Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LRejected-Finance | L1 | Rejected-Finance Quoted amount of the single tenderer is above the max permissible limit. Contractor has not submitted his willingness to reduce the amount to the allowable limit. |
Tender Value
₹29.8 L
EMD Value
₹50,000
Closing Date
17 Sept 2018, 5:00 pmClosed
Superintending Engineer
Minor Irrigation Central Circle, B2 Block, Civil Station, Kakkanad, Ernakulam
Construction of Pump house including electrical works
2018_Irrig_216244_3
25/ET/SEMICC/2018-19/S
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
365 days
Kadukutty Panchayath in Thrissur District
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,940
Yes
online
₹50,000
Yes
3 Jun 2020
29 Aug 2018
25 Sept 2018
29 Aug 2018
17 Sept 2018
10 Sept 2018
29 Aug 2018 - 10 Sept 2018
Amount
CIVIL WORKS- Appx.A Construction of Pump house 2.8.1 : Earth work excavation in all kinds of soil, by mechanical means (Hydraulic excavator) / manual means, for column footings and motor foundation (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, getting out the excavated soil, back filling wherever necessary and disposal of surplus excavated soil with all leads and lifts, etc. complete as per the directions of the departmental officers at site.
2.6.1 : Earth work excavation in all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) for foundation of protection wall and cistern, including back filling wherever necessary and disposal of excess excavated earth with all leads and lifts, disposed earth to be levelled and neatly dressed , etc. complete as per the directions of the departmental officers at site.
4.1.8 : Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering for foundation of pillars, cistern, etc. complete as per the directions of the departmental officers at site.
5.1.2 : Providing and laying in position 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size ) for all works upto plinth level, excluding the cost of centering, shuttering, and reinforcement - for pillars, plinth beam, etc. complete as per the directions of the departmental officers at site.
5.2.2 : Reinforced cement concrete work using 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for all works upto floor five level, excluding cost of centering, shuttering, and reinforcement - for pillars, walls, cistern, etc. complete as per the directions of the departmental officers at site.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for foundation of columns, protection wall , etc. complete as per the directions of the departmental officers at site.
5.9.2 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for walls, cistern, intermediate belt of protection wall, etc. complete as per the directions of the departmental officers at site.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for landing, floor slab, roof slab, etc. complete as per the directions of the departmental officers at site.
5.9.5 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for lintels, floor beams, plinth beams, etc. complete as per the directions of the departmental officers at site.
5.9.6 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for columns, etc. complete as per the directions of the departmental officers at site.
5.9.7 : Centering and shuttering including strutting, etc. and removal of form work after completion of work for waist slab, steps, etc. complete as per the directions of the departmental officers at site.
5.22.6 : Steel reinforcement using Thermo - mechanically treated bars of grade Fe 500 D or more for R.C.C works including straightening, cutting, bending, placing in position and binding all , etc. complete as per the directions of the departmental officers at site.
5.3 : Reinforced cement concrete works with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size) for works upto floor five level, excluding the cost of centering, shuttering and reinforcement - for lintels, floor beams, floor slabs, steps, waist slab, landing, etc. complete as per the directions of the departmental officers at site.
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure upto floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand), for walls and parapet of pump house, etc. complete as per the directions of the departmental officers at site.
50.9.1.1 : Providing wood work in frames of windows, wrought, framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood, etc. complete as per the directions of the departmental officers at site.
50.9.5.1 : Providing and fixing Anjili wood/ jack wood 35 mm thick glazed shutters for windows, using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished, of required size with necessary screws, etc. complete as per the directions of the departmental officers at site.
50.9.15.5 : Providing and fixing iron hooks and eyes 100 mm, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
50.13.1 : Providing 9 mm thick cement plastering of mix : 1:3 (1 cement : 3 fine sand ),for beams, floor slabs, steps, landing, waist slab, walls, cistern, columns including cost of all materials and labour charges , etc. complete as per the directions of the departmental officers at site.
10.6.3 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation , including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover, etc. complete as per the directions of the departmental officers at site.
10.7 : Providing and fixing ball bearing for rolling shutters, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
13.1.1 : Providing 12 mm thick cement plaster of mix:1:4 ( 1 cement : 4 fine sand) for pump house walls, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
13.7.1 : Providing 12 mm thick cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) for roof top, including cost of all materials and labour charges , etc. complete as per the directions of the departmental officers at site.
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate), 40 mm thick with 20 mm nominal size stone aggregate, finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps , etc. complete as per the directions of the departmental officers at site.
9.48.2 : Providing and fixing M.S. Grills of required pattern fixed with rawl plugs and screws in frames of windows with M.S. flats, square or round bars, including priming coat with approved steel primer , etc. complete as per the directions of the departmental officers at site.
13.41.1 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on plastered areas ( Two or more coats) over and including priming coat with water thinnable cement primer, etc. complete as per the directions of the departmental officers at site.
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer for hand rails , etc. complete as per the directions of the departmental officers at site.
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable materials within 50 metres lead, etc. complete as per the directions of the departmental officers at site.
15.7.4 : Demolishing brick work in cement mortar manually / by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead , etc. complete as per the directions of the departmental officers at site.
15.9.2 : Demolishing stone rubble masonry in cement mortar manually / by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead , etc. complete as per the directions of the departmental officers at site.
15.12.1 : Dismantling doors and windows (steel or wood ) shutters of area 3 sq. metres and below including chowkhats, architrave and holdfasts, stacking within 50 metres lead, etc. complete as per the directions of the departmental officers at site.
15.44.2 : Dismantling suction and delivery G.I. pipes ( external work) above 40 mm nominal bore, including excavation and refilling trenches after taking out the pipes, manually / by mechanical means, stacking of pipes within 50 metres lead , etc. complete as per the directions of the departmental officers at site.
od2481/2016_2017/IA : Manufacturing, supplying and fitting 350 mm diameter M S flange having shell thickness 10 mm depth 75 mm with suitable bolt holes, fixing the flange in position with required welding around the flange pipe joint grinding for smoothing the welded portion including painting with red oxide primer, etc. complete as per the directions of the departmental officers at site.
od2482/2016_2017/IA : Manufacturing, supplying and fitting 350 mm diameter M S pipe of various length with shell thickness 6 mm including painting with 2 coats of red oxide primer, laying the same to line and level , etc. complete as per the directions of the departmental officers at site.
60.7.1 : Dry rubble masonry without concrete levelling course with good quality blasted rubble, for foundation and superstructure of protection wall, packing below column foundation, including packing to compactness to lines and levels, cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
4.1.5 : Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centering and shuttering - for top belt over protection wall, etc. complete as per the directions of the departmental officers at site.
5.1.3 : Providing and laying in position reinforced cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , excluding the cost of centering, shuttering and reinforcement - for intermediate belt of protection wall, cistern slab, etc. complete as per the directions of the departmental officers at site.
13.48.2 : Painting wood work with Deluxe Multi Surface Paint of required shade for windows, with two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer of approved brand and manufacture applied @ 0.75 ltr/10 sqm, etc. complete as per the directions of the departmental officers at site.
13.48.3 : Painting Steel work with Deluxe Multi Surface Paint to give an even shade for rolling shutters, with two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer of approved brand and manufacture applied @ 0.80 ltr/10 sqm , etc. complete as per the directions of the departmental officers at site.
60.7.8 : Dry rubble masonry without concrete levelling course using departmental rubble for protection work , including packing to compactness to lines and levels and labour charges , etc. complete as per the directions of the departmental officers at site.
4.1.3 : Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), excluding the cost of centering and shuttering - for motor foundation, pipe support, etc. complete as per the directions of the departmental officers at site.
od2483/2016_2017/IA : Supplying ISMB 250 for handling of Motor and pump, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
Appx. B Construction of Toilet 2.8.1 : Earth work excavation in all kinds of soil, by mechanical means (Hydraulic excavator) / manual means, for toilet foundation (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, getting out the excavated soil, back filling wherever necessary and disposal of surplus excavated soil with all leads and lifts, etc. complete as per the directions of the departmental officers at site.
60.7.1 : Dry rubble masonry without concrete levelling course with good quality blasted rubble, for foundation of toilet, including packing to compactness to lines and levels, cost and conveyance of all materials and labour charges , etc. complete as per the directions of the departmental officers at site.
7.1.1 : Random rubble masonry in cement mortar 1:6 (1 cement : 6 coarse sand) with hard stone for basement , including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size), etc. complete as per the directions of the departmental officers at site.
5.3 : Reinforced cement concrete works with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size) for works upto floor five level, excluding the cost of centering, shuttering and reinforcement - for toilet roof, etc. complete as per the directions of the departmental officers at site.
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for toilet walls with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand), etc. complete as per the directions of the departmental officers at site.
50.13.1 : Providing 9 mm thick cement plastering of mix : 1:3 (1 cement : 3 fine sand ), for toilet ceiling, including all cost of materials and labour charges, etc. complete as per the directions of the departmental officers at site.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form work for roof slab, etc. complete as per the directions of the departmental officers at site.
13.7.1 : Providing 12 mm thick cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) including all cost of materials and labour charges, for roof top , etc. complete as per the directions of the departmental officers at site.
5.22.6 : Steel reinforcement using Thermo - mechanically treated bars of grade Fe 500 D or more for toilet roof slab including straightening, cutting, bending, placing in position and binding all , etc. complete as per the directions of the departmental officers at site.
50.9.1.1 : Providing wood work in frames of doors, wrought, framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood, etc. complete as per the directions of the departmental officers at site.
50.9.4.1 : Providing and fixing paneling or paneling and glazing in panelled or panelled and glazed shutters of 25 mm to 40 mm thick using good quality Anjili / Jack wood, for doors, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) , etc. complete as per the directions of the departmental officers at site.
13.1.1 : Providing 12 mm thick cement plaster of mix:1:4 ( 1 cement : 4 fine sand) for toilet walls, including cost of all materials and labour charges , etc. complete as per the directions of the departmental officers at site.
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate), 40 mm thick with 20 mm nominal size stone aggregate, finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps , etc. complete as per the directions of the departmental officers at site.
17.13.1 : Providing and fixing white Vitreous China Long pattern water closet squatting pan ( Indian type) of size 580 mm, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
17.17.2 : Providing and fixing a pair of white Vitreous China foot rests 250x125x25 mm of standard pattern for squatting pan water closet, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
13.41.1 : Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on plastered areas ( Two or more coats) over and including priming coat with water thinnable cement primer, etc. complete as per the directions of the departmental officers at site.
50.18.9.20.7 : Providing and fixing 63 mm diameter vent cowl including jointing with PVC solvent cement , including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
od2800/2016_2017/IA : Supplying and fitting Ferro cement septic tank and sock pit, including cost and conveyance of all materials and labour charges for erection, etc. complete as per the directions of the departmental officers at site.
od2801/2016_2017/IA : Supplying and fitting 63 mm diameter PVC pipe 4 kgf/cm2 , including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
od2802/2016_2017/IA : Supplying and fitting 110 mm diameter PVC pipe 4 kgf/cm2, for connecting septic tank,closet,soak pit, including cost and conveyance of all materials and labour charges, etc. complete as per the directions of the departmental officers at site.
ELECTRICAL WORKS - Part I Dismantling Dismantling 30 HP motor pump set, lifting to the floor level, leading to the nearest road side, loading to the vehicle, conveyance and unloading at the section store and storing as per directions.
Dismantling 50 HP motor pump set, lifting to the floor level, leading to the nearest road side, loading to the vehicle, conveyance and unloading at the section store and storing as per directions.
Dismantling 3/5 hp motor pump(1 No.old one) set lifting to the floor level, leading to the nearest road side, loading to the vehicle, conveyance and unloading at the section store and storing as per directions.
Dismantling Panel board, meter board, Starters, Isolators, PVC conduits, Wiring etc. without damages and leading the whole to the nearest road side and loading to the vehicle, conveyance to the section store, unloading and storing as per directions.
Leading 50 HP Old motor to the nearest road side, loading to the vehicle, conveyance and unloading at the section store and storing as per directions.
Dismantling and lifting 50 HP old pump to the floor level, leading to the nearest road side, loading to the vehicle, conveyance and unloading at the section store and storing as per directions.
Part 2- Electrification Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with No.14 SWG copper earth , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular typeROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. a)Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting made from 0.5mmCRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. a) 16wLED light fittings
Supply, conveyance, installation, testing and commissioning of 20 W, 105 lumen/W IP66 LED Street light fittings withn all accessories Strada plus Osram or Equivalent make on existing GI Pipe and giving Connection
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings). a)25 mm dia with HG company fabricated clamps
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder without shade and giving connection etc as required
Supply and fixing shades of the following types of shades on existing batten / pendent/bracket fittings as required a)200 mm plastic shade
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
Supply and providing the following types and power rated lamps in the existing fittings as required a) Normal size 5/7 W LED bulb
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. a)1200 mm sweep - 5 star rated
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. a) 20 mm dia light gauge
b) 40 mm dia light gauge (MR)
c)50 mm dia light gauge (MR)
d)63 mm dia light gauge (MR)
Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. a) 20 mm dia
b) 40mm dia (MR)
c) 50 mm dia (MR)
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. a) 2.50 sq mm 2 run
2.50 sq mm 3 run
16.00 sq mm 3 run
25 sq mm 3 run (MR)
25 sq mm 6 run (MR)
35 sq. mm. 1 run (MR)
35 sq mm 3 run (MR)
35 sq mm 6 run (MR)
70 sq. mm. 3 run (MR)
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. a) 2.5 sq mm
b) 16 sq mm
c) 25 sq mm
d) 35 sq mm
e) 70 sq mm
Supply and clamping the following sizes of PVC pipe on wall with all required accessories including cutting and making good the walls, colour washing etc. as required as protective covering to cables. a) 75 mm dia PVC pipe (8 Kgf / cm2)
Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron/ flat cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gear, fixed to wall using suitable size anchor bolts or grouted to wall, making good the damages, colour washing etc as required.
Fabrication, supply, conveyance and fixing cable entry/ wire way box made out 1.60 mm CRCA sheet of suitable size to match the switch gear and enabling the cables to be connected without strain, powder coated after subjecting to 7 tank process & with drilled holes and mounting to the switch gear etc as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required a) 300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. a) 2 x 25 x 3 mm GI strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. a) 25 x 3 mm GI strip
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. a) 2.65 mm copper conductor (12 SWG)
b)3.15 mm copper conductor (10 SWG)
c) 4.75 mm copper conductor (6 SWG)
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). a) 4.75 mm copper conductor (6 SWG)
Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for horizontal run). a) 25 x 3 mm GI strip
b) 25 x 3 mm copper strip tinned at the points of contacts
Supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required. a) 2.65 mm (12 SWG)
b) 3.15 mm (10 SWG)
c) 4.75 mm (6 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required a) 25 x 3mm brass bolt & nut
b) 25 x 6 mm brass bolt & nut
Supplying , threading , laying and jointing of the following sizes of 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. a)15 mm dia
Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for horizontal run). a) 25 x 3 mm copper strip tinned at the points of contacts
Supply and fixing 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor suitable for direct connection to motors. .a) 1 KVAr
b) 8 KVAr
c)12.5 KVAr
Supply & renewal of switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the following ratings: a) 63A
Supply & renewal of 20 A fuse holder for BS type blade fuses.
Supply & renewal of 2 A-16A clip-on offset tag fuse link of size f1
Supply & renewal of 25 A, 2 pole, 30 mA RCCB
Aluminium anodised Danger Notice Board of size 100 x 75 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
Fabrication, supply & installation of dust and vermin proof, wall mounting, syntex make thermoplastic meter box of size 1040x730x290 mm GSMB- 10069 suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.(MR)
Supply and fixing the following accessories in the existing meter board and giving connections etc. a)250 A, 415 V, DIN type fuse base.
b) 250 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
c) 200,250,315A, DIN type fuse link of size 2
Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.
Supplying and installation of supports, anchor bolts etc made out of suitable size single section MS angle, flats etc as required including painting with 2 coats of synthetic enamel paint
Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
Supply of rubber hand gloves (MR)
Supply and providing vacuum line connection with necessary hose collars, nipples, reducers and hose clips pvc ball valves etc to suit the size of vacuum pump & giving vacuum connection.
Supply and providing 25 mm green flexible hose and giving connection etc.
Supply and clamping the following sizes of "B" class GI pipe on wall with all required accessories & clamps etc., including cutting and making good the walls, painting the exposed portions etc., as protective covering to earth leads / cables .a) 32 mm dia
Erection, testing and commissioning of starter of 30/50 hp motor
Erection, testing and commissioning of starter of 5 hp motor
Refitting charge of panel board on existing angle iron frame to wall / floor. Including giving necessary connections as required.
Refitting charge of isolator 32/100 A on existing angle iron frame to wall / floor. Including giving necessary connections as required.
Refitting charge of single phase DB with isolator ELCB MCB etc..on existing wall / floor, including giving necessary connections as required.
Re-fitting of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. directly on wall/ ceiling using 2 nos. C/U shaped brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
Re-fitting of cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 11 w CFLamps including connection etc as required.
Re-fitting of angle/straight batten holder with shade including connection etc as required
Re-clamping the following PVC pipe using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. a) 20 mm
Drawing PVC insulated stranded single core copper conductor cables of following sizes in existing pipe and giving connection as required. .a) 2.5 Sqmm
b) 25/35/75 Sqmm
Drawing the existing bare earthing conductors of following sizes along with wiring/ cables and giving connection as required. .a) 3.15 mm copper conductor (10 SWG)
b) 4.75 mm copper conductor (6 SWG)
Part 3- Returning & Errection Returning the dismantled 30 HP motor pump set from section store, loading to the vehicle, conveyance and unloading at the nearest road side and leading to the pump house.
Returning the dismantled 50 HP motor pump set from section store, loading to the vehicle, conveyance and unloading at the nearest road side and leading to the pump house.
Returning the dismantled 3 HP motor pump set from section store, loading to the vehicle, conveyance and unloading at the nearest road side and leading to the pump house.
Returning the dismantled Panel board, meter board, Starters, Isolators, PVC conduites, Wiring, frame work etc. from section store, loading to the vehicle,conveyance and unloading at the nearest road side and leading to the pump house.
Erection, alignment, testing and commissioning of 30 HP motor pump set on the existing foundation
Erection, alignment, testing and commissioning of 50 HP motor pump set on the existing foundation
Erection, alignment, testing and commissioning of 3/5 HP motor pump set on the existing foundtion
Earth work excavation in ordinary soil and depositing with a lead up to 50 m and lift up to 1.50 m including neat banking
Cement concrete 1:3:6 using 20mm (nominal size) broken stone for reinforced concrete work.
Brick work in cement mortar 1:6 with country burnt bricks 19cm x 9cm x 9cm for foundation and basement.
Plastering with cement mortar 1:4, 12mm thick one coat.
Supply of foundation bolt suitable for 30/50 HP motor pump set
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_305955.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .