Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.5 LAccepted-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹68.5 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | - | Rejected-Technical L4 |
| 3 | Rejected-Technical H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | - | - | Rejected-Technical L2 |
| 4 | Rejected-Technical 31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | RS COOLING APPLIANCES L2 | Eastern Commerce L4 | STANDARD ELECTRONICS L3 | R.P.ELECTRONICS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge.. | 84 | No | 52,000 ₹43.7 L | 54,100 ₹45.4 L | 51,000 ₹42.8 L | 51,000 ₹42.8 L |
| 2.00 | Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge.. | 42 | No | 44,000 ₹18.5 L | 39,400 ₹16.5 L | 40,700 ₹17.1 L | 35,000 ₹14.7 L |
| 3.00 | Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge | 126 | No | 1,500 ₹1.9 L | 1,700 ₹2.1 L | 3,250 ₹4.1 L | 4,000 ₹5.0 L |
| 4.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge | 126 | NO | 690 ₹86,940 | 730 ₹91,980 | 1,000 ₹1.3 L | 2,000 ₹2.5 L |
| 5.00 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. | 504 | Mtr. | 500 ₹2.5 L | 700 ₹3.5 L | 650 ₹3.3 L | 400 ₹2.0 L |
| 6.00 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 378 | Mtr. | 115 ₹43,470 | 105 ₹39,690 | 120 ₹45,360 | 40 ₹15,120 |
| 7.00 | Providing & Fitting fixing of 1" UPVC drain pipe as per direction of the Engineer-in-Charge. | 504 | Mtr. | 135 ₹68,040 | 210 ₹1.1 L | 120 ₹60,480 | 250 ₹1.3 L |
Tender Value
₹87.0 L
EMD Value
₹1.7 L
Closing Date
28 Apr 2025, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing fitting fixing of Air Conditioning machines of 14 Fourteen nos Type VI quarter at Secretariat quarter complex Vallukiya tilla Agartala Tripura W
2025_CEPWD_60280_1
01 _B_DNIeT_SEIV_PWDRB_2526
Open Tender
Electrical Works
180 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹4,000
₹1.7 L
19 Mar 2026
10 Apr 2025
28 Apr 2025
10 Apr 2025
28 Apr 2025
10 Apr 2025
Amount
Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge..
Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge..
Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable.
Providing & Fitting fixing of 1" UPVC drain pipe as per direction of the Engineer-in-Charge.
RS COOLING APPLIANCES (BID ID -173810)
STANDARD ELECTRONICS (BID ID -173918)
Eastern Commerce (BID ID -173917)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_61303.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid