swith all the consuming devices
7.1 If the Cable Size is increased to avoid the voltage drop in circuit
current rating of the
cable shall be more than that for which circuit is designed. In each circuit or sub circuit or sub
circuit every cable shall have current higher than the full load current.
8. Ratings of lamps and fans socket outlets : Points and exhaust fans
8.1 Incandescent lamps installed in residential and non-residential building shall be rated at
60 watts & 100 watts respectively.
8.2 Table fans and ceiling fans shall be rated at 60 watts, exhaust fan shall be rated at
watts and 1000 watts respectively for the purpose of load assessment unless actual values of
the load are, know or specified.
9.1 Before the installation is commissioned following tests shall be carried out.
Insulation Resistance Test.
(2) Polarity Tests of Switches
Earth continuity tests
(4) Earth electrodes Resistance test.
9.2.1.1 The insulation Resistance shall be measured between earth and the whole
system of conductors or any section there of with all fuses in place and all switches close, and
except in earthed concentric wiring all lamps in position or both poles of installation otherwise
electrically connected together. A direct current pressure of not less than the twice working
pressure provided that it need not exceed. 500 volts for medium voltage circuits where the
supply is derived from three wire D.D or a ploy phase A.C. system, the neutral pole of which is
connected to earth either direct or through added resistance, the working pressure shall be
deemed to be that which is maintained between the phase conductor and the neutral.
9.2.1.2 The insulation sentence shall also be measured between all conductors to one
pole or phase conductor of the supply and all the conductors connected to the neutral or to the
order pole or phase conductors of the supply with all lamps in position and switches in "OFF"
position and its value shall be less than specified in sub-clause 9.2.
9.2.1.3 The insulation resistance in Mega-ohms measured as above shall no be less
than 50 mega ohms divided by the number if outlet or when PVC insulated cables are used for
mega ohms divided by number of outlets.
9.21.4 Where a whole installation is being tested a lower value than that given by the
formula subject to a minimum of 1 mega ohm is acceptable.
9.2.1.5 A preliminary and similar test may be made before lamps, ect., are installed and
event the insulation resistance to earth should be not less than 100 mega ohms divided
by the number of outlet or when PVC insulated cables
are used for wiring 25 mega ohms
divided by number of outlets.
9.2.1.6 The term "Outlet" includes every switch except that a switch except that a switch
combined with a socket outlet appliance or lighting, fitting is regarded as one outlet.
9.2.1.7 Control rheostat heating and electric sign may, if required, be dis-connected from
the circuit during the test, but in that event the insulation resistance between the case or frame
work, and all live parts of each rheostat, appliance and sign, shall be not less than that specified
in the relevant Indian Standard Specification
or where there is no such specification Sha!! be not
less than half a
9.2 Polarity Test :
9.2.2.1 In a two wire installation a test shall be made to verify that all
switches in every
circuits have been fitted in the same conductor through out & such conductor shall be labeled or
marked for connection
to the phase conductor or to the non-earthed conductor of the supply is fitted in a conductor
which is labeled or marked for connection to one of the phase conductor of the supply.
9.2.2.2 In a three wire or a four wire installation a test shall be made to verify that
non-linked single poie switch is fitted in a conductor which is labeled or marked for connection to
one of the phase conductor of the supply.
9.2.2.3 The installation shall be connected to the supply for testing. The terminate of all
switches shall be tested by a teat lamp one lead of which is connected to the earth. Glowing of
test lamp to Us full brilliance when the switch is in on position irrespective of appliance in
position or not shall indicate that the switch is connected to the right polarity.
9.2.3 Earth Continuity Test :
The earth continuity conductor including metal conduits and metallic envelops of cables
cases shall be tested for electric continuity and the electrical resistance of the same along
with the earthing lead but excluding any added resistance or earth leakage circuit breaker
measured form the connection with the earth electrode to any point in the earth continuity
conductor in the completed installation shall not exceed one ohm.
9.2.3.1 Earth D!ectrode Resistance Test :
Earth electrode Resistance test may be carried out by magger Earth Testers containing
a direct reading ohmmeter, a hand driven generator and auxiliary electrodes.
9.3 On completion of an electric installation (addition and alteration) a certificate shall be
furnished by the contractor countersigned by the certified Supervisor under whose direction
supervision the installation was carried out. This certificate she!! be in the prescribed form as
given in Appendix-B in addition to the test certificate required by Local Electrical Supply
10. Joint and looping back :
Unless with the sanction of Ex. Engineer, Electrical Divisions all joints in conductor shall
be means of approved mechanical connectors in suitable and approved junction boxes but
!ooping back system Sha!! be preferable. in wiring unless otherwise specified phase and live
conduct shall be looped at the switch box where a neutral conductor can be looped form light,
fan or socked in non-residential buildings neutral and earth continuity wire shall be brought to
each of 'the switch boards should be of adequate size to accommodate at least one number of
Amps, socket outlet and control switch in future.
Main Switchgears, Switch Board and their location .
main switches (other hart lose of iron clad pattern) carrying current of IO Amp. and
above shall be twitted for back connections and shall be suitable protected.
11.2 AH switches and circuit breakers shall be constructed in accordance with the I.S. 4237-
1967. General requirement for switchgear and conrtol gear for voltage not exceeding 1000 volts
and other relevant I.S. provided also that spring shall be either of phosphor bronze or if steel
Sha!! be copper or Nicke! plated and that handle Sha!! the so fastened that they do not tend to
01 become boss.
11.3 All main switches shall be either of metal cad enclosed pattern of any insulated enclosed
pattern which shall be fixed at close proximity to the point of entry of supply.
11.4 Switch boards shall net be erected above gas, stoves, or within 2.5 mm of any washing
washing rooms of laundries or in the bath rooms, lavatories, toilets or kitchens.
11.5 Switch boards, if unavoidably fixed in places likely to be exposed to weather, to drip or to
abnormal moose temperature the outlet casing shall be weather proof and shall be provided
with glands or bushing of adopted to receive screwed" conduit according to the
manner in which
cables are run P/C and double flanged bushes shall be fitted in the holes of the switches for
entry and exit of wires.
11.6 A Switch board net he installed so that its bottom is within 1.25 mm above the floor
unless the front of the switch board completely enclosed by a door or the switch board is
located in a position to which only authorized persons have access.
11.7 Switch boards shall be recessed in the wall if so specified in the schedule of work or in
the special specification. The front shall be fitted with hinged panel of other suitable
material such as bakelite in wood frame with locking arrangement, the buts surface of
door being flush with the walls. Ample room shall be provided at the back for
connections and at the front between the switchgear mountings and the door.
11.8 Equipments which are on the front of a switch board shall be so arranged that
inadvertently personal contact with live parts in unlikely during the manipulation of
switchgears. changing of fuses or like operations.
11.9 No holes other than the holes by means of which the panel is fixed shall be drilled closer
than 1.3 from any edge of the panei.
11.10 The various live parts, unless they are effectively scroended by substantial barriers of
non hydroscopic, nomiammbale insulating material, shall be so spaced that space shall
not be maintained between such parts and earth.
11.11 The arrangement of gear shall be such that they shall be readily accessible and their
connections to all instruments and apparatus shall also be traceable.
every case in which switches and fuses are fitted on the same pile, these fuses shall
be so arranged that the fuses are not alive when their respective switches are in the off
11.13 No fuses other than fuses in instrument circuit shall be fixed on the back of or behind a
switch board panel of frame.
11.14 All the metal switchgears and switch boards shall be painted, prior to erection with one
coat of antiruse primer, After erection they shall be painted with two coats of approved
enamel or alluminium paint as required on all sides wherever accessible.
11.15 All switch boards connected to medium voltage and above shall be provided with
"Danger Notice Plate" conforming to relevant Indian Standards.
12. Control at Point of Commencement of Supply :
12.1 There shall be a linked man switchgear with fuse on each live conductor of the supply
mains at the point of entry. The wiring through out the installation shall be such that
there is no break in the natural shall also be distinctly marked. In this connections Rule
32(2) of the Indian Electricity Rules, 1966 (See Appendix-A_ shall also be referred.
12.2 The main switchgear shall be situated as near as practicable to be termination of
services line and shall be easily accessible without the use of any external aid. o
12.3 On the main switchgear, where the conductor of a two wire system or any earthier
neutral conductor of a multi wise system or a conductor which is to be connected
thereto, an indication of a permanent nature Shal! be provided to identify earthier neutral
conductor. In this connection Rule 32(1) of Indian Electricity Rules, 1956 (see appendix
'A') shall be referred.
13. Switch Board & Distribution Boards :
I Metal clad switch gear shall preferably be mounted on any of the following types of
13.1 Hinged type Metal Board :
There shall consist of a box made of sheet metal not less than 2 mm thick and shall be
provided with a hinged cover to enable the board to swing open for examination of the
wiring at the back. The joints shall be welded. A teak wood board, thoroughly protected
both inside and outside with good insulating varnish conforming to
IS : 347-1952 specification for varnish sheiac for General
purpose and of not less than
6.5 mm thickness shall be provided at the back for attachment of incoming and outgoing
cables. There shall be a clear distance of not less than 2.9 cm between the teak wood
board and the cover, the distance being increased for larger boards in order that on
closing of the cover, the insulation of the cables in not subjected to damage and no
shoat length of cables is subjected to excessive twisting or bending
any case. The board shall be security fixed to the wall by means of rag bolts, plugs or
wee den Gut ties and shall be provided with a locking arrangement and an earthing stud.
All wires passing through the metal board shall be bunched. Alternatively, hinged type
metal boards shall be made of sheet covering mounted on channel or angle iron frame.
Note : Such type oi boards are particuiariy suitabie for smaii switch-boards for mounting metai-
clad switchgear connected to supply at low voltages.
13.2 Fixed type Metal Boards :
These shall consist of an angle or Channel of iron frame fixed on the wail or on floor and
supported on the wall at the top if necessary. There shall be a clear distance of one
metre in front of the switch board. If there are attachments of base connections at the
back of the switch board Rules of indian Electricity Rules, 1956 shaii apply
NOTE : Such type of boards are particularly suitable for large switchboard for mounting large
number of switchgears or higher capacity metal clad switchgears of both.
13.3 Teak wood Boards :
For small installation connected to a single phase 230 volts suppiy teak wood boards
may be caused as main boards or sub-boards. These shall be of seasoned teak or other
durable wood with solid back impregnated with varnish of approved quality with all joints
medium voltage installations,
before proceeding with the actual construction
of the boards proper drawing showing the detailed dimensions and design including the
disposition of the mounting a which shall be symmetrically and neatly arranged for
arriving at the overran dimensions Sha!! be prepare and approved by the engineer-in-
13.5 Recessing of Boards :
Where so specified the switch boards shall be recessed in the wall. The front shall be
fitted with a hinged panel of teak wood or other suitable materials, such as bakelite, or with
unbreakable glass doors in teak wood frame with locking arrangement, the other surface off the
doors being flush with the walls, ample room sha!l be provided at the back for connection and at
the front between the switchgear mountings.
13.6 Arrangement of Apparatus :
a) Equipment which is on the front of a switch board shall be so arranged that inadvertently
personal contract with live parts is unlikely during the manipulation of switches, changing
of fuses or like operation.
b) Nc apparatus she!! project beyond any edge cf panel. No fuse body Shal! be mounted
within 2.5 cm of any edge of the panel and hole other than holes by of which
the panel is fixed shall be drilled closer than 1.3 cms from any edge of the panel.
c) The various live parts unless they are effectively screened by substantial barriers of non-
hydroscopic, non inflammable insulating material, shall be so spaced that an are cannot
maintain between such parts and earth.
d) The arrangement of the gear shall be such that they shall be readily accessible and their
connections to e}! instruments and apparatus Sha!! be so spaced that an ere cannot
maintain between such parts and earth.
The arrangement of the gear shall be such that they shall be readily accessible and their
connection to all instruments and apparatus shall also be easily traceable.
case in which switches and fuses are fitted on the same pole, these fuses shall
be so arranged that the fuses are not alive when their respective switches are in the
'OFF' position.
g) No fuses other than fuses instrument circuit Shal! be fixed on the back of or behind a
switchboard panel or flame.
13.7 Marking of Apparatus :
a) Where a boards is connected to voltage higher than 250 volts, all the apparatus
mounted on it shall be marked in the following colours to which the apparatus or its
different terminal may have been connected.
Alternating Current Direct Current
Three-phase-red Three wire system-2 otherwise
Yellow & blue Positive red & negative blue
Natural-black Natural-black
Where fuse-wire three phase wiring is done, the neutrai shaii be in one coiour and the
other three wires in another colour
b) Where a board has more than one switch shall be marked to indicate which section of
the installation it controls)
c) All markings required under the rule shall be clear permanent.
13.8 Main & Branch Distribution Board :
13.8.1 Main and branch distribution boards shall be any type mentioned in 13.1, 13.8.1. Main
and branch distribution boards shall be of any type mentioned in
13.8.2 Main distribution boards shall be provided with a switch or air circuit breaker on each
pole of each circuit, a fuse on the phase or live conductor and a link on the neutral or
earthed conductor of each circuit. The switches Sha!! a!weys be !inkUd.
13.8.3 Branch Distribution Board :
13.8.3.1 Branch distribution boards shall be provided with a fuse of a miniature circuit breaker of
both the (adequate rating-setting chosen on the live conductor of each circuit and the earthed
neutral conductor shall be connected to a common line and be capable of being disconnected
individua!!y for testing purposes. At !eest one spare circuit of the same capacity Shal! be
provided on each branch distribution board.
13.8.3.2 In residential installations, lights and fans may be wired on a common circuit such sub
circuit shall not have [more than total after points of lights, fans and socket outlets/The load of
such circuits shall be restricted to 800 watts. Ill a separate of an circuit is provided the number
of fans in the circuit Shail not exceed ten. power sub-circuits shall be designed according to the
case Sha!! there be more than two outlets on each sub-circuits
13.8.3.3 In industrial an other similar installations requiring the use of group control of switching
operation, circuits, for (socket outlets
may be kept separate from fans f<v>n lights. Normally
fans and lights may be wired on a common circuit, however, if need is let separate circuits may
be provided for the two. The road on any law voltage sub circuit shall not (exceed 3000 Watts.)
installation, ail
circuits and sub-circuits shall be designed by making provision of
20 (percent increase in load due to any future modification. Power sub-circuits Sha!! be designed
according to the load but in no case shall there be more than four outlets in each sub-circuits
13.9 Installation of Distribution Boards :
13.9.1 The distribution fuse-boards shall be located as near as possible to the centre of the
load they are intended to control.
13.9.2 These Shal! be fixed on suitable stanchion or wa!! and shall be accessible for
replacement of fuses.
13.9.3 These shall be of either metal-clad type, or damp situations, they shall be of the weather
proof type and if instated where exposed to explosive dust, vapour or gas, they shall be of lame
13.9.4 V'.here or more distribution fuse boards feed low voltage these distribution boards
(1) Fixed not less than 2 mm apart or
(2) Arranged so that it is not possible to open two at a time, namely they are interlocked and
the metal case is marked Danger 415 volts or (3) installed in a room of enclosure
accessible to only authorized person.
13.9.5 A!! distribution boards Sha!! be marked lighting, power as the
case may be and also
marked with the voltage and number of phases of the supply Each shall be provided with a
circuits list giving details of each circuit which it controls and the current rating of the circuit and
size of fuse element.
13.9.6 Triple pole distribution boards shall not be generally used for final circuit distribution
unless specification approval of Engineer-in-charge is obtained in special cases where use of
Trippie pole distribution boards are inevitable they shall be of H.R.C. fuse type only.
13.10 Wiring and Distribution Board :
13.10.1 In wiring
a branch board, total load of the consuming devices shall be divided as
far as possible, evenly between the number of ways of the boards leaving the spare circuit for
future extension.
13.10.2 All connections
between pieces of apparatus or between apparatus and terminal
son a board shall be neatly arranged in a definite sequence following the arrangement of the
apparatus mounted thereon, avoiding unnecessary crossing.
13.10.3 Cables shall be connected to a terminal only by soldered or welded or crimped
lugs using suitable sleeve, lugs or ferrules unless the terminal is such a form that it is possible to
securely clamp them without the cutting away cf cable strands.
13.10.4 All bare conductor shall be rigidly fixed in such a manner that a clearance of at
least 2.5 cms. is maintained between conductor of opposite polarity or phase and between the
conductors any material other than insulating material.
13.10.5 If required a pilot lamp shall be fixed and connected through on independent
single-pole switch and fuse to the bus-bars of the board.
13.10.6 In a hinged type board, the incoming and outgoing cables shall be fixed at one or
more points according to the number of cables on the back of the board leaving suitable
in between cables and shall also, if possible be fixed at the corresponding points the switch
board panel. The cables between these points shall be arranged to form a "U" or "S" shaped
loop which shall be of such length as to allow the switchboard pannel to swing through an angle
of not less then
14. Capacity of Circuits :
14.1 Lights and fans may be issued on a
common circuits and such a circuit shall not have
more than a total of ten points of lights, fan and socket outlets or a load of 800 watts whichever
is less. The power circuits shall be designed with a maximum of two outlets
generally when load is not known or specified. In non-residential buildings at important District
centres however one outlet per circuit may be preferred. The circuit shall be designed based on
the loading of the circuit where not specified the load Sha!! be taken as I kw per outlet, where
the load is more than 1 kw it should be controlled by a isolator switch or miniature circuit
15. Passing Through walls and floors :
15.1 Where conductors pass through walls one of the following methods shall be employed.
Care shall be taken to see that wires pass very freely through protective pipe of box and that the
wires pass through in a straight line without any F,vist of cross in wires, on other ends of such
(a) A teak wood box extending through the whole thickness of the wall shall be buried in
the wall and casings or conductors shall be carried so as to allow 1.3 cms air space on three
sides, of the casing conductor.
(b) The conductor shall be caned either in a rigid steel conduit conforming to *IS : 1653-
1964 specification for Rigid Steel conduits of Electrical wiring (Revised) or a rigid non metallic
conduit conforming to *IS : 2609-1963 specification of Rigid conduits for Electrica!
Installations, or in a porcelain tube of such size which permits easy drawing in. The end of
conduit shall be neatly bushed with porcelain, wood or other approved material.
(c) Insulated conductors while passing through floors shall be protected form mechanical
injury by means of rigid steel conduit (see *IS 1653-1964) to a height not less than 1.5 mm
above the floors and flush with the ceiling below. This steel conduit shall be earthed and
securely bushed.
15.2 Where a was tube passed outside a building so as to be exposed to weather the outer
end shall be belt mounted and turned downwards and portly bushed on the open end.
16. Fixing to Walls and Ceilings :
Plugs for ordinary walls or ceilings shall be of while seasoned teak or other approved
hardwood not less than 5 cm long 2.5 c.m. square on his inner end and 2 c.m. square on the
outer end. They shall
be cemented into walls to within 7.5 mm of the surface, the remaining being finished
according to the nature of the surface with plaster of lime punning.
16.1 Where owing to irregular crossing or other reasons the plugging of the walls or ceiling
with wood plugs presents difficulties, the weed casing weed pattern, metal conduit or
clear (as the case may be) Shal! be attached to the wall or ceiling in an approved manner
in the of new building wherever possible teak wood plugs shall be fixed in the walls
before they are plastered.
16.2 To achieve neatness, plugging of walls or ceiling may be done by an approved type of
asbestos metallic or a fiber fixing plug.
17. Branch Switches :
Where the supply is derived from a three-wire of four-wire source, and distribution is
done on the two wire system all branch switches shall be placed in the outer or live
conductor of the circuit and no single-phase switch of use shall be inserted in the middle
wire, earth or earthed natural conductor of the circuit. Single pole switches (Other than
for multiple control) Carrying not more than 15 amperes any be of tumbler type which
shall be 'ON' when the handle known is down.
Where conductors are required to be threaded through tubes or channels formed in the
metal work of fittings Liiofor must be free form sharp angles or projecting edges and
such size that will enable them to be wired with the conductors used for the final sib-
circuits without removing the boarding taping or outer covering as far as possible all
tubes and channels should be of sufficient Size Of permit 'Looping bank' of wires cables
and flexible cords other then those designed for high temperature Sha!! not be used for
wiring fittings except for portable fit limits. All fittings must have not less than a half inch
male nipple Fittings and lamp holders for gas filled lamps shall be adequately ventilated.
18.1 Where light fitting is supported by one or more flexible cords the maximum weight to
which the twi flexible cords may be subjected shall be as follows.
Nominal cross No. & Dia in Max. Permissible
sectional mm of wires. weight
18.2 No inflammable shade shall form a part of light fitting unless such shade is well
protected against all risks or fire. Celluloid shade or light fitting shall not be used under
any circumstances.
18.3 Fitting of wire :
The use of fitting wire shall be restricted to the internal wiring and the lighting fittings.
Where fitting wire is used for wiring, for the sub-circuit loads Sha!! be terminated in e
ceiling zone or connector from which they shall be carried into the fittings.
19. Lamp Holders :
Lamp holders for use on brackets and the like shall be in accordance with *IS : 1258-
1967 specification for Boy onet lamp holders and all those for use flexible pendants shall
be provided with cord grips. All lamp holders shall be provided with shade carriers.
Where centre contact Edison screw lamp holders are used, the outer or screw contacts
shall be connected to the middle wire, the natural and the earthed conductor of the
20. Outdoor Lamps :
Extemal and road lamps shall have weather proof fittings of approved design so as to
effectively prevent the admission of moisture. An insulating distance piece of moisture
proof materials shall be inserted in the fittings. Flexible cord and cord grip lamp holders
shall pot be used where exposed to whether in veranda's and similar exposed situations
where pendants are used, they shaii be oi fixed rod type
All incandescent
lamps, unless otherwise required an suitable protected, shall be hinge
at a height of not less than
m above the floor level. They shall be in accordance with
IS : 418 : 1957 specification for Tongsten Filament General Service
22. Fans, Regulators and Ciamps
22.1 Ceiling fans :
Ceiling fans including their suspension shall conform to *IS
374-1960 specification for
electric ceiling fans and regulators (Revised) & to the following requirements
(a) All ceiling fans shall be wired to ceiling rouses or to special connector boxes to which
fans rod wires shall be connected and suspended from books or shackles with insulators
between rod wires Shal! be connected and suspended from hocks shackles with
insulators between hooks and suspension rods. There shall be no joint in the suspension
rod. but if joints be avoidable then such joints shall be screwed to special couplers of
cm minimum length and both ends of pipes shall touch together within couplers and shall
in addition be secured by
means of split pins alternatively the two pipes may be welded.
(b) Fans clamps shall be of suitable design according to the nature of construction of ceiling
on which these clamps are fitted in all cases fan clamps shall be fabricated from tested
new meta! of suiteb!e sizes end they Shal! be as close fitting as possible Fen clamps for
weed beams shall be of suitable flat iron fixed on two sides of the beam and according to
the size and section of the beam one or two mid steel bolts passing through the beam
shall hold both flat irons together Fan clamps for steel join shall be fabricated from tested
flat iron to fit in rigidly at the bottom flange of the beam. Care shall he taken during form
tested flat iron to fit in rigidly at the bottom flange of the beam. Care shall he taken
during form tested flat iron to fit in rigidly to the bottom flange of the beam Care shall be
taken during fabrication that the metal does not crack while hammering tc shape. Other
fan clamps shall be made to suit the position, but in all cases care shall be taken to see
that they are rigid and safe.
Note All tan clamps shall be so fabricated that fans revolve steadily.
(c) Canopies on top and bottom of suspension rod shall effectively hide suspensions and
connections to fan motors, respectively.
(d) The lead-in wire Shal! be of nominal cross-sectional are a not less than .O mm 2 with
copper and 1.5 mm2 alluminium and shall be protected form abrasion.
(e) Unless otherwise specified the clear distance between the ceiling fan and the floor shall
be less than 2.75 m
22.2.0 Exhaust Fans :
For fixing of an exhaust fan a circular hole Shail be provided in wall to suit the size of the
fan which Sha!! be fixed by the means of rag-bolts embedded in the well the hole Sha!! be
neatly plastered with cement and brought to the original finish of the wall. The exhaust
fan shall be connected to exhaust fan point which be wired as neatto the hole as
possible by means of a flexible cord, care being taken that the blades in the proper
23. Attachment of fittings and accessories :
23.1 In other than
conduit wiring a!! ceiling crosses, brackets, pendants and accessories
attached to watts or ceiling shall be mounted on substantial teak wood block twice
Varnished after all fixing holes are made in them. Blocks shall be not less than 4 cms deep.
Brass screws only shall be used for attaching finings and accessories to their base blocks.
24. Interchangeability :
Similar part of all switches, lamp holder, distribution, fuse board, ceiling rouses,
brackets, pendants, fans and all other fittings of same type shall be interchangeable in
each installation.
25. Conduit Wiring System :
25.1.1 Type and size of conduit All conduit pipes shall be conforming to *IS : 1653-1964,
furnished with galvanised or stove enamelled surface. All conduit accessories shall be of
threaded type and under no circumstances pin grip type or clamp type accessories be
used. No steel conduit less than 16 mm in diameter shall be used. The number of
insulated conductors that can be drawn into rigid Steet conduit are given in Tahle 'L
25.1.2 Bunching of cables Unless otherwise specified, insulated conductors of AC supply and
DG supply shall be bunched in separate conduits.
25.1.3 Conduit-Joints-Conduit pipes shall be joined by means of screwed couplers and screwed
accessories only CIS : 2667-1964)
Specification for Fittings for Rigid Stee! Conduits for E!ectrical Wring. In long distance
stance straight runs of conduit inspection type couplers at reasonable intervals shall be
provided or running threads with couplers and jam-puts (in the latter case the bare O
threaded portion be treated with anti
shall corrosive preservative) shall be provided.
Thread on conduit pipes in all cases shall be between 11 mm to 27 mm long sufficient to
accommodate pipes to full thread portion of couplers or accessories. Cut ends of conduit
pipes shall have no sharp edges nor any or buries left to avoid damage to the insulation
of conductors while puling them through such pipes.
Table-II Maximum Permissible Number of 250-V Grade
Single core cables that can be drawn into rigid steel
(clause 6.51 1)
Nominal Number 20 25 32 40 so
Crossectional and (No. of Cables Max)
area Diameter in
mm of wires s B s B s B B s B s
For Cu. Conductors only
+ For Al Conductors only
Note-I The cable shows the maximum capacity of capacity for the simultaneous drawing-in of
cables. The table applies to 250 volts grade able the columns heads 'S' apply to of conduit
table applies to 250 volts grade able the columns heads 'S' apply to
runs of conduit
which have distance not exceeding 4.2 SM between draw in boxes and which do not
deflect from the straight by angle of than 150. more
25.1.4 Protection against dampess in order to minimize condensation or
seat in inside the
tube, ail outiets of conduit system, shaii be property drained and ventiiated, but in such a
manner as to prevent the entry of insects as far as possible
25.1.5 Protection of conduit against rust The outer surface of the conduit pipes including all
bends, unions, tees junction boxes, etc., forming part of the conduit system shall be
adequately protected against rust particularly when such system is exposed to weather
cases no bare threaded portion of conduit pipe shall be allowed unless such bare
threaded portion is treated with anti-corrosive preservative or covered with approved
plastic compound.
25.1.6 Fixing of Conduit Conduit popes shall be fixed by heavy gauge saddles, secured to
suitable wood plugs or any other approved plug with
screws in an approved manner at
an interval of not one than meter but either side of
one or bends or similar
fittings, saddles shall be fixed at a distance of 30 cm. from the centre of such fittings.
25.1.7 Bends in conduit All necessary bends in the system including diversion shall be done
bending pipes, or by insuring suitable solid or inspection type normal bends, elbows or
similar fittings or by fixing cast iron inspection boxes whichever is more suitable. Conduit
fitting shall be avoided as far as possible. On conduit system exposed to weather, where
necessary, said type fitting shaft be used. Radius of such bends in conduit pipes shall be
not less than 7.5 cm. No length of conduit shall have
more than the equivalent of four
quarter bends from outlet, the bends at the outlets not being counted.
25.1.8 Outlets All outlets for fitting switches etc., shall be boxes, of .suitable metal or any other
approved outlet boxes for other surface mounting or flush mounting system.
28.1.6 Conductors -
Ail conductors used in conduits wirings shall preferably be stranded. No
single core cable nominal Cross sectional area greater than 130 mm shall be enclosed
conduit and used for alternating current.
28.1.7 Erection and earthing of conduit The conduit of each circuit or section shall be
completed before conductors are drawn in. The entire system of conduit and
permanently" connected to earth conforming the requirements specified under pipe in a
workman like manner for a perfect continuity between each wire and conduit. Gas or
water pipes shall not be used as earth medium. If conduit pipes are liable to mechanical
damage, they shall be adequately protected.
25.2 Recessed Conduit wiring system with Rigid Steel conduits Recessed conduit wiring
system comply with all the requirements for surface conduit wiring system specified in
25.2.1 Making of chase The chase in the wall shall be neatly made and be of ample
dimensions to permit the conduit to be fixed in the manner desired In the case of
buildings under construction chases Shal! be provided in the we!!, ceiling etc., at the time
of their construction and shall be filled
after erection of
conduit and brought to
the original finish of the wall.
25.2.2 Fixing of conduit in chase The conduit pipe shall be fixed by means of staples or by
means of soft saddles not more than 60 cm apart. Fixing of standard bends or elbows
shall be avoided as far as practicable and all curves maintained by bending the conduit
pipe itself with a lunge radius which Wi!! permit easy drawing in of conductors. A!!
threaded joints of rigid steel conduit shall be treated with some approved preservative
compound to secure protection against rust.
25.2.3 Inspection boxes Suitable inspection boxes shall be provided to permit periodical
inspection and to
facilitate removal of wires, if necessary. These shall be mounted flush with the wall
Suitable ventilating holes shall be provided in the inspection box covers.
25.2.4 Type of accessories to be used AM outlets such as switches and wall sockets, small be
either of flush mounting type of surface mounting type.
(a) Flush mounting type All flush mounting outlets
shall be of cast iron mild steel boxes
with a cover of approved insulating material or shall be a box made of a suitable'
insulating material.
The switches and other outlets shall be mounted on such boxes as would be approved.
The metal box shall be efficiently earthed with conduit by an approved means
(b) Surface mounting type - If surface mounting type outlet box is specified, it shall be of
any be through flexible conduits of the same size as the rigid
25.3 Conduit Wiring System with Rigid Non-Metallic Conduits:
Rigid Non-Metallic conduits are used for surface recessed and concealed conduit wiring.
25.3.1 Type and size - All non-metallic conduits used shall conform to IS : 2509-1963adb shall
be used with the corresponding accessories (See IS : 3419-1965) specification for
Fittings for Rigid Non Metallic Conduits).
25.3.2 Bunching off cables Conductors of AC supply and DC supply shall be bunched in
separate conduits. The number of insulated cables that may tie drawn into the
space. factor does not exceed
iveri In Table Ill. In this table percent.
Table-ill MAXIMUM PERMISSIBLE NUMBER OF VOLTS GRADE SINGLE, GORE
CABLE THAT MAY BE drawing INTO RIGID non-metallic conduits o
Size of cable Size of Condits (mm)
Nominal Cross Number 16 20 25 32 40
sectional area and (Number of Cables Max)
*For copper conductors only
*For alluminium conductors only.
25.3.3 Conduit joints -
shall be joined by means of screwed or plain couplers depending on
whether the conduits are screwed or plain. Where there are long runs of straight conduit.
Inspection type couplers shall be provided at intervals. For conduit fittings and
accessories reference may be made to IS : 3419-1965.
25.3.4 Fixing of conduits The provision of 25.1.6 shall apply except that the septum between
saddles or supports is recommended to Oe 60 cms for rigid non-metallic conduits.
25.3.5 Bends in conduit wherever necessary, bends or diversions may be achieved by
bending the conduits (See 6.5.3.9) or by employing normal bends, inspection bends,
impaction boxes elbows or similar fittings.
25.3.6 Conduit fittings shall be avoided, as far as possible on outdoor system.
25.3.7 Outlets -
All the outlets or fittings, switches, etc. shall be boxes of substantial
construction. In Order to minimum is condensation or sweating inside in side the conduit,
all outlets of conduit system shall be properly drained and ventilated, but in such a
manner as to prevent the entry of insects, etc. as far as possible.
25.3.8 For use with recessed conduit wring system the provisions of 6.5.2.1 to 6.5.2.4 shall
may be used to soften conduit for bending and forming joints in case of plaint
conduits. As the material soften when heated fitting of conduit in close proximity to hot
surfaces should be avoided. Caution should be exercised in the use of the conduit in
iocations where the amoient temperature is 500 C or above Use of such conduits in
place where ambient temperature is 600 C or above is prohibited.
PVC INSULATED AND P.V.C. sheathed or T.R.S wiring SYSTEM
This system of wiring is suitable for low pressure installation and shall not be used in
places exposed to sun and rain nor in damp places. provided they are sheathed in the
special approved protective covering and weii protected to withstand dampness.
26.1 Attachment to walls and ceiling :
All caies on brick walls, stone or plastered walls and ceiling shall be run on well
seasoned perfectly straight and well seasoned, perfectly straight and well varnished on
four sides, teak wood or any approved hard weed battens not less then 10 mm fin shed
thick, width of
which shall be such as to suit total width of cables laid on the batten, prior
to election, these shall be pained with one coat of varnish or approved paint of colour to
match with surrounding. These battens shall be secured to wall and ceilings by flat head
wood screws to faws plug or Phil plug at an internal not exceeding 75 em. Wood plug
can be used only with special approval of the Engineer in charge. The flat head wood
screws shall be counter within wood batten and smoothed down
26.1.2 Where wiring is to be carried out along the face of the rolled steel joints a wooden batten
adequate width shall first be laid on the same and dipped to it as in corispicousiy as
possible. The wiring should then be fixed to this barking shall be suitable bushed to
prevent the abrasion of the cables.
26.1.3 Attachment to false ceiling: In no case, the open wiring shall be run above the false
ceiling without the approval of Engineer-in-charge
26.20 Link dips: Only alluminium alloy clips/joint clips shall be used. The thickness shall be
0.32 mm (30 SWG) for lengths of 50 mm to 80 mm. The width shall not be less than
mm in all these cases. Link clips/joint clips shall be so arranged that one single clip shall
not hold more than two core or three single core Tiffs of PVC insulated and PVC
sheathed upto 2.5 sq. mm above while-a single clip shall hold a single twin core or two
single core cables. The clips shall be fixed on varnished wood batten switch iron pins
and space at interval of 15 cm bet in the case of horizontal and vertical runs.
26.3.0 Bends in wiring: The wiring shall not in circumscribes be bent so as to form and abrupt
right angle but must be
rounded off qt the corners to a radius not less than six times the
overall diameter of the cable.
26.4.0 Protection of wiring from Mechanical Damage:
26.4.1 In cases where there are chances of any damage to wiring such wiring shall be drawn
complying with all the requirements of conduit wiring system.
26.4.2 Such protective covering shall in all cases be fitted on all down drops within 1.5m from
the floor. or from floor level upto the switch board whichever is less.
26.5.0 Passing through floors: All cables taken through floor shall be enclosed in heavy gauge
steel conduit extending 1.5m above the floor or upto the switch board whenever is iess
and flush conduits or pipes Sha!! be neatly bushed with porcelain wood or other
approved material. The conduit pipes shall be security earthed.
26.6.0 Passing through walls: When conductors pass through walls, anyone of the following
methods shall be employed. Care should be taken to see that Wires pass very freely
through protective pipe or box and that wires through in a straight line without any
twist or cross in wires on their ends of such holders.
(a) A box of teak wood or approved hard wood extended through the hole thickness of the
wall shall be buried In the wall and casings or conductors and casing or conductors shall
be carried so as to allow 1.3 cm air space on the three sides of the casing of the
(b) The conductors shall be carried in. an approved heavy huge solid drawn or lap weld
conduit or in aporce-tain of such a size that it permits easy drawing in, the enciad of
conduit shall be neatly bushed with porcelain, wood or other approved material.
26.6.1 Where a wall tube passed outside a building so as to be exposed to weather, the outer
end shall be mounted anutured downwards and property bushed or the open end, The
conduit shall be neatly arranged so tjjat the cables enter them without bending.
26.7.0 Buried cabies: Tiie HIS PVC sheathed cabie shaii not normaiiy be burring directly in
plaster. Where so specified in the special in the specification they may be taken in task
wood channeling of .ample capacity or conduit pipe boned In She wall.
26.8.0 Stripping of outer covering: While citing and stripping of the outer covering of the, care
shall be taken that the sharp edge of the cutting instrument does not tough the inner
insulation of the conductors. The protective outer covering of the cables shall be stripped
near connecting terminals as far as practicable. Care shall be taken avoid
hammering on link clips with any metal instrument after the cables are laid. Where
junction boxes are provided they shall be made moisture proof with a plastic compound. o
27.0 PAINTING WORK IN GENERAL:
27.1 Paints: paints, oils varnishes etc. of approved make in original to the satisfaction of the
Engineer -in charge shall only be used.
27.2 Preparation of surface: The surface shell be thoroughly cleaned and dusted before
painting is started. The proposed surface shall be inspected by Engineer-in-charge or his
authorized agent and shall have received the approval beore painting is commenced.
27.3 Application: Paint shall be applied with brush. The paint shall be spread as smooth &
event as possible particular care shall be paid to rivets, ruts belts and cover lapping
Before drawing cut, it Sha!! be continuously stared, in the sarc!ier containers with e
smooth stick while it is being applied.
Each coat shall be allowed to dry out sufficiently before a subsequent coat is applied
27.4 Scope: painting on old surface in in/door Situations will not include prier. coat except
where specially motioned in the schedule of work or special specification. However,
where rust has formed on iron and steel surfaces the spots win be painted with one anti-
mi! primer coat.
27.5 Precautions: All furniture fixtures, glazing floors, etc. shall be protected by covering, All
stains smears, opa-shirig, dropping of every kind shall be removed. While painting of
wiring etc. it shall be ensured that painting of will ceiling etc. is not spoiled in any way.
27.6 Painting of conduit and accessories: After installation surface of conduit pipes, fittings
switch and regulator boxes, etc. shall be painted with two coats of approved enamel i
paint or paint as required to match the finish of surrounding wa!!, trussed, etc.
The clip for batten wiring shall be of Alluminium conforming to I.S. specification No.
Important Clauses of Indian Electricity Rules, 1956. Following clauses of Indian
Electricity Rule, 1956 shall in particular be taken care of in the execution of electrical
Clause No. Subject
3. Authorisation :
29. Construction, installation, protection, operation and maintenance of electric supply lines
and apparatuses.
31. Cut-out on consumer'spremises.
32. Identification of earthed and earthed neutral conductors and position of switches and
cutouts therein.
33. Earthed terminal on consumer's
34. Handling of electric supply lines and apparatus.
41. Distinction of circuits of different voltages.
42 Accidental charge.
44. Provisions applicable to protective, equipment.
45. Instruction for restoration of persons suffering form electric shock.
45. Precautions to be adopted by consumers, owners electrical contractors. Electrical
workmen and suppliers.
46. Periodical inspection and testing of consumer'sinstallation.
48. Precautions against leakage before connection
50. Supply to consumers.
51. Provisions applicable to medium high voltage installations.
58. Point of commencement of supply.
59. Precautions against failure of supply; Notice of failures.
61. Connection with ea\th, (low and Medium Voltage system.)
64. Use of energy at high and extra-high voltage system.
67. Connection with earth. (high & Extra-high voltage systage)
68. General conditions as to transformation and control of energy.
under Chapter VIII on Overhead Lines.
137. Mode of entry.
138. Penalty for breaking seal.
139. Penalty for breach of rule
140. Penalty for breach cf rule
141. Penalty for breach of rules.
Form of Completion Certificate
IIWe certify that the installation detailed below has been installed by me/us and tested
and that to the best of my/our knowledge and belief, it complies with Indian Electricity Rules.
1956, as we!!as the C.P.W.D. Genera! Specification for Electircal Works,
Electrical Installation at Voltage and system of supply
(1) Particulars of works:
(a) Internal Electircal Installation No. Total Load Type of system or wiring
(iii) Plug point
(a) 3 pin 5 Amp.
(b) 3 pin 15 Amp.
Description H P!KW Type of starting
(a) Molars: (i)
(c) Other plants:
(d) If the work involves installation of over head line/or under ground cable:
(i) Type & Description of overhead line.
(ii) Total length & No. of
(iii) No. of street light & its description
(b) (i) Total length of under ground cable & its size
(ii) No. of joint.
St. through joint:
Description of earthing electrode
No. of earth electrodes :
(iii) Size of main earth lead:
3) Test Results:
Insulation Resistance: o
Insulation resistance of the whole system Megohms.
of conductors to earth.
Insulation resistance between the Megohms.
Phase conductors and neutral.
Between phase R and neutral. Megohoms
Between phase Y and neutral Megohorns
Between phase B and neutral Megohoms
(iii) Insulation resistance between the phase conductors in case of polyphone supply.
Between phase R & phase Y Megohoms
Between phase Y & phase B Megohoms
Between phase B & phase R Megohoms
(b) Polarity Test:
Polarity of non linked single pole braches switches.
(c) Earth continuity Test:
(7 maximum resistance between any point In the earth continuity conductor including metal
conduits & main earthing lead.
(d) Earth Electrode Resistance.
Perestance of each electrode.
Lighting protective System:
Resistance of the whole of lighting protective system to earth before any bonding is
effected with electrode and rnotal in/on the structure.
Signature of Supervisor Signature of Contractor
Name & Address Name & Address
All Specification standard publication etc. specified
mean the latest standards, publication etc.
pertaining to electrical and should conform to the following wherever applicable.
1) Indian Electricity Act. 2003 with its amendments.
2) Indian Electricity Rules 1956 and its amendments.
3) Indian Electricity supply Act
4) Regulation for Electricity Equipment in building by I.E.F. Landon.
5) The Factoty Act, 1948 and its amendments.
6) I.S. 732* 1982 Part -1, II & 1.11 code of practice for Electrical wiring and filings in
buildings for low and medium voltages
7) I.S. 4064-1976 H.D. Air break switches and fuses for-Voltages not exceeding 1100 volts.
8) I.S. 3043 Earthing code of practice for
1554 Part-11970 PVC insulated (Heavy duty) Electrical Cables for working
voltages upto and unfading 110 volts
PVC insulated cable with Alluminium conduits (revised) for
voltages upto 110 volts.
Electrical installations in buildings method of measurements of.
General requirement for switchgear -and control gear for voltage not
exceeding 1000 volts-
rigid steel conduits for electrical wiring (revised)
14) I.S.: 2509-1973 - Rigid steel conduits for electrical installation (First revision)
Bayonet landholders (First revision)
16) I.S.: 418 1957 Tungsten
Filament General service-electric lamps (Third revision)
Fans and Regulators, ceiling type, electric (second revision)
Filings for rigid steel conduits for electrical wiring.
19) I.S.: 3419-1976 - Fining for rigid non-metallic conduits (First revision)
20) National Electric Code,
Abstract of the Wiring Rules of the Institution of
Electrical Engineer
(Referred to in the specification)
Division (See clause 2 of the specification)
electrical system in which all the conductor and apparatus are connected to a
common source of supply.
1) Eatthed: Effectually connected, to the general mass of the earth. Solidly earthed without
the Intervention of a fuse. switch, circuit breaker, resistor reactor or solenoid.
2) Un-insulated Conductor: A conductor without provision, by the Interposition of a
dielectric or otherwise. for its insulation from earth.
3) Bare: Not covered with insulating material.
4) Dielectric: any material which offers high resistance to the passage of an electric current.
5) Bunch Conductor: When more than one conductor is contained within a single duct or
groove or when they are run enclosed and spaced and not spaced apart from each
6) Points: In wiring as
per IS: 5908 -1970 Method of measurements of electrical
installation in buildings.
7) Switch board: Assemblage pf switchgear with or without instruments, but the term does
group of local switches in a final sub- circuit where each switch has'its own
insulating base.
Note : In the electricity (Factories Act) special regulations, 1908. and 1944 the term
"Switchboard" includes "Distribution board.'"
8) Single pole switch: A switch suitable for closing and cr opening a circuit on one phase or
9) Linked switches: A switch the blades of which are so linked mechanically as to make
break all poles simultaneously or in a definite sequence.
10) Fuse Switch: A switch the moving pan of which carries one or more fuses.
11) Three W:re System :
a) Outer Conductor: Those between which there is the greatest difference of
potential. This use of the word outer must not be confused with the use of the work when
applied to the extemal conductor of a concentric main.
b) Neutral Conductors: The term includes the neutral cond4ctor of a 3 phase 4 wire
system, the conductor of a single phase or d. c. installation which is earthed by the
supply undertaking (or otheraqse at the source of the supply) and the middle wire or
common return conductor of a 3 wire d.c. or single phase a.c. system.
12) Semi enclosed machine: One in which the ventilating openings in the frame are covered
a) Girds expanded metal or wire gauche, with openings of less fhan 1/4 Inch but not
less than so as to obstruct free ventilation.
b) Wire gauge. in which the openings are less than 1/4 inch but not less than 3/32
inch (diameter or width):
c) Screens with smaller openings than the above.
13) Totally enclosed Machine:
One in which the enclosing case and bearings are dust proof and which dose not allow
circulation of air between the inside and outside of the case.
14) Pipe Ventilated Machine: An enclosed machine in which, the frame is so arranged that
the ventilating air may be conveyed to it through a pipe attached to the frame the
ventilation opening maintained by the fanning action produced be the machine itself.
15) Forced draught machine: An enclosed machine in which the ventilating air supply is
maintained by an independent fan externai to the machine itseif.
16) Protected Machine: One having end shall bearings and in which is free access to the
interior without opening doors or removing covers.
SWICHES AND BREAKERS CIRCUIT
(See clause !! of Specifications)
17) Switches and Circuits Breakers:
Switches and circuit breakers (rules 2b. 36 and 37) whether fixed separately or
combined with lamps, holders of fittings, must comply with the following requirements:
Over threading must not take place at the point ct contract or elsewhere, when the full
current flows continuously.
(b) They must be so constructed or arranged that the contracts cannot accidentally close
when left open.
The basis must be of incombustible, nonconductor and moisture proof material.
Circuit breaker as must be so agganged and placed that no combustible material is
endangered by their action.
Unless placed an engine room cr in compartment arranged .for the purpose, they must
their live parts covered. The covers must be incombustible material and, must be either
non-conducting or of rigid meta! and clear of a!! interne! machinery. Fei! more then
amperes, ai pressures exceeding 125 voltas metal covers must be lined with insulating
(O In positions where they
are liable to injure or come into contract with goods, they must
be further protected by an open fronted box or other suitable guard.
(g) Handles must be insuled so arranged that the hand cannot touch live metal, or be
injured through and adjacent face blowing.
(h) Switches having a handle projecting through en, open salt in the cover, must not be
Signature of Contractors Executive Engineer
GENERAL REQUIREMENTS
1.1 Scope of works:
The work covered by electrical specification consists supplying and installing, electrical
wiring system complete in strict accordance with this specification and the applicable
drawing and subject to the terms and conditions of the contract./tt includes.
(a) Conduit and wiring system for fans, lighting points bells, clocks sockets, etc. including
fixing of lighting fixtures and fans etc. and miscellaneous points.
(b) Conduit and wiring system for exhaust fans, power sockets etc.
(c) Panel boards, distribution boards, switch fuse units.
(d) Complete power and lighting cable systems.
Grounding system.
Conduits system.
(g) Street lighting system.
(h) Other miscellaneous electrical work.
1.2 Completeness of Contract;
Any work fittings accessories or apparatus which may not have been specifically
mentioned in the specification but which are necessary in the equipment for efficient
working of the plant should be deemed to be included in the contract and should be
executed and provided by the contractors. All plant and apparatus should be complete in
all the details, where such details, are mentioned in the specifications or not.
Three prints and one permanent negative of each of the finally approved drawings
incorporating all the modifications proposed by the Department should be submitted. No
modifications should be made in a drawing already approved by the Engineer-in-charge
without his prior consent.
Approval of the contractor's drawing will not relieve the contractor of any part of his
(7 obligation to meet all the requirements of .the contract.
The performance of all the equipments and the installation should be guaranteed at least
a minimum period of one year from the date of taking over the installation by the
Department. All equipments must comply with the relevancy IS-BS specifications.
1.4 Interchangeability:
All corresponding parts of similar plant and equipment should be interchangeable in
All special tools required for dismantling and assembly of the equipment covered by the
contract shall be supplied as obligation under the contract.
A list of to be supplied by the Contractor should be submitted along with the tender.
Specifications for Electrical Installation in Buildings
1.1 These specifications relate to the electrical installations in the buildings of P.W.D.
Electrical. The specifications cover general requirements to be fuifiiled. These general
specifications are supplemented by the specifications for the particular buildings
separately attached.
1.2 These specifications are governed by the General conditions of the contract attached
1.3 APPLICABLE RULES AND REGULATIONS:
1.3.1 Installation shall be carried out conformity with regulations for electrical equipments of
buildings, published by the Institute of Electrical Engineers London (14th Edition
and as amended upto date) herein after referred to as the I E. E. wiring regulations
Where these specifications, or the special specifications for the particular building
attached hereto are at variance with the I.E.E> regulation shall also comply with the
requirements of the Indian Electricity Act, 1910 as amended upto date rules issued there
under and also the regulations for the Eiectricai Association of India Where not specified
otherwise, the instel!ation should fo!!ow the Indian standard codes of practice
and in their absence the relevant British Standard of practices. All the materials shall
comply with the relevant Indian Standard of British Standard specifications
1.4 DEFINITIONS:
1.4.1. The definitions of terms in the I.E.E. Regulations shall apply in general.
1.5.1. The preliminary drawings only indicate the general scheme of requirement. The exact
position of all points, control switch boxes,
runs of wiring and/or conduits
inspection boxes, Ilains, and sub-distribution boards, mains etc shall be got approved
Engineer-in-charge. All circuits shall be clearly numbered in wiring diagrams and building
plans. The detailed design of a switch-board, special fixture or any other part of the
electric as may be ca!!ed for by the engineer-in-charge she!! also be supplied
by the Contractor and should be got approved by the Engineer-in-charge. Three sets of
completion drawings and wiring diagrams showing the instillations as executed shall be
supplied by the contractor along with the completion certificate.
materials shall be new and of the best quality conforming to the relevant I.S.B.S.
specifications. They must be the products of manufacturers of many years or
standings, All like parts of materials shall be interchangeable. In
case of equipments
such as circuit breakers; switch fuses etc. a descriptive and illustrated literature shall
accompany the tender. The names of manufacturers' of various materials shall be
furnished in proform in Appendix-I. Samples of materials wherever required should be
deposited with the Engineer-in-charge. All materials shall be rust-proof or rendered rust
proof by application of suitable paints. The supply of all equipments, switchgears etc.
shall be complete with accessories. filings and mountings as may be required for their
proper performance, and as specified in the relevant IS-BS Code of Practice and
1.7 WORKMANSHIP:
17.1, Good workmanship and neat finished appearance are the prerequisites for complying
with the clauses. of these specifications. With a view to fine workmanship the
Tenderer Sha!! employ licensed wiremen with an experience of not less than 5 years in
the type of work they are engaged. The work should be done under supervisions of
licensed Electrical Supervisors with good educational qualifications and considerable
1.7.2 Tenderer shall furnish the names of Supervisor and their wiremen. who will be engaged
in this work, with details of their experience.
1.8 CO-OPERATIVE WITH CIVIL AND OTHER WORKS CONTRACTORS:
1.8.1 The Tenderer after the award of the contract, Shal! co-operate with the civil and other
contractors and shall coordinate his work of the other contractors with the least amount
of dislocation and interference to the other works. Tenderer shall go through the
drawings carefully and shall furnish the Engineer-in-charge with all the details of
openings in the walls etc they may be required for concealing any of the electrical
equipments or accessories. VVhere the contractor fails to furnish such information as
may be required for the purpose of concealing the equipments etc. they shall be made at
his (Contractor) cost and expense. Any alteration to parts of the building shall be made
good at the contractors expense and brought to the original shape finish and colour.
The electrical contractor shall be completely responsible of the testing and
commissioning of those installations covered by these specifications in compliance with
the standard procedure, in obtaining permission of the Government Electrical Inspector.
Any modification which is demanded by Government Electrical Inspector shall have to
(7 be carried out within the scope of the contract. The contractor shall submit four copies of
drawings of installations as per regulations for shall be provided by the contractor for
carrying out the installation work. All test shall be carried out in the
presence of the
Engineer-in-charge or his authorized representative and his approval obtained for the
1.10. COMPLETION CERTIFICATE AND MAINTENANCE GUARANTEE:
1.10.1. After the completion of the installation and contractor should furnish a certificate in the
proforma in Appendix-III, at the time of taking over the installation by the Department.
The installation shall be guaranteed for period of 12 months from the date of taking over
by the Department. During the period of guarantee all defects in material or
workmanship shall be rectified or rectified or replaced free of cost to the Department.
1.11 TENDERER'S ABILITY
1.11.1. In order to enable the Department to asses the ability of the Tenderer to execute the
work, the Tenderer shall furnish evidence ot his experience and capacity to carry ounhe
magnitude and nature.
1.12.1. The rates of items shall include all traces, transport, loading and unloading charge and
all such charges that may the market not entertained Break up figure as required in
the schedule of work shall also be furnished. As far as possible indigenous materials
only shall be included for supply. Where It is unavoidable, imported items
included and Tenderer should dearly indicate materials, quantity, rate and amount of
1.13 STORAGE SPACE:
No covered storage space will be provided-by the Department. The contractor has to
make his own arrangement. However, the Department may give an open space near the
place of execution where the contractor can build his own stores for executing the work.
1.14 DEPARTURE FROM SPECIFICATIONS:
The Tenderer should clearly indicate departure, if any from the specifications with
reasons for the same.
1.15 EXTRA ITEMS:
Rates for extra items shall generally be derived from the rates already available in the
schedule. Where it is not possible, the rates shall be mutually agreed upon and
contractor Sha!! furnish a detailed analysis of the rates claimed by him.
2. TECHNICAL SPECIFICATION:
2.1 Supply System:
The wiring installation shall be suitable for 3 phase 4 wire, 400-440 V 50 cycles system
of supply Colour code of different phase shall be followed as
2.2 Wiring for Light and Fans:
2.2.2 Looping system to wiring shall be adopted. No joints shall be made at intermediate runs
of cables and where they are unavoidable. such joints shall be through approved
mechanical connections.
2.2.2 Point wiring:
Point wiring shall consist to the branch wiring from the board together with the controlling
switch or push as far as and including the ceiling
rose or any other approved connector
or socket, outlets. In case of more than one light being conerulled by one switch, the
wiring upto the ceiling
rose of the first light including the switch shall be considered as a
Primary point. Loop wiring from light shall be considered as a' Secondary' point and
rates shall be quoted separately, including final connections to fixtures and plugs.
2.2.3 Conductors:
No conductor for final sub circuit wiring for light and socket outlets shall across-section
less than that of 2.5 sq.m (aluminimum)
No final sub-circuit radiating from the fuse board of a sub-distribution board arid wires
with 25 sq. m. (A!) cable Sha!! carry more then 10 lights, fans or socket outlets or a
connected load of 800 watts whichever is greater. The following wattages may be
assumed for estimating the load on each sub-circuit unless otherwise known or
Incandescent lamps 100 watts
Ceiling fans 60 watts
5-A Socket Outlets (lighting) 100 watts
4. tube 50 watts
5. ft. fluorescent. tubes 100 watts
In each sub-distribution board at least-one
way preferably two ways shall be left
spare for future requirement. A wiring diagram giving the exact Utilization of the ways
shall be prepared and fixed in the sub-distribution board itself or any other easily
accessible place. The ways of sub distribution boards shall be accordingly numbered.
2.2.5 Local Control Switches (Genera!) .
Local control switches for circuit carrying net less than 5-5 shall be piano type and shall
conform to relevant I.S. Standards. The switch shall be "ON' when the knob is in the
down position. All local control switches shall be connected in the phase or live
conductor only and in the natural conductor, switches shall be fixed in iron clad box and
shall is so placed that the centre of the switch box is 1.3 Mtr. from the finished floor level
unless otherwise stated. All switch boxes Shail be provided with 1 18" thick Perspex
cover fixed to the switch box with chromium plated counter sunk screws (brass).
2.25A Switches (Two way) :
Two way swatches shall be piano type single pole, double throw, 250V, suitable for flush
mounting and of 5A capacity as per the drawings. All switches shall be recessed in an
embedded metal box.
(b) Each box shall have suitable outlet for fixing conduts directly.
(c) Each box shall have Perspex cover painted inside with the wall colour, if required.
(d) Each switch shall have suitable for the position in a stairway wiring. 2.2.5.B Switch
Boxes (General) Electrical circuits shall be written suitable on the cover of all switched
boxes, as approved by the Engineer-in charge (elect) whenever different phase are
terminated in a switch box bakelite partition shall be provided. Each cash shall be
provided with a G.I. Earth stud nut and washers for earth connectors.
2.2.6 Ceiling Rose:
rose shall be used on circuits having a normally exceeding 200V. Only one
flexible cord shall be attached to a ceiling rose. Only 3-pin 5A socket outlet shall be
provided in lighting circuits. All socket outlets be provided with a control switch and they
shall be mounted in switch boxes in an approved manner.
2.2.7 Fittings:
These shall be of approved type as specified in the tender schedule. The subscripts
leads should terminate in a ceiling rose or conductor in the fitting and intemal connection
made there from. Wherever these fitting are suspended they shall be done so through
the conduits and ball and socket joint. All fittings shall be grounded by a G.I. conductor
not less than 16 S.W.G.
2.2.8 Flexible wiring:
Flexible cords of not less than .23/0076 size be shall be used, The weight of suspension
road shall be governed by I.E.F. Regulations.
2.2.9. Ceiling Fans:
All ceiling fans shall be wired to ceiling rose and suspended from a hook shackle or
clamp and insulated from the same. All joints in the suspension, road shall be screwed
and means of split pins. The fan clamps supplied by the Contractor shall be suitable for
the ceiling or proof member as the case may be For concrete roofs, fan hooks shall be
buried in concrete during concrete during construction in an approved manner and
secure bound to the reinforcement.
2.2.10 Conduits and Earthing:
Allconduits feeding lighting and circuits shall be provided with earth continuity G.I.
conductor as specified for power wiring. A!! conduits she!! be as specified for power
2.3.1 Point wiring:
Point wiring power shall be as defined under section 2.2.2 and shall include the switches
2.3.2. Loading:
All distribution board for power wiring shall be not less than 15 A per way. Loading per
way shall not exceed normally 100 watts. The following loads may be assumed if exact
figure are not known.
3-Pin 15A Outlets 1 .OOO Watts
3-Pin 5A Outlets 100 Watts
2.3.3 Wiring for Motors :
2.3.3.1 Final sub-circuits loop in motors shall be connected to separate ways of the Distribution
board if the current in the sub-circuit is less then 15A. No looping is permissible.
2.3.3.2 All wiring shall be carried in H.G. conduit as specified in I.S. specification for gauge for
different sizes of conduit. When the motor is resiliently mounted fixable with approved
adopters Shal! be used for the last few feet. lö/here cables are used sufficient loop Sha!!
2.3.3.3All switch fuse units controlling circuits feeding motor .shall be pr9vided with H.R.C.
fuses or as specified:
2.3.3.4 The frame of every motor and its association contra gear shall be earthed by two
separate and distinct connections to earth connector shall be capable of earring 3 times
the rating of fuse or 1.1/2 time the setting or the circuit breakers but in no case than
NO.8 S.W.G. or 7064" or equivalent cross section of copper. Where practicable, the
earth connections shall be visible for periodical inspection. Gas or water pipes shall not
be used for earth connections.
2.3.3.5 Socket Outlets and Control Switches f A and 15A :
All socket outlets
shall be of 3 pin type, the third pin being connected to the earth stud of
nearest distribution board by separate earthing wire: The socket shall conform to I.S.:
1293/1938,'single pole, piano type. Each socket pubets shall be provided with a control
switch of appropriate rating and as specified. The switch and socket shall be mounted
inside the iron ciad box provided with li8n Perspex cover as directed by the Engineer-in-
charge or as specified in schedule of quantities. Inside switch box ample space shall be
available around switches for connection wires to switches. All socket outlets for
shall be mounted at the skirting level otherwise specified or as directed by the Engineer-
The three phase plug receptacles shall have their earth terminals connected by
independent earth wires to ring main strip on the building. In buildings where explosion
proof fixtures are installed single phase plug receptacles as well as light points shall be
connected to ring main ground bus installed in the building by separate earth wires of
Socket outlet shall have some provision not to receive the matching plug unless the
grounding pin is in correct position. The grounding pin of the plug shall make the
contract first and break the contract last at the time of inserting or removing the plug
The grounding terminal shall be connected to the enclosed metal body providing
G.I.Stud, nut washers welded to the box.
Each unit shall be suitable for flush mounting as required and indicated in the applicable
Combination unit socket outlet and switch shall be complete with necessary internal
wiring. The switch/socket
shall be mounted on M.S. bracket enclosed in a box.
2.4 Conduit Wring:
2.4.1 Where conduit wiring is adopted type and size of the conduit shall be as indicated in the
drawing. The minimum of the conduit shall be 19 mm.
2.4.2 The contractor shall thoroughly study the structural of the buildings and wherever,
necessary shell in consolation with Departments representatives at site, make suitable
adjustments in the cable routings, earthing arrangements, and location boxes, fitting etc.
with a view to avoid interference with any part of the building, structure, equipment or
any other work in the building or to effect any improvement in the arrangement.
Protection of conduit against rust:
Conduit shall be given two coats of oxide paint before they are placed in position. All
exposed conduit shall be planed after installation with the colour as approved by the
Engineer-in-charge. This dc not apply to galvanized conduit.
2.4.3.A.Protection against insects arid damp:
In Order to minimize cocensation or sweating inside the conduit,
system shall be
properly drained any ventilated in such a manner as to prevent the entry of insects.
2.4.4. Conduit shall first be installed as a complete system without cables and shall be
continuous from outlet to outlet from fitting to fitting and mechanically and electrically
connected to a!! boxes and fittings.
2.5. SPECIFICATION FOR POWER CONTROL AND TELEPHONE CABLES:
The specifications cover the supply and medium voltage "Power and control cables
either in ground or trench depending on the conditions at sate including accessories for
the same. The work in general, consists of supp!ying, laying jointing terminating and
connecting at. 1.1. KV APLSTS PVC power and control cables.
ii. The contractor shall supply all accessories including jointing and terminating materials,
compound, tapes supporting materials, cleats cables lugs, concrete stable, bricks sand,
cable-markers etc. as required to make the installation work including digging and filling
of the trenches as required.
power cables to be supplied mentioned as 'APLSTS' in the Schedule should be mass
impregnated, non draining, paper insulated lead sheathed, double steel tape armored
and must comply with the latest ISI BS specifications.
ii. All cabling materials such as cable compound, cable lugs, taped shall be of approved
quality acceptable to the type recommended by the manufacture of the cabie for which it
is used and approved by the Department.
as installation of all equipment shall also conform to the applicable. Codes and practice
as per the IS and shall be executed to comply with the lates Indian Electrical rules as
regards the safely, payable of equipments and other essential provisions specified
iv. Only approved make of cable shall be used. ICC and CCI will be preferred,
The cables shall generally be laid as per is Code of practice.
Ill. GENERAL RULES CABLE LAYING:
Installation shall be carried out in a neat workmen like manner by skilled experienced
and competent workmen in accordance with the standard practices.
Cables shall be laid preferably in one length to avoid joins. If straight joints are found-
necessary, these can be introduced with
approval of the Engineer-in-charge. The
cost of the straight joint however, shall not be borne by the Department. But in no case
joint shall be within the conduit G.I. pipe and duct.
Proper care should be exercised in handling the cable to avoid formation of kind etc. and
should it become necessary a cable be bent to a radius not less than 20 times the
overall diameter of the cable.
iv. Method of installation, routing of cable etc. shall in every case be subject to the
Department's approval and the contractors shall modify and or certificate no extra cost to
the Department's any portions of the installation which do not meet with the
Department's approval. All damages to the civil and other works on this account shall be
made good by the contractor at no extra cost to the Department.
The electrical contractor while notifying the building contractor for such work shall furnish
the proper draws, dully explaining the work involved of indicate at suit actual work to be
may be required by tothe building contractor. The electrical
work as the electrical work with this the same has been completed.
Where cables pass through hume pipes, contractor shall fix hard wood bushed round the
cables at the ends of hume pipes. Where the cables pass through the floors or
chambers and in such situation's the Engineer shall require, the contractor shall seal
cable holes in a manner approved by Engineer-in-charge. Where cable. pass through
roads mullahs. etc. cables must be protected by class 'A' Hume pipe of diameters not
less than 6. (15cms).
vi. The cable routs shall be the shortest and these shall be minimum inference with built up
areas, lawns etc.
vii. Care shall be exercised for providing suitable props other service lines on earth at the
time of excavation. Where cutting of a lawn inevitable it should be with the approval of
the Engineers-in-charge.
viii. Excavation of the trenches shall be executed with vertical sides and the trenches shall
be kept as straight as possible. The exact location of each trench shall be settled by the
Engineer-in-charge. On the site when the contract is in a position to commence each
portion of the work.
The trench shall be not less than 1/2 meter wide and 90 cms deep. If more, cables are to
be laid, .the width should be suitably increased.
ix. After the cables are laid, the trench shall be filled in layers, the each layer being weal
rammed by spraying. water and consolidated and sufficient alloviance made for
settlement. The extra earth over the trench should be removed from the place of trench
to a place as decided by the Engineer-in-charge at site.
x. Ends of cabies shaii be property seaied to prevent entry of moisture prior to instaiiation.
xi. Where it is as specified as 1/2 core cables the 1/2 core shall be a natural conductor
having reduced section.
xii. For all multi core cables each core and tails shall be brought not, marked and or colored
xiii. Cables termination shall be done with suitable compression brass glands in the case of
PVC cables and cast iron trifurcating boxes in the case pf APLSTS cables. The Armour
should be connected to the right main earth building with duplicate earth wires as per the
relevant IS/BS specification.
The core insulation over each conductor shall however be retained through out the run
of the conductor upto the end where lungs shall be fitted thereon for connections. The
lungs Sha!! by fitted by means of approved solder and the such as e!eap and Eyer NO.
used. The joint shall be mechanically strong and pressure tested.
2.6 DISTRIBUTION BOARDS AND PANELS.
General Requirements :
2.6.2 All distribution panels shall comply with IEE. Rules 60-61. A clear distance of 0.91 b
meter in front of the switch board shall be kept. Where bare connections of attachment
are provided at the back of the switch board the space behind the pane! she!! begetter
less than 0.299 meter or more than Q.762 main width there shall be a passage way from
the further outstanding part of any attachment or conductor. If the space behind the
switch board exceeds 0.70 main width there shall be a passage
way from either end of
the switch board clear to night of 1.928m width 0.299 m. All wiring connection shall be
made neatly and securely.
2.6.3 For crocoites carrying more then 10 Amps, tinned ceb!e sockets Sha!! be used, e!!
connections shall be so made as to form own diagram Circuit shall be clearly numbered
to correspond-to wiring diagram. Names of the distribution boards shall be painted as
directed by the Engineer-in-charge. All the which fuse units and isolators D.Bs. shall be
complete with earthing studs lugs neutral bar ink. H.R.C. fuses and of approved make.
2.6.4 Skeiten type panels shall have a rigid from work adequately braced and supporting
frames adequately braced over which sheet metal shall be nearly secured. All switches
distribution boards etc. Sha!! be neatly arranged on the panels end e!! connections made
from the back of switches. The panels shall be rendered dust and vermin-proof. The
interior of the panels shall not be accessible to unauthorized persons.
2.6.5 The recess type boards shall .be embedding wall in —a cupboard with a metal hinged
door with locking arrangement. In all recessed conduit work all distribution boards shall
be recessed. Where recessing is not possible, free standing panel may be provided as
approved by the Engineer-in-charge.
individual components the switch fuse units D.Bs. etc. shall be connected by earth
connected by earth continuity wire of appropriate size with the main earth bus of the
D.B.etc.The panel switches of D.Bs. shall be earthed by the less than 2 distinctive paths
to earth. Earthing of metallic parts of exposed metal shall not be effected through
structural metal work which houses the installation. Where metallic parts are not required
to be earthed and
are liable to become alive should the installation of the contractor
become defective such metallic parts shall be separated by durable non conducting
malarial from any structural work.
(a) Power panels shall be 3 phase, 4 wire, 400.230 volts for the distribution of 3 phase or
single phase power loads. Lighting panels shall be 3 phase 4 wire 400/230 volts for
single phase lighting load distribution on all 3 phase.
(b) All panels shall be done of protected front type with no mechanical or electrical defects.
(c) Bus bars shall be of electrolytic copper or alluminium as specified and the properly
tinned sizes as indicated on applicable drawings as required.
outs for branch circuits entries shall be drilled and filled as required, for lighting
panels the top and bottom cover plates shall be. removable type.
Main disconnect device for aii panei boards shali be of switches of disconnect type and
of the size as indicated shall be mounted directly below the panel or through a short
thread conduit of required size.
The main disconnect for all panel boards shall have an entry suitable for PVC Armored
cable from bottom.
panel boards shall be provided with an earthing terminal and lug for connection to the
grounding system.
(h) Temperature rise of all electrical parts shall not be more than 300c With full load
amperes at room temperature.
All barnes and supports of current carrying parts shall be of moisture resistant insulating
material and shall not be adversely affected by arcing.
(k) The locations of panels shown in the drawings are only tentative; panels may be located
at a place approved by the Engineer-in-charge.
All civil works connected, with fixing such as grouting chasing and making good shall be
the Tenderer responsibility.
(m) Wires adequate capacity with proper size of lugs shall be used for inter connections.
(n) Panel should be self supported on angle channel iron frame work. It should be preferably
of bolted construction in bolted or grated rigidly after leveling and alignment.
(0) The cupboard and D. B. should be of such size so to be accommodated in the existing
room as per 1.5 rules and I.S. codes of practice for installations of Medium voltage
(p) Fabrication drawing showing the detailed dimensions and panels and its components
indicating the frame work, earthing positioning of switches. 6 Bs. cable boxes, adopter
chambers etc shall be furnished to the Engineer-in-charge for his approval. All material
to be got approved by the Engineer-in-charge. Panel should be guaranteed for
satisfactory operations for a period of one year after handing over.
(q) The panel should be painted with anticorrosive paint suitable for humid ,and salty
atmosphere on two coast to primer.
Switch Gears, powers panels D. B. And S.F. Us.
phase busbar, the Sizes of the bus bars shall be so selected that the current density in
bar does not exceed 150 amps, per sq. m. for copper. The length of Dus-bar chamber
should be as suitable length to fix all the switches etc. as per the prevailing standards,
clear spacing of adjacent buses Sha!! be 1 a!2" minimum bar should be tasted a!!
along with colour coated 11 KV grade PVC tape The maximum internal of support for
each unsupported length shall exceed 600 mm.
The bus bar shall be of copper/alluminium and fabricated to the relevant standards
specification. In case alluminium bus bar is used special with high conductivity alluminium bus
bar alloy E 91 C frame conforming to E.S.S. 2898 shall be used. The current density shall not
exceed 800A per sq. inch. Hy!am barriers will be provided over the joints to prevent any short
The bus enclosing shall be made out not less than 16 gauge M. S. sheet construct on
with angle iron support. All interconnections between bus bars S. F Us and O. Bs shall be of
adequate size and details of such inter connection shall be furnished to the Engineer-in charge
for his approval.
The busbar shall be air insulated extensible type rectangular one. The bus bars chamber shall
be dust tight by providing gaskets secured property so as to tender it veritin proof.
The combination fuse switch unit should comply with IS 4064 BSS61 and BBS 2510 wherever
applicable. It should be suitable to accommodate High Rupturing capacity cartridge Fuse links
complying with IS 2208 cr BS 88 and having a certified rupturing capacity of not less than'
MVA at 4440 volts (ACS duly Q The switch gear (panrs D, Bs. etc. shall be installed generally
as per is-Part -1 3072 and as specified and shown in drawings.
All fuse switch units shall be provided with, non-deteriorating HRC fuse links complying with IS
2208-1962 and having rupturing capacity of 35 WA at 415 volts or as specified.
switches above 60 amps, rating shall be provided with suitable size adapted boxes. Ali
switches mounted-on the top of the busbars Sha!! be provided ,with detachab!e type reverse
entry adapter boxes. Suitably engraved tables shall be provided for each circuits as well as for
A meters sector switches and LMH meter shall be provided where. specifically
mentioned. Small wiring for the inter-connecting shall be colour coded and provided with
numbered teuses for easy identification of circuits.
The distribution boards should be tcta!ly enclosed metal clad complying with B. S.
the M. S. sheet steel enclosures for recessed D. Bs. shall be of not less than 14 gauge.
(b) The D. B. shall be with hindod dooi and the locking arrangements as approved by the
Engineer-in-charge.
(c) All the components shall be enclosed in the enclosure. The mounting of D. B. shall be
got approved by the Engineer-in-charge before carrying out the installation.
(d) The D. Bs shall have proper side-cut outs for conduits entry or cable entry as required
and these shall be made on site
Adequate spacing shall be provided inside the D Bs. for easy removal of the fuses and
carry out the interconnection.
(f) A set of insulating bamers have to be provided between incoming breakers switches and
Switch fuse Units:
D.P.T.P.and T. PN. Switch fuse units shall be totally enclosed iron a clad quick
make, quick break type to best Indian make conforming to the I.S. or S.
specifications. A!! the switch fuse units Sha!! have mechanical Interlock with a door sc
that the door so that the door cannot be opened when the swatches
are in ON position.
The switch should be of double be solution type to ensure safely.
(b) Each T.P & T.PN switch fuse unit shall be earthed with two distinct each connections.
(c) Suitable insulator shall be provided between phase.
(d) There shall be suitable natural link in the fuse box.
All T.P and T.PN: switch fuse
units snail be rated for 500 volts and D.P, (required for
single phase supply) and S.PN. switches for 250 volts.
(O The H.HC. catndge fuse shall conform to U.S. 88 (1952).
The O.C.Bs. ACS Shal! be suitable for 400/440 volts 3 phase escapable of interrupting a
fault MVA of not less than 31. The circuit breaker shall conform to the BSS-936 1940. BSS
with such tripping arrangement as
may as required under special specification is for the
building. Efficient and fool -
proof mechanical interlocking shall be provided for the safe
operation and maintenance. The rate be inclusive of the first filling of oil.
2.7 Instrumentation:
Tile instruments and meters wherever necessary shall be housed in special sheet steel
box located between switch fuses units and bus bar chambers. The instruments etc. shall be
mounted on the hinged cover with heir dial flushed. All instruments shall have protective H. R.C.
fuse links. All interconnections and small wiring shall be neatly dressed arranged and duly
coloured 1 Or easy identification of circuits.
Meters shall be provided as required in the Schedule, Meters shall be dead head and be
suitable for 400/ 440 volt 3 phase 4 wire 50 c/cie (in balanced load) supply.
Each section switch shall be 3 point and of minimum 250 volts grade with silver tipped
contact suitable for metering circuits, current transformers shall be of 5VA burden and
commercia! metering accuracy. Indication lamps she!! be penal mounting type preferably of
250V grade. Every unit shall be prewired and interconnected to the system for its required
indicating performance. Indicating lamps shall have independent circuit fuse.
2.8 FIXING OF LIGHTING FIXTURES:
1. Location of fixtures their manner of fixing mounting height etc. are indicated in relevant
drawing. Actual location and levels shall however be arrived at site in co-ordination with
other service etc. and prior approval of the Engineer-in-charge regarding the actual
location Manner of fixing shall be obtained before the work is taken up in hand.
cases the contractor shall provide necessary interconnection wiring earthing
painting etc. all necessary for complete instolation. The contractor shall also test and
commission the fixtures during completion of the work.
3. Genera! arrangement of fixtures layout is indicated in drewings. Care Sha!! be taken to
see that all light fixtures are in a row in a room or particular area, are in absolute line and
plump and are symmetrically disposed with respect to finished surfaces of walls,
columns beams etc.
4. The inter-connections wiring from the light outlet point upto the fixture shall be carried
out by means of flexible copper wire of section not less than 1.5 mm2.
All fixtures suspended by
5. means of conduits shall be done with all and socket joints or
as per approved design.
2.9 Telephone system:
1. Empty conducing shall be done recessed or exposed to surface along with pulls boxes,
junction boxes and telephone outlet boxes, in areas. and location as indicated in the
relevant drawing as per materials and methods as described in regard to conducting
under section "Wiring in conduits" except the G.I. pull wires of gauge not less than
SWG shall be dept pulled through conduits in all sections so that in future telephone
wires can be pullet. easy.
2. Location shown on the drawing are proximate and final location shall be decided in the
fieid by the Engineer-in charge.
SPECIFICATION FOR EARTHING &
Installation of Earthing Plates:.
All installation of earthing shall conform to Indian Electricity Rules, IS -
edition and I.E.E. the copper earth plates should be tinned before installation. the earth
plates of copper 60 cm x 60 cm x 3.515 mm thick size as mentioned in the schedule be
in separate pits at least 150 cms to 300 cms. away from the building at a depth
necessary to reach moist earth surface but with a minimum depth of 2.5 Mtr from the
finished ground Level upto the top vertical dodge of earth electrode. The earth plate shall
be thoroughly cleaned to remove all dirt from the surface and be tinned property for
electrical contact with the main ground. Each earth pit should be provided with 38 mm.
dia . G.!. pipe 2.5 Mts.long or more depending upto the depth of pit, put over the vertical
edge of earth plate (with top end of pipe provided with a closed to couyler.) Alternative
layers of salt and coke shall be provided surrounding the plate. The pits shall be filled
when the plates are in position and with the approval of Engineer-in-charge.
To facilitate watering the pit, a concrete compartment should be made-with funnel with
mesh and cover plate as per rules provide in ISI regulation. The masonry endorser's
shall be 25 cm x 25cm x 25 cm (deep) with C.I, lid of 23 cm x 30 cm x30 cms. size. After
installation, the earthing resistance of each earth plate should be measured by
resistance meggar in the presence of Engineer-in-charge, three days after the
completion of earthing work, and the value should conform to regulations.
Signature of contractors Executive Engineer,
1.0 Energy Saving Concept.
1. For Indoor and Outdoor Lighting, Energy Saving Fittings are proposed in the SOR
and shali be preferred mostly
2. Selection of Fittings & Lamps shall be made after obsening required optimum
illumination level of the place.
3. For internal wiring of the switchgear pannels specialized fireproof wi-es included in
the SOR shall be used.
4. For selection of pump sets, storage capacity usage of water quantity & head shall be
considered for. required optimum HP of Motor pump Sets.
5. For the Corridors and Passage Lighting in general office buildings CFL I Energy
Saving fitting shall be preferred.
6. For Routine Maintenance of Motor Pump. Sets, Window and Split Type A.C.
Machines, Fans, Water Coolers and Geysers yearly comprehensive maintenance
cost is included in the SOR and shall be put in use widely for avoiding piece work
7. For Point wiring above 10 Mtr of length, addition length will be added at rate of
8. For point wiring In bathroom and WIC in residental quarters reduce overall rate by
50% of point wiring for light,3
9. For E.I. work in Highly Security restricted areas like Jails, V.V.I. P. Residences, add
of overall cost of estimate,
2.0 Rates for electrical installation work In Isolated places be enhanced by the
percentage given as under
Dangs and Ketch Districts
(Except 01st Head
(iii) Outside Gujarat State +30 %
3.0 Rental charges for temporary Electrical Installation works:
Full rate shall be paid for the first day at 10% of capital cost for packed new items &
for used materials 6% of capital cost of the complete item shall be taken.
50% rate of first day, rate shall be paid for second day.
(iii) 10% of first day's rate shall be paid for subsequent days or part there of beyond two
4.0 APPROVAL OF MATERIALS:
4.1 When category wise Materials are available the same should be used for Electrical
Installation works.
4.2 Table Showing categories of the materials to be used In Residential Buildings.
Type of Residential Category of Category on
buildings. services material
(1) Category 'E' type
Quarts. &"Category's"
(2) Category 'C' & 'D' type II
Orts. & Category
"IV' type qrts.
(3) Category' A' &'B' type I
Qrts. & Category
"II" type qrts.
4.3 Table showing categories of
materials be used
to In N.R. Bldg.
Type of Non-Resi- Category of Category Of
entail buildings. services material
(1) VIP chambers,
(2) M.S.Buiidings,
Laboratories, X-Ray
Machines, Central
Air-conditioning Plants,
Circuit Houses etc.
(3) For Non Residential ii
buildings other than
(4) Common passages, II
stairs, toilets etc.
4.4.1 list of approved materials under each category-should be enclosed with the tender
documents and the Tenderer should mention the brand name of materiai selected for
use in the said tender and the same should be finalized before acceptance of the
tender. Placing of the order for such category materials should be started after
acceptance of the tender. At the time of recording measurements in the
measurement book, specific brand name of actual make of material used should be
written in place of approved make borne on the list approved materials.
5.0 NCN S.O.R. ITEMS:
Rates for items Viz. Transformer, Lifts, Air-conditioning plants are based on the
capacity and ,design parameters adopted by the different firm depending on R & D
workshop collaborations. These items are not very frequently used for Electrical Installation
works, so the budgetary price should be considered while preparing the estimate and the
D.T.R For such Non S.O.R. items the changes of capacity, for different makes while framing
the estimate market price shou!d be ascertained from reputed manufactures inc!uding the
price escalation likely to occur between preparation of the estimate and the actual tender.
Non S.O.R. items which are required to be used frequently should be proposed by the field
officers for inclusion for ensuing S.D.R. 1997-98. All the proposals or modification in the
existing S.O.R. items should be proposed along with supporting data before the end of
6.0 LIST OF APPROVED MATERAILS
The makes of following accessories, equipments. switch gears etc. are approved for
use on E.I. works (Surface I Concealed) in this Deptt., subject to the condition that the said
materials do confirm to requisite I.S.S. requirements or do have I.S.I. Certification/ I.S.I.
Marks. The brand names & material on list are applicable only for use on works by
contractors and in departmentai tendering works for procurement directiy on works by offices
of this department. In respect of purchase under D.G.S.& D. Rate Contract. the rate contract
shall hold good.
Any material required for use on works etc. and not on list shown with S.D.R. shall be
approved by the appropriate authority of the Department, looking to the merits of use. This
shall be witnin preview of concerned Executive
Engineer (E) & Superintending Engineer (E)
as shown in tender clauses.
7.0. Approval of Materials on Work:
The Samples of Materials to be used in a work should be approved by the officer not
below the rank of Executive Engineer (Electrical; and an entry should be mac'e in register of
materials for this purpose oniy and the samples should be retained by department For any;
one work onu brand to be approved for use.
The Section officer (A.E / A. A. E.) in charge of work should remain present during
the execution of item of earthing and the certificate to the effect should be given accordingly
and be preserved in Sub-Divisional Office with record of such work.
9.0 Laying of pipes for concealed works:
For the concealed wiring in large buildings where the formalities far sanction and tendering
works may delay the laying of concealed pipes along with the civil works will be carried out
departmentally. The rates for pipes are given in the S.O.R. The concealed pipes must be laid
along with 16 Gauge fish wire. No reduced rates shall be proposed for deletion of fish wires.
Zero measurements shall be proposed for such cases.
For the remaining works of wiring in existing pipes, the rates shall be adopted as per
the items mentioned in this S.O.R. which includes the wires, accessories, laminated sheets
and remaining all except pipe.
Sign. Of Contactor
Deputy Executive Engineer Executive Engineer
Electrical (R&B) sub division Mehsana Electrical R&B Division
Palanpur Mehsana
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
FREQUENCY FOR TESTING OF MATERIALS
For ensuring quality control and workmanship. Various tests prescribed below for materials shall be taken at periodical
intervals as stipulated below.
The materials shall be a got tested at Government recognized Laboratory, (R & B) or field Laboratory of GERI ( R & B) for
which 1% of the estimated amount put to Tender shall be recovered from the contractor from the R. A. bills and final bills
at the testing charges shall be paid to the GERI by the Government. However if the charges increase over 1% no excess
recovery shall be made from the con-tractor as per resolution of B & C Department dated 10th May 1985 Vide TNC/1085
Item No Brief Qty. of Material Unit Prescription of test Frequency @ which Total No. of
as per Description of which shall be test shall be carried Test to be
schedule Materials to carried out out taken
Upto 50 T 1 test
Consistency, setting 200-300 T 4 test
time, compressive
300- 500T 5test
Cement 1051.70 MT strength, fineness, 500 -
Chemical analysis 800 -1300T 7 test
Soundness and 8 test for larger
1469.24 Gradation test 1 to 100- 1 test
Impact Value 100 to 500-3 tests
CMT Flakiness Index of 500 to 1500-5 tests
Special gravity
Water absorption
4 Sand 2850.76 CMT Fineness Modulus 1 Test
Water absorption
5 Bricks 374350.00 Nos Size 1 Test
@ 50,000 Bricks
Tensile strength,
1/40 tonnes / per
6 Steel 209.97 yield stress,
1 To 5 Cum. I No.
8 6 to 15 Cum. 2Nos.
16 to 20 Cum. 3Nos.
21 to 50 Cum. 4Nos.
51 & Above Cum 4+
9 M250 939.70 CMT for each 50 Cum or part
11 Water Lum Lum Chemical Anal sis 1 Test for work
12 Soil 3558.10 Cmt OMC
Density I Test for work
Water Absorption
Upto 100 cmt - 1 Test
Upto 500 cmt - 3 Test
GSR 325.90 Cmt Flakiness Index and
Upto 1500 cmt - 5 Test
elongation index
Upto 5000 cmt - 7 Test
Deputy ecutive Engineer Executi Engineer
Road & Building Sub Division Road & Building Division
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Excavation for foundation upto 1.5 M depth including sorting out and
stacking of useful materials and disposing of the excavated stuff upto 50 M
lead (A) Loose And Soft Soil Hundred Twenty
1490.60 Cum 122.93 Two and Paise
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
out and stacking of useful materials and disposing off the excavated stuff
upto 50 Meter lead.(B) Dense or Hard soil 1009.00 Cum
Hundred Seventy
and Paise Forty
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting Rupees Three
3 out and stacking of useful materials and disposing of the excavated stuff 319.00 Cum 300.02 Hundred and
u to 50 Meter lead. C
Hard Murrum. Paise Two Onl
Providing and laying rubble soling in foundation includiing watering and Rupees One
ramming complete as per structural design and depth as directed by Thousand Two
4 Enginee-ln-Charge, 159.10 Cum 1268.56 Hundred Sixty
Eight and Paise
Providing and laying controlled cement concrete M.150 for curing complete
including cost of formwork and reinforcement for reinforced concrete work
in (A) pcc Thousand Nine
Hundred Seventy
269.40 Five and Paise
Providing and laying controlled cement concrete M-250 and curing
complete including the cost of form work but excluding the cost of Rupees Four
reinforcement for reinforced concrete work in foundation footings, Raft, Thousand Six
base of columns and mass concrete. 490.70 Cum 4622.45 Hundred Twenty
Forty Five Only
Providing and laying controlled cement concrete M-250 and curing Rupees Six
complete including the cost of form work but excluding the cost of Thousand One
7 reinforcement for reinforced concrete work in Plinth BEAMS. 148.50 Cum 6146.61 Hundred Forty
Providing and laying controlled cement concrete M-250 and curing
complete including the cost of form work but excluding the cost of Rupees Seven
reinforcement for reinforced concrete work in Columns, pillars posts and Thousand Eight
8 Hundred Ninety
struts For Plinth Column. 36.20 cum 7891.87
Applying general insecticide pest control treatmentto floors, cupboards etc
including labour materials etc.complete. Using Imidacloprid 30.5 SCas Per
IS Rupees Ninety
9 6313 part-II( (0.075% concentration by mass) is ecommended 10.5ml
827.60 Sqm 91.62 One and Paise
chemical diluted with 5 liters of water application 0.5 litre chemical /Sqm
of surface is recommended as Sixty Two Only
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete.
10 Hundred Eighty
Filling available excavated earth (excluding rock) in trenches. plinth, sides
of foundations etc. in layers not exceeding 20 cm. in depth consolidating Rupees One
11 each disposited layer by ramming and watering 1794.40 Cum
Ninety One Only
Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
Filling in foundation and plinth with murrum or selected soil in layers of
thickness including watering, ramming and consolidating etc. Rupees Two
complete. Hundred Ninety
Thirty Eight Only
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of Rupees Six
reinforcement for reinforced concrete work in Ground Floor Bemas. Thousand Two
13 129.50 Cum 6289.54 Hundred Eighty
Fifty Four Only
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in FF SF Beam.
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns, pillars posts and
15 61.20 Cum 7839.86 Hundred Thirty
struts For Ground Floor.
Eighty Six Only
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns, pillars posts and
16 43.00 Cum 7880.97 Hundred Eighty
struts. For First Floor
and Paise Ninety
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns, pillars posts and
37.00 Cum 7922.09 Hundred Twenty
struts. For Second Floor
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of Rupees Six
reinforcement for reinforced concrete work in Ground Floor Slab. Thousand Three
18 127.00 Cum 6347.81 Hundred Forty
Seven and Paise
Eighty One Only
Providing and laying controlled cement concrete M-200 and curing Rupees Six
complete including the cost of form work but excluding the cost of Thousand Four
19 reinforcement for reinforced concrete work in FF and SF Slab. 206.00 Cum 6409.50 Hundred Nine
and Paise Fifty
Brick work using common burnt clay building bricks having crushing Rupees Four
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Thousand Two
Mortar (1- Cement:6 -fine sand)(B) Conventional Plinth Brick Work. Hundred
Paise Thirty Two
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:5. (1- Cement : 6 -fine Conventional (For Ground Floor)
235.00 Cum 4496.04 Hundred Ninety
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit
In Figure In Words Amount
Brick work using common burnt clay building bricks having crushing Rupees Four
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Thousand Five
Mortar 1:6 (1- Cement -fine sand)(B) Conventional (for First Floor) Hundred Thirty
Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar (1- Cement: 4 -
coarse sand ) in foundation and plinth (B) Conventional (For Ground Floor) Hundred Eighty
Twenty Six Only
Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement: 4 -
24 coarse sand ) in foundation and plinth (B) Conventional 598.00 Sqm 690.56 412954.8B
and Paise Fifty
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of Rupees Seven
reinforcement for reinforced concrete work in Ground Floor Lintels. Thousand Seven
25 9.90 7733.60 Hundred Thirty
Three and Paise
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of Rupees Seven
reinforcement for reinforced concrete work in First Floor Lintels. Thousand Seven
Hundred Seventy
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Second Floor Lintels.
8.30 Cum 7815.83 Hundred Fifteen
and Paise Eighty
Providing and laying controlled cement concrete M-200 for reinforced
concrete CHHAJJAS not exceeding 10 cm. Thickness up to floor two level
including finishing to give a smooth surface centering and form work and
10.90 Cum 6620.51 Hundred Twenty
curing complete excluding cost of reinforcement.For All Floor
and Paise Fifty
Providing and laying Controlled C.C. M-200 (C.C. -
coarse snad, 3 graded stone agggregate of 20 mm nominal size) and curing
complete including the cost of formwork and excluding the cost of
29 42.30 Cum 7440.95 Hundred Forty
reinforcement for reinforced concrete work for horizontal and vertical
and Paise Ninety
Providing and laying controlled cement concrete M-200 and curing
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in STAIRCASE For All Floor
30 11.00 7483.72 Hundred Eighty
Three and Paise
Providing TMT Bar FE 500D reinforcement for R.C.C.work including
bending, binding and placing in position complete upto floor two level.
Seven and Paise
Name of Work . Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing 20mm thick Smooth Cement plaster in Tow coat on single or
brick walls for interior plastering upto floor two level and finished even and Rupees Two
32 smooth in (iii) 12mm thick backing coat of C.M. 1:3 (I-cement : 3-sand) and Hundred Fifty
8mm thick finishing coat of C.M. (I-cement : I-sand) etc. complete.
Ground Floor Five only
Providing 20mm thick Smooth Cement plaster in Tow coat on single or
brick walls for interior plastering upto floor two level and finished even and Rupees Two
33 smooth in (iii) 12mm thick backing coat of C.M. (I-cement : 3-sand) and 2118.20 sqm
Hundred Seventy
Seven and Paise
8mm thick finishing coat of C.M. 1:1 (I-cement : I-sand) etc. complete (For
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in Rupees Two
(i)Cement mortar Hundred Two
(I-cement:3-sand) finishing with a floating coat of
34 834.90 Sqm 202.28 and Paise
neat cement slurry.plastering on ceilings and sofits of stairs upto floor two
level instead of plastering walls.) (For GF) Twenty Eight
Providing 1 Omm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor
two level and finished even and smooth in Rupees Two
(i)Cement mortar 1:3 (I-cement:3-sand) finishing with a floating coat of Hundred Twenty
neat cement slurry.plastering on ceilings and sofits of stairs upto floor two
level instead of plastering on walls.) (For FF + SF) Thirty Four Only
20mm thick Gutka cement plaster on walls upto height 10 metres above
ground level consisting of 12mm thick backing coat of C.M. 1:3 (I-cement: 3- Rupees Three
36 sand) and 8mm thick finishing coat of C.M.I:I (I-cement: I-sand) 3970.80 Sqm
etc.complete, Two and Paise
Forty Three Only
Providing 12mm wide groove /notch as per design in plaster including
finishing the same etc complete for all height. Rupees Twenty
Providing and laying Green granite slab flooring treads of steps and landing
over 20mm (average)base of cement mortar (I-cement : 6 coarse sand)
38 or LM. lime putty : 1.5 coarse sand) laid and jointed with gray
72.70 Sqm 2244.86 Hundred Forty
cement slurry including rubbing and polishing complete. (A) Granite Marble
slab 20mm to 25mm thick Four and Paise
Eighty Six Only
Providing and laying Granite slab 18 mm in jambs & sill of door and
windows (all edge machine cut and rounding mirror polished ) of approved
shade and applying coarse-cum-fine sand on the back side of the marblr Rupees Two
with approved adhesive like Araldite or eq. to make the surface rough for Thousand Eight
better bonding with the wall surface on 10 mm thick cement mortat 1:3 (1 Hundred Fifty
:cement : 3-coarse sand) laid and jointed with cement slurry including
rubbbing and polishing complete as directed by Engineer in Charge. Twenty Six Only
Providing and laying 24" x 24" Soluble salt vitrified 8 mm thick tile flooring
over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand)
on new surface or fixing on existing flooring by adhesive material including
40 1690.00 Sqm 1529.14 Hundred Twenty
jointed with Epoxy Grouting including finised with flush pointing & cleaning
the surface etc. complete for light shade And 10% off Dark Nine and Paise
Providing and laying 24" X 24" Soluble salt vitrified 8 to IO mm thick in
skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1- Rupees One
cement : 3-coarse sand) and jointed with Epoxy Grouting.complete for light
88.00 Sqm 1809.92 Hundred Nine
shade And 10% off Dark Colour.
and Paise Ninety
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BLL QF QUANTITIES
Item Quantities Unit
Item Description In Figure In Words Amount
Providing and laying 600mm x 1200mm Soluble salt vitrified 8 to IO mm
thick in skrting risers of steps and dedo on 10mm thick cement plaster 1:3
(I-cement : 3-coarse sand) and jointed with Epoxy Grouting.complete for
42 lightshade And 10% off Dark Colour. 41.00 Sqm
& L 24" x 24" Mattantiskit Porcelain 8 mm thick tile flooring over 20 mm Rupees One
(average) base of cement mortar (
cement: 6 coarse sand) on new Thousand Four
surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with Epoxy Grouting including Seven and Paise
finised with flush pointing & cleaning the surface etc. complete for Matt Seventy Two
antiskit Porcelain. Onl
Providing and laying Matt Finished Antiskid Ceramic (300mm X 300mm) Rupees One
tiles 6mm thick in flooring treads of steps and landing laid on a bed of Thousand Two
44 12mm thick cement mortar 1:3 (I-cement: 3-coarse sand )
finishing with 57.00 Sqm 1258.46 Hundred Fifty
flush pointing in jointed with Epoxy Grouting. Eightand Paise
Providing and laying coloured glazed tiles of the size 300 mm x 600 mm x
mm in skirting, risers
of steps and dedo
on 10 mm. thick cement plaster Rupees One
(1 cement : 3 coarse sand) &jointed with white cement slurry. Thousand Four
45 540.00 Sqm 1491.26 Hundred Ninety
Twenty Six Only
Providing and laying 24" x 24" Full Body vitrified Steptiles 8 mm thick tile
flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement; 6 Thousand Five
coarse sand) on new surface or fixing on existing flooring by adhesive 54.00 Sqm
46 Hundred Six and
material including jointed with Epoxy Grouting including finised with flush
pointing & cleaning the surface etc.
Providing and laying 24" x 24" Full Body vitrified Steptiles 8 to 10 mm thick
,in skrting risers of steps and dedo on 10mm thick cement plaster (1- Rupees One
cement : 3-coarse sand) and jointed with Epoxy Grouting .complete for light Thousand Seven
shade And off Dark Colour. Hundred Eighty
Eight and Paise
Providing and laying broken chine mosaic flooring for terrace using 12 mm
to20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to Rupees Seven
plain or slope and to be tempered to bring mortar creme out upto surface Hundred Seventy
using white cement including rounding off junctions and extending them Nine and Paise
upto 15 cm along the wall,clearing with water and oxalic acid etc. as Sixty Nine Only
Constructing a sandwich type platform of the top of platform is 18mm thick
black granite fixed with Cement morter on 25 mm thick single side
polish kota stone The platform kota stone resting on both side polished
25mm thick Kotah stones, including making zari in wall and inserting both Thousand Five
49 platform and vertical stone 25mm inside the wall, the facia patti shall be 12.90 Sqm 4591.46 Hundred Ninety
cms wide Moulded black granite, to be constructed as per drg and as One and Paise
per the instruction of Engineer
in-charge. Measurement to be considered
as plan area of platform.
Providing and fixing M.S. grills/ Railing of required pattern to M.S.
frames of windows ,Door Jali etc. with M.S. flats at required spacings and
50 frame alround, square or round Bright bars of 16mm dia, with round 7559.00 120.31
and Paise Thirty
headed bolts and nuts or by screws including all Fixture etc complete as One Only
directed b En •neer in char e
Applying two coats of putty & two coats of primer of approved brand and
manufacture on new wall surface and Ceiling to give an even shade Rupees Forty
51 including thoroughly brushing the surface free from mortar dropping and 5737.60 Sqm 40.59 and Paise Fifty
other foreign matter and sand papered smooth. Nine Only
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
ELL QF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
Wall painting (two coats) with plastic emulsion paint of approved brand
and manufacture on undecorated wall surface and Ceiling to give an even
52 shade including throughly brushing the surface free from mortar droppings 5737.60 Sqm 125.40
and other foreign matter and sand papered smooth.
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly brushing
53 the surface to
dirt, and remains of loose powdered 3970.80 Sqm 120.26
materials.etccomplete
Twenty Six Only
Providing and fixing chromium plated brass Jet spray heavy duty with S.S.
Braided hose 60 cm long comman with flange of approved quality including
54 fixing in pipe line etc complete. 15.00 Each 696.90
Providing and fixing chromium plated brass Angle cock comman with Rupees Eight
flange of approved quality including fixing in pipe line etc complete 15mm Hundred
Dia. Thirteen and
Providing and fixing chromium plated brass half turn flush cock including
fixing in pipe line etc. complete.(ii) 25mm dia.
Providing and fixing 600mm x 450mm bevelled edge mirrror of superior Rupees Eight
glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to Hundred Fifty
wooden plugs with C.P, brass screws and washers. Nine and Paise
Providing and fixing C.P. brass towel rail complete with C.P. brass brackets
fixed to wooden plugs With C.P. brass screws.(B) 600mm x 20mm size.
Hundred Sixteen
3.00 and Paise Forty
Providing and fixing chromium plated brass half turn Bib cock including
fixing in pipe line etc. complete.(ii) 15mm dia.
59 30.00 Each 1277.65 Hundred Seventy
Seven and Paise
Sixty Five Only
Providing and fixing water closetsquatting Pan (Indian type W.C. Pan) size
580mm (Earthwork, bed congrete, foot reste and trap to be measured and
paid for separately) (A) Vitreous China.(l) Long pattern = White colour
(Providing and fixing 100mm size P or S trap for water closet squatting pan Rupees One
including jointing the trap with the pan and soil pipe in cement Mortar 1:1 Thousand Four
60 (I-Cement : I-Fine sand)(A) Vitreous China.) ( Providing and fixing in 9.00 Each 1458.04 Hundred Fifty
Cement Mortar (1- Cement : 3-coarse sand)a, pair of white vitreous Eight and Paise
China 250mm x 130mm x 30mm footrest to long pattern squatting pan Four Only
water closet.) ( Providing and fixing G.I. inlet connection for flush pipe with
Providing and fixing wsh down water closet (European type, W.C. Pan) with
integral P or S trap including jointing the trap with soil pipe in Cement
Mortar (I-Cement : I-fine sand) (Seal and cover to be measured and
paid for separately) (A) vitreous China Pattern :(i) in white colour (
Providing and fixing in position with clamps etc. 32mm nominal internal
diameter galvanised steel tube flush pipe for high level flushing cistern
61 15.00 Each 1900.36 Hundred and
including connecting the flush pipe with cistern and closet and making good
Paise Thirty Six
the walls and floors.) (Providing and fixing G.I. inlet connection for flush
pipe with W.C. Pan) ( Providing and fixing plastic seat and cover for wash
down water closer With C.P. brass hinges and rubber buffers. (B) Black
plastic seal and cover.)
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing and fixing PVC SWR Nahni trap IS 14735 for drain 100 mm
diameter with jali of the following nominal diameter of self cleansing design Hundred Eighty
62 with C.I scread down or hinged grating including the cost of cutting and 27.00 Each 586.27 Six and Paise
making good the walls. Twenty Seven
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber
and water tight C.I. cover with frame of 300mm x 300mm size (inside) with Rupees One
standard weight. (i) Square mouth traps.(B) 150mm x 100mm size P or R
63 12.00 Nos 1246.91 Hundred Forty
Ninety One Only
Providing and fixing Square Stainless Steel Bathroom Jali, Size: 6x6 Inch
approved quality including fixing in pipe line etc complete.
64 33.00 Each 429.25 Nine and Paise
Providing and fixing plated brass half turn Twoway Bib cock with fixing in
pipe line of standard quality as directed by engineer in charge including all
materials and labours etc complete..(i) 15mm dia.
65 24.00 Each 1962.43 Hundred Sixty
Forty Three Only
Providing and fixing Swan neck type with swivel spout pillar cock with Rupees One
hook with fitting of standard quality as directed by engineer in charge Thousand Six
66 including all materials and labours etc complete. (i) 15mm 9.00 Each 1626.10 Hundred Twenty
Six and Paise Ten
Providing laying and jointing in true line and level 15mm dia. U.P.V.C, Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two Rupees Seventy
67 metre C/C or shall be concealed as directed including necessary fittings etc. 195.00 Rmt 72.64 Two and Paise
including testing of pipe and joints and fixing the same with adhesive Sixty Four Only
solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two Rupees Ninety
68 metre C/C or shall be concealed as directed including necessary fittings etc. 255.00 Rmt 91.83
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe (
SCH- 40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
69 metre C/C or shall be concealed as directed including necessary fittings etc. 300,00 Rmt 195.66
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials. Sixty Six Only
Providing, laying and jointing in true line and level 110 diametre U.P.V.C
(Type B) conforming to IS 13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall using of PVC
Hundred Seventy
clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at 773.12 Rmt 876.90
every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of
Providing erecting and fixing double coated ISI water tank of required
capacity each with all necessary fittings and connection etc. complete on
71 15000.00 Liters 3.94 and Paise Ninety
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit
In Figure In Words Amount
Providing and fixing Table Top washbasin with single hole for pillar tap
with C.I. or M,S. brackets painted white including sutting holes and making
good the same but excluding fittings.(A) Vitreous washbasin
mm x 625 mm size. (i) In white colour. (Providing and
fixing C.P. brass
waste for washbasin or sink. (B) 40mm dia.) (Providing and fixing M.I. Nos
72 21,00 Hundred Forty
fisher union for washbasin or sink. (A) 32mm dia.) (Providing and fixing
pillar tap, capstan head,
screw down high pressure with screws, shanks and Fifty Eight Only
back nuts. (i) 15mm dia.) ( Providing and fixing brass screw down stop
tap.(A) 15mm dia.)
Providing and fixing Urinal of approved quality connecting the Urinal with Rupees One
waste pipe trap etc.complete. (A)White earthen ware flat back or corner Thousand
73 type size 430mm x 260mm x 350mm 12.00 Each 1074.86 Seventy Four
and Paise Eighty
Constructing brick masonry chamber for underground C.I. Inspection
chamber and bends with bricks having crushing strength not less than
35Kg/Cm2 in C.M. 1:5 cover with frame (Light duty) 455mm x 610mm
intenal dimensions total weight of cover with frame to be not less than Rupees Two
38Kg. (Wt. of cover 23Kg. and Wt. of frame 15Kg.) R.C.C. top slab with 1:2:4 Thousand Nine
74 mix (I-cement: 2-coarse sand: 4-graded stone aggregate 20mm nominal 23.00 Each 2932.92 Hundred Thirty
size)foundation concrete inside plaster 5mm thick with cement Two and Paise
mortar 1:3 finished smooth with a floating coat of neat cement on walls and Ninety Two Only
bed concrete etc. complete. (i) Inside dimensions 455mm x 610mm x
450mm deep for single pipe line
Providing and fixing Double shutter door Anodized aluminium section
frame and entrance door with floor spring and pivoted shutter made from
Rails covered with
cmx 15 cm. Styles and 6 nos. cms. X cms. T.W.
75 41.30 Sqm 5545.49 Hundred Forty
mm thick water proof
6 ply finished with both sides laminates. Colour and
shade approved by architect. 60 cms long s.s. Handel on both shutter. Forty Nine Only
Providing and fixing Single Shutter anodized aluminium section frame -
weight not less than 1.1 kg/Mt with wooden inserts for durable grip of door Rupees Five
hinges (frame size 38 mm x 63.5 mm) single 3.8 cm thick shutter flush door Thousand Five
core finished With mm th. lamination on both side with s.s. handle
1 107.10 Sqm Hundred Seventy
and other s.s. fixtures single shutter and fully panelled shutters including Four and Paise
s.s. pivote hinges handles with locking arrangement, etc. complete. Nineteen Only
Providing and fixing Single Shutter FRP frame size 100x50 mm and 35mm
thick FRP depress panel shutter having extra reinforcement on sides &
edges in Gel coat finish. The core of the shutter & frame is to be filed up
with injected fire retardant grade polyurethene foam done in situ alongwith
embedded wooden pieces for stiffening & also taking hinges & fintures. The
33.10 Sqm 2377.76 Hundred Seventy
whole FRP frame & shutter is to be water proofweather proof, termite
Seven and Paise
proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges
Seventy Six Only
with necessary screws & alluminium fixtures & fastenings & fastener sleeve,
Providing and fixing Double Shutter FRP frame size 100x50 mm and 35mm
thick FRP depress panel shutter having extra reinforcement on sides &
edges in Gel coat finish. The core of the shutter & frame is to be filed up
with injected fire retardant grade polyurethene foam done in situ alongwith
embedded wooden pieces for stiffening & also taking hinges & fintures. The
78 7.60 Sqm 2882.76 Hundred Eighty
whole FRP frame & shutter is to be water proof weather proof, termite
proof & resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges
Seventy Six Only
with necessary screws & alluminium fixtures & fastenings & fastener sleeve.
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing & fixing Colour Anodised Alluminum sliding window system
Domel 27 series Three Track window as per shown in elevation with outer
frame section no.21401 @ Wt 1.591 Kg/Rmt& Sliding shutter style section Rupees Six
no 21481 @ Wt 1.02 Kg/ Rmt, interlock Section no. 19442 @ Wt 0.33 Kg/ Thousand Four
Rmt with fixing of 5 mm thick tranparent plain float glass with tranparent and Paise Forty
silicon sealant, Alluminium powder colour coated fiting with etc complete Three Only
as per instruction of Engineer in charge & approved make.
Providing & fixing of Casement window with single shutter fixed glass
above; alluminium extruded casement Window frame equivalent to series Rupees Two
Domel 27 series partition using aluminium section 47.2 X 44.45 X 2.17 mm
80 cleat 19 X 17.3 X 0.9 mm angle 25 X 25 X 2.00 mm Frosted 5 mm thick
120.80 Sqm 2984.91 Hundred Eighty
transparent float glass Rubber gasket including using all necessary anchor
bolts, wall plug,
screw, silicone etc complete as directed by Engineer Ninety One Only
Providing and fixing Coloured Anodised Alluminium sectional louvered
ventilator with frame size 60mm x 60mm/100mm x 30mm and 5mm thick
Bajari glass and Coloured anodised alluminum louvers fixture and hold
81 11.60 Sqm 2665.39 Hundred Sixty
fasting etc complete.
Thirty Nine Only
Providing and fixing standard extruded of alluminium section of size
63.50x38.10x1,95mm (@ Wt 1.094 Kg/Rmt) with colour Powder Coated
alluminium frame with 5 mm thick transparent bronze colour tinted float
82 glass as details etc complete for Fix Glass window. 65.60 Sqm
Three and Paise
Providing and fixing letters as per size,Design & Steel Colour Coted Later Rupees Four
material mention below Size including all labour & materials etc.complete. Hundred and
(i) 6" Height 400.97
Providing and fixing letters as per size,Design & Steel Colour Coted Later
material mention below Size including all labour & materials etc,complete.
84 (i) 18" Height 60.00 No 929.20 Hundred Twenty
Providing and fixing letters as per size,Design & Steel Colour Coted Later Rupees Six
material mention below Size including all labour & materials etc.complete. Hundred Ten
Providing and Fixing Name/Number Plate in 4 mm thick Acrylic sheet Rupees Nine
Sticked,writing and screw fitting as directed by Engineer in Charge. Hundred Fifty
Providing and fixing 90 cm high Stainless steel railing for Handicap made
from Anticorrosive S S pipe of 50 mm dia (16Gauge) as hand rail with S S
38 mm box pipe (16Gauge) as a vertical support fixed in RCC slab at 1.2m Rupees Two
c/c including welding, grinding, buffing, polishing and making
curvature Thousand Four
87 (wherever required) and fitting the same with necessary stainless steel 39.00 Rmt 2449.10 Hundred Forty
nuts and bolts complete fixing the railing with necessary accessories & Nine and Paise
stainless steel dash fasteners, stainless steel bolts etc complete as directed Ten only
by Engineer inharge.
Providing and fixing 90 cm high Stainless steel railing made from
anticorrocive S S pipe of 50 mm dia (16Gauge) as hand rail with SS 38 mm
dia (16Gauge) as a vertical support fixed in RCC slab at 1.2m c/c including Rupees Two
three horizontal S S pipes of 25 mm dia (16Gauge) at eqal distance fixed
88 40.00 Rmt 2426.86 Hundred Twenty
by 18.75 mm dia (16Gauge) S S pipe including accessories as per detailed
drawing as directed etc complete.
Eighty Six Only
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
Pro. And fixing single layer water proof gypsum board 12.5 mm thick
sections using water proof board of size 1220 mm x 1830 mm x 8.0 mm
suspended by GI suspender channel of size 25 mm x 3 mm with
intermediate channel og size 18 mm x 40 mm x 0.8 mm at 1220 mm center Rupees Six
to center ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm c/c Hundred Six and
and perimeter channel A of size 20 mm x 27 mm x 30 mm x 0.5 mm at edges Paise Ninety
& drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt Four Only
connecting cleat,joining compound top coat on ceiling incl.making
necy.opening for light fitting,diffuser etc. comp. as per detail drawing as
Providing and Fixing cattle trap at the entrance on gate including
excavation, P.C.C. in Mrick masonry 0.23 M. thick and 70 Cm. heigh in
C.M. 1:6, 15mm thick cement plasater in C.M. 1:4, Copping in C.C. 1:2:4, G.I.
90 14.40 Sqm 4650.04 Hundred Fifty
Pipe 50mm "C" class and M.S. plate 16mm x 60mm (Unit waight
kg/Rmt.) etc. Complete. as instructed by Engineer-In-Charge.
Providing supplying and fixing 114 mm wide gi sheet having thickness of
0.55 mm & weight not less than 490 gm/meter, roll formed to Create
mm wide louver snap fixed on special shaped
channel. Fix louvers &
channels shall Finished with powder coating of 55 micron. standard quality
91 45.90 Sqm 4387.44 Hundred Eighty
as directed by engineer in charge including all materials and labours etc
Seven and Paise
Forty Four Only
92 1000.00 House 199.98 Nine and Paise
Providing and Constructing a junction chamber of size 0.35 x 0.35 x 0.60 mt,
including connecting rainwater pipes, half brick work with plaster & C.C.
1:2:4 flooring bed 50mm and covered with RCC slab 100mm thick incl. all
93 16.00 1158.47 Hundred Fifty
labour, material, excavtion etc. complete.
Eight and Paise
Forty Seven Only
Brick Providing, laying and jointing in true line and level 160 mm dia.
U.P.V.C SWR (Type B) pipe conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring fittings conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be jointed
with each other with rubber lubricant, pipe shall be fixed on wall using of
94 Hundred Thirty
PVC clamp of the size 110mm dia x 149mm length x 145mm height at every 60.00 Rmt 834.38
2000mm center to center or shall be concealed in walls as directed
Thirty Eight Only
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of
Providing & Constructing filter chamber of size 2.06 x 1.21 x 1.20 mt.
including connecting rain water pipes, half brick work with plaster & C.C.
flooring bed 50mm and covered with RCC slab 100mm thick incl. all 1.00 No 11859,42 Hundred Fifty
labour, material, excavation etc. complete,
Providing & Constructing percolation sockwell of 2.54 mt internal clear Rupees Fifty
diameter and 5.00 mt depth including honey comb brick masonary in C.M. Nine Thousand
1:6, R.C.C. top slab of IO
cm thick filling with gravel etc. complete incl.
labour, material, excavation etc, complete. Fifty Eight and
Name of Work Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Steel work, welded in built up sections framed work including cutting,
hoisting,fixing in position and applying a priming coat of red lead paint.
(D)ln trusses and trussed purlins, upto 25 M. span and 15 M. ovarall height.
97 128.40 Qtl 10212.14 Hundred Twelve
Providing corrugated G.I. sheets roofing fixed with galvanized iron "J" or "L"
hooksbolts and nuts 8mm diameter with bitumen and G.I. limpet washers, Rupees Seven
98 filled with white lead complete excluding the cost of purlins rafters and Hundred Thirty
trusses (1) 0.80mm thick sheet
Providing and fixing pre-cast Rubber Dye inter locking concrete block
mm thick with grade of concrete M300 pnumatic compressed by Rupees Seven
mechanically pressed and as per approved design Conforming to IS Hundred Six and
15658:2006 including 35 mm sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC SP 63 : 2018 etc Two Only
Providing and fixing pre-cast concrete kerb stone of gray cement based
concrete block 30cm length,30cm height and 15cm thick of M 200 grade
100 concretas per approved design and including excavation for fixing in Hundred Four
proper line and level,filling the joint with C:M 1:3 (Icement:3fine sand) etc
Twenty One Only
Applying priming coat over new steel and other metal surface after over
and including preparing the surface by thoroughly cleaning oil, grease dirt Rupees Thirty
101 and other foreign matter and scoured with brushes fine steel wool, 428.00 Sqm 36.92 Six and Paise
and sand paper with ready mixed priming paint brushing red lead Ninety Two Only
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint brushing, interior to give enamel paint Rupees Ninety
brushing,interior to give an even shade including cleaning the surface of all 428.00 Sqm 92.20 Two and Paise
dirt, dust and other forei n matter Twenty Only
Providing and fixing M.S.Grills for Hollow Pipe 50X50mm framed Entry
gate/ Wicket gate/ gate etc Grill made of 25X25mm size Hollow M.S.Pipes
design as per Drawing welding pipes in frame incl. cutting, ransportion,
103 primer & oil painting, fixing in position etc. complete. 38.00 Sqm
Seven and Paise
Providing & fixing Rajor coil wire fencing having diameter of 0.75 mt
including using of M.S angle 45x45x6mm as per detail drawing, fixing in Rupees Seven
104 cement concrete M-200 etc completed with one coat of primer & two coats Hundred Fifty
of oil paint to M.S angle etc. complete as directed by engineer in charge. Four and Paise
Forty Seven Only
Earthwork cutting
sorts of soil and soft murrum including Rupees One
105 conveying and putting the stuff inspoilbank maintaining minimum distance Hundred Nine
offivemter between topedge and cutting and toe of spoil bank 1763.70 Cum 109.41
and Paise Forty
Construction of granular Sub base by providing GSB Grade-V coarse graded
material BTMC using aggregate 26.5 mm to 9.5 mm @ 64%, 9.5 mm to 4.75 Rupees One
mm @ 11% and stone dusts 4.75 mm and below @ 25% incl. spreading in Thousand Seven
106 uniform layers with motor grader on prepared surface mixing by mix in 148.00 1751.51 Hundred Fifty
place method with rotavator at OMC and compacting with vibratory roller One and Paise
to achieve the desired density complete as per Clause 401.2 Table 400.1 Fifty One Only
Construction of granular sub-base by providing close graded Material,
mixing in a mechanical mix plantat OMC, carriage of mixed Material to Rupees One
work site, spreading in uniform layers with motor grader on prepared Thousand Eight
surface and compacting with vibratory power roller to achieve the desired Hundred Twenty
density, complete as per clause 401 and Paise Sixty
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing and casting in situ ordinary cement concrete M-150 mix for well
steining including, necessary shuttring, laying vibrating and curing
108 136.00 Cum 4511.11 Hundred Eleven
and Paise Eleven
Providing and cast in situ vaccum De-watered unireinforced cement
concrete of Grade M-25-Trimix floring for average 25 cm thick wearing coat
pavement laid as directed in approved side form work including
vibrating by needle vibrator and leveling with trimix, surface vibrator,
Vaccum De-watering with trimix vaccum pump, floating and further
compaction, and finished in continous operation including cutting the
109 264.30 Cum 6869.16 Hundred Sixty
concrete with concrete cutting machine for contraction joints at every
mtr. and expansion joint at interval of 40 mtr. of size 6 x 12 mm to 12 x
mm deep or as specified/providingstripped/broom finish evenl, applying
debonding strips, bitumen primer, bituminous sealant' separation
membrane and curing etc. complete.
Drilling of 165 dia. Bore hole in overburden strata ( lime stone & yellow
sticly clay formation by DTH ring up to requird depth 6.00 mt. including
fixing 180.00 dia. PVC pipes ( blank and slotted ) if requierd uther drilling of Rupees Seven
165.00 mm dia. Bore hole in hard rock strata by DTH driling method up to 240.00 Rmt 756.49
total depth of 165.00 mt. incl. measureing the yield by "v" notch and
Forty Nine Only
flushing of bore etc. complete. (a) 0.0 to 300 mt. ( 165.00 mm dia bore )
Providing and supplying in standard length ISI mark rigid unplasticised PVC
pipes suitable for casing with ring fit joint including cost of rings as per IS
specification no 4985/1988 including all ocal and central taxes
transportation, freight charges, octroi, inspection charges, loading
111 6.00 Rmt 1458.44 Hundred Fifty
unloading, conveynce, to market and including cost of jointing meterial etc
Eight and Paise
complete for following dia. & ring fit type pipe. (B ) Test pressure 6.00 Kg /
Cm2 with excise duty. ( 7) 200.00 mm dia. Forty Four Only
Supplying, Fixing, Installation & Testing of approval make electric motor Rupees Thirty
driven submersible pump set confirming to IS 8034 / 198 / AND motor Five Thousand
112 confirms to IS
1979 working at 3-phase 400 440 volt, 50 C/S A.C 1.00 No 35080.33 Eighty and Paise
Supply and 2900 R.P.M for 6" Dia.Bore well. (2 ) 240 mt 170Head, & 17.5 Thirty Three
PVC insulated flat submersible cable as per detailed technical specifications Rupees Eighty
ofR/C of GWSSB conforming to IS 694, IEC 60227 / 60228.(C) IR x3 CX4.O Seven and Paise
mm2 Eighty Seven
Providing and supplying in standard length ISI mark high density
polythylene H.D.P.E pipes suitable for potable water as per ISI specification Rupees Two
No. 4984/1995 including all local and central taxes, transportation, freight
charges, octroi, inspection charges, loading unloading, conveynce to the 240.00 Rmt 263.61
Three and Paise
departmental stores etc.complete. (a) 10 kg / cm2 (90mm PIPE) Sixty One Only
Providing and supplying control panel Board for sub. Pump detailed Rupees Nine
specification as per GWSSB RIC S.D.Form 8 to IO H.P Thousand Two
Demolition including stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift. (i) R.C.C. work Rupees One
Thousand Eighty
Thirty Four Only
Dismentling steel work including distempering and stacking the materials
with all lead and lift.
117 13898.00 Kgs 3.84 and Paise Eighty
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF OUANTITIES
Item Description Quantities Unit In Figure Amount
Demolition of Brick work and stone masonry including stacking of
serviceable materilas and disposal of unserviceable materials with all lead
118 and lift.(ii) In Cement Mortar. 92.90 Cum 562.89
Eighty Nine Only
Dismentaling tiled of stone floors laid in mortar including stacking of Rupees Forty
119 serviceable materilas and disposal of unserviceable materials with all lead 1566.00 Sqm 49.11 Nine and Paise
and lift. Eleven Onl
Dismentling doors, windows, ventilators etc. (wood or steel) shutters
including chowkhats architraves, holdfasts and other attachment etc.
120 Hundred Ninety
complete and stacking them within all lead and lift(i) Not exceeding 3 Sq.M. 43.00 No 192.09
Dismantling sanitary fittings like wash basin, W.C. pan Indian and European Rupees Four
type, flushing tank etc. including stacking the materials with all lead and lift. Hundred
121 10.00 No 414.23 Fourteen and
Painting lines, dashes, arrows, letters, etc. on roads, air fields and like in two
coats with road marking paint Brushing including cleaning the surface of all
dirt, dust and other foreign matter. (1) Over 10 c.m. in width
122 259.60 Sqm 129.29 Nine and Paise
Lawn Grass:- Filling the area upto the depth of 23 cm. with good quality of
field fertile soil, breaking the clods leveling the area, free from stone, grass
roots etc. and farm yard manure at the rate of cu.mt. per 100 sq.mt. mixing
123 the Hundred Twenty
same with layer of soil, leveling rolling, pre-planting, watering etc and 1179.00 Sqm
and Paise Eighty
planting the lawn grass of approved variety at 10 x 10 cm. distance etc
complete as per details specification and maintenance for 3 months,
Plantation of trees in soil incl digging 45 x 45 x 45cm size pits, preparing
soil, providing and mixing organic fertilizers, watering planting and filling
124 150.00 65.65 Five and Paise
the pits as per direction including etc complete.
Sixty Five Only
Providing Tree Plants having minimum 1.00 mt 15.00 Height and healthy
growth of various kinds as like Peltophorum, Gulmohar, Karanj, Ambala Rupees Ninety
125 ,Rain tree Saptaparni, Cherry, Cryjeliya Spethodiya, Paras Pipala, Garmalo,
150.00 No 90.90 and Paise Ninety
Neem Borsalli, Kadam Buch, Champo.
Maintanance of Planted tree upto Two Year incl 275 times Watering, at
regular interval digging pits trimmimg applying Fertilizer insecticides .
pesticides and Pesticides and replacing plants if necessary etc complete for Hundred Sixty
raising of Plants weeding or soil working also. and Paise Fifty
Providing and fixing TREE GUARD 2.00 mt. long & of 600mm dia square
mesh of 50 X 50 mm and M.S. Flat of 25mm x 5 mm vertical support and
three rings of 20 x 3 mm flat, fixing on site in M 150 etc complete as directed
127 150.00 No 2494.70 Hundred Ninety
by Engineer in charge.
Providing and Laying of flag mast pole having G.I C- Class heavy duty
mm dia pipe of 4.5 Mtr, 75 mm dia pipe of 4.5 Mtr, including of 25 mm dia
pully with silver anti corrosive paint, Fixing of pole, Excavation, C.C work,
128 Hundred Thirty
grinding, Polished, finishing and Painting etc complete. 8.40 Rmt 1434.73
Providing, Supplying and Fixing Handicap Parking Sign, 1 Pack Rupees Eight
Handicapped Parking With Picture of Wheelchair, 12" Heavy Duty Thousand Nine
129 Aluminum Metal, Honeycomb-like Surface, Engineer Grade Reflective, Rust 2.00 Each 8940.52 Hundred Forty
Free, Waterproof standard quality as directed by engineer in charge and Paise Fifty
includin all materials and labours etc com lete. Two Onl
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing, Supplying and Fixing VMS Careline 100 Kg Load Capacity Black
Foldable Manual Wheelchair Select Plus VWE-1065 standard quality as Rupees Seven
directed by engineer in charge including all materials and labours etc Thousand Seven
130 complete. 2.00 Each 7782.05 Hundred Eighty
Providing, Supplying and Fixing Handicap Foldable with Floor Support Rupees Three
Stainless Steel Grab Bar, For Toilet standard quality as directed by engineer Thousand Two
including all materials and labours etc complete. 2.00 Each 3252.20 Hundred Fifty
Providing, Supplying and Fixing Disabled toilet symbol specifications
include using the universally recognized wheelchair symbol on a White-on-
blue background, with a minimum height of 1.5 meters above the floor. For
tactile and Braille signs, the minimum placement is 1.2 meters to 1.6 meters
132 Thousand Forty
above the floor, positioned on the latch side of the door. The sign should be 9.00 Each 1045.35
clear, visible, and have a contrasting color to the background standard
Thirty Five Only
quality as directed by engineer in charge including all materials and labours
Providing, Supplying and Fixing toilet symbol specifications include using
the universally recognized wheelchair symbol on a white-on-blue
background, with a minimum height of 1.5 meters above the floor. For
tactile and Braille signs, the minimum placement is 1.2 meters to 1.6 meters
above the floor, positioned on the latch side of the door. The sign should be 9.00 Each 813.05
clear, visible, and have a contrasting color to the background standard
Paise Five Only
quality as directed by engineer in charge including all materials and labours
Providing, Supplying and Fixing Braille marking specifications dictate the
precise physical dimensions and spacing of the six-dot braille cell to ensure
readability for blind individuals, with key measurements including a dot
height of about 0.48 mm (0.019 in) and a base diameter Of approximately
1.44 mm (0.057 in). Cell spacing is critical, with a distance of about 2.34 Rupees Four
(0.092 in) between dots in the same cell, and a larger distance of around
21.00 Sqm 4631.86 Hundred Thirty
mm (0.245 in) between corresponding dots
standards are vital for literacy and are set by authorities like the Braille
Eighty Six Only
Authority of North America (BANA) and the UK Association for Accessible
Formats (UKAAF). standard quality as directed by engineer in charge
including all materials and labours etc complete.
Providing, Supplying and Fixing non slip Flooing Pu Tactile Tile, Self
Adhesive Anti Skid, Floor Waterproof Direction Grey for Blind People
300x300 mm standard quality as directed by engineer in charge including
all 12.00 Sqm 6155.95 Hundred Fifty
materials and labours etc complete.
Ninety Five Only
Providing, Supplying and Fixing EMBOSED (size 300mmx300mm) as per
design including and necessary deep groove at joint and on suufaceas as per
desigu & directed bv architect laid on 12 mm thick with required chemical
Thousand Ninety
136 material jointed with grey cement slury including rubbing and finishing and 29.00 Sqm 2090.70
making cement finish vata (joint) groove etc complete.shade and patterm as
directed by Architect/Engineer in charge
Providing, Supplying and Fixing PVC Blind Board Warning Pad Plastic Blind
Floor Tile Sidewalk Guide Brick Podotactil PVC Tactile Paving Tiles Blind Rupees Four
Road standard quality as directed by engineer in charge including all Thousand Three
137 materials and labours etc complete. 130.00 Sqm 4381.38 Hundred Eighty
Thirty Eight Only
Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit In Figure Amount
Supplying and erecting testing, perfect aligning and proper leveling and
Rupees One Lakh
commissioning of Fire Service Main pump of at 83 m head centrifugal type 1.00 106050.00 Six Thousand
single stage pump, 17.5 HP or of suitable HP as per specification. (hydrant
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 Rupees Two
kg per cm square fitted with 12/15
mm dia. pad cock valve, and
elbow etc. complete as per specification Hundred Forty
Seven and Paise
Supplying and installing pressure switch with 12/15 mm
dia isolation valve,
G.I. nipple, elbow, etc Rupees Four
complete as per specification .
140 1.00 4999.50 Hundred Ninety
(7 Nine and Paise
Supply, Installation, testing & commissioning of class 'B' heavy duty M S
pipe conforming to IS including fittings like elbows, tees, flanges, tapers,
nuts bolts, gasket etc. fixing the pipe on the wall / ceiling with suitable
clamps and painting with two or more coats of synthetic enamel paint of
required shade including tapping with existing system complete as
re uired. Forh rants stem
100 mm dia Rupees One
.....1 200.00 Mtr 1969.50 Hundred Sixty
130.00 Mtr 1777.60 Hundred Seventy
Seven and Paise
70.00 Mtr 1638.32 Hundred Thirty
Eight and Paise
Thirty Two Only
20.00 Mtr 1424.10 Hundred Twenty
220.00 Mtr 1257.45 Hundred Fifty
Seven and Paise
Forty Five Only
Supply, Installation, testing & commissioning of Flaper non return valve
142 of following sizes confirming to IS 5312 complete with rubber gasket, GI
bolts, nuts washers etc as re uired.
1.00 Ea 8231.50 Hundred Thirty
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
.....2 1.00 7322.50 Hundred Twenty
Supply, Installation, testing & commissioning of butterfly valve of following
143 sizes confirming to IS 13095 PN 16 complete with rubber gasket, GI bolts,
nuts washers etc as re uired.
,....2 4.00 7191.20 Hundred Ninety
Supply, Installation, testing & commissioning of Foot valve of following
sizes confirming to IS complete with rubber gasket, GI bolts, nuts washers
etc as re uired.
100 mm dia Rupees Ten
.....2 1.00 Ea 8615.30 Hundred Fifteen
and Paise Thirty
Supplying and fixing Single headed external yard hydrant valve with 1 No
63 mm dia instantaneous SS metal coupling and cast iron wheel, ISI marked, Rupees Seven
confirming to with cap and chain
145 4.00 7282.10 Hundred Eighty
Supplying & fixing 63mm dia SS metal branch pipe with 20 mm (nominal
internal diameter) size SS, metal nozzle confirming to suitable for
instantaneous connection to interconnect hose pipe coupling as reqd. Thousand Three
146 5.00 2383.60 Hundred Eighty
Three and Paise
Supplying and fixing 63 mm dia, 30 mtr long RRL hose pipe with 63 mm dia
male and female SS metal couplings duly binded with GI wire rivets etc. Rupees Seven
147 conforming to IS as required. 5.00 7049.80
Supplying and hose cabinet
made of 2 mm thick MS sheet with 6 mm thick glazed glass doors with Rupees Three
necessary locking arrangement suitable to accommodate external hydrant, Thousand Six
nos 15 mtr long hose pipe. no branch pipe, mounted on wall or with
5.00 Ea 3686.50 Hundred Eighty
steel support & duly painted with
post office red externally and white Six and Paise
internally with synthetic enamel paint complete in all respect, for external Fifty Only
h drantas re d.
Supply, Installation, testing & commissioning of Four way fire service inlet Rupees Eight
connection of cast iron body with 4 nos. gun metal male instantaneous inlet Thousand Two
149 couplings complete with cap and chain as reqd. for 150 mm dia MS pipe 2.00 8201.20 Hundred One
connection, as required. and Paise
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit In Figure In Words Amount
Supplying and fixing First- Aid Hose Reel with M S construction spray
painted in post office red conforming upto date amendments complete
150 with the following as required. 20 mm (nominal) internal dia gun metal 5.00 Ea 7019.50
globe valve & nozzle.
Paise Fifty Only
Supplying, Installation, Testing and commissioning of brass quartzoid
sprinklers (UL listed) of 15 mm dia size, suitable for sustainingthe pressure
on the seat & water hammer effect The type & temperature rating
151 as follows :rating of 57 deg.C. with required accessories tools & tackeles to
Three and Paise
complete the job at satisfactory level of Client PM's.
Pendent Type Sprinkler 57 oc Standard response
Providing and fixing of fire alarm and pump trigger system as per
requirement and specification consisting of following items
ON OFF SWITCH -06
CORE COTING 1" Rupees One
153 40.00 Ea 1010.00 Thousand Ten
CORE CUTING 4" Rupees One
Supply, installation testing and comissiong of 25 mm dia automatic air
release valve with isolation valve, all acesories as required. Rupees TWO
155 2.00 Ea 2716.90 Hundred Sixteen
and Paise Ninety
Supplying, erecting & terminating XLPE armoured cable 3 core 70 sq. mm. Rupees One
copper conductor continuous mm. (12 SWG)
G.I. earth wire
complete Thousand Nine
156 erected with glands & lugs, on wall/trusses/ pole or laid in provided 70.00 Rmt 1908.90 Hundred Eight
trench/ pipe as per specification and Paise Ninety
Providing and Fixing FIRE EXTINGUISHER 4 KG ABC including cost of Rupees One
labour complete with providing 1 year guarantee for each bottle including Thousand Eight
testing and comissioning. Hundred
Providing and Fixing FIRE EXTINGUISHER 2.0 KG C02 including cost of
labour complete with providing 1 year guarantee for each bottle including
158 Thousand Three
testing and comissioning. 15.00 4343.00
Providing & Erecting Point wiring for Light/ Bell with 2-1.5
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to IO mtr length in below type of
pipe erected with 6A Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC / Metallic/ Wooden box,
159 single mounting base frame covered with textured/metallic/white front 430.00 pt. 485.81
plate modules erected on / in wall / ceiling as per pipe erected, with
Eighty One Only
necessary Lamp holder/ceiling rose H.D.Connector as directed.
medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. Ill
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit In Figure In Words Amount
Providing & Erecting Point wiring for FAN with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (Green) both are of .1Sl marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth continuity of
Hundred Seventy
160 following type erected on PVC / Metallic/Wooden box, single mounting 97.00 674.68
base frame covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose Sixty Eight Only
/ H.D.Connector as directed, (f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling complete Cat. III
Providing & Erecting Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on PVC / Metallic/ Wooden box,
161 single mounting base frame covered with textured metallic/white front
Seven and Paise
plate modules erected on / in wall / ceiling with following type accessories
Fifty Five Only
Providing & Erecting following type of Modular Type Accessories mounted
with PVC / metallic/ Wooden box, single mounting base frame covered with
162 textured / metallic/ white front plate modules erected with necessary
connections as per site situation directed by Engineer In charge. (7) Blank
Plate Sin le Catl[l
No. SP 6 Amp. Catlil Rupees One
..Do....(2) One No 5 pin plug Cat.lll Rupees One
...Do....(9) 16 Amp. SP one way switch Catili Rupees One
165 3.00 Nos. 180.79 and Paise
...Do....(IO) 6/16Amp. Universal socket Cat.lll
166 13.00 Nos. 199.98 Nine and Paise
...Do....(14) 16A/ ZOA/ 25A/ 32A Double Pole Modular MCB Switch Cat.lll Rupees Four
...Do...(8) Computer RJ-45 socket Cat.lll Rupees One
and Paise Fifty
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary
169 Three and Paise
PVC fittings & Junction boxes fixed with adhesive solution & Clamps with 855.00 Mtr. 33.33
following dia of pipes, in approved manner as directed (b) 25 mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in [flushed on wall/ceiling, With 1.5 sq. mm copper
170 3185.00 Mtr. 82.82 Two and Paise
conductor FRLS PVC insulated stranded wire of green colour for earth
Eighty Two Only
continuity of following size (A) With medium class Rigid PVC pipe and
accessories b 2 wire 2.5 s mm .
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
Providing and erecting Mains With 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be Rupees Two
erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC Hundred Sixty
insulated stranded wire of green colour for earth continuity of following and Paise Fifty
size (A) with medium class Rigid PVC pipe and accessories (h) 4 wire 6 sq. Eight Only
..Do...(b) 2 wire 6 sq. mm
172 Hundred Forty
Seven and Paise
...Do...(a) 2 wire 4 sq. mm
and Paise Eleven
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC 227 erected in existing pipe of following
174 size (Specifically for control panel, relays, power switchgears, motor
starters & control wiring) With required size of copper lugs, nuts and bolts
if Forty One Only
required. (g) One wire 16.00 sq. mm
...Do...(h) One wire 25.00 sq.
175 Hundred Thirty
Thirty Four Only
...Do...Cj) One wire 50.00 sq. mm
176 15.00 Hundred Seventy
470.66 and Paise Sixty
Providing and erecting Flexible PVC insulated multi strand multi core 1.1 kv Rupees Forty Six
177 grade ISI marked copper wires of following size to be erected as 110.00 Mtr. 46.46 and Paise Forty
directed. e 1.50 S .mm 3 core round PVC sheathed Six Onl
Supplying & erecting approved make LAN cable of following size in existing
pipe as per direction [D] CAT - 6 e Rupees Seventy
178 2123.00 Mtr. 76.76 Six and Paise
Seventy Six Only
Providing & erecting Switch board for Computer or electric apparatus
consisting of following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base frame covered with
179 Hundred Thirty
textured/ metallic [white front plate,modules erected with necessary 83.00 Nos. 1133.22
connections as directedl no. 6A/16A universal plug-switch combined. 3 Three and Paise
Switch 3 Twenty Two
For Modular Type Accessories Cat.
Providing & erecting Decorative call bell Ting-tong box type 250 volts
complete erected Rupees Seventy
180 One and Paise
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit
In Figure In Words Amount
Providing and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.95,
THD < 15%,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt
181 ,LED driver efficiency >
Hundred Seventy
fitting required LM-79 & LM-80 10.00 Nos. 373.70
Three and Paise
Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (A) Tube Light with integral driver
(iv) 22-24 Watts, Surge 2KV,lP-20, conventional 4 feet Cat-III
.DO ...O) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet Rupees One
Providing and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V.& corrosion resistance with
diffuser housed in aluminium casted body with company mark/name 160V
to 270V,Power Factor
Luminaire efficacy> 85 lumens/watt
183 LED driver efficiency > 85 (
fitting required LM-79 & LM-80
% 104.00 Nos. 427.23 Seven and Paise
Certificates)(NOTE: Below description have shown ranges of Mlattage Twenty Three
capacity of LED fittings.The Engineer incharge may select any wattage Only
capacity between the ranges shown.) (A) Square/ Circular shaped
Surface/ Recessed Mount Downlight with provision for spring loaded
mounting clips complete.IP20 (ii) 11-15 watts, Surge-2 KV Cat-III
..Do...(iv) 22-24 watts, Surge-2 KV Cat-III Rupees Seven
Eight and Paise
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of Watt and above assembled on single
MCPCB, efficiency more than 130 1m/ w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and heatsink
extruded aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or embossed 160 to
270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 Kto Rupees Three
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt. LED
185 19.00 Nos. 3345.12 Hundred Forty
driver efficiency > 85 fittings required LM-79 & LM-80
certificates) (NOTE: Below description have shown Five and Paise
ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage Twelve Only
capacity between the ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC line supply with over
voltage protection. (i) above 36 to 48 watts Cat-III
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal Rupees Six
current rating up to 25 A to IOOA. With Fixed thermal & magnetic release
186 4.00 Nos. 6173.12 Hundred Seventy
suitable to work on AC. supply 50 c/s. with all internal connections,
Three and Paise
spreader tinned copper & complete erected in existing 16 G.M.S. housing.
oflCU onl Cat Ill
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having normal Rupees Eight
current rating 125A. with Fixed thermal & magnetic release suitable to Thousand Fifty
work on A.C.suppIy 50 c/s, with all
internal connections, spreader tinned Five and Paise
copper & complete erected in existing 16 G.M.S. housing. of ICU Seventy Six Only
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. and above at 415 V having.
normal current rating 250A. with variable thermal & magnetic release
188 suitable to work on A.C.supply 50 c/s. with all internal connections, 1.00 Nos. 23041.03
spreader tinned copper & complete erected in existing 16 G.M.S. housing.
of ICU only Cat Ill (With Enclosure Rs. 20739 + Rs. 2073.90= Rs.
Paise Three Only
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal Rupees Sixteen
current rating 200A.with variable Thermal & magnetic release suitable to
3.00 Nos. 16221.61 Hundred Twenty
work on A.C.suppIy 50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.housing of ICU
Providing and erecting following additional parts for panel mounting
MCCBs (A)Extended operating rotary handle with pad lock with three
190 position trip,off,on suitable for 25A to 250 A panel mounting cat-III 13.00 Nos.
Hundred Seventy
Three and Paise
Sixty Five Only
Supplying & erecting approved make Four Pole 415V change over switch
interior for panel mounting with operating mechanism A.C.23 duty Rupees Thirteen
confirming to IS for (E)250A / 320A Cat-III Thousand Four
191 1.00 Nos. 13454.21 Hundred Fifty
Twenty One Only
Supplying and erecting triple pole & neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos. of electrolyte bus having current Rupees Three
density not more than 1.6 Amp. / sq.mm (Rated current / cross section Thousand Two
area) duly wrapped with colour insulating tape for phase sequence of Hundred Two
following current carrying capacity, erected with necessary bus bar and Paise
supports [insulators, main cable socket to each bar, erected in existing Seventy One
cubical panel with necessary connections. (B) Suitable for 200 Amp. Only
..Do...(C) Suitable for 300 Amp. capacity Rupees Four
193 1.00 Rn Mtr 4909.61 Hundred Nine
and Paise Sixty
providing and erecting Miniature circuit breaker single pole 0.5A to 2A
system and having breaking capacity 10 KA to be erected in existing box.
194 confirming to IS 8828/1996 with ISI Mark Cat-III 19.00 Nos.
Hundred Seventy
and Paise Sixty
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity 10 Rupees One
195 KA to be erected in existing box. confirming to IS 8828/1996 with [Sl Mark Nos. Hundred Twelve
and Paise Eleven
Providing & erecting 240 V MCB double pole switch for motor & inductive Rupees Three
load (C Curve) having IO KA breaking capacity & confirms to IS : 8828 in Hundred Thirty
196 existing box having following capacity (B) 40 Amp. Cat-III 44.00 Nos. 330.27 and Paise
...Do... (A) 6 to 32 Amp. Cat.lll
197 3.00 Nos. 299.97 Nine and Paise
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing
198 box having following capacity (c)63 Amp. Cat.lll 26.00 Nos.
Seven and Paise
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
...Do... (b)40 Cat.lll
Amp. Rupees Six
Eight and Paise
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Thousand Four
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
200 appropriate nos. of MCBs.(The DBs should be used of same company of 10.00 Nos. 3412.79
MCB to be used) suitable for (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type (PPI) (b) sheet steel
double door iii 8 wa
..Do...(A) single phase incoming and horizontal single phase outgoing (b) Rupees Eight
sheet steel double door (IP-43) (ii)6 way Hundred Eighty
201 5.00 Nos. 885.77 Five and Paise
Providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of IO KA Rupees Two
and suitable for operation on single phase 240 V,50Hz, having characteristic Thousand Two
202 of quick action & tripping with all advance feature & do not incorporate
any 35.00 Nos. 2235.13 Hundred Thirty
electronic component. for following Max. rating erected as directed (ii) Five and Paise
40Amps.DP Cat, Ill Thirteen Only
Providing and erecting Annealed bare Copper wire 8 to 16 SWG.
203 10.00 Kg. 794.87 Four and Paise
Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. Rupees Three
dia. galvanised iron pipe with coupling and buch buried in specially Hundred Sixty
prepared earth pit complete with necessary 8 SWG earth wire. Eight and Paise
For using salt and charcoal / coke as required for pipe type earthing.
Hundred Seventy
Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B'
grade G.I. pipe With necessary coupling buch buried in specially prepared Rupees Eight
206 earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For Nos. Hundred Twenty
Three and Paise
Providing and erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe Technology as
3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising, connection terminal dia of 12mrn
with constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of applications with Rupees Four
chamber and heavy duty cover.(approved make OEM has to submit test Thousand Five
207 certificate) & having back filling compound of (B) Inner chemical (CCM 4.00 Nos. 4591.46 Hundred Ninety
Compound)- Resistivity:- 0.2 D/' meter testing as per IEC 62561-2017, One and Paise
Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Forty Six Only
Back fill Compound Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted. (a) For
Electrical Installation to 440V in normal soil
Length of pipe 1 Mtr Back filling compound 1 Nos Bag of 15 Kg.
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
Providing & erecting weather proof, dust 82 vermin proof, floor mounted
front operatec indoor type cubical panel board necessary IP-42 and above
protection as per approval from engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheetfor
internal partitions with necessary accesories supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-
charge with erection of supplied switch gears, BUSBARS, suitable size of
inter connecting PVC /
copper wire copper-aluminium strips, rubber
grommets, rib bakelite control fuses/MCB for measuring instruments, Rupees Fourteen
earth bus & earth bolts, foundation flange bolts-base Plates, sufficient nos.
208 of hinged doors, handles with locking
arrangement and rubber 4.80 Sq Mtr 14902.55 Hundred Two
gasket,heavy duty end terminal connection,danger notice board,necessary and Paise Fifty
ventilation,earthing strip complete. The Panel shall be painted with epoxy Five Only
powder coating. (The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding base beams) The panel shall be
supplied with following approved manufacturers with following size. (B)
The standard companies switch gear shall be used and only manufacturers
at CPRI approved factory (i) with
Providing erecting fabricating the M.S. structure as per requirement on
site incorporating
proper size of M.S. angles,square,round,
channels, sections complete with cutting, welding, grinding & finishing duly
Seven and Paise
209 painted with one coat of red oxide with erection on site as per direction of 110.00 Kg. 77.77
engineer in charge with necessary grouting, cementing, plastering &
finishing complete.
Providing and erecting ISI
armoured cable multistrand Rupees One
Aluminium conductor for. 1.1 KV. to be laid on wall with necessary clamps Hundred Seven
or in existing trench / pipe of following size of cables. (C) 3 core 6 Sq. mm and Paise Six
Providing and erecting XLPE(lS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps Rupees Two
or in existing trench pipe of following size of cables (C) 3 1/2 core 50 Sq. Hundred Eighty
mm 25 Sq.1/2 mm core)
Eighty Two Only
...Do....(F) 3 1/2 core 120 Sq,mm (70 sq. mm 1/2 core)
212 Hundred Forty
and Paise Thirty
Providing and erecting XLPE (IS: ISI
armoured cable Rupees One
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on wall Hundred Twenty
213 with necessary clamps or in existing trench / pipe of following size of 580.00 M tr. 126.25 Six and Paise
cables. (B) 4 core 6 Sq. mm Twenty Five
Providing and erecting XLPE (IS: ISI
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with Rupees One
214 Hundred Fifty
necessary clamps or in existing trench pipe of following size of cables (A)
4 core 16 Sq. mm
Three and Paise
Making trench in soft soil of suitable width of 90 cm deep for laying cable or Rupees Fifty Five
215 locating the fault all over the run and back filling the same and making the 650.00 Mtr. 55.55 and Paise Fifty
surface as normal round. Five Onl
Providing & laying approved make ISI marked HDPE 6Kg / cm2 (Class-3) Rupees One
as per IS:4984:1995 PE-80 to be erected at road crossing on or floor as Hundred Eight
directed for laying of cable. The pipes as following size of dia & weight per 6 and Paise Seven
mtr. A 40 mm inner Dia. onl
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities
In Figure In Words Amount
...Do....(C) 63 mm inner Dia.
Forty Seven Only
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
218 24.00 Nos. 38.38 Eight and Paise
insulating tape etc for following size of cables.
Thirty Eight Only
2t04core6S mm .
...Do....(D) 2 to 4 core 16 Sq. mm
219 8.00 Nos. 47.47 Seven and Paise
Forty Seven Only
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete
220 with out going tails, insulating tape etc for following size of cables. (B) 3 & 3.00 Nos. 75.75
1/2 core 35/50Sq. mm
& 1/2 core 120 Sq. mm
and Paise Thirty
Solder less crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected Rupees Six and
to switchgear terminals with brass/ cadmium plated nut bolts in an Paise Six Only
a roved manner. 1.5A 2.5 4 6 S
...Do...(C) 16/25 Sq.mm. Rupees Fifteen
223 35.00 Nos. 15.15 and Paise Fifteen
224 15.00 Nos. 20.20 and Paise
...Do...(G) 120 Sq.mm. Rupees Forty
226 18.00 Nos. 45.45 Five and Paise
Providing and erecting Approved make Ceiling fan with double ball bearing
mark with condenser A.C. 230V.50 c/s.1200 mm. sweep complete,
227 canopy erected on existing hook or clamp with earthing. 97.00 Nos. 1596.81 Hundred Ninety
Eighty One Only
Providing and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe Rupees One
down rod erected duly painted for fan complete with proper insulation Hundred Eight
without leakage and earthing. and Paise Seven
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to Rupees One
the RCC bars up to 50mm length each side and pierced through a 16 Gauge Hundred Eight
M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with and Paise Seven
Providing and erecting approved make low noise decorative exhaust fan
having square frame ABS body with inbuilt lowers & square frame. 250mm Rupees One
with 1350 RPM Catil Thousand Three
230 27.00 Nos. 1366.53 Hundred Sixty
Fifty Three Only
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Quantities Unit
Item Description In Figure In Words Amount
Supplying and erecting approved make Octagonal pole made from HR sheet
steel. The pole should be made as per IS. and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min 6mm Hylam
sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be erected With
231 19.00 Nos. 5556.01 Hundred Fifty
Suitable foundation (Included) as per details given by manufacturer Six and One
considering site requirement. (B) 4 Mtr. Long 70 mm Top X 130 mm
bottom dia, 3 mm thickness with 200mmX200mmX12mm base plate, 4-
M16 Bolts and 450mm long with necessary G.I. J Bolts .Approx weight 37 kg
Providing cement concrete.for foundation or for concrete filling in 1:2:4
ratio With 20 to
mm stone metal duly plastered with necessary curing Thousand One
for pole muffing or
any other purpose.
Seven and Paise
Supplying and erecting Street light pole bracket comprising main B Class GI
pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I.
sleeve tubing of approx. 45cms.length and suitable for Rupees Four
76.5mm/80mm/require size of pole top having nuts and bolts for fixing the Hundred Ninety
233 brackets and having spread of 0.5 mtr. Length with 110 deg.with vertical 19.00 Nos. 491.87 One and Paise
plane and suitable welded stiffener reducer and nipple with check nut Eighty Seven
complete painted with one coat.of Red oxide / PU base primer and two Only
coats of Aluminium / PU paint. paint with following nos of arms. [A] Single
Arm bracket 0.5 Mtr
Supplying & erecting approved make IP 55 grade Company fabricated
Timer Panel of following capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet duly epoxy power painted
inside and outside with hinged doors and locking arrangement consisting of
Nos. Hundred Ninety
234 suitable size of 4 Pole MCB and 4 pole contactor (cat-Ill)with analog time 1.00 12399.77
switch, auto manual switch of same make and suitable input and output
Bakelite terminals and with door earthing approved by Engineer in charge.
Providing Erecting Testing 4K Sony Bravia/ Samsung/ LG or Equivalent led
TV 189cm (75 Inch) Ultra HD (4K) LED TV smart Google TV smart TV/Full
HD Pur colorK or equivalent and above Display 4K Ultra HD LED. 3840 x Rupees One Lakh
2160 pixels, 60Hz refresh rate connectivity 3 HDMI 2 USB I Wi-Fi
Operating System: Web os- linu base, / Tizen operating system/android
235 1.00 Nos. 170636.27 Hundred Thirty
operating system google TV, Apple TV plus, Netflix, Prime Video,
Disney+Hotstar-/ google. Sound : 20W Speaker, with Remote, 4K Upscaling-
{Approved by competent Authority i.e. not Below the rank of Executivr
Providing, Erecting and testing of SONY Bravia /SAMSUNG/LG or
equivalent led TV 108 cm (43 inch) 4K and above Display: 4K Ultra HD LED,
3840 x 2160 pixels,
60 Hz Refresh Rate Connectivity: 3 HDMI 2 USB Wi-Fi Operating System
Rupees Fifty One
| Thousand Eight
WebOS-linus base, Tizen operating system/android operating system-
1.00 Nos. 51828.15 Hundred Twenty
Netflix, Prime Video. Disney + Hotstar-/ google Sound: 20 W Speaker, with
Eight and Paise
Remote, 4K Upscaling- [Approved by Competent Authority i.e. not Below
the rank of Executive
Supply, Installation Testing & Commissioning 5 Mtr. HDMI Interface Cable
as per the detailed Specifications supports transmission of 4K Signals as per
237 the detailed Specifications 1.00 Nos. 828.20
Eight and Paise
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit In Figure In Words Amount
Supply, Installation Testing & Commissioning 15 Mtr. HDMI Interface Cable
as per the detailed Specifications supports transmission of 4K Signals as per Rupees One
the detailed Specifications
238 2.00 Nos. 1777.60 Hundred Seventy
Seven and Paise
Providing and erecting Inverter based approved make split air-conditioning
unit consisting of condensing unit with variable speed fan motor, inverter
type hermetically sealed rotary compressor with accessories etc. duly
connected separately erected evaporating unit and blower motor with its Rupees Fifty One
accessories by means of extra supplied proper insulated copper
239 4.00 Nos. 51666.55 Hundred Sixty
tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas
charging and 15A plug top & Remote Control & MS Stand) with necessary
Fifty Five Only
core cutting. (1)For (SEER Range to 3.99) (C) for 1.7 to
Supplying and erecting insulated pair of soft copper tubing open or Rupees Nine
concealed including power and control cable,necessary PVC drain pipes for Hundred Sixty
SplitAC machine up to 4 TR capacity Five and Paise
Providing & erecting water cooler having storage capacity 150 Ltr. &
cooling capacity 150 Ltr.per hour @ an ambient temp of 45' C. The outlet
temp. of the water should drop by 150C within a hour, The water cooler Rupees Fifty Five
should be comprising of hermetically sealed compressor, fan motor,
241 3.00 Nos. 55893.40 Hundred Ninety
condensing unit, water tank surrounded by evaporating, coil, thermostats,
relay etc.complete with necessary inlet & outlet connection. The body of Three and Paise
water cooler will be made from Stainless Steel. Forty Only
Supplying & erecting 5 stage single reverse osmosis water purification
system with M.S. powder coated frame, prefilter housing with 'O' ring Rupees Twenty
presediment filter GAC filter, carbon filter suitable buster DC pump capacity Nine Thousand
80 psi, mention with 40 psi inline type post carbon filter
auto low & high
242 One Hundred
pressure switches with following size of storage tank & LPH capacity & Eighty Seven and
erected as directed [C] 50 lotr / Hr with 150 psi 2 nos booster pump Paise Ninety
Providing & erecting open well horizontal mono block
pump set with cast
iron body, complete for three phase submersible motor having [D] For 5 Rupees Eighteen
HP 3 phase open well horizontal mono block pump set suitable for 1350 Thousand Seven
243 LPM to 310 LPM @ IO to 42 Mtr head suitable for 50/65 mm dia delivery 2.00 Nos. 18746.61 Hundred Forty
pipe Cat. II Six and Paise
Supplying & erecting approved make motor control cubical panel (Direct-
on line) made from 16 G. CRCA sheet duly epoxy powder painted inside
and outside with hinged doors and locking, arrangement consisting of
suitable size of ON- OFF isolator (AC 3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y B phases, overload relay, Automatic
water level controller, Ammeter, Voltmeter each with two way selector Thousand Seven
244 2.00 Nos. 7722.46 Hundred Twenty
switch incoming, wires duly socket crimped, main contactor & overload
relay, start-stop push buttons, to be erected on angle iron frame grouted Two and Paise
on wall as directed. The isolator, overload relay & contactors will be of L &
Siemens or BCH make only. (A) DOL up to 5.0 H.P.
Lowering of submersible motor pump set at the depth of following
,complete with required. Nos. and size of casing pipes erected by means of Rupees Eight
245 proper chain pulley block & pipe wrenches after checking of threads of each Hundred Fifty
pipe with coupling to take the load of the pump set and pipe assembly filled 2.00 Per Job 856.48
up with water (D)For Open well Horizontal submersible pump set for Forty Eight Only
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF OUANT!TIES
Item Description Quantities Unit In Figure Amount
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Rupees One
Submersible copper cable approved make of following Size. (C) 3 Core x 4 Hundred Forty
Sq. Six and Paise
Providing Water proof straight Joint in PVC insulated flat flexible copper
cable by using insulating material, water proofing material, & making the Rupees One
joint complete. (A) Up to IOSq. Hundred Eighty
Eighty Eight Only
Supplying & erecting ISI Marked (Embossed) following size of "B" Class G.I .
Pipe & erecting as directed by Engineer-in-charge with necessary plumbing Hundred Sixty
as desired. (C) 50 mm dia Two and Paise
Supplying & erecting Mild Steel heavy duty Flanges with rubber packing Rupees One
and hardware materials for pipe connections suitable for (A) 50 mm (2") Hundred Thirty
249 2.00 Nos. 130.29 and Paise
Supplying and erecting ISI marked sluice valve at position with necessary
material for following size of pipe diameter. (D) 50 mm(2")
803.96 and Paise Ninety
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI Rupees One
marked suitable for following size (A) 50 mm dia. Thousand
Supplying and erecting approved make panel mounting type Digital
Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on Rupees One
existing panel board with all connection, wiring etc .with manufacturers
252 4.00 Nos. 1275.63 Hundred Seventy
calibration certificate.
Sixty Three Only
Supplying and erecting approved make panel mounting type Digital
Ammeter having 3 digits LED display, external CT operated, calibrated for
0 to 1000 Amps suitable to operate on 500 Volt AC erected on existing
4.00 Nos. 1558.43 Hundred Fifty
panel board with all connection, wiring etc .with manufacturers calibration
Eight and Paise
Forty Three Only
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase Rupees Three
AC Supply 500 V on existing panel board with necessary connections. Hundred
254 8.00 Nos. 317.14 Seventeen and
Providing & erecting L.T. Current Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with
insulating materials connected to the meter
Hundred Seventy
255 12.00 Nos. 274.72 Four and Paise
Supplying and erecting approved make suitable panel indicator LED type
lamp, lens cover, complete erected with necessary connections.
256 12.00 Nos. 43.43 Three and Paise
Forty Three Only
Supply and installation call button (transmitter) with pull string (1 m).
Single button for both call and cancel. Cancellation by long press of button.
String length can vary depending on the requirement, call or cancel button
3.00 Nos. 3190.59 Hundred Ninety
sticker can be placed on the base unit. long battery life, water proof. As per
and Paise Fifty
Name of Work . Construction of New Mamlatdar office building at Sojitra, Dist: Anand
Item Description Quantities Unit Amount
No. In Figure In Words
Supply and installation of mounting cover for fixing SB5 series call points
on the wall. Call points to be purchased seperately. Image with call point is
258 for representation only.
and Paise Thirty
Supply and installation of wall mounting type corridor lamp (Receiver) 6-
lighting colours available (colour selectable) steady or blinking, beep sound Rupees Eight
on works on 12 V DC adaptor. auto cancel after 60 seconds Thousand Three
259 (configurable) can be configured With multiple call points. over for fixing 3.00 Nos, 8340.58 Hundred Forty
SB5 series call points on the wall. Call points to be purchased seperately. and Paise Fifty
Image with call point is for representation only. Eight Only
Supply and installation of power adaptor for main display/repeater/PC
monitoring receiver.
260 Nos. Hundred Twelve
and Paise Eleven
SITC of Three Phase IN & Three Phase Output Unbalaced Type 80kva Oil
Cooled Indoor type Servo Voltage Stabilizer, Following Below Technical
I-Input Voltage Regulation 380vto 480v 2- Output Voltage 415+/-1% Line Rupees Two
to line with Oil 3-lnput High voltage & Input Low Voltage Cut off 4- Output Lakhs Five
261 Over Voltage & Under Voltage Cutoff and Trip 5-Single Phasing Preventer & 1.00 Nos 205535.00 Thousand Five
Phase Loss trip Hundred Thirty
6-MicrocontroIIer & DSP based Electronics card with inbuilt LCD Displayed Five Only
7-Load Current phase wise monitoring.With Oil 8- Input MCCB 160A FP
Supplying and erecting, commissioning and testing of Diesel Generating set
confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase,
415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/ water
cooled diesel engine with multi-cylinders developing suitable BHP not less
than following capacity at 1500 RPM with overload for one hour in
hours with standard accessories like fly wheel, lubricating Oil cooler, "A"
governor, heavy duty fuel wheel and lubricating oil filter, oil bath air
filler, lubricating oil pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder head to cover, joint
cylinder head to exhaust, element lube oil filter, 12 / 24 volts electric
starting equipment complete with standard heavy duty battery, dynamo,
cut-outs, ammeter,
necessary wiring, pressure gauge, starter etc and heavy
duty Residential type exhaust silencer (With DEF System) and vertical hot
logged with asbestos rope, save oil trays, exhaust piping of required length,
standard wall/floor mounted fuel with level indicator and piping and drip
proof alternator, self excited, self regulated, scceen protected, with
excitation system, capable of delivering the rated system output at
volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-
4722- 1968 with voltage regulation +/- 5% of rated voltage from no load
to full load. Both the engine and alternator fitted on a
common fabricated
steel base plate with antivibration mounting engine and alternator both
connected to each other by flexible flange coupling and with floor/ wall
mounted control panel box comprising of voltmeter ammeter, selector
switches, ACB / MCCB / MCB of adequate capacity,
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
FILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
indicator lamps duly wired with HRC fuses. The alternator & control panel
shall be connected with provided suitable capacity armoured cable and
complete with Acoustic enclosure (canopy) made out of 16 SWG CRCA
Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick
conforming to IS:8183 / PU Foam of 40 Density at least 40 mm. The resin
bonded rockwool covered from inside the canopy by perforated sheet with
3/4 mm holes, sound level not more than 75 dB ata distance ofl mtr, as
per PVCT norms.DG set should have
in built fuel tank
capacity of minimum
8 hrs of continous running capacity on full load Erection, commissioning
and satisfactory testing as per requirement with first filling of fuel
(minimum up to the of fuel tank capacity), oil, etc. with guarantee /
Warrantee of complete system for Two years. & with obtaining all
necessary certificate from Electrical Inspector. The Capacity and Ratings Of
DG sets are as below. (As per new CPCB4+ Emission norms Engine With -
Turbo Charger, EGR (Exhaust Gas Recirculation), CRS (Common Rail Fuel
System), DOC (Diesel Oxidation Catalyst), SCR (Selective Catalytic
Reduction), Integrated wiring harness connected to ECU
(M) Continuous rating of 125 KVA ,BHP not less than 154 BHP
Ninety Four and
Paise Four Only
Providing & erecting approved make ATS panel suitable for following size
of 3 phase, 415 V., 50 cycles, A.C. diesel generating set
complete of scope as
detailed below:
1) Two Thousand
Power module: Motorised Changeover switch with ATS controller,
263 Auxiliary contactor with NO & NC contacts with Automatic Battery Charger, 1.00 Nos. 72755.35
indicating lamps for Generator ON, Mains ON, Load and suitable control
Paise Thirty Five
terminals and power terminals with neutral earthing studs.(E) ATS Panel
for 100/ 125 KVA 3 phase DG Set Only
Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift
havin followin main features:
A GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting
phase 440 V A. C. Permanent Magnet Synchronous motor of proper rating
with hi h efficienc shall be used
[2] Micro processor based / PLC, ACVVVF, vector control drive with
encoder feedback closed loop system shall be used for lift car and door
operation which shall be full collective selective operation hall call demand
response, UP/ DOWN
stops, Main, Up/ Down Contactor with overload
and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and to sustain the
impact load cabin + passenger with safety factor of fire for steel and side
panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S.
finishes with aesthetic appearance with LED ceiling lights. Car flooring shall
be of s/s 304 chaker plate design sugeested of engineer in charge. of
engineer in charge. Car doors shall be of stainless steel grade 304, hairline
finish with centre opening / telescopic automatic doors. Car panel Will also
be S.S. 304 finished with
emergency stop device, mechanical door
device, facility of auto/ attended mode. All car panel buttons and all floor
switches must be with brail language as per lift act
[4] All landing doors must be fire rated for 2 hour shall be fully automatic
centre opening/ telescopic opening made of hairline finish steel grade of
304 with key holes and infrared curtains with Unlocking facility from
Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL OF QUANTITIES
Item Description Quantities Unit Amount
No. In Figure In Words
[5] Appropriate battery operated light in the car along with
alarm switch shall be provided. Also, Emergency Light & Fan should start
immediately without any Time Delay as soon as power fails.
[6] Digital scrolling indicator
system for up-down arrow along with floor
position indicator shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light beams
shall be rovided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of
passenger capacity with Manual Rescue Operation Manual Cranking
[9] Audio visual indication in the lift car showing over loading shall be
rovided such that doors ke to en till excess load is removed.
10 S rin buffers PU Buffers shall be rovided.
[11] Car fan as per passenger capacity with automatic sleep timer shall be
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be
rovided in control anel.
[14] Mechanical over speed governor with governor calibration as per
actual site parameters and submission of calibration certificate submission,
door key holes in the floor doors, fireman switch shall be provided,
[15] Lift machine hoisting arrangement in the lift machine room and
monkey ladder for lift pit should be provided by the lift agency, along with
the other steel structure works, foundations for the machine etc...
[16] In the hoist way fascia plate shall be provided without any extra cost,
where ever required as / if directed by engineer in charge.
[17] Permanent wiring with necessary safety devices like RCCB in all
circuit, Over Voltage Under Voltage protection and THD eliminator in circuit
for lift machine
well with proper numbers of light points, with
fixtures, exhaust fan and plug points shall be provided by the
phase Power Supply shall be made available by department in lift machine
room, Necessary Earthing as per LiftAct/Rules shall be arranged by Lift
[18] Any civil/ electrical works for additional and alteration in lift shaft and
machine room related to erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around
landing door openings are
not in lifta enc 's sco e.
[19] Agency has to provide all working drawings and documents and liaison
services for obtaining all necessary permission from lift inspector and other
20 acr lic trans arent licence dis la A4 size holder in lift car
[ZOA] As per statutory requirement of Govt. Of Gujarat lift & escalator act
2000, lifta enc has to rovide
1. Car to safe barricade
& talk communications stem.
3. Fireman's switch o
eration at Ground Floor.
4.carrying out third party lift inspection during/after lift erection and
provide report by third party authorized by concern licensing authority
5.agency has to provide third party insurance upto completion of free
maintenance eriod and submit the document for the same.
[21] Car Panel Operating Buttons with floor position indicator/buttons
must be of Auto Glow type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline
finish steel grade of 304 should be provided at appropriate height on the
Rear & Side Wall Panels in Lift Car.
Name of Work :- Construction of New Mamlatdar office building at Sojitra, Dist: Anand
BILL QF QUANTITIES
Item Description Quantities
In Figure In Words Amount
[23] With Necessary KVA rating voltage controlled Stabilizer suitable for
our controller, drive and ments of lift.
[24] Necessary rating of DP ELCB/RCCB and FP ELCB/RCCB required for
lift is in scope of work which rating is sugested by CEICED Department
Electrical Ins ector
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM category
control system dual 64 bit embedded microprocessor with
CANBUS Serial Communication mode including Regenerative power
efficient operation,on site programming facility, Anti nuisance, Pte-opening,
BMS/RMS with necessary online real time monitoring system having
necessary connectivity for remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose.
Floor Indication LCD Display with call registration & brail mark with
gong and hall lantern & TFT Screen
arrival in the car with MP3 Voice
CAR Panel should be Scratch resistive SS Moonrock finish Hair Line
Honeycomb for car and all Doors, All landing doors must have fire rating
up to hours and car door must have multi-level crisscross beam door
To & fro communication system & wiring (i.e. car control room & guard
room and Each elevator are equipped with remote monitoring
system.agency has to provide mobile app and
user password for
13 Passengers,. Ground plus 2 of
upper floors with Rated Speed
(C) With General PLUS ADDITIONAL SPECIAL FEATURES attached
herewith. Prem. Cat.
Seventeen Lakhs
1.00 Nos 1701663.15 Six Hundred
Sixty Three and
Rupees Six Crores Forty Nine Lakhs Seventy One Thousand Three Hundred Fourteen and Paise Forty Only
Total Tendered Amount
Rebate on Tendered Amount (if any) % (in Figures) Rs.
(In words Only).
Net Tendered Amount (A - B)
(Rs. in Words Only).
(* Please strike out whichever is not applicable).
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-ln-Charge for which
no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
GST and Income tax TDS will be deducted at a source while making payments of bills.
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as
per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as sta ted in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design
the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned
in all the tender.
5. Credit of dismantled materials of amount of Rs. 155803.93 must be recovered from Contractor's first R.A Bill.
Dated Signature of Deputy Executive Engineer Executive Engineer
the Contractor. Road & Building Sub Division Road & Building Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_Checklist.pdf
02_Standard Bidding Documents.pdf
03_Specification Index.pdf
04_Details Specifications.pdf
05_Schedule Testing-General Specifications.pdf
06_Bill Of Quantities.pdf
07_Government Resolutions.pdf
General Specifications of Building Works-P1_compressed.pdf
General Specifications of Building Works-P2_compressed.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .